LM89 ± 0.75˚C Accurate, Remote Diode and Local Digital Temperature Sensor with Two-Wire Interface General Description The LM89 is an 11-bit digital temperature sensor with a 2-wire System Management Bus (SMBus) serial interface. The LM89 accurately measures its own temperature as well as the temperature of an external device, such as processor thermal diode or diode-connected transistor such as the 2N3904. The temperature of any ASIC can be accurately determined using the LM89 as long as a dedicated diode (semiconductor junction) is available on the target die. The LM89 remote sensor accuracy of ± 0.75˚C is factory trimmed for the series resistance and 1.0021 typical non-ideality factor of the Intel ® Pentium™ 4 and the Mobile Pentium 4 Processor-M thermal diode. The LM89 has an Offset register to allow measuring other diodes without requiring continuous software management. Contact [email protected] to obtain the latest data for new processors. The LM89 and the LM89-1 have the same functions but different SMBus slave addresses. This allows for one of each to be on the bus at the same time. Activation of the ALERT output occurs when any temperature goes outside a preprogrammed window set by the HIGH and LOW temperature limit registers or exceeds the T_CRIT temperature limit. Activation of the T_CRIT_A occurs when any temperature exceeds the T_CRIT programmed limit. The LM89 is pin and register compatible with the LM86, LM90, Analog Devices ADM1032 and Maxim MAX6657/8. Features n Accurately senses die temperature of remote ICs or diode junctions n Offset register allows sensing a variety of thermal diodes accurately n On-board local temperature sensing n 10 bit plus sign remote diode temperature data format, 0.125 ˚C resolution n T_CRIT_A output useful for system shutdown n ALERT output supports SMBus 2.0 protocol n SMBus 2.0 compatible interface, supports TIMEOUT n 8-pin MSOP and SOIC packages Key Specifications j Supply Voltage 3.0 V to 3.6 V j Supply Current 0.8 mA (typ) j Local Temp Accuracy (includes quantization error) TA=25˚C to 125˚C ± 3.0 ˚C (max) j Remote Diode Temp Accuracy (includes quantization error) ± 0.75 ˚C (max) ± 1.0 ˚C (max) ± 3.0 ˚C (max) TA=0˚C to 85˚C, TD=25˚C to 125˚C TA=30˚C,TD=80˚C TA=30˚C to 50˚C, TD=60˚C to 100˚C Applications n Processor/Computer System Thermal Management (e.g. Laptop, Desktop, Workstations, Server) n Electronic Test Equipment n Office Electronics Simplified Block Diagram 20041501 Pentium™ is a trademark of Intel Corporation. © 2004 National Semiconductor Corporation DS200415 www.national.com LM89 ± 0.75˚C Accurate, Remote Diode and Local Digital Temperature Sensor with Two-Wire Interface December 2004 LM89 Connection Diagram MSOP-8 or SOIC-8 20041502 TOP VIEW Ordering Information Package Marking Part Number NS Package Number Transport Media LM89CIMM T15C MUA08A (MSOP-8) 1000 Units onTape and Reel LM89-1CIMM T19C MUA08A (MSOP-8) 1000 Units onTape and Reel LM89CIMMX T15C MUA08A (MSOP-8) 3500 Units on Tape and Reel LM89-1CIMMX T19C MUA08A (MSOP-8) 3500 Units on Tape and Reel LM89CIM M08A (SOIC-8) 95 Units in Rail LM89-1CIM LM89-1CIM M08A (SOIC-8) 95 Units in Rail LM89CIMX LM89CIM M08A (SOIC-8) 2500 Units on Tape and Reel LM89-1CIM M08A (SOIC-8) 2500 Units on Tape and Reel LM89CIM LM89-1CIMX Pin Descriptions Label Pin # VDD 1 Positive Supply Voltage Input DC Voltage from 3.0 V to 3.6 V. VDD should be bypassed with a 0.1µF capacitor in parallel with 100pF. The 100pF capacitor should be placed as close as possible to the power supply pin. A bulk capacitance of approximately 10µF needs to be in the near vicinity to the LM89 VDD. D+ 2 Diode Current Source To Diode Anode. Connected to remote discrete diode-connected transistor junction or to the diode-connected transistor junction on a remote IC whose die temperature is being sensed. A 2.2 nF diode bypass capacitor is required to filter high frequency noise. Place the 2.2 nF capacitor between and as close as possible to the LM89’s D+ and D− pins. Make sure the traces to the 2.2 nF capacitor are matched. D− 3 Diode Return Current Sink To Diode Cathode. T_CRIT_A 4 T_CRIT Alarm Output, Open-Drain, Active-Low Pull-Up Resistor, Controller Interrupt or Power Supply Shutdown Control Function Typical Connection GND 5 Power Supply Ground Ground ALERT 6 Interrupt Output, Open-Drain, Active-Low Pull-Up Resistor, Controller Interrupt or Alert Line SMBData 7 SMBus Bi-Directional Data Line, Open-Drain Output From and to Controller, Pull-Up Resistor SMBCLK 8 SMBus Input From Controller, Pull-Up Resistor www.national.com 2 LM89 Typical Application 20041503 3 www.national.com LM89 Absolute Maximum Ratings (Note 1) Supply Voltage Voltage at SMBData, SMBCLK, ALERT, T_CRIT_A Soldering Information, Lead Temperature SOIC-8 or MSOP-8 Packages (Note 3) −0.3 V to 6.0 V −0.5V to 6.0V Voltage at Other Pins −0.3 V to (VDD + 0.3 V) D− Input Current 215˚C Infrared (15 seconds) 220˚C ESD Susceptibility (Note 4) Human Body Model ± 1 mA 2000 V Machine Model Input Current at All Other Pins (Note 2) ± 5 mA Package Input Current (Note 2) 30 mA SMBData, ALERT, T_CRIT_A Output Sink Current 10 mA Storage Temperature Vapor Phase (60 seconds) 200 V Operating Ratings (Notes 1, 5) −65˚C to +150˚C Operating Temperature Range 0˚C to +125˚C Electrical Characteristics Temperature Range TMIN≤TA≤TMAX LM89 0˚C≤TA≤+85˚C Supply Voltage Range (VDD) +3.0V to +3.6V Temperature-to-Digital Converter Characteristics Unless otherwise noted, these specifications apply for VDD =+3.0Vdc to 3.6Vdc. Boldface limits apply for TA = TJ = TMIN≤TA≤TMAX; all other limits TA = TJ =+25˚C, unless otherwise noted. Parameter Conditions Typical Limits Units (Note 6) (Note 7) (Limit) ±1 ±3 ± 0.75 ˚C (max) Temperature Error Using Local Diode TA = +25˚C to +125˚C, (Note 8) Temperature Error Using Remote Diode of 0.13 micron Pentium 4 with typical non-ideality of 1.0021 and series R= 3.64Ω. For other processors email [email protected] to obtain the latest data. (TD is the Remote Diode Junction Temperature) TA = +30˚C TD = +80˚C TA = +30˚C to +50˚C TD = +60˚C to +100˚C ±1 ˚C (max) TA = +0˚C to +85˚C TD = +25˚C to +125˚C ±3 ˚C (max) Remote Diode Measurement Resolution 11 Local Diode Measurement Resolution Bits 0.125 ˚C 8 Bits 1 Conversion Time of All Temperatures at the Fastest Setting (Note 10) Quiescent Current (Note 9) ˚C 31.25 34.4 ms (max) SMBus Inactive, 16Hz conversion rate 0.8 1.7 mA (max) Shutdown 315 (D+ − D−)=+ 0.65V; high level 160 D− Source Voltage Diode Source Current ˚C (max) µA 0.7 Low level 13 V 315 µA (max) 110 µA (min) 20 µA (max) 7 µA (min) ALERT and T_CRIT_A Output Saturation Voltage IOUT = 6.0 mA 0.4 V (max) Power-On Reset Threshold Measure on VDD input, falling edge 2.4 1.8 V (max) V (min) Local and Remote HIGH Default Temperature settings (Note 11) +70 ˚C Local and Remote LOW Default Temperature settings (Note 11) 0 ˚C Local T_CRIT Default Temperature Setting (Note 11) +85 ˚C www.national.com 4 LM89 Temperature-to-Digital Converter Characteristics (Continued) Unless otherwise noted, these specifications apply for VDD =+3.0Vdc to 3.6Vdc. Boldface limits apply for TA = TJ = TMIN≤TA≤TMAX; all other limits TA = TJ =+25˚C, unless otherwise noted. Parameter Remote T_CRIT Default Temperature Setting Conditions (Note 11) Typical Limits Units (Note 6) (Note 7) (Limit) +110 ˚C Logic Electrical Characteristics DIGITAL DC CHARACTERISTICS Unless otherwise noted, these specifications apply for VDD =+3.0 to 3.6 Vdc. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ =+25˚C, unless otherwise noted. Symbol Parameter Conditions Typical Limits Units (Note 6) (Note 7) (Limit) SMBData, SMBCLK INPUTS VIN(1) Logical “1” Input Voltage 2.1 V (min) VIN(0) Logical “0”Input Voltage 0.8 V (max) VIN(HYST) SMBData and SMBCLK Digital Input Hysteresis 400 IIN(1) Logical “1” Input Current VIN = VDD 0.005 IIN(0) Logical “0” Input Current VIN = 0 V −0.005 CIN Input Capacitance mV ± 10 ± 10 µA (max) µA (max) 5 pF ALL DIGITAL OUTPUTS IOH High Level Output Current VOH = VDD 10 µA (max) 0.4 V (max) IOL = 4mA 0.6 IOL = 6mA SMBus DIGITAL SWITCHING CHARACTERISTICS Unless otherwise noted, these specifications apply for VDD =+3.0 Vdc to +3.6 Vdc, CL (load capacitance) on output lines = 80 pF. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = +25˚C, unless otherwise noted. The switching characteristics of the LM89 fully meet or exceed the published specifications of the SMBus version 2.0. The following parameters are the timing relationships between SMBCLK and SMBData signals related to the LM89. They adhere to but are not necessarily the SMBus bus specifications. VOL Symbol SMBus Low Level Output Voltage Parameter Conditions Typical Limits (Note 6) (Note 7) (Limit) 100 10 kHz (max) kHz (min) 4.7 25 µs (min) ms (max) fSMB SMBus Clock Frequency tLOW SMBus Clock Low Time from VIN(0)max to VIN(0)max tHIGH SMBus Clock High Time from VIN(1)min to VIN(1)min tR,SMB SMBus Rise Time (Note 12) 1 tF,SMB SMBus Fall Time (Note 13) 0.3 tOF Output Fall Time CL = 400pF, IO = 3mA, (Note 13) tTIMEOUT 4.0 Units µs (min) µs (max) µs (max) 250 ns (max) SMBData and SMBCLK Time Low for Reset of Serial Interface (Note 14) 25 35 ms (min) ms (max) tSU;DAT Data In Setup Time to SMBCLK High 250 ns (min) tHD;DAT Data Out Stable after SMBCLK Low 300 900 ns (min) ns (max) tHD;STA Start Condition SMBData Low to SMBCLK Low (Start condition hold before the first clock falling edge) 100 ns (min) tSU;STO Stop Condition SMBCLK High to SMBData Low (Stop Condition Setup) 100 ns (min) tSU;STA SMBus Repeated Start-Condition Setup Time, SMBCLK High to SMBData Low 0.6 µs (min) tBUF SMBus Free Time Between Stop and Start Conditions 1.3 µs (min) 5 www.national.com LM89 SMBus Communication 20041540 Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not apply when operating the device beyond its rated operating conditions. Note 2: When the input voltage (VI) at any pin exceeds the power supplies (VI < GND or VI > VDD), the current at that pin should be limited to 5 mA. Parasitic components and or ESD protection circuitry are shown in the figure below for the LM89’s pins. The nominal breakdown voltage of D3 is 6.5 V. Care should be taken not to forward bias the parasitic diode, D1, present on pins: D+, D−. Doing so by more than 50 mV may corrupt a temperature measurements. Pin Name PIN # D1 D2 D3 D4 D5 D6 D7 R1 SNP VDD 1 D+ 2 x x D− 3 x x T_CRIT_A 4 x x x ALERT 6 x x x SMBData 7 x x x SMBCLK 8 ESD CLAMP x x x x x x x x x x Note: An “x” indicates that the diode exists. 20041513 FIGURE 1. ESD Protection Input Structure Note 3: See the URL ”http://www.national.com/packaging/“ for other recommendations and methods of soldering surface mount devices. Note 4: Human body model, 100pF discharged through a 1.5kΩ resistor. Machine model, 200pF discharged directly into each pin. Note 5: Thermal resistance junction-to-ambient when attached to a printed circuit board with 2 oz. foil: – SOIC-8 = 168˚C/W – MSOP-8 = 210˚C/W Note 6: Typicals are at TA = 25˚C and represent most likely parametric norm. Note 7: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level). Note 8: Local temperature accuracy does not include the effects of self-heating. The rise in temperature due to self-heating is the product of the internal power dissipation of the LM89 and the thermal resistance. See (Note 5) for the thermal resistance to be used in the self-heating calculation. Note 9: Quiescent current will not increase substantially with an SMBus. Note 10: This specification is provided only to indicate how often temperature data is updated. The LM89 can be read at any time without regard to conversion state (and will yield last conversion result). Note 11: Default values set at power up. Note 12: The output rise time is measured from (VIN(0)max + 0.15V) to (VIN(1)min − 0.15V). Note 13: The output fall time is measured from (VIN(1)min - 0.15V) to (VIN(1)min + 0.15V). Note 14: Holding the SMBData and/or SMBCLK lines Low for a time interval greater than tTIMEOUT will reset the LM89’s SMBus state machine, therefore setting SMBData and SMBCLK pins to a high impedance state. www.national.com 6 LM89 1.0 Functional Description The LM89 temperature sensor incorporates a delta VBE based temperature sensor using a Local or Remote diode and a 10-bit plus sign ADC (Delta-Sigma Analog-to-Digital Converter). The LM89 is compatible with the serial SMBus version 2.0 two-wire interface. Digital comparators compare the measured Local Temperature (LT) to the Local High (LHS), Local Low (LLS) and Local T_CRIT (LCS) userprogrammable temperature limit registers. The measured Remote Temperature (RT) is digitally compared to the Remote High (RHS), Remote Low (RLS) and Remote T_CRIT (RCS) user-programmable temperature limit registers. Activation of the ALERT output indicates that a comparison is greater than the limit preset in a T_CRIT or HIGH limit register or less than the limit preset in a LOW limit register. The T_CRIT_A output responds as a true comparator with built in hysteresis. The hysteresis is set by the value placed in the Hysteresis register (TH). Activation of T_CRIT_A occurs when the temperature is above the T_CRIT setpoint. T_CRIT_A remains activated until the temperature goes below the setpoint calculated by T_CRIT − TH. The hysteresis register impacts both the remote temperature and local temperature readings. The LM89 may be placed in a low power consumption (Shutdown) mode by setting the RUN/STOP bit found in the Configuration register. In the Shutdown mode, the LM89’s SMBus interface remains while all circuitry not required is turned off. The Local temperature reading and setpoint data registers are 8-bits wide. The format of the 11-bit remote temperature data is a 16-bit left justified word. Two 8-bit registers, high and low bytes, are provided for each setpoint as well as the temperature reading. Two offset registers (RTOLB and RTOHB) can be used to compensate for non_ideality error, discussed further in Section 4.1 DIODE NON-IDEALITY. The remote temperature reading reported is adjusted by subtracting from or adding to the actual temperature reading the value placed in the offset registers. 20041539 FIGURE 2. Conversion Rate Effect on Power Supply Current 1.2 THE ALERT OUTPUT The LM89’s ALERT pin is an active-low open-drain output that is triggered by a temperature conversion that is outside the limits defined by the temperature setpoint registers. Reset of the ALERT output is dependent upon the selected method of use. The LM89’s ALERT pin is versatile and will accommodate three different methods of use to best serve the system designer: as a temperature comparator, as a temperature based interrupt flag, and as part of an SMBus ALERT system. The three methods of use are further described below. The ALERT and interrupt methods are different only in how the user interacts with the LM89. Each temperature reading (LT and RT) is associated with a T_CRIT setpoint register (LCS, RCS), a HIGH setpoint register (LHS and RHS) and a LOW setpoint register (LLS and RLS). At the end of every temperature reading, a digital comparison determines whether that reading is above its HIGH or T_CRIT setpoint or below its LOW setpoint. If so, the corresponding bit in the STATUS REGISTER is set. If the ALERT mask bit is not high, any bit set in the STATUS REGISTER, with the exception of Busy (D7) and OPEN (D2), will cause the ALERT output to be pulled low. Any temperature conversion that is out of the limits defined by the temperature setpoint registers will trigger an ALERT. Additionally, the ALERT mask bit in the Configuration register must be cleared to trigger an ALERT in all modes. 1.1 CONVERSION SEQUENCE The LM89 takes approximately 31.25 ms to convert the Local Temperature (LT), Remote Temperature (RT), and to update all of its registers. Only during the conversion process the busy bit (D7) in the Status register (02h) is high. These conversions are addressed in a round robin sequence. The conversion rate may be modified by the Conversion Rate Register (04h). When the conversion rate is modified a delay is inserted between conversions, the actual conversion time remains at 31.25ms. Different conversion rates will cause the LM89 to draw different amounts of supply current as shown in Figure 2. 1.2.1 ALERT Output as a Temperature Comparator When the LM89 is implemented in a system in which it is not serviced by an interrupt routine, the ALERT output could be used as a temperature comparator. Under this method of use, once the condition that triggered the ALERT to go low is no longer present, the ALERT is de-asserted (Figure 3). For example, if the ALERT output was activated by the comparison of LT > LHS, when this condition is no longer true the ALERT will return HIGH. This mode allows operation without software intervention, once all registers are configured during set-up. In order for the ALERT to be used as a temperature comparator, bit D0 (the ALERT configure bit) in the FILTER and ALERT CONFIGURE REGISTER (xBF) must be set high. This is not the power-on-default state. 7 www.national.com LM89 1.0 Functional Description (Continued) 20041528 20041531 FIGURE 4. ALERT Output as an Interrupt Temperature Response Diagram FIGURE 3. ALERT Comparator Temperature Response Diagram 1.2.3 ALERT Output as an SMBus ALERT When the ALERT output is connected to one or more ALERT outputs of other SMBus compatible devices and to a master, an SMBus alert line is created. Under this implementation, the LM89’s ALERT should be operated using the ARA (Alert Response Address) protocol. The SMBus 2.0 ARA protocol, defined in the SMBus specification 2.0, is a procedure designed to assist the master in resolving which part generated an interrupt and service that interrupt while impeding system operation as little as possible. The SMBus alert line is connected to the open-drain ports of all devices on the bus thereby AND’ing them together. The ARA is a method by which with one command the SMBus master may identify which part is pulling the SMBus alert line LOW and prevent it from pulling it LOW again for the same triggering condition. When an ARA command is received by all devices on the bus, the devices pulling the SMBus alert line LOW, first, send their address to the master and second, release the SMBus alert line after recognizing a successful transmission of their address. The SMBus 1.1 and 2.0 specification state that in response to an ARA (Alert Response Address) “after acknowledging the slave address the device must disengage its SMBALERT pulldown”. Furthermore, “if the host still sees SMBALERT low when the message transfer is complete, it knows to read the ARA again”. This SMBus “disengaging of SMBALERT” requirement prevents locking up the SMBus alert line. Competitive parts may address this “disengaging of SMBALERT” requirement differently than the LM89 or not at all. SMBus systems that implement the ARA protocol as suggested for the LM89 will be fully compatible with all competitive parts. The LM89 fulfills “disengaging of SMBALERT” by setting the ALERT mask bit (bit D7 in the Configuration register, at address 09h) after successfully sending out its address in response to an ARA and releasing the ALERT output pin. Once the ALERT mask bit is activated, the ALERT output pin will be disabled until enabled by software. In order to enable the ALERT the master must read the STATUS REGISTER, at address 02h, during the interrupt service routine and then reset the ALERT mask bit in the Configuration register to 0 at the end of the interrupt service routine. The following sequence describes the ARA response protocol. 1.2.2 ALERT Output as an Interrupt The LM89’s ALERT output can be implemented as a simple interrupt signal when it is used to trigger an interrupt service routine. In such systems it is undesirable for the interrupt flag to repeatedly trigger during or before the interrupt service routine has been completed. Under this method of operation, during a read of the STATUS REGISTER the LM89 will set the ALERT mask bit (D7 of the Configuration register) if any bit in the STATUS REGISTER is set, with the exception of Busy (D7) and OPEN (D2). This prevents further ALERT triggering until the master has reset the ALERT mask bit, at the end of the interrupt service routine. The STATUS REGISTER bits are cleared only upon a read command from the master (see Figure 4) and will be re-asserted at the end of the next conversion if the triggering condition(s) persist(s). In order for the ALERT to be used as a dedicated interrupt signal, bit D0 (the ALERT configure bit) in the FILTER and ALERT CONFIGURE REGISTER (xBF) must be set low. This is the power-on-default state. The following sequence describes the response of a system that uses the ALERT output pin as a interrupt flag: 1. Master Senses ALERT low 2. Master reads the LM89 STATUS REGISTER to determine what caused the ALERT 3. LM89 clears STATUS REGISTER, resets the ALERT HIGH and sets the ALERT mask bit (D7 in the Configuration register). 4. Master attends to conditions that caused the ALERT to be triggered. The fan is started, setpoint limits are adjusted, etc. 5. Master resets the ALERT mask (D7 in the Configuration register). www.national.com 8 1. reset only after the Status Register is read and if a temperature conversion(s) is/are below the T_CRIT setpoint, as shown in Figure 6. (Continued) Master Senses SMBus alert line low 2. Master sends a START followed by the Alert Response Address (ARA) with a Read Command. 3. Alerting Device(s) send ACK. 4. Alerting Device(s) send their Address. While transmitting their address, alerting devices sense whether their address has been transmitted correctly. (The LM89 will reset its ALERT output and set the ALERT mask bit once its complete address has been transmitted successfully.) 5. 6. Master/slave NoACK Master sends STOP 7. Master attends to conditions that caused the ALERT to be triggered. The STATUS REGISTER is read and fan started, setpoint limits adjusted, etc. 8. Master resets the ALERT mask (D7 in the Configuration register). 20041506 FIGURE 6. T_CRIT_A Temperature Response Diagram The ARA, 000 1100, is a general call address. No device should ever be assigned this address. Bit D0 (the ALERT configure bit) in the FILTER and ALERT CONFIGURE REGISTER (xBF) must be set low in order for the LM89 to respond to the ARA command. 1.4 POWER-ON-DEFAULT STATES LM89 always powers up to these known default states. The LM89 remains in these states until after the first conversion. The ALERT output can be disabled by setting the ALERT mask bit, D7, of the Configuration register. The power-ondefault is to have the ALERT mask bit and the ALERT configure bit low. 1. 2. Command Register set to 00h Local Temperature set to 0˚C 3. Remote Diode Temperature set to 0˚C until the end of the first conversion. 4. 5. Status Register set to 00h. Configuration register set to 00h; ALERT enabled, Remote T_CRIT alarm enabled and Local T_CRIT alarm enabled 6. 85˚C Local T_CRIT temperature setpoint 7. 8. 9. 10. 110˚C Remote T_CRIT temperature setpoint 70˚C Local and Remote HIGH temperature setpoints 0˚C Local and Remote LOW temperature setpoints Filter and Alert Configure Register set to 00h; filter disabled, ALERT output set as an SMBus ALERT 11. Conversion Rate Register set to 8h; conversion rate set to 16 conv./sec. 1.5 SMBus INTERFACE The LM89 operates as a slave on the SMBus, so the SMBCLK line is an input and the SMBData line is bidirectional. The LM89 never drives the SMBCLK line and it does not support clock stretching. According to SMBus specifications, the LM89 has a 7-bit slave address. All bits A6 through A0 are internally programmed and can not be changed by software or hardware. The LM89 and LM89-1 versions have the following SMBus slave addresses: 20041529 FIGURE 5. ALERT Output as an SMBus ALERT Temperature Response Diagram 1.3 T_CRIT_A OUTPUT and T_CRIT LIMIT T_CRIT_A is activated when any temperature reading is greater than the limit preset in the critical temperature setpoint register (T_CRIT), as shown in Figure 6. The Status Register can be read to determine which event caused the alarm. A bit in the Status Register is set high to indicate which temperature reading exceeded the T_CRIT setpoint temperature and caused the alarm, see Section 2.3. Local and remote temperature diodes are sampled in sequence by the A/D converter. The T_CRIT_A output and the Status Register flags are updated after every Local and Remote temperature conversion. T_CRT_A follows the state of the comparison, it is reset when the temperature falls below the setpoint RCS-TH. The Status Register flags are Version A6 A5 A4 A3 A2 A1 A0 LM89 1 0 0 1 1 0 0 LM89-1 1 0 0 1 1 0 1 1.6 TEMPERATURE DATA FORMAT Temperature data can only be read from the Local and Remote Temperature registers; the setpoint registers (T_CRIT, LOW, HIGH) are read/write. Remote temperature data is represented by an 11-bit, two’s complement word with an LSB (Least Significant Bit) equal to 0.125˚C. The data format is a left justified 16-bit word 9 www.national.com LM89 1.0 Functional Description LM89 1.0 Functional Description Setpoint High Byte Register (RHSHB) is set to a value less than +127˚C then ALERT will be pulled low, if the Alert Mask is disabled. The OPEN bit itself will not trigger and ALERT. (Continued) available in two 8-bit registers: Temperature In the event that the D+ pin is shorted to ground or D−, the Remote Temperature High Byte (RTHB) register is loaded with −128˚C (1000 0000) and the OPEN bit (D2) in the status register will not be set. Since operating the LM89 at −128˚C is beyond it’s operational limits, this temperature reading represents this shorted fault condition. If the value in the Remote Low Setpoint High Byte Register (RLSHB) is more than −128˚C and the Alert Mask is disabled, ALERT will be pulled low. Digital Output Binary Hex +125˚C 0111 1101 0000 0000 7D00h +25˚C 0001 1001 0000 0000 1900h +1˚C 0000 0001 0000 0000 0100h +0.125˚C 0000 0000 0010 0000 0020h 0˚C 0000 0000 0000 0000 0000h −0.125˚C 1111 1111 1110 0000 FFE0h −1˚C 1111 1111 0000 0000 FF00h −25˚C 1110 0111 0000 0000 E700h −55˚C 1100 1001 0000 0000 C900h Remote diode temperature sensors that have been previously released and are competitive with the LM89 output a code of 0˚C if the external diode is short-circuited. This change is an improvement that allows a reading of 0˚C to be truly interpreted as a genuine 0˚C reading and not a fault condition. Local Temperature data is represented by an 8-bit, two’s complement byte with an LSB (Least Significant Bit) equal to 1˚C: Temperature 1.9 COMMUNICATING WITH THE LM89 The data registers in the LM89 are selected by the Command Register. At power-up the Command Register is set to “00”, the location for the Read Local Temperature Register. The Command Register latches the last location it was set to. Each data register in the LM89 falls into one of four types of user accessibility: 1. Read only Digital Output Binary Hex +125˚C 0111 1101 7Dh +25˚C 0001 1001 19h +1˚C 0000 0001 01h 0˚C 0000 0000 00h −1˚C 1111 1111 FFh −25˚C 1110 0111 E7h −55˚C 1100 1001 C9h 2. Write only 3. Read/Write same address 4. Read/Write different address A Write to the LM89 will always include the address byte and the command byte. A write to any register requires one data byte. 1.7 OPEN-DRAIN OUTPUTS The SMBData, ALERT and T_CRIT_A outputs are opendrain outputs and do not have internal pull-ups. A “high” level will not be observed on these pins until pull-up current is provided by some external source, typically a pull-up resistor. Choice of resistor value depends on many system factors but, in general, the pull-up resistor should be as large as possible. This will minimize any internal temperature reading errors due to internal heating of the LM89. The maximum resistance of the pull-up to provide a 2.1V high level, based on LM89 specification for High Level Output Current with the supply voltage at 3.0V, is 82kΩ(5%) or 88.7kΩ(1%). Reading the LM89 can take place either of two ways: 1. If the location latched in the Command Register is correct (most of the time it is expected that the Command Register will point to one of the Read Temperature Registers because that will be the data most frequently read from the LM89), then the read can simply consist of an address byte, followed by retrieving the data byte. 2. If the Command Register needs to be set, then an address byte, command byte, repeat start, and another address byte will accomplish a read. The data byte has the most significant bit first. At the end of a read, the LM89 can accept either acknowledge or No Acknowledge from the Master (No Acknowledge is typically used as a signal for the slave that the Master has read its last byte). It takes the LM89 31.25ms to measure the temperature of the remote diode and internal diode. When retrieving all 10 bits from a previous remote diode temperature measurement, the master must insure that all 10 bits are from the same temperature conversion. This may be achieved by using one-shot mode or by setting the conversion rate and monitoring the busy bit such that no conversion occurs in between reading the MSB and LSB of the last temperature conversion. 1.8 DIODE FAULT DETECTION The LM89 is equipped with operational circuitry designed to detect fault conditions concerning the remote diode. In the event that the D+ pin is detected as shorted to VDD or floating, the Remote Temperature High Byte (RTHB) register is loaded with +127˚C, the Remote Temperature Low Byte (RTLB) register is loaded with 0, and the OPEN bit (D2) in the status register is set. As a result, if the Remote T_CRIT setpoint register (RCS) is set to a value less than +127˚C the ALERT and T_Crit output pins will be pulled low, if the Alert Mask and T_Crit Mask are disabled. If the Remote HIGH www.national.com 10 LM89 1.0 Functional Description 1.9.1 SMBus Timing Diagrams (Continued) LM89 Timing Diagram 20041510 (a) Serial Bus Write to the internal Command Register followed by a the Data Byte 20041511 (b) Serial Bus Write to the Internal Command Register 20041512 (c) Serial Bus Read from a Register with the Internal Command Register preset to desired value. FIGURE 7. SMBus Timing Diagrams a timeout of all devices on the bus the SMBCLK or SMBData lines must be held low for at least 35ms. 2. When SMBData is HIGH, have the master initiate an SMBus start. The LM89 will respond properly to an SMBus start condition at any point during the communication. After the start the LM89 will expect an SMBus Address address byte. 1.10 SERIAL INTERFACE RESET In the event that the SMBus Master is RESET while the LM89 is transmitting on the SMBData line, the LM89 must be returned to a known state in the communication protocol. This may be done in one of two ways: 1. When SMBData is LOW, the LM89 SMBus state machine resets to the SMBus idle state if either SMBData or SMBCLK are held low for more than 35ms (tTIMEOUT). Note that according to SMBus specification 2.0 all devices are to timeout when either the SMBCLK or SMBData lines are held low for 25-35ms. Therefore, to insure 1.11 DIGITAL FILTER In order to suppress erroneous remote temperature readings due to noise, the LM89 incorporates a user-configured digital filter. The filter is accessed in the FILTER and ALERT CON11 www.national.com LM89 1.0 Functional Description Level 2 sets maximum filtering. Figure 8 depicts the filter output in response to a step input and an impulse input. Figure 9 depicts the digital filter in use in a Pentium 4 processor system. Note that the two curves, with filter and without, have been purposely offset so that both responses can be clearly seen. Inserting the filter does not induce an offset as shown. (Continued) FIGURE REGISTER at BFh. The filter can be set according to the following table. D2 D1 0 0 No Filter Filter 0 1 Level 1 1 0 Level 1 1 1 Level 2 20041525 20041526 a) Step Response b) Impulse Response FIGURE 8. Filter Output Response to a Step Input 20041527 FIGURE 9. Digital Filter Response in a Pentium 4 processor System. The filter on and off curves were purposely offset to better show noise performance. www.national.com 12 (Continued) 1.13 ONE-SHOT REGISTER The One-Shot register is used to initiate a single conversion and comparison cycle when the device is in standby mode, after which the device returns to standby. This is not a data register and it is the write operation that causes the one-shot conversion. The data written to this address is irrelevant and is not stored. A zero will always be read from this register. 1.12 FAULT QUEUE In order to suppress erroneous ALERT or T_CRIT triggering the LM89 incorporates a Fault Queue. The Fault Queue acts to insure a remote temperature measurement is genuinely beyond a HIGH, LOW or T_CRIT setpoint by not triggering until three consecutive out of limit measurements have been made, see Figure 10. The fault queue defaults off upon power-up and may be activated by setting bit D0 in the Configuration register (09h) to “1”. 20041530 FIGURE 10. Fault Queue Temperature Response Diagram 2.0 LM89 Registers 2.1 COMMAND REGISTER Selects which registers will be read from or written to. Data for this register should be transmitted during the Command Byte of the SMBus write communication. P7 P6 P5 P4 P3 P2 P1 P0 Command Select P0-P7: Command Select Command Select Address Power-On-Default State < D7:D0 > Register Name Read Address < P7:P0 > hex Write Address < P7:P0 > hex < D7:D0 > binary 00h NA 0000 0000 0 LT 01h NA 0000 0000 0 RTHB 02h NA 0000 0000 0 SR 03h 09h 0000 0000 0 C 04h 0Ah 0000 1000 8 (16 conv./sec) CR Register Function decimal Local Temperature Remote Temperature High Byte Status Register Configuration Conversion Rate 05h 0Bh 0100 0110 70 LHS Local HIGH Setpoint 06h 0Ch 0000 0000 0 LLS Local LOW Setpoint 07h 0Dh 0100 0110 70 RHSHB Remote HIGH Setpoint High Byte 08h 0Eh 0000 0000 0 RLSHB Remote LOW Setpoint High Byte NA 0Fh One Shot 10h NA 0000 0000 0 RTLB 11h 11h 0000 0000 0 RTOHB 13 Writing to this register will initiate a one shot conversion Remote Temperature Low Byte Remote Temperature Offset High Byte www.national.com LM89 1.0 Functional Description LM89 2.0 LM89 Registers (Continued) Command Select Address Power-On-Default State < D7:D0 > Register Name Register Function Read Address < P7:P0 > hex Write Address < P7:P0 > hex < D7:D0 > binary 12h 12h 0000 0000 0 RTOLB Remote Temperature Offset Low Byte 13h 13h 0000 0000 0 RHSLB Remote HIGH Setpoint Low Byte 14h 14h 0000 0000 0 RLSLB 19h 19h 0110 1110 110 RCS Remote T_CRIT Setpoint 20h 20h 0101 0101 85 LCS Local T_CRIT Setpoint 0000 1010 10 TH decimal Remote LOW Setpoint Low Byte 21h 21h B0h-BEh B0h-BEh T_CRIT Hysteresis BFh BFh 0000 0000 0 RDTF Remote Diode Temperature Filter FEh NA 0000 0001 1 RMID Read Manufacturer’s ID FFh NA 49 52 RDR Read Stepping or Die Revision Code Manufacturers Test Registers LM89 0011 0001 LM89-1 0011 0100 2.2 LOCAL and REMOTE TEMPERATURE REGISTERS (LT, RTHB, RTLB) (Read Only Address 00h, 01h): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value SIGN 64 32 16 8 4 2 1 For LT and RTHB D7–D0: Temperature Data. LSB = 1˚C. Two’s complement format. (Read Only Address 10h): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value 0.5 0.25 0.125 0 0 0 0 0 For RTLB D7–D5: Temperature Data. LSB = 0.125˚C. Two’s complement format. The maximum value available from the Local Temperature register is 127; the minimum value available from the Local Temperature register is -128. The maximum value available from the Remote Temperature register is 127.875; the minimum value available from the Remote Temperature registers is −128.875. 2.3 STATUS REGISTER (SR) (Read Only Address 02h): D7 D6 D5 D4 D3 D2 D1 D0 Busy LHIGH LLOW RHIGH RLOW OPEN RCRIT LCRIT Power up default is with all bits “0” (zero). D0: LCRIT: When set to “1” indicates a Local Critical Temperature alarm. D1: RCRIT: When set to “1” indicates a Remote Diode Critical Temperature alarm. D2: OPEN: When set to “1” indicates a Remote Diode disconnect. D3: RLOW: When set to “1” indicates a Remote Diode LOW Temperature alarm D4: RHIGH: When set to “1” indicates a Remote Diode HIGH Temperature alarm. D5: LLOW: When set to “1” indicates a Local LOW Temperature alarm. D6: LHIGH: When set to “1” indicates a Local HIGH Temperature alarm. D7: Busy: When set to “1” ADC is busy converting. 2.4 CONFIGURATION REGISTER (Read Address 03h /Write Address 09h): D7 D6 D5 D4 D3 D2 D1 D0 ALERT mask RUN/STOP 0 Remote T_CRIT_A mask 0 Local T_CRIT_A mask 0 Fault Queue Power up default is with all bits “0” (zero) D7: ALERT mask: When set to “1” ALERT interrupts are masked. www.national.com 14 LM89 2.0 LM89 Registers (Continued) D6: RUN/STOP: When set to “1” SHUTDOWN is enabled. D5: is not defined and defaults to “0”. D4: Remote T_CRIT mask: When set to “1” a diode temperature reading that exceeds T_CRIT setpoint will not activate the T_CRIT_A pin. D3: is not defined and defaults to “0”. D2: Local T_CRIT mask: When set to “1” a Local temperature reading that exceeds T_CRIT setpoint will not activate the T_CRIT_A pin. D1: is not defined and defaults to “0”. D0: Fault Queue: when set to “1” three consecutive remote temperature measurements outside the HIGH, LOW, or T_CRIT setpoints will trigger an “Outside Limit” condition resulting in setting of status bits and associated output pins.. 2.5 CONVERSION RATE REGISTER (Read Address 04h /Write Address 0Ah) (Read Address 04h /Write Address 0Ah) Value Conversion Rate Value Conversion Rate 00 62.5 mHz 06 4 Hz 01 125 mHz 07 8 Hz 02 250 mHz 08 16 Hz 03 500 mHz 09 32 Hz 04 1 Hz 10-255 Undefined 05 2 Hz 2.6 LOCAL and REMOTE HIGH SETPOINT REGISTERS (LHS, RHSHB, and RHSLB) (Read Address 05h, 07h /Write Address 0Bh, 0Dh): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value SIGN 64 32 16 8 4 2 1 For LHS and RHSHB: HIGH setpoint temperature data. Power up default is LHIGH = RHIGH = 70˚C. 1 LSB = 1˚C. Two’s complement format. (Read/Write Address 13h): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value 0.5 0.25 0.125 0 0 0 0 0 For RHSLB: Remote HIGH Setpoint Low Byte temperature data. Power up default is 0˚C. 1 LSB = 0.125˚C. Two’s complement format. 2.7 LOCAL and REMOTE LOW SETPOINT REGISTERS (LLS, RLSHB, and RLSLB) (Read Address 06h, 08h, /Write Address 0Ch, 0Eh): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value SIGN 64 32 16 8 4 2 1 For LLS and RLSHB: HIGH setpoint temperature data. Power up default is LHIGH = RHIGH = 0˚C. 1 LSB = 1˚C. Two’s complement format. (Read/Write Address 14h): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value 0.5 0.25 0.125 0 0 0 0 0 For RLSLB: Remote HIGH Setpoint Low Byte temperature data. Power up default is 0˚C. 1 LSB = 0.125˚C. Two’s complement format. 2.8 REMOTE TEMPERATURE OFFSET REGISTERS (RTOHB and RTOLB) (Read/Write Address 11h): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value SIGN 64 32 16 8 4 2 1 15 www.national.com LM89 2.0 LM89 Registers (Continued) For RTOHB: Remote Temperature Offset High Byte. Power up default is LHIGH = RHIGH = 0˚C. 1 LSB = 1˚C. Two’s complement format. (Read/Write Address 12h): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value 0.5 0.25 0.125 0 0 0 0 0 For RTOLB: Remote Temperature Offset High Byte. Power up default is 0˚C. 1 LSB = 0.125˚C. Two’s complement format. The offset value written to these registers will automatically be added to or subtracted from the remote temperature measurement that will be reported in the Remote Temperature registers. 2.9 LOCAL and REMOTE T_CRIT REGISTERS (RCS and LCS) (Read/Write Address 20h, 19h): BIT D7 D6 D5 D4 D3 D2 D1 D0 Value SIGN 64 32 16 8 4 2 1 D7–D0: T_CRIT setpoint temperature data. Power up default is Local T_CRIT = 85˚C and Remote T_CRIT=110˚C. 1 LSB = 1˚C, two’s complement format. 2.10 T_CRIT HYSTERESIS REGISTER (TH) (Read and Write Address 21h): BIT D7 D6 D5 Value D4 D3 D2 D1 D0 16 8 4 2 1 D7–D0: T_CRIT Hysteresis temperature. Power up default is TH = 10˚C. 1 LSB = 1˚C, maximum value = 31. 2.11 FILTER and ALERT CONFIGURE REGISTER (Read and Write Address BFh): BIT D7 D6 D5 D4 D3 Value 0 0 0 0 0 D2 D1 Filter Level D0 ALERT Configure D7-D3: is not defined defaults to "0". D2-D1: input filter setting as defined the table below: D2 D1 Filter Level 0 0 No Filter 0 1 Level 1 1 0 Level 1 1 1 Level 2 Level 2 sets maximum filtering. D0: when set to "1" comparator mode is enabled. 2.12 MANUFACTURERS ID REGISTER (Read Address FEh) The default value is 01h. 2.13 DIE REVISION CODE REGISTER (Read Address FFh) The LM89 version has a default value of 31h or 49 decimal. The LM89-1 version has a default value of 34h or 52 decimal. This register will increment by 1 every time there is a revision to the die by National Semiconductor. if the air temperature is much higher or lower than the surface temperature, the actual temperature of the LM89 die will be at an intermediate temperature between the surface and air temperatures. Again, the primary thermal conduction path is through the leads, so the circuit board temperature will contribute to the die temperature much more strongly than will the air temperature. To measure temperature external to the LM89’s die, use a remote diode. This diode can be located on the die of a target IC, allowing measurement of the IC’s temperature, independent of the LM89’s temperature. The LM89 has been 3.0 Applications Hints The LM89 can be applied easily in the same way as other integrated-circuit temperature sensors, and its remote diode sensing capability allows it to be used in new ways as well. It can be soldered to a printed circuit board, and because the path of best thermal conductivity is between the die and the pins, its temperature will effectively be that of the printed circuit board lands and traces soldered to the LM89’s pins. This presumes that the ambient air temperature is almost the same as the surface temperature of the printed circuit board; www.national.com 16 the diode that is used for measurement. Since ∆VBE is proportional to both η and T, the variations in η cannot be distinguished from variations in temperature. Since the nonideality factor is not controlled by the temperature sensor, it will directly add to the inaccuracy of the sensor. For the Pentium 4 and Mobile Pentium Processor-M Intel specifies a ± 0.1% variation in η from part to part. As an example, assume a temperature sensor has an accuracy specification of ± 1˚C at room temperature of 25 ˚C and the process used to manufacture the diode has a non-ideality variation of ± 0.1%. The resulting accuracy of the temperature sensor at room temperature will be: TACC = ± 1˚C + ( ± 0.1% of 298 ˚K) = ± 1.4 ˚C (Continued) optimized to measure the remote thermal diode of a 0.13 micron Pentium 4 or a Mobile Pentium 4 Processor-M processor. A discrete diode can also be used to sense the temperature of external objects or ambient air. Remember that a discrete diode’s temperature will be affected, and often dominated, by the temperature of its leads. Most silicon diodes do not lend themselves well to this application. It is recommended that a 2N3904 transistor base emitter junction be used with the collector tied to the base. An LM89 with a diode-connected 2N3904 approximates the temperature reading of the LM89 with a Pentium 4 microprocessor less 1˚C. T2N3904 = TP4 − 1˚C The additional inaccuracy in the temperature measurement caused by η, can be eliminated if each temperature sensor is calibrated with the remote diode that it will be paired with. 3.1 DIODE NON-IDEALITY η, non-ideality Processor Family 3.1.1 Diode Non-Ideality Factor Effect on Accuracy When a transistor is connected as a diode, the following relationship holds for variables VBE, T and If: Pentium III CPUID 67h where: min typ max 1 1.0065 1.0125 Pentium III CPUID 68h/PGA370Socket/Celeron 1.0057 1.008 1.0125 Pentium 4, 423 pin 0.9933 1.0045 1.0368 Pentium 4, 478 pin 0.9933 1.0045 1.0368 0.13 micron, Pentium 4 1.0011 1.0021 1.0030 MMBT3904 AMD Athlon MP model 6 • • • • 1.003 1.002 1.008 1.016 3.1.2 Compensating for Diode Non-Ideality In order to compensate for the errors introduced by nonideality, the temperature sensor is calibrated for a particular processor. National Semiconductor temperature sensors are always calibrated to the typical non-ideality of a given processor type. The LM89 is calibrated for the non-ideality of a 0.13 micron, Mobile Pentium 4, 1.0021. When a temperature sensor calibrated for a particular processor type is used with a different processor type or a given processor type has a non-ideality that strays from the typical, errors are introduced. q = 1.6x10−19 Coulombs (the electron charge), T = Absolute Temperature in Kelvin k = 1.38x10−23joules/K (Boltzmann’s constant), η is the non-ideality factor of the process the diode is manufactured on, IS = Saturation Current and is process dependent, If = Forward Current through the base emitter junction • • • VBE = Base Emitter Voltage drop In the active region, the -1 term is negligible and may be eliminated, yielding the following equation Temperature errors associated with non-ideality may be reduced in a specific temperature range of concern through use of the offset registers (11h and 12h). Please send an email to [email protected] requesting further information on our recommended setting of the offset register for different processor types. In the above equation, η and IS are dependant upon the process that was used in the fabrication of the particular diode. By forcing two currents with a very controlled ratio (N) and measuring the resulting voltage difference, it is possible to eliminate the IS term. Solving for the forward voltage difference yields the relationship: The voltage seen by the LM89 also includes the IFRS voltage drop of the series resistance. The non-ideality factor, η, is the only other parameter not accounted for and depends on 17 www.national.com LM89 3.0 Applications Hints LM89 3.0 Applications Hints 4. (Continued) 3.2 PCB LAYOUT for MINIMIZING NOISE Diode traces should be surrounded by a GND guard ring to either side, above and below if possible. This GND guard should not be between the D+ and D− lines. In the event that noise does couple to the diode lines it would be ideal if it is coupled common mode. That is equally to the D+ and D− lines. 5. Avoid routing diode traces in close proximity to power supply switching or filtering inductors. 6. Avoid running diode traces close to or parallel to high speed digital and bus lines. Diode traces should be kept at least 2cm apart from the high speed digital traces. 7. If it is necessary to cross high speed digital traces, the diode traces and the high speed digital traces should cross at a 90 degree angle. 8. The ideal place to connect the LM89’s GND pin is as close as possible to the Processors GND associated with the sense diode. 20041517 FIGURE 11. Ideal Diode Trace Layout In a noisy environment, such as a processor mother board, layout considerations are very critical. Noise induced on traces running between the remote temperature diode sensor and the LM89 can cause temperature conversion errors. Keep in mind that the signal level the LM89 is trying to measure is in microvolts. The following guidelines should be followed: 1. VDD should be bypassed with a 0.1µF capacitor in parallel with 100pF. The 100pF capacitor should be placed as close as possible to the power supply pin. A bulk capacitance of approximately 10µF needs to be in the near vicinity of the LM89. 2. A 2.2nF diode bypass capacitor is required to filter high frequency noise. Place the 2.2nF capacitor as close as possible to the LM89’s D+ and D− pins. Make sure the traces to the 2.2nF capacitor are matched. 3. Ideally, the LM89 should be placed within 10cm of the Processor diode pins with the traces being as straight, short and identical as possible. Trace resistance of 1Ω can cause as much as 1˚C of error. This error can be compensated by using the Remote Temperature Offset Registers, since the value placed in these registers will automatically be subtracted from or added to the remote temperature reading. www.national.com 9. Leakage current between D+ and GND should be kept to a minimum. One nano-ampere of leakage can cause as much as 1˚C of error in the diode temperature reading. Keeping the printed circuit board as clean as possible will minimize leakage current. Noise coupling into the digital lines greater than 400mVp-p (typical hysteresis) and undershoot less than 500mV below GND, may prevent successful SMBus communication with the LM89. SMBus no acknowledge is the most common symptom, causing unnecessary traffic on the bus. Although the SMBus maximum frequency of communication is rather low (100kHz max), care still needs to be taken to ensure proper termination within a system with multiple parts on the bus and long printed circuit board traces. An RC lowpass filter with a 3db corner frequency of about 40MHz is included on the LM89’s SMBCLK input. Additional resistance can be added in series with the SMBData and SMBCLK lines to further help filter noise and ringing. Minimize noise coupling by keeping digital traces out of switching power supply areas as well as ensuring that digital lines containing high speed data communications cross at right angles to the SMBData and SMBCLK lines. 18 LM89 Physical Dimensions inches (millimeters) unless otherwise noted 8-Lead (0.150" Wide) Molded Narrow Small-Outline Package (SOIC), JEDEC Registration Number MS-012 Order Number LM89CIM or LM89CIMX NS Package Number M08A 8-Lead Molded Mini-Small-Outline Package (MSOP), JEDEC Registration Number MO-187 Order Number LM89CIMM or LM89CIMMX NS Package Number MUA08A 19 www.national.com LM89 ± 0.75˚C Accurate, Remote Diode and Local Digital Temperature Sensor with Two-Wire Interface Notes National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications. For the most current product information visit us at www.national.com. LIFE SUPPORT POLICY NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. BANNED SUBSTANCE COMPLIANCE National Semiconductor certifies that the products and packing materials meet the provisions of the Customer Products Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain no ‘‘Banned Substances’’ as defined in CSP-9-111S2. National Semiconductor Americas Customer Support Center Email: [email protected] Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Customer Support Center Fax: +49 (0) 180-530 85 86 Email: [email protected] Deutsch Tel: +49 (0) 69 9508 6208 English Tel: +44 (0) 870 24 0 2171 Français Tel: +33 (0) 1 41 91 8790 National Semiconductor Asia Pacific Customer Support Center Email: [email protected] National Semiconductor Japan Customer Support Center Fax: 81-3-5639-7507 Email: [email protected] Tel: 81-3-5639-7560