NSC LM95235DIMMX

LM95235/LM95235Q
Precision Remote Diode Temperature Sensor with SMBus
Interface and TruTherm™ Technology
General Description
■ Diode Model Selection Bit - MMBT3904 or 65/90 nm
The LM95235 is an 11-bit digital temperature sensor with a
2-wire System Management Bus (SMBus) interface and
TruTherm technology that can monitor the temperature of a
remote diode as well as its own temperature. The LM95235
can be used to very accurately monitor the temperature of
external devices such as microprocessors, graphics processors, or a diode-connected MMBT3904 transistor. For automotive applications the LM95235Q is available that is AECQ100 Grade3 compliant and is manufactured on an
Automotive Grade Flow. TruTherm BJT (transistor) beta compensation technology allows the LM95235 to precisely monitor thermal diodes found in 90 nm and smaller geometry
processes. LM95235 reports temperature in two different formats for +127.875°C/-128°C range and 0°C/255°C range.
The LM95235 T_CRIT and OS outputs are asserted when
either unmasked channel exceeds its programmed limit and
can be used to shutdown the system, to turn on the system
fans, or as a microcontroller interrupt function. The current
status of the T_CRIT and OS pins can be read back from the
status registers via the SMBus interface. All limits have a
shared programmable hysteresis register.
The remote temperature channel of the LM95235 has a programmable digital filter. The LM95235 contains a diode model
selection bit to select between a typical Intel® processor on
a 65 nm or 90 nm process or MMBT3904, as well as an offset
register for maximum flexibility and best accuracy.
The LM95235 has a three-level address pin to connect up to
3 devices to the same SMBus master, that is shared with the
OS output. The LM95235 has a programmable conversion
rate register and a standby mode to save power. One conversion can be triggered in standby mode by writing to the
one-shot register.
■
Features
■ Processor/Computer System Thermal Management
■ Remote and Local temperature channels
■ TruTherm BJT beta compensation technology
■ LM95235Q is AEC-Q100 Grade 3 compliant and is
■
■
■
■
■
■
■
■
■
■
■
processor diodes
Two Formats: −128°C to 127.875°C and
0°C to 255.875°C
Digital filter for remote channel
Programmable TCRIT and OS thresholds
Programmable shared hysteresis register
Diode Fault Detection
Mask, Offset, and Status Registers
SMBus 2.0 compatible interface, supports TIMEOUT
Programmable conversion rate for best power
consumption
Three-level address pin
Standby mode one-shot conversion control
Pin-for-pin compatible with the LM86/LM89
8-pin MSOP package
Key Specifications
■ Supply Voltage
■ Supply Current, Conv. Rate = 1 Hz
■ Remote Diode Temperature Accuracy
TA = 25°C to 85°C; TD = 60°C to 100°C
TA = 25°C to 85°C; TD = 40°C to 125°C
■ Local Temperature Accuracy
TA = 25°C to 100°C
■ Conversion Rate, Both Channels
3.0 V to 3.6 V
350 µA (typ)
±0.75°C (max)
±1.5°C (max)
±2.0°C (max)
16 to 0.4 Hz
Applications
(e.g. Laptops, Desktops, Workstations, Servers)
Electronic
Test Equipment and Office Electronics
■
manufactured on an Automotive Grade Flow
Connection Diagram
MSOP-8
20174902
TOP VIEW
TruTherm™ is a trademark of National Semiconductor Corporation.
Intel® is a registered trademark of Intel Corporation.
Pentium® is a registered trademark of Intel Corporation.
© 2008 National Semiconductor Corporation
201749
www.national.com
LM95235/LM95235Q Precision Remote Diode Temperature Sensor with SMBus Interface and
TruTherm Technology
August 15, 2008
LM95235/LM95235Q
Ordering Information
Order Code
LM95235CIMM
LM95235CIMMX
LM95235DIMM
LM95235DIMMX
LM95235EIMM
LM95235EIMMX
LM95235QEIMM
LM95235QEIMMX
Packag
e
NS Package
Markin
Number
g
Transport Media
Features
TA = 25°C to 85°C
T36C
MUA08A
(MSOP-8)
1000 Units on Tape and Reel
T36C
MUA08A
(MSOP-8)
3500 Units on Tape and Reel
T36D
MUA08A
(MSOP-8)
1000 Units on Tape and Reel
T36D
MUA08A
(MSOP-8)
3500 Units on Tape and Reel
T36E
MUA08A
(MSOP-8)
1000 Units on Tape and Reel
T36E
MUA08A
(MSOP-8)
3500 Units on Tape and Reel
36QE
MUA08A
(MSOP-8)
1000 Units on Tape and Reel
36QE
MUA08A
(MSOP-8)
3500 Units on Tape and Reel
TA = -40°C to 85°C,
TD = -40°C to 125°C
TA = -40°C to 85°C,
TD = -40°C to 125°C, 3904 only
TA = -40°C to 85°C,
TD = -40°C to 125°C, 3904 only
AEC-Q100 Grade 3 Compiant with
Automotive Grade Flow
Simplified Block Diagram
20174901
www.national.com
2
Pin
Number
Name
Type
Function and Connection
1
VDD
Power
Device power supply. Requires bypass capacitor of 10 µF in parallel with 0.1
µF and 100 pF. Place 100 pF closest to device pin.
2
D+
Analog Input/Output Positive input from the thermal diode.
3
D-
Analog Input/Output Negative input from the thermal diode.
4
T_CRIT
Digital Output
5
GND
Ground
Critical temperature output. Open-drain output requires pull-up resistor.
Active “LOW”.
Device ground.
6
OS/A0
Digital Input/Output
Over-temperature shutdown comparator output or SMBus slave address
input. Defaults as an SMBus slave address input that selects one of three
addresses. Can be tied to VDD, GND, or to the middle of a resistor divider
connected between VDD and GND. When programmed as an OS comparator
output it is active “Low” and open drain.
7
SMBDAT
Digital Input/Output
SMBus interface data pin. Open-drain output requires pull-up resistor.
8
SMBCLK
Digital Input
SMBus interface clock pin.
Typical Application
20174903
3
www.national.com
LM95235/LM95235Q
Pin Descriptions
LM95235/LM95235Q
Absolute Maximum Ratings (Note 1)
Operating Ratings
Supply Voltage, VDD
Voltage at SMBDAT, SMBCLK,
(Note 1)
−0.3V to 6.0V
−0.5V to 6.0V
T_CRIT, OS/A0 Pins
Voltage at Other Pins
Input Current at D− Pin (Note 4)
Input Current at All Other Pins
(Note 4)
Output Sink Current
SMBDAT, T_Crit, OS Pins
Package Input Current (Note 4)
ESD Susceptibility (Note 3)
Human Body Model
Machine Model
Charged Device Model
Operating Temperature Range
Electrical Characteristics
Temperature Range
LM95235CIMM
(VDD +0.3V)
±1 mA
LM95235DIMM
±5 mA
LM95235EIMM, LM95235QEIMM
Supply Voltage (VDD)
10 mA
30 mA
TMIN ≤ TA ≤ TMAX
0°C ≤ TA ≤ +85°C
-40°C ≤ TA ≤ +85°C
-40°C ≤ TA ≤ +85°C
+3.0V to +3.6V
Soldering
process
must
comply
with
National
Semiconductor's Reflow Temperature Profile specifications.
Refer to www.national.com/packaging. (Note 5)
2500V
250V
1000V
+125°C
−65°C to +150°C
Junction Temperature (Note 2)
Storage Temperature
-40°C to +125°C
Temperature-to-Digital Converter Characteristics
Unless otherwise noted, these specifications apply for VDD = +3.0 Vdc to 3.6 Vdc. Boldface limits apply for TA = TJ =
TMIN ≤ TA ≤ TMAX; all other limits TA = TJ = +25°C, unless otherwise noted. TJ is the junction temperature of the LM95235. TA is
the ambient temperature of the LM95235. TD is the junction temperature of the remote thermal diode.
Parameter
Conditions
Temperature Accuracy
TA = 25°C to +100°C
Using Local Diode (Note 8) T = -40°C to +25°C
A
Temperature Accuracy
Using Remote Diode
(Note 9)
Remote Diode
Measurement Resolution
www.national.com
LM95235
CIMM
Limits
(Note 7)
±1
±2
LM95235
DIMM/
Limits
(Note 7)
LM95235
EIMM
LM95235
QEIMM
Limits
(Note 7)
Units
±2
±2
°C (max)
±6.0
±6.0
°C (max)
TA = +25°C to +85°C;
TD = +60°C to +100°C
65nm Intel
Processor
±0.5
±0.75
±0.75
±0.75
°C (max)
TA = +25°C to +85°C;
TD = +60°C to +100°C
MMBT3904
±0.5
±1.0
±1.0
±1.0
°C (max)
TA = +25°C to +85°C;
TD = +40°C to +120°C
MMBT3904 or
65nm Intel
Processor
±0.75
±1.5
±1.5
±1.5
°C (max)
TA = -40°C to +25°C;
TD = +25°C to +125°C
MMBT3904 or
65nm Intel
Processor
TA = -40°C to +25°C;
TD = +25°C to +125°C
MMBT3904
TA = -40°C to +25°C;
TD = -40°C to +25°C
MMBT3904
Digital Filter Off
Digital Filter On
Local Diode Measurement
Resolution
Conversion Time, Fastest
Setting (Note 10)
Typical
(Note 6)
°C (max)
±3.0
±5.0
±3.0
°C (max)
±5.0
°C (max)
11
Bits
0.125
°C
13
Bits
0.03125
°C
11
Bits
0.125
Local and Remote Channels
63
Local or Remote Channels
33
4
°C
72
72
72
ms (max)
ms
Conditions
Quiescent Current
Typical
(Note 6)
LM95235
CIMM
Limits
(Note 7)
LM95235
DIMM/
Limits
(Note 7)
LM95235
EIMM
LM95235
QEIMM
Limits
(Note 7)
Units
SMBus Inactive, 1 Hz conversion rate
(Note 11)
350
650
650
650
µA (max)
Standby Mode
300
µA
400
mV
D− Source Voltage
External Diode Current
Source
High-level
172
Low-level
10.75
Diode Source Current Ratio
225
225
225
µA (max)
µA
16
Power-On Reset Voltage
2.8
2.8
2.8
V (max)
1.6
1.6
1.6
V (min)
T_CRIT Pin Temperature
Threshold
Default
+110
°C
OS Pin Temperature
Threshold
Default
+85
°C
Logic Electrical Characteristics
Digital DC Characteristics
Unless otherwise noted, these specifications apply for VDD= +3.0 Vdc to 3.6 Vdc. Boldface limits apply for TA = TJ = TMIN to
TMAX; all other limits TA= TJ= +25°C, unless otherwise noted.
Symbol
Parameter
Conditions
Typical
(Note 6)
Limits
(Note 7)
Units
(Limit)
2.1
V (min)
0.8
V (max)
SMBDAT, SMBCLK INPUTS
VIN(1)
Logical “1” Input Voltage
VIN(0)
Logical “0” Input Voltage
VIN(HYST)
SMBDAT and SMBCLK Digital Input Hysteresis
IIN(1)
Logical “1” Input Current
VIN = VDD
−0.005
−10
µA (max)
IIN(0)
Logical “0” Input Current
VIN = 0 V
0.005
+10
µA (max)
CIN
Input Capacitance
400
mV
5
pF
A0 DIGITAL INPUT
VIH
Input High Voltage
VIM
Input Middle Voltage
VIL
Input Low Voltage
0.10 × VDD
V (max)
IIN(1)
Logical “1” Input Current
VIN = VDD
−0.005
−10
µA (max)
IIN(0)
Logical “0” Input Current
VIN = 0 V
0.005
+10
µA (max)
CIN
Input Capacitance
0.90 × VDD
V (min)
0.57 × VDD
V (max)
0.43 × VDD
V (min)
5
pF
SMBDAT, T_CRIT, OS DIGITAL OUTPUTS
IOH
High Level Output Leakage Current
VOUT = VDD
10
µA (max)
VOL(T_CRIT, OS)
T_CRIT, OS Low Level Output Voltage
IOL = 6 mA
0.4
V (max)
VOL(SMBDAT)
SMBDAT Low Level Output Voltage
IOL = 4 mA
IOL = 6 mA
0.4
0.6
V (max)
V (max)
COUT
Digital Output Capacitance
5
5
pF
www.national.com
LM95235/LM95235Q
Parameter
LM95235/LM95235Q
SMBus Digital Switching Characteristics
Unless otherwise noted, these specifications apply for VDD= +3.0 Vdc to +3.6 Vdc, CL (load capacitance) on output lines = 80 pF.
Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = +25°C, unless otherwise noted.
The switching characteristics of the LM95235 fully meet or exceed the published specifications of the SMBus version 2.0. The
following parameters are the timing relationships between SMBCLK and SMBDAT signals related to the LM95235. They adhere
to, but are not necessarily, the SMBus specifications.
Symbol
Parameter
Conditions
Typical Limits
(Note 6) (Note 7)
Units
(Limit)
100
10
kHz
(max)
kHz (min)
4.7
25
µs (min)
ms (max)
fSMB
SMBus Clock Frequency
tLOW
SMBus Clock Low Time
from VIN(0)max to VIN(0)max
tHIGH
SMBus Clock High Time
from VIN(1)min to VIN(1)min
tR,SMB
SMBus Rise Time
(Note 12)
1
µs (max)
tF,SMB
SMBus Fall Time
(Note 13)
0.3
µs (max)
tOF
Output Fall Time
CL = 400 pF,
IO = 3 mA, (Note 13)
tTIMEOUT
tSU;DAT
4.0
µs (min)
250
ns (max)
SMBDAT and SMBCLK Time Low for Reset of Serial
Interface (Note 14)
25
35
ms (min)
ms (max)
Data In Setup Time to SMBCLK High
250
ns (min)
tHD;DAT
Data Out Stable after SMBCLK Low
300
1075
ns (min)
ns (max)
tHD;STA
Start Condition SMBDAT Low to SMBCLK Low (Start
condition hold before the first clock falling edge)
100
ns (min)
tSU;STO
Stop Condition SMBCLK High to SMBDAT Low (Stop
Condition Setup)
100
ns (min)
tSU;STA
SMBus Repeated Start-Condition Setup Time,
SMBCLK High to SMBDAT Low
0.6
µs (min)
tBUF
SMBus Free Time Between Stop and Start Conditions
1.3
µs (min)
SMBus Communication
20174909
www.national.com
6
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
guaranteed to be functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics.
The guaranteed specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under
the listed test conditions. Operation of the device beyond the maximum Operating Ratings is not recommended.
Note 2: Thermal resistance junction-to-ambient when attached to a printed circuit board with 1 oz. foil and no airflow is:
θJA for MSOP-8 package = 210°C/W
Note 3: Human body model (HBM) is a charged 100 pF capacitor discharged into a 1.5 kΩ resistor. Machine model (MM), is a charged 200 pF capacitor discharged
directly into each pin. Charged Device Model (CDM) simulates a pin slowly acquiring charge (such as from a device sliding down the feeder in an automated
assembler) then rapidly being discharged.
Note 4: When the input voltage (VI) at any pin exceeds the power supplies (VI < GND or VI > VDD), the current at that pin should be limited to 5 mA.
Parasitic components and or ESD protection circuitry are shown in the figures below for the LM95235's pins. Care should be taken not to forward bias the parasitic
diodes on pins 2 and 3. Doing so by more than 50 mV may corrupt the temperature measurements. SNP refers to Snap-back device.
Pin #
Label
Circuit
1
VDD
A
2
D+
A
3
D−
A
4
T_CRIT
B
5
GND
A
6
OS/A0
B
7
SMBDAT
B
8
SMBCLK
B
Pin ESD Protection Structure Circuits
Circuit B
Circuit A
Note 5: Reflow temperature profiles are different for packages containing lead (Pb) than for those that do not.
Note 6: Typical figures are at TA = 25°C and represent most likely parametric norms at the time of product characterization. The typical specifications are not
guaranteed.
Note 7: Limits are guaranteed to National's AOQL (Average Outgoing Quality Level).
Note 8: Local temperature accuracy does not include the effects of self-heating. The rise in temperature due to self-heating is the product of the internal power
dissipation of the LM95235 and the thermal resistance. See (Note 2) for the thermal resistance to be used in the self-heating calculation.
Note 9: The accuracy of the LM95235 is guaranteed when using a typical thermal diode of an Intel processor on a 65 nm process or an MMBT3904 diodeconnected transistor, as selected in the Remote Diode Model Select register. See typical performance curve for performance with Intel processor on a 90nm
process.
Note 10: This specification is provided only to indicate how often temperature data is updated. The LM95235 can be read at any time without regard to conversion
state (and will yield last conversion result).
Note 11: Quiescent current will not increase substantially when the SMBus is active.
Note 12: The output rise time is measured from (VIN(0)max - 0.15V) to (VIN(1)min + 0.15V).
Note 13: The output fall time is measured from (VIN(1)min + 0.15V) to (VIN(0)max - 0.15V).
Note 14: Holding the SMBDAT and/or SMBCLK lines Low for a time interval greater than tTIMEOUT will reset the LM95235's SMBus state machine, therefore setting
SMBDAT and SMBCLK pins to a high impedance state.
7
www.national.com
LM95235/LM95235Q
Notes
LM95235/LM95235Q
Typical Performance Characteristics
Thermal Diode Capacitor or PCB Leakage Current Effect
Remote Diode Temperature Reading
Remote Temperature Reading Sensitivity to Thermal Diode
Filter Capacitance, TruTherm Enabled
20174905
20174907
Conversion Rate Effect on Average Power Supply Current
Intel Processor on 65nm Process or 90nm Process
Thermal Diode Performance Comparison
20174906
20174950
www.national.com
8
The LM95235 is a temperature sensor that measures Local
and Remote temperature zones. The LM95235 uses a ΔVbe
temperature sensing method. A differential voltage, representing temperature, is digitized using a Sigma-Delta analog
to digital converter. TruTherm Technology allows the
LM95235 to accurately sense the temperature of a thermal
diode found on die fabricated using a sub-micron process. For
more information on TruTherm Technology see Section 3.0
Application Hints. The LM95235 is compatible with the serial
SMBus version 2.0 two-wire serial interface.
The LM95235 has OS and TCRIT open-drain digital outputs
that indicate the state of the local and remote temperature
readings when compared to user-programmable limits. If enabled, the local temperature is compared to the user-programmable Local Shared OS and TCRIT Limit Register
(Default Value = 85°C). The comparison result can trigger the
T_CRIT pin and/or the OS pin depending on the settings of
the Local TCRIT Mask and OS Mask bits found in Configuration Register 1. The comparison result can also be read
back from Status Register 1. If enabled, the remote temperature is compared to the user-programmable Remote TCRIT
Limit Register (Default Value = 110°C), and the Remote OS
Limit Register (Default Value = 85°C) values. The comparison
result can trigger the T_CRIT pin and/or the OS pin depending
on the settings of Configuration Register 1. The following table describes the default temperature settings for each measured temperature that triggers T_CRIT and/or OS pins:
Output Pin
Remote, °C
Local, °C
T_CRIT
110
85
OS
85
85
1.1 CONVERSION SEQUENCE
In the power-up default state the LM95235 takes a maximum
of 1 second to convert the Local Temperature, Remote Temperature, and to update all of its registers. Only during the
conversion process is the Busy bit (D7) in Status Register 1
(02h) high. These conversions are addressed in a round-robin
sequence. The conversion rate may be modified by the Conversion Rate bits found in the Conversion Rate Register (R/
W: 04h/0Ah). When the conversion rate is modified a delay is
inserted between conversions, the actual maximum conversion time remains at 72 ms. Different conversion rates will
cause the LM95235 to draw different amounts of supply current as shown in Figure 1.
The following table describes the limit register mapping to the
T_CRIT and/or OS pins:
Output Pin
Remote
Local
T_CRIT
Remote
TCRIT Limit
Local Shared OS/TCRIT
Limit
OS
Remote OS
Limit
Local Shared OS/TCRIT
Limit
The T_CRIT and OS outputs are open-drain, active low.
The remote temperature readings support a programmable
digital filter. Based on the settings in Configuration Register
2 a digital filter can be turned on to improve the noise performance of the remote temperature as well as to increase the
resolution of the temperature reading. If the filter is enabled
the filtered readings are used for TCRIT and OS comparisons.
The LM95235 may be placed in low power consumption
(Standby) mode by setting the STOP/RUN bit found in Configuration Register 1. In the Standby mode, the LM95235’s
SMBus interface remains active while all circuitry not required
is turned off. In the Standby mode the host can trigger one
round of conversions by writing to the One-Shot Register. The
value written into this register is not kept. Local and Remote
temperatures will be converted once and the T_CRIT and
OS pins will reflect the comparison results based on this set
of conversions results.
All the temperature readings are in 16-bit left-justified word
format. The 10-bit plus sign local temperature reading is contained in two 8-bit registers: Local Temp MSB and Local Temp
LSB Registers. The remote temperature supports both a 13bit unsigned and a 12-bit plus sign format. These readings are
available in their corresponding registers as described in the
20174906
FIGURE 1. Conversion Rate Effect on Power Supply
Current
1.2 POWER-ON-DEFAULT STATES
LM95235 always powers up to these known default states.
The LM95235 remains in these states until after the first conversion.
1. Command Register set to 00h
2. Conversion Rate register defaults to 02h (1 second).
3. Local Temperature set to 0°C until the end of the first
conversion
4. Remote Diode Temperature set to 0°C until the end of
the first conversion
5. Remote OS limit default is 55h (85 °C).
6. Local Shared and TCRIT limit default is 55h (85 °C).
7. Remote TCRIT limit default is 6Eh (110 °C).
8. Remote Offset High and Low bytes default to 00h.
9
www.national.com
LM95235/LM95235Q
LM95235 Register table. The lower 2-bits of the remote temperature reading will contain temperature information only if
the digital filter is enabled. If the digital filter is disabled, these
two bits will read back 0.
The signed and unsigned remote temperature readings are
available simultaneously in separate registers, therefore allowing both negative temperatures and temperatures 128°C
and above to be measured.
All Limit Registers support unsigned temperature format with
1°C LSb resolution. The Local Shared TCRIT and OS Limit
Register is 7 bits for limits between 0°C and 127°C. The Remote Temperature TCRIT and OS Limit Registers are 8 bits
each for limits between 0°C and 255°C.
1.0 Functional Description
LM95235/LM95235Q
9.
Figure 2 depicts the filter output in response to a step input
and an impulse input.
Configuration Register 1 defaults to 00h. This sets the
LM95235 as follows:
A.
The STOP/RUN defaults to the active/converting
mode.
B. The Local and Remote TCRIT and OS Masks are
reset to 0.
10. Configuration Register 2 defaults to 1Fh. This sets the
LM95235 as follows:
A.
B.
C.
D.
E.
Remote Diode digital filter defaults on.
The Remote Diode mode defaults to a typical Intel
processor on 65/90 nm process.
Diode Fault Mask bit for TCRIT defaults to 1.
Diode Fault Mask bit for OS defaults to 0.
Pin 6 Function defaults to Address Input function
(A0).
20174925
a) Seventeen and fifty degree step response
1.3 SMBus INTERFACE
The LM95235 operates as a slave on the SMBus, so the
SMBCLK line is an input and the SMBDAT line is bidirectional.
The LM95235 never drives the SMBCLK line and it does not
support clock stretching. According to SMBus specifications,
the LM95235 has a 7-bit slave address. Three SMBus addresses can be selected by connecting pin 6 (A0) to either
Low, Mid-Supply or High voltages. The address selection table below shows the possible selections.
SMBus Device Address
State of the A0 Pin
HEX
Binary
Low
18
001 1000
Mid-Supply
29
010 1001
High
4C
100 1100
20174926
b) Impulse response with input transients less than 4°C
The OS/A0 pin, after power-up, defaults as an address select
input pin (A0). After power-up, the OS/A0 pin can only be
programmed as an OS output when it is in the “High” state.
Therefore, 4Ch is the only valid slave address that can be
used when the OS/A0 pin is programmed to function as an
OS output. When the OS/A0 pin is programmed to function
as an A0 input the LM95235 will immediately detect the state
of this pin to determine its SMBus slave address. The
LM95235 does not latch the state of the A0 pin when it is
functioning as an input.
1.4 DIGITAL FILTER
In order to suppress erroneous remote temperature readings
due to noise, the LM95235 incorporates a digital filter for the
Remote Temperature Channel. The filter is accessed in the
Configuration Register 2, bits D2 (FE1) and D1(FE0). The filter can be set according to the following table.
FE1
FE0
0
0
Filter Setting
Filter Off
0
1
Reserved
1
0
Reserved
1
1
Filter On
20174928
c) Impuse response with input transients greater than 4°
C
FIGURE 2. Filter Impulse and Step Response Curves
Figure 3 shows the filter in use in a typical Intel processor on
a 65/90 nm process system. Note that the two curves have
been purposely offset for clarity. Inserting the filter does not
induce an offset as shown.
www.national.com
10
20174927
Digital Output
Hex
0111 1101 0000 0000
7D00h
+25°C
0001 1001 0000 0000
1900h
+1°C
0000 0001 0000 0000
0100h
+0.125°C
0000 0000 0010 0000
0020h
0°C
0000 0000 0000 0000
0000h
−0.125°C
1111 1111 1110 0000
FFE0h
−1°C
1111 1111 0000 0000
FF00h
−25°C
1110 0111 0000 0000
E700h
−55°C
1100 1001 0000 0000
C900h
Hex
+255.875°C
1111 1111 1110 0000
FFE0h
+255°C
1111 1111 0000 0000
FF00h
+201°C
1100 1001 0000 0000
C900h
+125°C
0111 1101 0000 0000
7D00h
+25°C
0001 1001 0000 0000
1900h
+1°C
0000 0001 0000 0000
0100h
+0.125°C
0000 0000 0010 0000
0020h
0°C
0000 0000 0000 0000
0000h
0001 1001 0000 0000
1900h
+1°C
0000 0001 0000 0000
0100h
+0.03125°C
0000 0000 0000 1000
0008h
0°C
0000 0000 0000 0000
0000h
−0.03125°C
1111 1111 1111 1000
FFF8h
−1°C
1111 1111 0000 0000
FF00h
−25°C
1110 0111 0000 0000
E700h
−55°C
1100 1001 0000 0000
C900h
Digital Output
Binary
Hex
+255.875°C
1111 1111 1110 0000
FFE0h
+255°C
1111 1111 0000 0000
FF00h
+201°C
1100 1001 0000 0000
C900h
+125°C
0111 1101 0000 0000
7D00h
+25°C
0001 1001 0000 0000
1900h
+1°C
0000 0001 0000 0000
0100h
+0.03125°C
0000 0000 0000 1000
0008h
0°C
0000 0000 0000 0000
0000h
11-bit, 2's complement (10-bit plus sign)
Digital Output
Binary
+25°C
Temperature
11-bit, unsigned binary
Temperature
7D00h
Local Temperature data is represented by a 10-bit plus sign,
two's complement word with an LSb (Least Significant Bit)
equal to 0.125°C. The data format is a left justified 16-bit word
available in two 8-bit registers. Unused bits will always report
"0". Local temperature readings greater than +127.875°C are
clamped to +127.875°C, they will not roll-over to negative
temperature readings.
11-bit, 2's complement (10-bit plus sign)
+125°C
Hex
0111 1101 0000 0000
Temperature
1.5 TEMPERATURE DATA FORMAT
Temperature data can only be read from the Local and Remote Temperature registers.
Remote temperature data with the digital filter off is represented by an 10-bit plus sign, two's complement word and 11bit unsigned binary word with an LSb (Least Significant Bit)
equal to 0.125°C. The data format is a left justified 16-bit word
available in two 8-bit registers. Unused bits report "0".
Remote temperature data with the digital filter on is represented by a 12-bit plus sign, two's complement word and 13bit unsigned binary word with an LSb (Least Significant Bit)
equal to 0.03125°C (1/32°C). The data format is a left justified
16-bit word available in two 8-bit registers. Unused bits report
"0".
Binary
Binary
+125°C
13-bit, unsigned binary
FIGURE 3. Digital Filter Response in a typical Intel
processor on a 65 nm or 90 nm process. The filter curves
were purposely offset for clarity.
Temperature
Digital Output
Digital Output
Binary
Hex
+125°C
0111 1101 0000 0000
7D00h
+25°C
0001 1001 0000 0000
1900h
+1°C
0000 0001 0000 0000
0100h
+0.125°C
0000 0000 0010 0000
0020h
0°C
0000 0000 0000 0000
0000h
−0.125°C
1111 1111 1110 0000
FFE0h
−1°C
1111 1111 0000 0000
FF00h
−25°C
1110 0111 0000 0000
E700h
−55°C
1100 1001 0000 0000
C900h
1.6 SMBDAT OPEN-DRAIN OUTPUT
The SMBDAT output is an open-drain output and does not
have internal pull-ups. A “high” level will not be observed on
this pin until pull-up current is provided by some external
source, typically a pull-up resistor. Choice of resistor value
depends on many system factors but, in general, the pull-up
resistor should be as large as possible without effecting the
SMBus desired data rate. This will minimize any internal temperature reading errors due to internal heating of the
LM95235. The maximum resistance of the pull-up to provide
a 2.1V high level, based on LM95235 specification for High
11
www.national.com
LM95235/LM95235Q
13-bit, 2's complement (12-bit plus sign)
Temperature
LM95235/LM95235Q
Level Output Current with the supply voltage at 3.0V, is
82 kΩ (5%) or 88.7 kΩ (1%).
1.7 T_CRIT OUTPUT AND TCRIT LIMIT
The LM95235's T_CRIT pin is an active-low open-drain output that is triggered when the local and/or the remote temperature conversion is above the limits defined by the Remote
and/or Local Limit registers. The state of the T_CRIT pin will
return to the HIGH state when both the Local and Remote
temperatures are below the values programmed into the Limit
Registers less the value in the Common Hysteresis Register.
Additionally, if the remote temperature exceeds the value in
the Remote TCRIT Limit Register the Status Bit for Remote
TCRIT (RTCRIT), in Status Register 1, is set to 1. In the same
way if the local temperature exceeds the value in the Local
Shared OS and TCRIT Limit Register the Status Bit for the
Shared Local OS and TCRIT (LOC) bit in Status Register 1 is
set to 1.The T_CRIT output and the Status Register flags are
updated after every Local and Remote temperature conversion. See Figure 4
20174915
FIGURE 5. OS Temperature Response Diagram
1.9 DIODE FAULT DETECTION
The LM95235 is equipped with operational circuitry designed
to detect fault conditions concerning the remote diodes. In the
event that the D+ pin is detected as shorted to GND, D−,
VDD or D+ is floating, the Remote Temperature reading is –
128.000 °C if signed format is selected and +255.875 °C if
unsigned format is selected. In addition, the Status Register
1 bit D2 is set.
1.10 COMMUNICATING with the LM95235
The data registers in the LM95235 are selected by the Command Register. At power-up the Command Register is set to
“00”, the location for the Read Local Temperature Register.
The Command Register latches the last location it was set to.
Each data register in the LM95235 falls into one of four types
of user accessibility:
1. Read only
2. Write only
3. Write/Read same address
4. Write/Read different address
A Write to the LM95235 will always include the address byte
and the command byte. A write to any register requires one
data byte.
Reading the LM95235 can take place either of two ways:
1. If the location latched in the Command Register is correct
(most of the time it is expected that the Command
Register will point to one of the Read Temperature
Registers because that will be the data most frequently
read from the LM95235), then the read can simply
consist of an address byte, followed by retrieving the data
byte.
2. If the Command Register needs to be set, then an
address byte, command byte, repeat start, and another
address byte will accomplish a read.
The data byte has the most significant bit first. At the end of
a read, the LM95235 can accept either acknowledge or No
Acknowledge from the Master (No Acknowledge is typically
used as a signal for the slave that the Master has read its last
byte). When retrieving all 11 bits from a previous remote diode
temperature measurement, the master must insure that all 11
bits are from the same temperature conversion. This may be
achieved by reading the MSB register first. The LSB will be
locked after the MSB is read. The LSB will be unlocked after
being read. If the user reads MSBs consecutively, each time
the MSB is read, the LSB associated with that temperature
will be locked in and override the previous LSB value lockedin.
20174913
FIGURE 4. T_CRIT Comparator Temperature Response
Diagram
1.8 OS OUTPUT AND OS LIMIT
The LM95235's OS/A0 pin is selected as an OS digital output
as described in Section 1.3. As an OS pin, it is activated
whenever the local and/or remote temperature conversion is
above the limits defined by the Limit registers. If the remote
temperature exceeds the value in the Remote OS Limit Register the Status Bit for Remote OS (ROS) in Status Register
1 is set to 1. In the same way if the local temperature exceeds
the value in the Local Shared OS and TCRIT Limit Register
the Status Bit for the Shared Local OS and TCRIT (LOC) bit
in Status Register 1 is set to 1. The state of the T_CRIT pin
output will return to the HIGH state when both the Local and
Remote temperatures are below the values programmed into
the Limit Registers less the value in the Common Hysteresis
Register. The OS output and the Status Register flags are
updated after every Local and Remote temperature conversion. See Figure 5.
www.national.com
12
LM95235/LM95235Q
20174911
(a) Serial Bus Write to the Internal Command Register
20174910
(b) Serial Bus Write to the internal Command Register followed by a Data Byte
20174912
(c) Serial Bus byte Read from a Register with the internal Command Register preset to desired value.
20174914
(d) Serial Bus Write followed by a Repeat Start and Immediate Read
FIGURE 6. SMBus Timing Diagrams for Access of Data (Default Address of 4Ch is shown)
13
www.national.com
LM95235/LM95235Q
2.
1.11 SERIAL INTERFACE RESET
In the event that the SMBus Master is RESET while the
LM95235 is transmitting on the SMBDAT line, the LM95235
must be returned to a known state in the communication protocol. This may be done in one of two ways:
1. When SMBDAT is LOW, the LM95235 SMBus state
machine resets to the SMBus idle state if either SMBDAT
or SMBCLK are held low for more than 35 ms (tTIMEOUT).
Note that according to SMBus specification 2.0 all
devices are to timeout when either the SMBCLK or
SMBDAT lines are held low for 25 - 35 ms. Therefore, to
insure a timeout of all devices on the bus the SMBCLK
or SMBDAT lines must be held low for at least 35 ms.
www.national.com
When SMBDAT is HIGH, have the master initiate an
SMBus start. The LM95235 will respond properly to an
SMBus start condition at any point during the
communication. After the start the LM95235 will expect
an SMBus Address address byte.
1.12 ONE-SHOT CONVERSION
The One-Shot register is used to initiate a single conversion
and comparison cycle when the device is in standby mode,
after which the device returns to standby. This is not a data
register and it is the write operation that causes the one-shot
conversion. The data written to this address is irrelevant and
is not stored. A zero will always be read from this register.
14
Command register selects which registers will be read from or written to. Data for this register should be transmitted during the
Command Byte of the SMBus write communication. POR means Power-On Reset.
P0-P7: Command
P7
P6
P5
P4
P3
P2
P1
P0
Command
Register Summary
Register Name
Read
Write
Address Address
(Hex)
(Hex)
No.
of
bits
POR
Read/
Default
Write
(Hex)
Description
TEMPERATURE SIGNED VALUE REGISTERS
Local Temp MSB
0x00
NA
8
−
RO
Supports SMBus byte
Local Temp LSB
0x30
NA
3
−
RO
All unused bits are reported as "0".
Remote Temp MSB –
Signed
0x01
NA
8
−
RO
Supports SMBus byte
Remote Temp LSB –
Signed
0x10
NA
5/3
−
RO
All unused bits are reported as "0".
TEMPERATURE UNSIGNED VALUE REGISTERS
Remote Temp MSB –
Unsigned
0x31
NA
8
−
RO
Supports SMBus byte reads
Remote Temp LSB –
Unsigned
0x32
NA
5/3
−
RO
All unused bits are reported as "0".
DIODE CONFIGURATION REGISTERS
Configuration Register 2
0xBF
0xBF
5
0x1F
R/W
Filter Enable, Diode Model Select, Diode
Fault Mask; Pin 6 OS/A0 function select
Remote Offset
High Byte
0x11
0x11
8
0x00
R/W
2's Complement
Remote Offset
Low Byte
0x12
0x12
3
0x00
R/W
2's Complement
All unused bits are reported as "0".
5
0x00
R/W
STOP/RUN , Remote TCRIT mask,
Remote OS mask, Local TCRIT mask,
Local OS mask
2
0x02
R/W
Continuous or specific settings
GENERAL CONFIGURATION REGISTERS
Configuration Register 1
Conversion Rate
0x03/
0x09
0x09/
0x03
0x04/0x0 0x04/0x0
A
A
NA
0x0F
−
−
WO
A write to this register activates one
conversion if STOP/RUN bit = 1.
Status Register 1
0x02
NA
5
−
RO
Busy bit, and status bits
Status Register 2
0x33
NA
2
−
RO
Not Ready bit, Diode detect bit
Remote OS Limit
0x07/
0x0D
0x0D/
0x07
8
0x55
R/W
Unsigned 0 to 255 °C
Default 85 °C
Local Shared OS and
T_Crit Limit
0x20
0x20
7
0x55
R/W
Unsigned 0 to 127 °C
Default 85 °C
Remote T_Crit Limit
0x19
0x19
8
0x6E
R/W
Unsigned 0 to 255 °C
Default 110 °C
Common Hysteresis
0x21
0x21
5
0x0A
R/W
up to 31°C
One-Shot
STATUS REGISTERS
LIMIT REGISTERS
15
www.national.com
LM95235/LM95235Q
2.0 LM95235 Registers
LM95235/LM95235Q
Register Name
Read
Write
Address Address
(Hex)
(Hex)
No.
of
bits
POR
Read/
Default
Write
(Hex)
Description
IDENTIFICATION REGISTERS
Manufacturer ID
0xFE
0x01
RO
Always returns 0x01
Revision ID
0xFF
0xB1
RO
Returns revision number.
www.national.com
16
LM95235/LM95235Q
2.1 LOCAL and REMOTE MSB and LSB TEMPERATURE REGISTERS
Local Temperature MSB
(Read Only Address 00h)
10-bit plus sign format:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
SIGN
64
32
16
8
4
2
1
Temperature Data: LSb = 1°C.
Local Temperature LSB
(Read Only Address 30h)
10-bit plus sign format:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.5
0.25
0.125
0
0
0
0
0
Temperature Data: LSb = 0.125°C.
Signed Remote Temperature MSB
(Read Only Address 01h)
12-bit plus sign format:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
SIGN
64
32
16
8
4
2
1
Temperature Data: LSb = 1°C.
Signed Remote Temperature LSB, Filter On
(Read Only Address 10h)
12-bit plus sign binary formats with filter on:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.5
0.25
0.125
0.0625
0.03125
0
0
0
Signed Remote Temperature LSB, Filter Off
(Read Only Address 10h)
12-bit plus sign binary formats with filter off:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.5
0.25
0.125
0
0
0
0
0
Temperature Data: LSb = 0.125°C filter off or 0.03125°C filter on.
Unsigned Remote Temperature MSB
(Read Only Address 31h)
13-bit unsigned format:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
128
64
32
16
8
4
2
1
Temperature Data: LSb = 1°C.
Unsigned Remote Temperature LSB, Filter On
(Read Only Address 32h)
13-bit unsigned binary formats with filter on:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.5
0.25
0.125
0.0625
0.03125
0
0
0
17
www.national.com
LM95235/LM95235Q
Unsigned Remote Temperature LSB, Filter Off
(Read Only Address 32h)
13-bit unsigned binary formats with filter off:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.5
0.25
0.125
0
0
0
0
0
Temperature Data: LSb = 0.125°C filter off or 0.03125°C filter on.
For data synchronization purposes, the MSB register should be read first if the user wants to read both MSB and LSB registers.
The LSB will be locked after the MSB is read. The LSB will be unlocked after being read. If the user reads MSBs consecutively,
each time the MSB is read, the LSB associated with that temperature will be locked in and override the previous LSB value lockedin.
2.2 DIODE CONFIGURATION REGISTERS
Configuration Register 2
(Read/write Address BFh):
D7
0
D6
OS/A0 Function Select
Bits
D5
D4
D3
D2
D1
D0
OS Fault Mask
T_CRIT
Mask
TruTherm Select
RFE1
RFE0
1
Name
Description
7
Reserved
Reports "0" when read.
6
OS/A0 Function Select
0: Address (A0) function is enabled
1: Over-temperature Shutdown (OS) is enabled
5
Diode Fault Mask for OS
0: Off
1: On
4
Diode Fault Mask for T_CRIT
0: Off
1: On
3
Remote Diode TruTherm
Mode Select
0: Selects Diode Model 2, MMBT3904, with TruTherm technology
disabled.
1: Selects Diode Model 1, A typical Intel Processor, with 65 nm or 90
nm technology, and TruTherm technology enabled.
Remote Filter Enable
00: Filter Disable
01: Reserved
10: Reserved
11: Filter Enable
Reserved
Reports "1" when read.
2-1
0
Power up default is 1Fh.
Remote Offset High Byte (2's Complement)
(R/W Address 11h)
10-bit plus sign format:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
SIGN
64
32
16
8
4
2
1
Power up default is 00h.
Remote Offset Low Byte (2's Complement)
(R/W Address 12h)
10-bit plus sign format:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0.50
0.25
0.125
0
0
0
0
0
Power up default is 00h. LSb = 0.125 °C.
www.national.com
18
Configuration Register 1
(Read/write Address 03h/09h or 09h/03h):
D7
D6
D5
D4
0
STOP/RUN
0
Remote T_CRIT Mask
Bits
D3
D2
Remote OS Mask Local T_CRIT Mask
Name
Description
7
Reserved
Reports "0" when read.
6
STOP/RUN
0: Active / Converting
1: Standby
5
Reserved
Reports "0" when read.
4
Remote T_CRIT Mask
0: Off
1: On
3
Remote OS Mask
0: Off
1: On
2
Local T_CRIT Mask
0: Off
1: On
1
Local OS Mask
0: Off
1: On
0
Reserved
Reports "0" when read.
D1
D0
Local OS Mask
0
Power up default is 00h.
Conversion Rate Register
(Read/write Address 04h/0Ah or 0Ah/04h):2-bit format:
BIT
D7
D6
D5
D4
D3
D2
D1
D0
Value
0
0
0
0
0
0
MSb
LSb
Bits
Name
7:2
Reserved
1:0
Description
Reports "0" when read.
00: Continuous (33 ms typical when remote
diode is missing or fault or 63 ms typical with
remote diode connected)
Conversion Rate
01: 0.364 seconds
10: 1 second
11: 2.5 seconds
Power up default is 02h (1 second).
One Shot Register
(Write Only Address 0Fh):
Writing to this register will start one conversion if the device is in standby mode (i.e. STOP/RUN bit = 1).
19
www.national.com
LM95235/LM95235Q
2.3 GENERAL CONFIGURATION REGISTERS
LM95235/LM95235Q
2.4 STATUS REGISTERS
Status Register 1
(Read Only Address 02h):
D7
D6
D5
D4
D3
D2
D1
D0
Busy
0
0
ROS
0
Diode Fault
RTCRIT
LOC
Bits
7
Name
Description
Busy
When set to "1" the part is converting.
Reserved
Report "0" when read.
4
ROS
Status Bit for Remote OS
3
Reserved
Reports "0" when read.
Diode Fault
Status bit for missing diode (Either D+ is shorted to GND, and/or VDD, and/or D-; or
D+ is floating.)
Note: The unsigned registers will report 0°C if read; the signed value registers will
report −128.000°C.
1
RTCRIT
Status bit for Remote TCRIT.
0
LOC
Status bit for the shared Local OS and TCRIT .
6-5
2
Status Register 2
(Read Only Address 33h):
D7
D6
D5
D4
D3
D2
D1
D0
Not Ready
TruTherm 3904 Detect
0
0
0
0
0
0
Bits
Name
Description
7
Not Ready
Waiting for 30 ms power-up sequence to end.
6
TruTherm 3904 Detect
1: MMBT3904 is connected and TruTherm technology is enabled.
0: MMBT3904 is connected and TruTherm technology is disabled.
Reserved
Reports "0" when read.
5-0
2.5 LIMIT REGISTERS
Unsigned Remote OS Limit - 0°C to 255°C
(Read/Write Address 07h/0Dh or 0Dh/07h):
D7
D6
D5
D4
D3
D2
D1
D0
128
64
32
16
8
4
2
1
Power on Reset default is 55h (85°C).
Unsigned Local Shared OS and T_CRIT Limit - 0°C to 127°C
(Read/Write Address 20h):
D7
D6
D5
D4
D3
D2
D1
D0
128
64
32
16
8
4
2
1
Power on Reset default is 55h (85°C).
Unsigned Remote T_CRIT Limit - 0°C to 255°C
(Read/Write Address 19h):
D7
D6
D5
D4
D3
D2
D1
D0
128
64
32
16
8
4
2
1
Power on Reset default is 6Eh (110°C).
www.national.com
20
LM95235/LM95235Q
Common Hysteresis Register
(Read/Write Address 21h):
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
16
8
4
2
1
Power on Reset default is 0Ah (10°C).
2.6 IDENTIFICATION REGISTERS
Manufacturers ID Register
(Read Only Address FEh): Always returns 01h.
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
0
0
0
0
1
Revision ID Register
(Read Only Address FFh): Default is B1h. This register will increment by 1 every time there is a revision to the die by National
Semiconductor. The initial revision bits for B1h are shown below.
D7
D6
D5
D4
D3
D2
D1
D0
1
0
1
1
0
0
0
1
21
www.national.com
LM95235/LM95235Q
3.0 Applications Hints
The LM95235 can be applied easily in the same way as other
integrated-circuit temperature sensors, and its remote diode
sensing capability allows it to be used in new ways as well. It
can be soldered to a printed circuit board, and because the
path of best thermal conductivity is between the die and the
pins, its temperature will effectively be that of the printed circuit board lands and traces soldered to the LM95235's pins.
This presumes that the ambient air temperature is almost the
same as the surface temperature of the printed circuit board;
if the air temperature is much higher or lower than the surface
temperature, the actual temperature of the LM95235 die will
be at an intermediate temperature between the surface and
air temperatures. Again, the primary thermal conduction path
is through the leads, so the circuit board temperature will contribute to the die temperature much more strongly than will the
air temperature.
To measure temperature external to the LM95235's die, use
a remote diode. This diode can be located on the die of a
target IC, allowing measurement of the IC's temperature, independent of the LM95235's temperature. A discrete diode
can also be used to sense the temperature of external objects
or ambient air. Remember that a discrete diode's temperature
will be affected, and often dominated, by the temperature of
its leads. Most silicon diodes do not lend themselves well to
this application. It is recommended that an MMBT3904 transistor base-emitter junction be used with the collector tied to
the base.
The LM95235's TruTherm technology allows accurate sensing of integrated thermal diodes, such as those found on most
processors. With TruTherm technology turned off, the
LM95235 can measure a diode-connected transistor such as
the MMBT3904 or the thermal diode found in an AMD processor.
The LM95235 has been optimized to measure the remote
thermal diode integrated in a typical Intel processor on
65 nm or 90 nm process or an MMBT3904 transistor. Using
the Remote Diode Model Select register either pair of remote
inputs can be assigned to be either a typical Intel processor
on 65 nm or 90 nm process or an MMBT3904.
•
•
•
•
q = 1.6×10−19 Coulombs (the electron charge),
T = Absolute Temperature in Kelvin
k = 1.38×10−23 joules/K (Boltzmann's constant),
η is the non-ideality factor of the process the diode is
manufactured on,
• IS = Saturation Current and is process dependent,
• If = Forward Current through the base-emitter junction
• VBE = Base-Emitter Voltage drop
In the active region, the -1 term is negligible and may be eliminated, yielding the following equation
(2)
In Equation 2, η and IS are dependant upon the process that
was used in the fabrication of the particular diode. By forcing
two currents with a very controlled ratio(IF2 / IF1) and measuring the resulting voltage difference, it is possible to eliminate
the IS term. Solving for the forward voltage difference yields
the relationship:
(3)
Solving Equation 3 for temperature yields:
(4)
3.1.1 Diode Non-Ideality Factor Effect on Accuracy
When a transistor is connected as a diode, the following relationship holds for variables VBE, T and IF:
Equation 4 holds true when a diode connected transistor such
as the MMBT3904 is used. When this “diode” equation is applied to an integrated diode such as a processor transistor
with its collector tied to GND as shown in Figure 7 it will yield
a wide non-ideality spread. This wide non-ideality spread is
not due to true process variation but due to the fact that
Equation 4 is an approximation.
TruTherm technology uses the transistor equation, Equation
5, which is a more accurate representation of the topology of
the thermal diode found in an FPGA or processor.
(1)
(5)
3.1 DIODE NON-IDEALITY
where:
www.national.com
22
LM95235/LM95235Q
20174943
FIGURE 7. Thermal Diode Current Paths
TruTherm should only be enabled when measuring the temperature of a transistor integrated as shown in the processor
of Figure 7, because Equation 5 only applies to this topology.
(6)
Solving Equation 6 for RPCB equal to ±1.73Ω results in the
additional error due to the spread in the series resistance of
±1.07°C. The spread in error cannot be canceled out, as it
would require measuring each individual thermal diode device. This is quite difficult and impractical in a large volume
production environment.
Equation 6 can also be used to calculate the additional error
caused by series resistance on the printed circuit board. Since
the variation of the PCB series resistance is minimal, the bulk
of the error term is always positive and can simply be cancelled out by subtracting it from the output readings of the
LM95235.
3.1.2 Calculating Total System Accuracy
The voltage seen by the LM95235 also includes the IFRS voltage drop of the series resistance. The non-ideality factor, η,
is the only other parameter not accounted for and depends
on the diode that is used for measurement. Since ΔVBE is
proportional to both η and T, the variations in η cannot be
distinguished from variations in temperature. Since the nonideality factor is not controlled by the temperature sensor, it
will directly add to the inaccuracy of the sensor. For the for
Intel processor on 65nm process, Intel specifies a +4.06%/
−0.897% variation in η from part to part when the processor
diode is measured by a circuit that assumes diode equation,
Equation 4, as true. As an example, assume a temperature
sensor has an accuracy specification of ±1.0°C at a temperature of 80°C (353 Kelvin) and the processor diode has a nonideality variation of +1.19%/−0.27%. The resulting system
accuracy of the processor temperature being sensed will be:
Processor Family
Intel Processor on
65 nm process
TACC = + 1.0°C + (+4.06% of 353 K) = +15.3 °C
and
Processor Family
TACC = - 1.0°C + (−0.89% of 353 K) = −4.1 °C
TrueTherm technology uses the transistor equation, Equation
5, resulting in a non-ideality spread that truly reflects the process variation which is very small. The transistor equation
non-ideality spread is ±0.39% for the Pentium 4 processor on
90 nm process. The resulting accuracy when using TruTherm
technology improves to:
TACC = ±0.75°C + (±0.39% of 353 K) = ± 2.16 °C
The next error term to be discussed is that due to the series
resistance of the thermal diode and printed circuit board
traces. The thermal diode series resistance is specified on
most processor data sheets. For Intel processors in 65 nm
process, this is specified at 4.52Ω typical. The LM95235 accommodates the typical series resistance of Intel Processor
on 65 nm process. The error that is not accounted for is the
spread of the processor's series resistance, that is 2.79Ω to
6.24Ω or ±1.73Ω. The equation to calculate the temperature
error due to series resistance (TER) for the LM95235 is simply:
23
Transistor Equation ηT,
non-ideality
min
typ
max
0.997
1.001
1.005
Diode Equation ηD, nonideality
Series
R,Ω
4.52
Series
R,Ω
min
typ
max
Pentium III CPUID
67h
1
1.0065
1.0125
Pentium III CPUID
68h/
PGA370Socket/
Celeron
1.0057
1.008
1.0125
Pentium 4, 423 pin
0.9933
1.0045
1.0368
Pentium 4, 478 pin
0.9933
1.0045
1.0368
Pentium 4 on 0.13
micron process, 2 3.06 GHz
1.0011
1.0021
1.0030
3.64
Pentium 4 on 90 nm
1.0083
process
1.011
1.023
3.33
Intel Processor on
65 nm process
1.009
1.050
4.52
1.000
www.national.com
LM95235/LM95235Q
Pentium M
(Centrino)
1.00151
MMBT3904
1.00220
1.00289
1.003
AMD Athlon MP
model 6
1.002
1.008
1.016
AMD Athlon 64
1.008
1.008
1.096
AMD Opteron
1.008
1.008
1.096
AMD Sempron
3.2 PCB LAYOUT FOR MINIMIZING NOISE
3.06
1.00261
0.93
3.1.3 Compensating for Different Non-Ideality
In order to compensate for the errors introduced by non-ideality, the temperature sensor is calibrated for a particular
processor. National Semiconductor temperature sensors are
always calibrated to the typical non-ideality and series resistance of a given processor type. The LM95235 is calibrated
for two non-ideality factors and series resistance values thus
supporting the MMBT3904 transistor and Intel processors on
65nm process without the requirement for additional trims.
For most accurate measurements TruTherm mode should be
turned on when measuring the Intel processor on 65nm process to minimize the error introduced by the false non-ideality
spread (see 3.1.1 Diode Non-Ideality Factor Effect on Accuracy). When a temperature sensor calibrated for a particular
processor type is used with a different processor type, additional errors are introduced.
Temperature errors associated with non-ideality of different
processor types may be reduced in a specific temperature
range of concern through use of software calibration. Typical
Non-ideality specification differences cause a gain variation
of the transfer function, therefore the center of the temperature range of interest should be the target temperature for
calibration purposes. The following equation can be used to
calculate the temperature correction factor (TCF) required to
compensate for a target non-ideality differing from that supported by the LM95235.
20174917
FIGURE 8. Ideal Diode Trace Layout
In a noisy environment, such as a processor mother board,
layout considerations are very critical. Noise induced on
traces running between the remote temperature diode sensor
and the LM95235 can cause temperature conversion errors.
Keep in mind that the signal level the LM95235 is trying to
measure is in microvolts. The following guidelines should be
followed:
1. VDD should be bypassed with a 0.1 µF capacitor in
parallel with 100 pF. The 100 pF capacitor should be
placed as close as possible to the power supply pin. A
bulk capacitance of approximately 10 µF needs to be in
the near vicinity of the LM95235.
2. A 100 pF diode bypass capacitor is recommended to filter
high frequency noise but may not be necessary. Make
sure the traces to the 100 pF capacitor are matched.
Place the filter capacitors close to the LM95235 pins.
3. Ideally, the LM95235 should be placed within 10 cm of
the Processor diode pins with the traces being as
straight, short and identical as possible. Trace resistance
of 1Ω can cause as much as 0.62°C of error. This error
can be compensated by using simple software offset
compensation.
4. Diode traces should be surrounded by a GND guard ring
to either side, above and below if possible. This GND
guard should not be between the D+ and D− lines. In the
event that noise does couple to the diode lines it would
be ideal if it is coupled common mode. That is equally to
the D+ and D− lines.
5. Avoid routing diode traces in close proximity to power
supply switching or filtering inductors.
6. Avoid running diode traces close to or parallel to high
speed digital and bus lines. Diode traces should be kept
at least 2 cm apart from the high speed digital traces.
7. If it is necessary to cross high speed digital traces, the
diode traces and the high speed digital traces should
cross at a 90 degree angle.
8. The ideal place to connect the LM95235's GND pin is as
close as possible to the Processors GND associated with
the sense diode.
9. Leakage current between D+ and GND and between D+
and D− should be kept to a minimum. Thirteen nanoamperes of leakage can cause as much as 0.2°C of error
in the diode temperature reading. Keeping the printed
circuit board as clean as possible will minimize leakage
current.
Noise coupling into the digital lines greater than 400 mVp-p
(typical hysteresis) and undershoot less than 500 mV below
GND, may prevent successful SMBus communication with
the LM95235. SMBus no acknowledge is the most common
symptom, causing unnecessary traffic on the bus. Although
(7)
where
• ηS = LM95235 non-ideality for accuracy specification
• ηPROCESSOR = Processor thermal diode typical non-ideality
• TCR = center of the temperature range of interest in °C
The correction factor should be directly added to the temperature reading produced by the LM95235. For example when
using the LM95235, with the 3904 mode selected, to measure
a AMD Athlon processor, with a typical non-ideality of 1.008,
for a temperature range of 60 °C to 100 °C the correction factor would calculate to:
(8)
Therefore, 1.75°C should be subtracted from the temperature
readings of the LM95235 to compensate for the differing typical non-ideality target.
www.national.com
24
added in series with the SMBDAT and SMBCLK lines to further help filter noise and ringing. Minimize noise coupling by
keeping digital traces out of switching power supply areas as
well as ensuring that digital lines containing high speed data
communications cross at right angles to the SMBDAT and
SMBCLK lines.
25
www.national.com
LM95235/LM95235Q
the SMBus maximum frequency of communication is rather
low (100 kHz max), care still needs to be taken to ensure
proper termination within a system with multiple parts on the
bus and long printed circuit board traces. An RC lowpass filter
with a 3 dB corner frequency of about 40 MHz is included on
the LM95235's SMBCLK input. Additional resistance can be
LM95235/LM95235Q
Physical Dimensions inches (millimeters) unless otherwise noted
8-Lead Molded Mini-Small-Outline Package (MSOP),
JEDEC Registration Number MO-187
Order Number LM95235CIMM, LM95235DIMM, LM95235EIMM, LM95235QEIMM, LM95235CIMMX, LM95235DIMMX,
LM95235EIMMX, and LM95235QEIMMX,
NS Package Number MUA08A
www.national.com
26
LM95235/LM95235Q
Notes
27
www.national.com
LM95235/LM95235Q Precision Remote Diode Temperature Sensor with SMBus Interface and
TruTherm Technology
Notes
For more National Semiconductor product information and proven design tools, visit the following Web sites at:
Products
Design Support
Amplifiers
www.national.com/amplifiers
WEBENCH
www.national.com/webench
Audio
www.national.com/audio
Analog University
www.national.com/AU
Clock Conditioners
www.national.com/timing
App Notes
www.national.com/appnotes
Data Converters
www.national.com/adc
Distributors
www.national.com/contacts
Displays
www.national.com/displays
Green Compliance
www.national.com/quality/green
Ethernet
www.national.com/ethernet
Packaging
www.national.com/packaging
Interface
www.national.com/interface
Quality and Reliability
www.national.com/quality
LVDS
www.national.com/lvds
Reference Designs
www.national.com/refdesigns
Power Management
www.national.com/power
Feedback
www.national.com/feedback
Switching Regulators
www.national.com/switchers
LDOs
www.national.com/ldo
LED Lighting
www.national.com/led
PowerWise
www.national.com/powerwise
Serial Digital Interface (SDI)
www.national.com/sdi
Temperature Sensors
www.national.com/tempsensors
Wireless (PLL/VCO)
www.national.com/wireless
THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION
(“NATIONAL”) PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY
OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO
SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS,
IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS
DOCUMENT.
TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT
NATIONAL’S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL
PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR
APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND
APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE
NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS.
EXCEPT AS PROVIDED IN NATIONAL’S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO
LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE
AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY
RIGHT.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR
SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL
COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein:
Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected
to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness.
National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other
brand or product names may be trademarks or registered trademarks of their respective holders.
Copyright© 2008 National Semiconductor Corporation
For the most current product information visit us at www.national.com
National Semiconductor
Americas Technical
Support Center
Email: [email protected]
Tel: 1-800-272-9959
www.national.com
National Semiconductor Europe
Technical Support Center
Email: [email protected]
German Tel: +49 (0) 180 5010 771
English Tel: +44 (0) 870 850 4288
National Semiconductor Asia
Pacific Technical Support Center
Email: [email protected]
National Semiconductor Japan
Technical Support Center
Email: [email protected]