LX1972A ® TM Ambient Light Detector P RODUCTION D ATA S HEET KEY FEATURES DESCRIPTION by placing it in series with a single resistor at either of its two pins. Dynamic range is determined by the resistors (typically in the range of 5K to 100K) and the power supply values. Typically the LX1972A needs only 2.7V of headroom to operate at 1000 Lux illumination. Internal temperature compensation allows dark current to be kept below 200nA over the full specification temperature range (-40°C to +85°C), providing high accuracy at low light levels. Usable ambient light conditions range is from 1 to more than 5000 Lux. The LX1972A is optimized for controlling back lighting systems in low cost consumer products such as LCD TV, portable computers, and digital cameras. Near Human Eye Spectral Response Very Low IR Sensitivity Highly Accurate & Repeatable Output Current vs. Light Scalable Output Voltage Temperature Stable Integrated High Gain Photo Current Amplifiers No Optical Filters Needed WWW . Microsemi .C OM The LX1972A is a low cost silicon light sensor with a spectral response that closely emulates the human eye. Patented circuitry produces peak spectral response at 580nm, with an IR response less than ±5% of the peak response, above 900nm. The photo sensor is a PIN diode array with Microsemi’s Best Eye™ processing that provides a nearly perfect photopic light wavelength response curve. LX1972A provides a linear, accurate, and very repeatable current transfer function. High gain current mirrors on the chip multiply the PIN diode photo-current to a sensitivity level that can be voltage scaled with a standard value external resistor. Output current from this simple to use two-pin device can be used directly or converted to a voltage APPLICATIONS Portable Electronic Displays LCD TV Backlight Systems Digital Still Cameras (DSC) Desk Top Monitors Notebook Computers IMPORTANT: For the most current data, consult MICROSEMI’s website: http://www.microsemi.com Protected By U.S. Patents: 6,787,757; Patents Pending PRODUCT HIGHLIGHT VDD VDD 1.7V Typical @ 100 Lux LX1972A VSS VSS Ambient Light LX1972A LX1972A PACKAGE ORDER INFO TA (°C) BC Plastic 1206 2-Pin RoHS Compliant / Pb-free -40 to 85 LX1972AIBC Note: Available in Tape & Reel. Append the letters “TR” to the part number. (i.e. LX1972AIBC-TR) Copyright © 2005 Rev. 1.0, 2006-09-18 Microsemi Integrated Products Group 11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 Page 1 LX1972A ® TM Ambient Light Detector P RODUCTION D ATA S HEET ABSOLUTE MAXIMUM RATINGS PACKAGE PIN OUT VDD VSS 1 2 BC PACKAGE (Top View) RoHS / Pb-free Gold Lead Finish Note: Exceeding these ratings could cause damage to the device. All voltages are with respect to Ground. Currents are positive into, negative out of specified terminal. WWW . Microsemi .C OM Supply Input Voltage ...........................................................................-0.3V to 6V Ground Current ..........................................................................Internally Limited Operating Temperature Range .........................................................-40°C to 85°C Maximum Operating Junction Temperature ................................................ 150°C Storage Temperature Range.........................................................-40°C to +100°C Peak Package Solder Reflow Temp. (40 second max. exposure) ... 260°C (+0, -5) THERMAL DATA BC Plastic 1206 2-Pin THERMAL RESISTANCE-JUNCTION TO AMBIENT, θJA 850°C/W Junction Temperature Calculation: TJ = TA + (PD × θJA). The θJA numbers are guidelines for the thermal performance of the device/pc-board system. All of the above assume no ambient airflow. FUNCTIONAL PIN DESCRIPTION Name VDD VSS Description Positive Terminal Negative Terminal PACKAGE DATA Copyright © 2005 Rev. 1.0, 2006-09-18 Microsemi Integrated Products Group 11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 Page 2 LX1972A ® TM Ambient Light Detector P RODUCTION D ATA S HEET CHARACTERISTIC CURVES Human Eye 3.50 0.8 Minimum VDD Voltage Normalized Diode Response 4.00 LX1972A 1.0 WWW . Microsemi .C OM 1.2 0.6 0.4 0.2 0.0 3.00 2.50 2.00 1.50 1.00 @ 1000 Lux & 5k Load Resistor 0.50 -0.2 @ 100 Lux & 5k Load Resistor 400 600 800 Wavelength (nm) 0.00 -40 1000 -20 0 20 40 Temperature (ºC) 60 80 Chart 2 –Minimum VDD Voltage vs. Temperature Chart 1 – Response vs. Wavelength IOUT vs Temperature @ 10, 100 Lux 25.00 400 350 15.00 IOUT @ 100 Lux 300 IOUT @ 10 Lux 250 ID (nA) IOUT (µA) 20.00 10.00 200 150 100 5.00 0.00 -40 50 -20 0 20 40 60 80 0 -40 -20 0 20 40 60 80 100 Temperature (°C) Temperature (ºC) Chart 4 – Dark Current vs. Temperature Chart 3 – IOUT vs. Temperature CHARTS Copyright © 2005 Rev. 1.0, 2006-09-18 Microsemi Integrated Products Group 11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 Page 3 LX1972A ® TM Ambient Light Detector P RODUCTION D ATA S HEET ELECTRICAL CHARACTERISTICS Parameter ` Symbol ≤ 85°C except where otherwise noted and with Test Conditions Min LX1972A Typ Max Units RESPONSE λPR Peak Spectral Response Infrared Response IDD (λ ) IDD (λ PR ) Minimum Operational Voltage VDD-VSS Light Current ISS Gain Linearity Dark Current IDD(DARK) Power Supply Rejection Ratio Radiant Sensitive Area PSRR 580 EV(white) = 1000 Lux, EV(810nm) = 146µW/cm², Note 3 EV = 100 Lux EV = 1000 Lux EV = 2000 Lux EV = 10 Lux, Note 2 EV = 100 Lux, Note 2 EV = 1000 Lux, Note 2 EV = 2000 Lux, Note 2; 10 Lux ≤ EV ≤ 1000 Lux EV = 0 Lux, TA = 25°C EV = 0 Lux VRIPPLE = 10mVP-P, f = 10kHz -5 1.8 18 176 353 -15 nm 1 5 1.4 2.2 2.8 2.4 24 235 470 2 2.7 3 3 30 294 587 15 50 200 2 -25 0.04 % V WWW . Microsemi .C OM The following specifications apply over the operating ambient temperature -40°C ≤ TA the following test conditions: See Note 1, VDD =5V, Rload = 5K μA % nA dB mm2 Notes: 1. The input irradiance (EV) is supplied from a white light-emitting diode (LED) optical source. 2. See Figure 1. 3. See Figure 2. TEST CIRCUITS VDD VDD LX1972A Part LX1972A Part White LED White LED 810nm VSS 5K Copyright © 2005 Rev. 1.0, 2006-09-18 5K Figure 2 – IR Sensitivity Measurement Circuit Microsemi Integrated Products Group 11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 ELECTRICALS Figure 1 – Operational Voltage Measurement Circuit VSS Page 4 LX1972A ® TM Ambient Light Detector P RODUCTION D ATA S HEET SIMPLIFIED BLOCK DIAGRAM WWW . Microsemi .C OM LX1972A VDD Current Amp VSS Figure 3 – Simplified Block Diagram APPLICATION NOTE LIGHT UNITS 2 Copyright © 2005 Rev. 1.0, 2006-09-18 Microsemi Integrated Products Group 11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 Page 5 APPLICATIONS In converting from µW/cm to lux it is necessary to define the light source. Lux is a unit for the measurement of illuminance, which is the photometric flux density or visible light flux density. Whereas µW/cm2 is a measurement of irradiance or the measurement of electromagnetic radiation, flux both visible and invisible. The first step in the conversion process is to convert irradiance to illuminance, which essentially involves running the irradiant flux through a photopic filter. In normal ambient, a photopic curve is used and in dark ambient, a scotopic curve (dark adapted eye) is used. If the light is composed of only one wavelength, a conversion chart will tell the conversion factor to convert µW/m2 to lux (lumens/m2). If more than one wavelength is used, the light spectrum of the irradiance must be applied to the photopic filter to determine the resultant illuminance. The most sensitive wavelength for the normal light adapted human eye is 555nm, which corresponds to yellowish-green light. At 555nm, the conversion factor is 683 Lux = 1W/m2 = 100µW/cm2. Therefore 14.6µW/cm2 = 100 lux at 555nm. If the photo sensor had a truly photopic response, it would produce the same output current for the same number of lux, regardless of the color of the light. However, because the match is not perfect, there is still wavelength dependency particularly at the ends of the visible spectrum. In the case of the LX1972A the peak photo response is at 580nm, however depending on the light source, what the human eye perceives as ‘white’ light may actually be composed of peak wavelengths of light other than 520nm. For instance, a typical fluorescent lamp includes dominant light not only near 550nm but also at 404 and 435nm. Incandescent light sources such as standard tungsten lights generate substantial IR radiation out beyond 2000nm. For ease of automatic testing of the LX1972A the ATE (Automatic Test Equipment) light source is configured with white LEDs whose current is adjusted to output a calibrated flux density. This allows consistent and repeatable testing of the sensor but corresponds to a light source unlike that typically found in an office, home or sunlit environment. In practice, the user needs to place the sensor in the target environment and calibrate the sensors output current range to match the application objective. This is easily accomplished by adjusting the output resistor, which sets the sensor’s gain. LX1972A ® TM Ambient Light Detector P RODUCTION D ATA S HEET APPLICATION EXAMPLES 3.3V or 5V The output node will actually reach 1.25V when the source current from the LX1972A is only about 43µA, since about 7µA of current will be contributed from R1. This assumes a high impedance input to the LED driver. In Figure 5 user adjustable bias control has been added to allow control over the minimum and maximum output voltage. This allows the user to adjust the output brightness to personal preference over a limited range. In addition, an equivalent DC voltage may replace the PWM input source. 3.3V or 5V VDD Part VSS 3.3V PWM R1 40K VDD Part VSS R1 C1 10µF R2 ⎡ 3.3V ∴ R1= R2 ⎢ ⎣ 0.25V CMOS Gate VDD Part VSS 60K 3.3V PWM 30K 10µF 30K To inverter brightness input or LED driver controller. ⎤ −1⎥ = 12.2×R2 ⎦ Next, the value of R2 can be calculated based on the maximum output source current coming from the LX1972A under the application’s maximum light exposure, lets say this has been determined to be about 50µA . Thus R2 can be calculated first order as follows: ⎡ 1.25V ⎤ ⎥ = 25k ⎢⎣ 50µA ⎥⎦ Figure 6 shows how a fully manual override can be quickly added to the example in figure 5. In addition to the gate to turn on and off the LX1972A, a diode has been inserted to isolate the sensor when it is disabled. ∴R1 = 12.2 × R2 = 305k Figure 6 The preceding examples represent just a few of the potential sensor applications. Further details and additional circuits can be found in the application note (AN-28) LX1970 Visible Light Sensor located in the application section of www.microsemi.com. Although this application note is written around Microsemi’s LX1970 visible light sensor, the circuits can be easily adapted for use with the LX1972A. Microsemi Integrated Products Group 11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 Page 6 APPLICATIONS The example in figure 4 shows a fully automatic dimming solution with no user interaction. Choose R1 and R2 values for any desired minimum brightness and slope. Choose C1 to adjust response time to filter 50/60 Hz room lighting. As an example, let’s say you wish to generate an output voltage from 0.25V to 1.25V to drive the input of an LED driver controller. The 0.25V represents the minimum LED brightness and 1.25V represents the maximum. The first step would be to determine the ratio of R1 and R2. Copyright © 2005 Rev. 1.0, 2006-09-18 R2 25K Disable control Figure 4 R2 = ⎢ To inverter brightness input or LED driver 10µF controller input. Figure 5 To inverter brightness input or LED driver controller. 3.3V R2 × 3.3 = 0.25 R1+ R2 WWW . Microsemi .C OM The following examples present both fully automatic (no user input) and semi-automatic to fully manual override implementations. These general guidelines are applicable to a wide variety of potential light control applications. The LX1972A can be used to control the brightness input of CCFL inverters (like Microsemi’s PanelMatch™ inverter family, or line of controller IC’s). Likewise, it can interface well with LED drivers like the LX1990 and LX1991 sink LED drivers, or boost drivers like the LX1992, LX1993, LX1994, and LX1995. In each specific application, it is important to recognize the need to correlate the output current of the LX1972A for the target environment and its ambient light conditions. The mechanical mounting of the sensor, light aperture hole size, use of a light pipe or bezel are critical in determining the response of the LX1972A for a given exposure of light. LX1972A ® TM Ambient Light Detector P RODUCTION D ATA S HEET APPLICATION CIRCUITS WWW . Microsemi .C OM D1 UPS5817 L1 10µH VIN IN GND C2 1µF SW SHDN C1 4.7µF BACKLIGHT LX1995 R1 100K FB GND R5 5.76K SHDN R4 10K R7 24.9K MMBT2907 R8 60.4K 3.3V LX1972A VSS R6 15 C3 10µF R10 49.9K C4 0.1µF VDD Figure 7 – Typical Application with Microsemi’s LX1995 LED Driver IC 22µH UPS5819 VIN = 2.0V to 5.5V FDN337 PWM Dimming Input 3.3V 4.99K LX1972A VDD VSS MMBT2907 15K VIN DRV S/P SRC BRT OVP LS GND 22µF 100K 1µF LX1994 1µF 1M FB CMP 0.1µF 41.2K 15 APPLICATIONS 178K Figure 8 – Typical Application with Microsemi’s LX1994 LED driver IC Copyright © 2005 Rev. 1.0, 2006-09-18 Microsemi Integrated Products Group 11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 Page 7 LX1972A ® TM Ambient Light Detector P RODUCTION D ATA S HEET PACKAGE DIMENSIONS 2-Pin 1206 Standard Carrier D Dim A B D E H M P R X Sensor Active Area: 0.2 x 0.2mm CL 2 P C CL C R 0.03 2 1 Top E Sensor Active Area θ 0.19 - 0.25mm B A 1 Bottom H WWW . Microsemi .C OM BC Side X Pin 1 Indicator (top side) / Alignment Indicator (Bottom side) MILLIMETERS MIN MAX 0.95 1.25 0.40 0.70 3.05 3.35 1.85 2.15 0.40 0.60 3° nom 1.45 1.75 0.25 nom 0.02 0.05 INCHES MIN MAX 0.037 0.049 0.016 0.028 0.120 0.132 0.073 0.085 0.016 0.024 3° nom 0.057 0.069 0.010 nom 0.0008 0.002 Note: Dimensions do not include protrusions; these shall not exceed 0.155mm (.006”) on any side. Recommended Soldering Pattern for reflow soldering of the BC (1206) package. 1.50mm 0.06in. 1.50mm 0.06in. 2.0mm 0.08in. 1.50mm 0.06in. Super Imposed 1206 Package Basic specification is < 5 seconds @ 260°C when applying solder. Lead In: 10 min empty Loaded: 3000 pcs Lead Out: 40 min empty 4.00 1.75 5.25 8.00 MECHANICALS 0.20 2.00 4.00 1.30 Copyright © 2005 Rev. 1.0, 2006-09-18 Microsemi Integrated Products Group 11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 Page 8 LX1972A TM ® Ambient Light Detector P RODUCTION D ATA S HEET NOTES WWW . Microsemi .C OM NOTES PRODUCTION DATA – Information contained in this document is proprietary to Microsemi and is current as of publication date. This document may not be modified in any way without the express written consent of Microsemi. Product processing does not necessarily include testing of all parameters. Microsemi reserves the right to change the configuration and performance of the product and to discontinue product at any time. Copyright © 2005 Rev. 1.0, 2006-09-18 Microsemi Integrated Products Group 11861 Western Avenue, Garden Grove, CA. 92841, 714-898-8121, Fax: 714-893-2570 Page 9