Current Transducer LA 100-S/SP1 IPN = 100 A For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). 0629 Electrical data I PN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance with ± 15 V ISN KN VC IC Vd @ ± 100 A max @ ± 200 A max Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 min 100 0 .. ± 200 RM min RM max 0 0 180 50 50 1 : 2000 ± 15 22 + IS 3 A A Ω Ω ε Overall accuracy @ IPN, T A = 25°C Linearity error L transducer using the Hall effect • Insulated plastic case recognized according to UL 94-V0. V mA kV Special features • I P = 0 .. ± 200 A • K N = 1 : 2000 Advantages ± 0.5 < 0.1 Typ % % Max ± 0.1 ± 0.4 IO IOT Offset current @ IP = 0, T A = 25°C Thermal drift of IO - 10 °C .. + 70°C ± 0.2 tr di/dt f Response time 1) @ 90 % of IPN di/dt accurately followed Frequency bandwidth (- 1 dB) <1 > 50 DC .. 150 mA mA µs A/µs kHz • • • • • • • Excellent accuracy Very good linearity Low temperature drift Optimized response time Wide frequency bandwidth No insertion losses High immunity to external interference • Current overload capability. Applications General data TA TS RS m • Closed loop (compensated) current mA Accuracy - Dynamic performance data XG Features Ambient operating temperature Ambient storage temperature Secondary coil resistance @ T A = 70°C Mass Standards 2) - 10 .. + 70 - 25 .. + 85 85 65 EN 50178 °C °C Ω g • AC variable speed drives and servo motor drives • Static converters for DC motor drives • Battery supplied applications • Uninterruptible Power Supplies (UPS) • Switched Mode Power Supplies (SMPS) • Power supplies for welding applications. Notes : 1) 2) With a di/dt of 50 A/µs A list of corresponding tests is available. 060901/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM page 1/2 www.lem.com Dimensions LA 100-S/SP1 (in mm. 1 mm = 0.0394 inch) Front view Left view Secondary terminals Terminal Terminal Terminal Terminal + M 0 : : : : supply voltage + 15 V supply voltage - 15 V measure NC Connection Top view Mechanical characteristics • • • • General tolerance Fastening Primary through-hole Connection of secondary Remarks ± 0.3 mm 2 holes ∅ 3.2 mm 16 x 10 mm Molex 5045-04/AG • IS is positive when IP flows in the direction of the arrow. • Temperature of the primary conductor should not exceed 100°C. • Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. • In order to achieve the best magnetic coupling, the primary windings have to be wound over the top edge of the device. • To measure nominal currents of less than 100 A, the optimum accuracy is obtained by having several primary turns (nominal current x number of turns < 100 At). 060901/6 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM Page 2/2 www.lem.com