LEM HY12-P

Current Transducers HY 5..25-P
IPN
=
5 .. 25 A
For the electronic measurement of currents : DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal
current rms
IPN (A)
Primary current,
measuring range
IPM (A)
5
10
12.5
15
20
25
±
±
±
±
±
±
15
30
37.5
45
60
75
Primary
conductor
(mm)
∅ 0.7
∅ 1.1
∅ 1.4
∅ 1.4
2 x ∅ 1.2
2 x ∅ 1.4
1)
1)
Type
RoHS since
date code
HY 5-P
HY 10-P
HY 12-P
HY 15-P
HY 20-P
HY 25-P
45260
45286
45264
45276
46097
45269
Features
Supply voltage (± 5 %) 6)
Current consumption
Overload capability (1 ms)
Rms voltage for AC isolation test, 50 Hz, 1 min
Rated isolation voltage rms
Isolation resistance @ 500 VDC
Output voltage (Analog) @ + IPN, RL = 10 kΩ, TA = 25°C
Output internal resistance
Load resistance
VC
IC
ÎP
Vd
Vb
R IS
VOUT
ROUT
RL
± 12 .. 15
± 10
50 x IPN
2.5
500 2)
> 1000
±4
100
>1
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
V
mA
kV
V
MΩ
V
Ω
kΩ
Accuracy - Dynamic performance data
X
ε
Accuracy @ IPN, TA = 25°C (excluding offset)
Linearity error 3) (0 .. ± IPN)
Electrical offset voltage@ TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x IPN
Temperature coefficient of VOE
L
VOE
VOH
TCVOUT
tr
di/dt
BW
<±1
<±1
< ± 40
%
% of IPN
mV
Notes :
Ambient operating temperature
Ambient storage temperature
Mass
Standards 5)
1)
2)
3)
4)
5)
6)
Advantages
• Easy mounting
• Small size and space saving
• Only one design for wide current
• High immunity to external
interference.
Applications
mV
mV/K
mV/K
%/K
µs
A/µs
kHz
General data
TA
TS
m
according to UL 94-V0.
ratings range
< ± 15
typ. ± 1.5
max. ± 3
Temperature coefficient of VOUT (% of reading)
< ± 0.1
Response time to 90% of IPN step
<3
di/dt accurately followed
> 50
Frequency bandwidth 4) (- 3 dB)
DC .. 50
TCVOE
• Isolation voltage 2500 V~
• Compact design for PCB mounting
• Low power consumption
• Extended measuring range (3 x IPN)
• Insulated plastic case recognized
- 10 .. + 80 °C
- 25 .. + 85 °C
< 14
g
EN 50178: 1997
• Static converters for DC motor drives
• Switched Mode Power Supplies
(SMPS).
• AC variable speed drives
• Uninterruptible Power Supplies
(UPS)
• Battery supplied applications
• General purpose inverters
Application domain
• Industrial
Conductor terminals are soldered together.
Pollution class 2, overvoltage category III.
Linearity data exclude the electrical offset.
Please refer to derating curves in the technical file to avoid excessive
core heating at high frequency.
Please consult characterisation report for more technical details and
application advice.
Operating at ±12V ≤ Vc < ±15V will reduce measuring range.
061027/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/2
www.lem.com
Dimensions HY 5..25-P (in mm. 1 mm = 0.0394 inch)
36.0 Max.
HY 5 to 15-P
32.0 Max.
JA PAN
12 Max.
18.0
12.0
HY 5-P
45059
HY 10 - P
JP2
9639
( d)
(0.5)
3 x 2.54
10±0.3
1 2 3 4
5
HY 20 to 25-P
3.9±0.3
6
HY 20 - P
9639
3±0.5
(
PIN ARRANGEMENT
1
2
3
4
dx2)
+15V
--15V
OUTPUT
0V
5 PRIMARY IN
6 PRIMARY OUT
8.5±0.3
10±0.3
3 x 2.54
(0.3)
(a)±0.3
8.5±0.3
PCB MOUNTING DIMENSIONS (in mm ±0.1, hole -0, +0.2)
2 holes dia. (e)
HY 5 to15-P
3 x 2.54
10
8.5
HY 20 to 25-P
Type
holes dia (e)
4 holes dia 1
(g)
3 x 2.54
10
(g)
8.5
HY
HY
HY
HY
HY
HY
05-P
10-P
12-P
15-P
20-P
25-P
a
mm
1.1
1.4
1.5
1.5
1.4
1.5
d
mm
0.7
1.1
1.4
1.4
1.2
1.4
e
mm
1.2
1.6
2.0
2.0
1.8
2.0
g
mm
----1.4
1.6
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements
in accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/2
061027/8
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com