NSC SCANSTA112SM

SCANSTA112
7-Port Multidrop IEEE 1149.1 (JTAG) Multiplexer
General Description
Features
The SCANSTA112 extends the IEEE Std. 1149.1 test bus
into a multidrop test bus environment. The advantage of a
multidrop approach over a single serial scan chain is improved test throughput and the ability to remove a board
from the system and retain test access to the remaining
modules. Each SCANSTA112 supports up to 7 local
IEEE1149.1 scan chains which can be accessed individually
or combined serially.
Addressing is accomplished by loading the instruction register with a value matching that of the Slot inputs. Backplane
and inter-board testing can easily be accomplished by parking the local TAP Controllers in one of the stable TAP Controller states via a Park instruction. The 32-bit TCK counter
enables built in self test operations to be performed on one
port while other scan chains are simultaneously tested.
The STA112 has a unique feature in that the backplane port
and the LSP0 port are bidirectional. They can be configured
to alternatively act as the master or slave port so an alternate
test master can take control of the entire scan chain network
from the LSP0 port while the backplane port becomes a
slave.
n True IEEE 1149.1 hierarchical and multidrop
addressable capability
n The 8 address inputs support up to 249 unique slot
addresses, an Interrogation Address, Broadcast
Address, and 4 Multi-cast Group Addresses (address
000000 is reserved)
n 7 IEEE 1149.1-compatible configurable local scan ports
n Bi-directional Backplane and LSP0 ports are
interchangeable slave ports
n Capable of ignoring TRST of the backplane port when it
becomes the slave.
n Stitcher Mode bypasses level 1 and 2 protocols
n Mode Register0 allows local TAPs to be bypassed,
selected for insertion into the scan chain individually, or
serially in groups of two or three
n Transparent Mode can be enabled with a single
instruction to conveniently buffer the backplane IEEE
1149.1 pins to those on a single local scan port
n General purpose local port pass through bits are useful
for delivering write pulses for Flash programming or
monitoring device status.
n Known Power-up state
n TRST on all local scan ports
n 32-bit TCK counter
n 16-bit LFSR Signature Compactor
n Local TAPs can become TRI-STATE via the OE input to
allow an alternate test master to take control of the local
TAPs (LSP0-3 have a TRI-STATE notification output)
n 3.0-3.6V VCC Supply Operation
n Supports live insertion/withdrawal
20051250
FIGURE 1. Typical use of SCANSTA112 for board-level management of multiple scan chains.
© 2005 National Semiconductor Corporation
DS200512
www.national.com
SCANSTA112 7-port Multidrop IEEE 1149.1 (JTAG) Multiplexer
October 2005
SCANSTA112
20051251
FIGURE 2. Example of SCANSTA112 in a multidrop addressable backplane.
Introduction
Architecture
The SCANSTA112 is the third device in a series that enable
multi-drop address and multiplexing of IEEE-1149.1 scan
chains. The SCANSTA112 is a superset of its predecessors
- the SCANPSC110 and the SCANSTA111. The STA112 has
all features and functionality of these two previous devices.
The STA112 is essentially a support device for the IEEE
1149.1 standard. It is primarily used to partition scan chains
into managable sizes, or to isolate specific devices onto a
seperate chain (Figure 1). The benefits of multiple scan
chains are improved fault isolation, faster test times, faster
programiing times, and smaller vector sets.
In addition to scan chain partitioning, the device is also
addressable for use in a multidrop backplane environment
(Figure 2). In this configuration, multiple IEEE-1149.1 accessible cards with an STA112 on board can utilize the same
backplane test bus for system-level IEEE-1149.1 access.
This approach facilitates a system-wide commitment to
structural test and programming throughout the entire system life sycle.
Figure 3 shows the basic architecture of the ’STA112. The
device’s major functional blocks are illustrated here.
www.national.com
The TAP Controller, a 16-state state machine, is the central
control for the device. The instruction register and various
test data registers can be scanned to exercise the various
functions of the ’STA112 (these registers behave as defined
in IEEE Std. 1149.1).
The ’STA112 selection controller provides the functionality
that allows the 1149.1 protocol to be used in a multi-drop
environment. It primarily compares the address input to the
slot identification and enables the ’STA112 for subsequent
scan operations.
The Local Scan Port Network (LSPN) contains multiplexing
logic used to select different port configurations. The LSPN
control block contains the Local Scan Port Controllers
(LSPC) for each Local Scan Port (LSP0, LSP1 ... LSPn). This
control block receives input from the ’STA112 instruction
register, mode registers, and the TAP controller. Each local
port contains all four boundary scan signals needed to interface with the local TAPs plus the optional Test Reset signal
(TRST).
The TDI/TDO Crossover Master/Slave logic is used to define
the bidirectional B0 and B1 ports in a Master/Slave
configuration.
2
SCANSTA112
Block Diagram
20051202
FIGURE 3. SCANSTA112 Block Diagram
3
www.national.com
SCANSTA112
Connection Diagrams
20051201
(BGA Top view)
www.national.com
4
SCANSTA112
Connection Diagrams
(Continued)
20051260
TQFP pinout
5
www.national.com
SCANSTA112
TABLE 1. Pin Descriptions
No.
Pins
I/O
VCC
10
N/A
Power
GND
10
N/A
Ground
Pin Name
Description
RESET
1
I
RESET Input: will force a reset of the device regardless of the current state.
ADDMASK
1
I
ADDRESS MASK input: Allows masking of lower slot input pins.
MPselB1/B0
1
I
MASTER PORT SELECTION: Controls selection of LSPB0 or LSPB1 as the backplane port.
The unselected port becomes LSP00. A value of "0" will select LSPB0 as the master port.
SB/S
1
I
Selects ScanBridge or Stitcher Mode.
7
I
In Stitcher Mode these inputs define which LSP’s are to be included in the scan chain
TRANS
1
I
Transparent Mode enable input: The value of this pin is loaded into the TRANSENABLE bit
of the control register at power-up. This value is used to control the presence of registers
and pad-bits in the scan chain while in the stitcher mode.
TLR_TRST
1
I
Sets the driven value of TRST0-5 when LSP TAPs are in TLR and the device is not being
reset. During RESET = "0" or TRSTB = "0" (IgnoreReset = "0") TRSTn = "0". This pin is to be
tied low to match the function of the SCANSTA111
TLR_TRST6
1
I
This pin affects TRST of LSP6 only. This pin is to be tied low to match the function of the
SCANSTA111
TDIB0, TDIB1
2
I
BACKPLANE TEST DATA INPUT: All backplane scan data is supplied to the ’STA112
through this input pin. MPselB1/B0 determines which port is the master backplane port and
which is LSP00. This input has a 25KΩ internal pull-up resistor and no ESD clamp diode
(ESD is controlled with an alternate method). When the device is power-off (VDD floating),
this input appears to be a capacitive load to ground (Note 1). When VDD = 0V (i.e.; not
floating but tied to VSS) this input appears to be a capacitive load with the pull-up to ground.
TMSB0, TMSB1
2
I/O
BACKPLANE TEST MODE SELECT: Controls sequencing through the TAP Controller of the
’STA112. Also controls sequencing of the TAPs which are on the local scan chains.
MPselB1/B0 determines which port is the master backplane port and which is LSP00. This
bidirectional TRI-STATE pin has 24mA of drive current, with a 25KΩ internal pull-up resistor
and no ESD clamp diode (ESD is controlled with an alternate method). When the device is
power-off (VDD floating), this input appears to be a capacitive load to ground (Note 1). When
VDD = 0V (i.e.; not floating but tied to VSS) this input appears to be a capacitive load with the
pull-up to ground.
TDOB0, TDOB1
2
I/O
BACKPLANE TEST DATA OUTPUT: This output drives test data from the ’STA112 and the
local TAPs, back toward the scan master controller. This bidirectional TRI-STATE pin has
12mA of drive current. MPselB1/B0 determines which port is the master backplane port and
which is LSP00. Output is sampled during interrogation addressing. When the device is
power-off (VDD = 0V or floating), this output appears to be a capacitive load (Note 1).
TCKB0, TCKB1
2
I/O
TEST CLOCK INPUT FROM THE BACKPLANE: This is the master clock signal that controls
all scan operations of the ’STA112 and of the local scan ports. MPselB1/B0 determines which
port is the master backplane port and which is LSP00. These bidirectional TRI-STATE pins
have 24mA of drive current with hysterisis. This input has no pull-up resistor and no ESD
clamp diode (ESD is controlled with an alternate method). When the device is power-off (VDD
floating), this input appears to be a capacitive load to ground (Note 1). When VDD = 0V (i.e.;
not floating but tied to VSS) this input appears to be a capacitive load to ground.
TRSTB0, TRSTB1
2
I/O
TEST RESET: An asynchronous reset signal (active low) which initializes the ’STA112 logic.
MPselB1/B0 determines which port is the master backplane port and which is LSP00. This
bidirectional TRI-STATE pin has 24mA of drive current, with a 25KΩ internal pull-up resistor
and no ESD clamp diode (ESD is controlled with an alternate method). When the device is
power-off (VDD floating), this pin appears to be a capacitive load to ground (Note 1). When
VDD = 0V (i.e.; not floating but tied to VSS) this input appears to be a capacitive load with the
pull-up to ground.
LSPsel
(0-6)
www.national.com
6
SCANSTA112
TABLE 1. Pin Descriptions
(Continued)
No.
Pins
I/O
TRISTB0, TRISTB1,
TRIST(01-03)
5
O
TRI-STATE NOTIFICATION OUTPUT: This signal is asserted high when the associated
TDO is TRI-STATEd. Associated means TRISTB0 is for TDOB0, TRIST01 is for TDO01, etc.
This output has 12mA of drive current.
A0B0, A1B0, A0B1,
A1B1
4
I
BACKPLANE PASS-THROUGH INPUT: A general purpose input which is driven to the Yn of
a single selected LSP. (Not available when multiple LSPs are selected). This input has a
25KΩ internal pull-up resistor. MPselB1/B0 determines which port is the master backplane
port and which is LSP00.
Y0B0, Y1B0, Y0B1,
Y1B1
4
O
BACKPLANE PASS-THROUGH OUTPUT: A general purpose output which is driven from
the An of a single selected LSP. (Not available when multiple LSPs are selected). This
TRI-STATE output has 12mA of drive current. MPselB1/B0 determines which port is the
master backplane port and which is LSP00.
S(0-7)
8
I
SLOT IDENTIFICATION: The configuration of these pins is used to identify (assign a unique
address to) each ’STA112 on the system backplane
OE
1
I
OUTPUT ENABLE for the Local Scan Ports, active low. When high, this active-low control
signal TRI-STATEs all local scan ports on the ’STA112, to enable an alternate resource to
access one or more of the local scan chains.
TDO(01-06)
6
O
TEST DATA OUTPUTS: Individual output for each of the local scan ports . These
TRI-STATE outputs have 12mA of drive current.
TDI(01-06)
6
I
TEST DATA INPUTS: Individual scan data input for each of the local scan ports. This input
has a 25KΩ internal pull-up resistor.
TMS(01-06)
6
O
TEST MODE SELECT OUTPUTS: Individual output for each of the local scan ports. TMSn
does not provide a pull-up resistor (which is assumed to be present on a connected TMS
input, per the IEEE 1149.1 requirement) . These TRI-STATE outputs have 24mA of drive
current.
TCK(01-06)
6
O
LOCAL TEST CLOCK OUTPUTS: Individual output for each of the local scan ports. These
are buffered versions of TCKB . These TRI-STATE outputs have 24mA of drive current.
TRST(01-06)
6
O
LOCAL TEST RESETS: A gated version of TRSTB. These TRI-STATE outputs have 24mA
of drive current.
A001, A101
2
I
LOCAL PASS-THROUGH INPUTS: General purpose inputs which can be driven to the
backplane pin YB. (Only on LSP0 and LSP1. Only available when a single LSP is selected) .
These inputs have a 25KΩ internal pull-up resistor.
Y001, Y101
2
O
LOCAL PASS-THROUGH OUTPUT: General purpose outputs which can be driven from the
backplane pin AB. (Only on LSP0 and LSP1. Only available when a single LSP is selected) .
These TRI-STATE outputs have 12mA of drive current.
Pin Name
Description
Note 1: Refer to the IBIS model on our website for I/O characteristics.
munication protocol. Second, within each selected ’STA112,
a test controller can select one or more of the chip’s seven
local scan-ports. That is, individual local ports can be selected for inclusion in the (single) scan-chain which a
’STA112 presents to the test controller. This mechanism
allows a controller to select specific scan-chains within the
overall scan network. The port-selection process is supported by a Level-2 protocol.
Application Overview
ADDRESSING SCHEME
The SCANSTA112 architecture extends the functionality of
the IEEE 1149.1 Standard by supplementing that protocol
with an addressing scheme which allows a test controller to
communicate with specific ’STA112s within a network of
’STA112s. That network can include both multi-drop and
hierarchical connectivity. In effect, the ’STA112 architecture
allows a test controller to dynamically select specific portions
of such a network for participation in scan operations. This
allows a complex system to be partitioned into smaller
blocks for testing purposes. The ’STA112 provides two levels
of test-network partitioning capability. First, a test controller
can select individual ’STA112s, specific sets of ’STA112s
(multi-cast groups), or all ’STA112s (broadcast). This
’STA112-selection process is supported by a Level-1 com-
HIERARCHICAL SUPPORT
Multiple SCANSTA112’s can be used to assemble a hierarchical boundary-scan tree. In such a configuration, the system tester can configure the local ports of a set of ’STA112s
so as to connect a specific set of local scan-chains to the
active scan chain. Using this capability, the tester can selectively communicate with specific portions of a target system.
The tester’s scan port is connected to the backplane scan
port of a root layer of ’STA112s, each of which can be
7
www.national.com
SCANSTA112
Application Overview
mux’ing function and enable the connection (UNPARK) between the local scan chain and the backplane bus via an
LSP. Upon completion of level 1 and 2 protocols the ScanBridge is prepared for its operational mode. This is where
scan vectors are moved from the backplane bus to the
desired local scan chain(s).
(Continued)
selected using multi-drop addressing. A second tier of
’STA112s can be connected to this root layer, by connecting
a local port (LSP) of a root-layer ’STA112 to the backplane
port of a second-tier ’STA112. This process can be continued
to construct a multi-level scan hierarchy. ’STA112 local ports
which are not cascaded into higher-level ’STA112s can be
thought of as the terminal leaves of a scan tree. The test
master can select one or more target leaves by selecting and
configuring the local ports of an appropriate set of ’STA112s
in the test tree.
STITCHER MODE
Stitcher Mode is a method of skipping level 1 and 2 protocol
of the ScanBridge mode of operation. This is accomplished
via external pins. When in stitcher mode the SCANSTA112
will go directly to the operational mode.
STANDARD SCANBRIDGE MODE
TRANSPARENT MODE
ScanBridge mode refers to functionality and protocol that
has been used by National since the introduction of the
PSC110 in 1993. This functionality consists of a multidrop
addressable IEEE1149.1 switch. This enables one (or more)
device to be selected from many that are connected to a
parallel IEEE1149.1 bus or backplane. The second function
that ScanBridge mode accomplishes is to act as a mux for
multiple IEEE1149.1 local scan chains. The Local Scan
Ports (LSP) of the device creates a connection between one
or more of the local scan chains to the backplane bus.
Transparent mode refers to a condition of operation in which
there are no pad-bits or SCANSTA112 registers in the scan
chain. The Transparent mode of operation is available in
both ScanBridge and Stitcher modes. Only the activation
method differs. Once transparent mode has been activated
there is no difference in operation. Transparent mode allows
for the use of vectors that have been generated for a chain
where these bits were not included.
Check with your ATPG tool vendor to ensure support of
these features.
To accomplish this functionality the ScanBridge has two
levels of protocol and an operational mode. Level 1 protocol
refers to the required actions to address/select the desired
ScanBridge. Level 2 protocol is required to configuring the
www.national.com
For details regarding the internal operation of the SCANSTA112 device, refer to applications note AN-1259 SCANSTA112 Designers Reference.
8
Supply Voltage (VCC)
−0.3V to +4.0V
100L FBGA
35˚C/W
100L TQFP
59.1˚C/W
Package Derating above +25˚C
DC Input Diode Current (IIK)
VI = −0.5V
−20 mA
DC Input Voltage (VI)
−0.5V to +3.9V
−20 mA
DC Output Voltage (VO)
−0.3V to +3.9V
DC VCC or Ground Current
per Output Pin
Junction Temperature (Plastic)
’STA112
+150˚C
Storage Temperature
2500V
Supply Voltage (VCC)
± 300 mA
DC Latchup Source or Sink Current
16.92mW/˚C
Recommended Operating
Conditions
± 50 mA
± 50 mA
DC Output Source/Sink Current (IO)
28.57mW/˚C
100L TQFP
ESD Last Passing Voltage
(HBM Min)
DC Output Diode Current (IOK)
VO = −0.5V
100L FBGA
−65˚C to +150˚C
Lead Temperature (Solder, 4sec)
3.0V to 3.6V
Input Voltage (VI)
0V to VCC
Output Voltage (VO)
0V to VCC
Operating Temperature (TA)
100L FBGA
220˚C
100L TQFP
220˚C
Industrial
Note 2: Absolute maximum ratings are those values beyond which damage
to the device may occur. The databook specifications should be met, without
exception, to ensure that the system design is reliable over its power supply,
temperature, and output/input loading variables. National does not recommend operation of SCAN STA products outside of recommended operation
conditions.
Max Package Power Capacity @
25˚C
100L FBGA
3.57W
100L TQFP
2.11W
−40˚C to +85˚C
Thermal Resistance (θJA)
DC Electrical Characteristics
Over recommended operating supply voltage and temperature ranges unless otherwise specified
Symbol
VIH
Parameter
Conditions
Minimum High Input Voltage
VOUT = 0.1V or
Min
Max
2.1
Units
V
VCC −0.1V
VIL
Maximum Low Input Voltage
VOUT = 0.1V or
VOH
Minimum High Output Voltage
IOUT = −100 µA
All Outputs and I/O Pins
VIN = VIH or VIL
0.8
V
VCC −0.1V
VOH
VOH
Minimum High Output Voltage
IOUT = −12 mA
TDOB0, TDOB1, TRISTB0, TRISTB1, Y0B0, Y1B0,
Y0B1, Y1B1, TDO(01-06), Y001, Y101, TRIST(01-03)
All Outputs Loaded
Minimum High Output Voltage
IOUT = −24mA
VCC - 0.2v
V
2.4
V
2.2
V
TMSB0, TMSB1, TCKB0, TCKB1, TRSTB0, TRSTB1,
TMS(01-06), TCK(01-06), TRST(01-06)
VOL
VOL
Maximum Low Output Voltage
IOUT = +100 µA
All Outputs and I/O Pins
VIN = VIH or VIL
0.2
V
Maximum Low Output Voltage
IOUT = +12 mA
0.4
V
IOUT = +24mA
0.55
V
Maximum Input Clamp Diode Voltage
IIK = -18mA
-1.2
V
Maximum Input Leakage Current
VIN = VCC or GND
± 5.0
µA
TDOB0, TDOB1, TRISTB0, TRISTB1, Y0B0, Y1B0,
Y0B1, Y1B1, TDO(01-06), Y001, Y101, TRIST(01-03)
VOL
Maximum Low Output Voltage
TMSB0, TMSB1, TCKB0, TCKB1, TRSTB0, TRSTB1,
TMS(01-06), TCK(01-06), TRST(01-06)
VIKL
IIN
(non-resistor input pins)
9
www.national.com
SCANSTA112
Absolute Maximum Ratings (Note 2)
SCANSTA112
DC Electrical Characteristics
(Continued)
Over recommended operating supply voltage and temperature ranges unless otherwise specified
Symbol
IILR
Parameter
Conditions
Input Current Low
VIN = GND
Min
Max
Units
-45
-200
µA
5.0
µA
± 5.0
µA
± 200
± 5.0
µA
(Input and I/O pins with pull-up resistors: TDIB0,
TDIB1, TMSB0, TMSB1, TRSTB0, TRSTB1, A0B0,
A1B0, A0B1, A1B1, TDI(01-06), A001, A101)
IIH
Input High Current
(Input and I/O pins with pull-up resistors: TDIB0,
TDIB1, TMSB0, TMSB1, TRSTB0, TRSTB1, A0B0,
A1B0, A0B1, A1B1, TDI(01-06), A001, A101)
VIN = VCC
IOFF
Power-off Leakage Current
Outputs and I/O pins without pull-up resistors
VCC = 0V, VIN = 3.6V
(Note 3)
Outputs and I/O pins with pull-up resistors
IOZ
Maximum TRI-STATE Leakage Current
µA
Outputs and I/O pins without pull-up resistors
ICC
Maximum Quiescent Supply Current
VIN = VCC or GND
3.8
mA
ICCD
Maximum Dynamic Supply Current
VIN = VCC or GND, Input
Freq = 25MHz
68
mA
Typ
Max
Units
8.5
13.5
ns
8.5
14.0
ns
7.5
12.5
ns
7.5
13.0
ns
8.0
12.0
ns
8.0
12.0
ns
8.0
12.0
ns
8.0
12.0
ns
8.0
12.0
ns
8.0
12.0
ns
7.5
12.0
ns
7.5
12.0
ns
11.5
18.0
ns
11.5
18.0
ns
Note 3: Guaranteed by equivalent test method.
AC Electrical Characteristics: Scan Bridge Mode
Over recommended operating supply voltage and temperature ranges unless otherwise specified (Note 5).
Symbol
Parameter
tPHL,
Propagation Delay
tPLH
TCKB0 to TDOB0 or TDOB1
tPHL,
Propagation Delay
tPLH
TCKB1 to TDOB0 or TDOB1
tPHL,
Propagation Delay
tPLH
TCKB0 to TDO(01-06)
tPHL,
Propagation Delay
tPLH
TCKB1 to TDO(01-06)
tPHL,
Propagation Delay
tPLH
TMSB0 to TMSB1
tPHL,
Propagation Delay
tPLH
TMSB1 to TMSB0
tPHL,
Propagation Delay
tPLH
TMSB0 to TMS(01-06)
tPHL,
Propagation Delay
tPLH
TMSB1 to TMS(01-06)
tPHL,
Propagation Delay
tPLH
TCKB0 to TCKB1
tPHL,
Propagation Delay
tPLH
TCKB1 to TCKB0
tPHL,
Propagation Delay
tPLH
TCKB0 to TCK(01-06)
tPHL,
Propagation Delay
tPLH
TCKB1 to TCK(01-06)
tPHL,
Propagation Delay
tPLH
TCKB0 to TRSTB1
tPHL,
Propagation Delay
tPLH
TCKB1 to TRSTB0
www.national.com
Conditions
10
(Continued)
Over recommended operating supply voltage and temperature ranges unless otherwise specified (Note 5).
Symbol
Parameter
tPHL,
Propagation Delay
tPLH
TCKB0 to TRST(01-06)
tPHL,
Propagation Delay
tPLH
TCKB1 to TRST(01-06)
tPHL
Propagation Delay
Conditions
Typ
Max
Units
12.0
18.5
ns
12.0
18.5
ns
8.5
12.5
ns
8.0
12.0
ns
9.0
14.5
ns
6.0
9.0
ns
Max
Units
TCKBn to TRISTBn
tPHL
Propagation Delay
TCKBn to TRIST(01-03)
tPZL,
Propagation Delay
tPZH
TCKBn to TDOBn or TDO(01-06)
tPHL,
Propagation Delay
tPLH
An to Yn
AC Timing Characteristics: Scan Bridge Mode
Over recommended operating supply voltage and temperature ranges unless otherwise specified (Notes 4, 5).
Symbol
tS
Parameter
Conditions
Setup Time
Min
2.5
ns
1.5
ns
3.0
ns
2.0
ns
1.0
ns
3.5
ns
1.0
ns
tR/tF = 1.0ns
10.0
ns
tR/tF = 1.0ns
2.5
ns
tR/tF = 1.0ns
25
MHz
TMSBn to TCKBn
tH
Hold Time
TMSBn to TCKBn
tS
Setup Time
TDIBn to TCKBn
tH
Hold Time
TDIBn to TCKBn
tS
Setup Time
TDI(01-06) to TCKBn
tH
Hold Time
TDI(01-06) to TCKBn
tREC
Recovery Time
TCKBn from TRSTBn
tW
Clock Pulse Width
TCKBn(H or L)
tWL
Reset Pulse Width
TRSTBn(L)
FMAX
Maximum Clock Frequency (Note 6)
Note 4: Guaranteed by Design (GBD) by statistical analysis
Note 5: RL = 500Ω to GND, CL = 50pF to GND, tR/tF = 2.5ns, Frequency = 25MHz, VM = 1.5V
Note 6: When sending vectors one-way to a target device on an LSP (such as in FPGA/PLD configuration/programming), the clock frequency may be increased
above this specification. In Scan Mode (expecting to capture returning data at the LSP), the FMAX must be limited to the above specification.
11
www.national.com
SCANSTA112
AC Electrical Characteristics: Scan Bridge Mode
SCANSTA112
AC Electrical Characteristics: Stitcher Transparent Mode
Over recommended operating supply voltage and temperature ranges unless otherwise specified (Note 5).
Symbol
Parameter
tPHL,
Propagation Delay
tPLH
TDIB0 to TDOB1, TDIB1 to TDOB0
tPHL,
Propagation Delay
tPLH
TDIB0 to TDO01, TDIB1 to TDO01
tPHL,
Propagation Delay
tPLH
TDILSPn to TDOLSPn+1
tPHL,
Propagation Delay
tPLH
TMSB0 to TMSB1, TMSB1 to TMSB0
tPHL,
Propagation Delay
tPLH
TMSB0 to TMS(01-06), TMSB1 to TMS(01-06)
tPHL,
Propagation Delay
tPLH
TRSTB0 to TRSTB1, TRSTB1 to TRSTB0
tPHL,
Propagation Delay
tPLH
TRSTB0 to TRST(01-06), TRSTB1 to TRST(01-06)
Conditions
Typ
Timing Diagrams
20051236
Waveforms for an Unparked STA112 in the Shift-DR (IR) TAP Controller State
www.national.com
12
Max
Units
12.5
ns
12.5
ns
12.5
ns
12.5
ns
12.5
ns
12.5
ns
12.5
ns
SCANSTA112
Timing Diagrams
(Continued)
20051238
Reset Waveforms
20051239
Output Enable Waveforms
Capacitance & I/O Characteristics
Refer to National’s website for IBIS models at http://www.national.com/scan
13
www.national.com
SCANSTA112
Physical Dimensions
inches (millimeters) unless otherwise noted
100-Pin BGA
NS Package Number SLC100a
Ordering Code SCANSTA112SM
100-Pin TQFP
NS Package Number VJD100a
Ordering Code SCANSTA112VS
www.national.com
14
SCANSTA112 7-port Multidrop IEEE 1149.1 (JTAG) Multiplexer
Notes
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves
the right at any time without notice to change said circuitry and specifications.
For the most current product information visit us at www.national.com.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body, or
(b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result
in a significant injury to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or
system, or to affect its safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor manufactures products and uses packing materials that meet the provisions of the Customer Products
Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain
no ‘‘Banned Substances’’ as defined in CSP-9-111S2.
Leadfree products are RoHS compliant.
National Semiconductor
Americas Customer
Support Center
Email: [email protected]
Tel: 1-800-272-9959
www.national.com
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
Email: [email protected]
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
National Semiconductor
Asia Pacific Customer
Support Center
Email: [email protected]
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: [email protected]
Tel: 81-3-5639-7560