LEM LB1000-SP2

Current Transducer LB 1000-SI/SP2
IPN
=
1000 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
IPN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance
with ± 15 V
ISN
KN
VC
IC
@ ± 1000 A max
@ ± 1500 A max
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
1000
0 .. ± 1500
RM min RM max
0
0
25
5
200
1 : 5000
± 15
21 + IS
A
A
Features
Ω
Ω
• Insulated plastic case recognized
• Closed loop (compensated) current
transducer using the Hall effect
mA
VDC
mA
according to UL 94-V0.
Special features
• TA = + 10°C .. + 50°C
• Shield between primary and
secondary.
Accuracy - Dynamic performance data
XG
ε
Overall accuracy @ IPN , TA = 25°C
Linearity error
L
Advantages
± 0.3
< 0.1
Typ
%
%
Max
± 0.4
± 0.2
IO
IOT
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
+ 10°C .. + 50°C
± 0.1
tr
di/dt
f
Response time 1) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
<1
> 50
DC .. 100
mA
mA
µs
A/µs
kHz
General data
TA
TS
RS
m
•
•
•
•
•
•
•
•
Better zero crossing performance
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
• Current overload capability.
Applications
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ TA = 70°C
Mass
Standards
+ 10 .. + 50
°C
- 25 .. + 85
°C
40
Ω
700
g
EN 50178 : 1997
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Application domain
Note : 1) With a di/dt of 100 A/µs
• Industrial.
050816/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
Page 1/3
w w w.lem.com
Current Transducer LB 1000-SI/SP2
Isolation characteristics
Vd
Vw
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
Impulse withstand voltage 1.2/50 µs
6
17
dCp
dCl
CTI
Creepage distance
Clearance distance
Comparative Tracking Index (Group IIIa)
Min
54.5
44.4
225
kV
kV
mm
mm
Application examples
According to EN 50178 and CEI 61010-1 standards and following conditions :
• Over voltage category OV 3
• Pollution degree PD2
• Non-uniform field
EN 50178
CEI 61010-1
Rated isolation voltage
Nominal voltage
Single isolation
5000 V
Cat IIIa 5000 V rms
Reinforced isolation
2500 V
Cat IIIa 2500 V rms
dCp, dCI, Vw
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the following
manufacturer's operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
050816/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
Page 2/3
w w w.lem.com
Dimensions LB 1000-SI/SP2 (in mm. 1 mm = 0.0394 inch)
Front view
Left view
Secondary terminals
Terminal + : supply voltage + 15 V
Terminal M : measure
Terminal - : supply voltage - 15 V
Connection
Top view
Mechanical characteristics
• General tolerance
• Fastening
Recommended fastening torque
• Primary through-hole
• Connection of secondary
Remarks
± 0.5 mm
4 slots ∅ 7 mm
4 M5 steel screws
4 Nm or 2.95 Lb. - Ft.
∅ 40 mm
Faston 6.3 x 0.8 mm.
• IS is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
050816/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
Page 3/3