DC centrifugal fans 2016 01 EN

Accessories
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
DC fans - specials
91
DC centrifugal fans
93
95
138
140
Representatives
DC centrifugal fan overview
DC centrifugal fans
DC tangential fans
DC centrifugal fans and blowers
2016-01
DC axial fans
Information
DC centrifugal fans
DC centrifugal fans
Technical information
Product line
Voltage range
Our centrifugal product line includes fans for every application. Whether
Many of our DC fans can be operated on voltages that are up to 50%
as free-running impellers with a diameter between 97 mm and 225 mm,
lower and 25% higher than their nominal voltage (see voltage range in
or as assemblies in a ready-to-install, compact housing with inlet ring
the technical tables). This allows the air performance to be adapted to the
with an edge length between 51 mm and 270 mm. Of course, all models
cooling requirements and the noise to be reduced, even if the fan does
feature highly efficient, brushless motor technology.
not have a control input.
Electronic protection against reverse polarity
Closed-loop speed control and monitoring
ebm-papst DC fans have electronically commutated drives with electronic
Closed-loop speed control and function monitoring are becoming
protection against reverse polarity. The electronics are integrated in the
increasingly important in many applications. ebm-papst offers many fans
fan’s impeller hub to save space.
in the standard design with a control input and open-collector speed
signal.
Product life expectancy
A distinctive feature of DC fan technology is the amazing product life
S-Force centrifugal RadiCal
expectancy. The outstanding efficiency of the brushless drive results in
The new S-Force centrifugal fans provide peak performance among fans
lower heat stress for the bearings, which significantly increases the
of this type. With air flow capacity of over 1500 m³/h and a pressure
service life of the fan.
increase of up to 1000 pascals, the highest heat flows are manageable.
The models are extremely efficient due to the multi-pole, electronically
Degree of protection
commutated drive motors, and can be adapted individually to every
DC fans with sleeve and ball bearings are powered by class E insulated
application thanks to intelligent motor features. Some models use our
motors. All ebm-papst fans conform to the requirements of degree of
new, highly efficient RadiCal impellers.
protection IP 20. Fans conforming to IP 54 / IP 68 and special degrees of
2016-01
protection are also available.
92
Information
Page
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000 2500
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
114
116
117
118
119
120
121
122
124
126
128
129
130
132
134
136
138
140
142
144
146
148
150
152
154
156
158
160
162
NEW
Subject to change
10
20
30
40
50
60
70 80 90 100
200
300
400
500 600 700 800 900 1000
2000 2500
93
2016-01
m3/h
DC centrifugal fans
60
DC fans - specials
50
ACmaxx / EC fans
40
AC axial fans
18...24
9.6
22...28
56...61
40...55
64...80
55
60...137
118
139...209
59...444
630...930
1090...1100
1040...1450
220
86...104
162...190
320...390
250
110...166
460...565
255
360
800
600...980
650...970
880...930
1200...1215
1063...1250
1190...1600
1300...1340
1505...1640
2160...2190
2310...2380
75...155
95
95
200
255
225
400...410
465...470
505
700
1020
1000
980
30
AC centrifugal fans
RV 40
RLF 35
RL 48
RL 65
RL 90 N
RLF 100
RG 90 N
RG 125 N
RG 140 NTD
RG 160 N
RG 160 NTD
RG 190 TD
RG 220 TD
RG 225 TD
RET 97 TD
REF 100
RER 101 N
RER 120 TD
R1G 120
RER 125 N
RER 133 TD
RER 160 N
RER 160 NTD
REF 175 TD
RER 175 TD
RER 190 TD
R3G 190
R3G 220
RER 220 TD
RER 225 TD
R3G 225
R3G 250
R3G 280
R3G 310
QG 030
*1G 085
*1G 097
*1G 108
*1G 120
*1G 133
*1G 140
*1G 146
*1G 160
D1G 133
D1G 133
D1G 146
D1G 160
20
Accessories
105 x 59 x 79
51 x 15
c 76 x 27
97 x 93.5 x 33
c 121 x 37
c 127 x 25
c 135 x 38
c 180 x 40
c 180 x 40
c 220 x 56
c 220 x 56
c 226 x 85
c 270 x 99
c 270 x 119
Ø 97 x 41
Ø 104 x 25
Ø 101 x 52
Ø 120 x 54
Ø 120
Ø 138 x 35
Ø 133 x 91
Ø 165 x 51
Ø 165 x 51
Ø 175 x 55
Ø 175 x 69
Ø 190 x 69
Ø 190
Ø 220
Ø 220 x 71
Ø 225 x 99
Ø 225
Ø 250
Ø 280
Ø 310
201...413 x 50 x 48
Ø
85
Ø
97
Ø 108
Ø 120
Ø 133
Ø 140
Ø 146
Ø 160
Ø 133
Ø 133
Ø 146
Ø 160
10
Representatives
m3/h
mm
c
Air flow
Series
Dimension
Overview of air performance
DC axial fans
Centrifugal fans for DC operation
Centrifugal fans for DC operation
Spee
leev
EC s
SINT
Dim
VDE
, UL,
ensio
n
CSA
e be
ar
ings
d sig
/ ball
nal
bear
ings
Go /
NoG
o
alarm
Alarm
with
spee
d lim
Exte
rnal
it
t
e
m
pera
Inter
ture
nal t
emp
sens
eratu
PWM
o
re se r
cont
nsor
r
o
l inp
Analo
u
t
g co
ntro
l inp
Mult
ut
i-op
tions
cont
rol in
Mois
put
ture
prot
IP >
e
c
tion
= 54
IP 68
Salt
spra
y pro
tectio
n
Page
Overview of technically feasible designs
Centrifugal fans
mm
NEW
Series
OPTIONAL
P.
105 x 59 x 79
RV 40
•
•
–
–
–
–
–
–
–
•
–
–
–
95
c 51
x 15
RLF 35
yes
•
–
–
–
–
•
–
–
•
–
–
–
96
c 76
x 27
RL 48
yes
•
• •
•
• •
•
–
•
–
–
–
97
97 x 93.5 x 33
RL 65
yes
•
• •
•
• •
•
–
•
–
–
–
98
c 121
x 37
RL 90 N
yes
•
• •
•
• •
•
–
• • • •
99
c 127
x 25
RLF 100
yes
•
• •
•
• •
•
–
•
• – –
100
c 135
x 38
RG 90 N
yes
•
• •
•
• •
•
–
• • • •
101
c 180
x 40
RG 125 N
yes
•
• •
•
• •
•
–
• • • •
102
c 180
x 40
RG 140 NTD
yes
•
• •
•
– •
•
•
• • • •
103
c 220
x 56
RG 160 N
yes
•
• •
•
• •
•
–
• • – •
104
c 220
x 56
RG 160 NTD
yes
•
• •
•
• •
•
–
• • – •
105
c 226
x 85
RG 190 TD
yes
•
• •
•
• •
•
•
• • – •
106
c 270
x 99
RG 220 TD
yes
•
• •
•
• •
•
–
• • – •
107
c 270
x 132
RG 225 TD
yes
•
• •
•
• •
•
–
• • – •
108
Ø 97 x 41
RET 97 TD
yes
•
• •
•
• •
•
–
• – – –
109
Ø 100 x 25
REF 100
yes
•
• •
•
• •
•
–
•
• – –
110
Ø 101 x 52
RER 101 N
yes
•
• •
•
• •
•
–
• – – –
111
Ø 120 x 54
RER 120 TD
yes
•
• •
•
• •
•
–
• – – –
112
Ø 138 x 35
RER 125 N
yes
•
• •
•
• •
•
–
• • • •
116
Ø 133 x 91
RER 133 TD
yes
•
• •
•
• •
•
•
• • – •
117
Ø 165 x 51
RER 160 N
yes
•
• •
•
• •
•
–
• • – •
118
Ø 165 x 51
RER 160 NTD
yes
•
• •
•
• •
•
–
•
119
Ø 175 x 55
REF 175 TD
yes
•
• •
•
• •
•
•
• • – –
120
Ø 175 x 69
RER 175 TD
yes
•
• •
•
• •
•
•
• • – •
121
Ø 190 x 69
RER 190 TD
yes
•
• •
•
• •
•
•
• • – •
122
Ø 220 x 71
RER 220 TD
yes
•
• •
•
• •
•
•
• • – •
128
Ø 225 x 99
RER 225 TD
yes
•
• •
•
• •
•
•
• • – •
129
201...413 x 50 x 48
QG 030
yes
•
–
–
–
–
–
• – – –
138
/
/
/
–
–
• – –
Please note that these special versions are not possible
for all voltages and speeds, and not in all combinations.
The special versions are designed for specific
customers and projects. As a rule they are not available
off the shelf and are subject to minimum volumes.
Please consult your customer support representative
about the feasibility of your special variant.
Subject to change
– Not yet available
• Available
Sleeve bearings
Ball bearings
Optional special versions (see page 12)
On the catalog pages and in the overview on page 12, we provide
versions are designed for specific customers and projects and are
information about the special designs that are technically feasible in
usually not available off the shelf.
the fan series. Please note that these special versions are not possible
2016-01
for all voltages and speeds, and not in all combinations. The special
94
24 m /h
Information
Max.
DC centrifugal fans
3
105 x 59 x 79 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Direction of air flow: Axial: Intake,
- Moisture protection
Centrifugal: Exhaust
Connection:
via single wires AWG 26, TR 64
Highlights:
Forward-curved impeller
Weight:
100 g
–
–
–
DC centrifugal fans
–
DC axial fans
– Material:
RV 40-18/12 L
18
10.6
12
9...16
RV 40-18/12 H
24
14.1
12
9...16
Watts
rpm-1
°C
Hours
Hours
4.0
2.0
3 900
-20...+70
70 000 / 35 000
117 500
5.0
4.5
4 800
-20...+70
50 000 / 25 000
85 000
DC fans - specials
/
Curve
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
cfm
Temperature range
Nominal voltage
m3/h
Nominal data
Nominal speed
Air flow
Type
Series RV 40
Power consumption
Air flow
1) Fiberglass-reinforced plastic
¿
¡
Ø 30
Ø 31
2,3
45,78
60,4
27
42,04
Ø 40
Ø 46,5
Ansaugöffnung
10,5
Accessories
4,2 (2x)
18
36,35
12
58,85
2,51
44,9
32,4
95
Representatives
18,35
2016-01
Air performance measured according to:
ISO 5801.
Installation category A, without contact
protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m;
Sound pressure level LpA measured at 1 m
distance from fan axis.
The acoustic values are only valid for the
described measurement setup and may vary
depending on the installation situation.
In the event of deviation from the standard
configuration, the parameters must be checked
after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
Subject to change
Max.
9.6 m /h
DC centrifugal fans
3
 51 x 15 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal - PWM control input
Direction of air flow: Axial: Intake,
- Moisture protection
Centrifugal: Exhaust
Connection:
via single wires AWG 26, TR 64
Highlights:
Forward-curved impeller
Weight:
40 g
– Material:
–
–
–
–
6 700
-20...+70
60 000 / 30 000
102 500
5.5
4.3
6 700
-20...+70
60 000 / 30 000
102 500
VDC
VDC
Bel(A)
RLF 35-8/12 N
9.6
5.64
12
8...13.2
RLF 35-8/14 N
9.6
5.64
24
14...28
Subject to change
Tin-pla
te
d
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
96
Curve
3.5
cfm
Life expectancy L10IPC
(40 °C) see page 17
Temperature range
5.5
m3/h
Service life L10 (Tmax)
ebm-papst standard
Nominal speed
Hours
Type
Nominal data
Service life L10 (40 °C)
ebm-papst standard
Power consumption
Hours
Sound power level
°C
Voltage range
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RLF 35
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
¿
¿
28 m /h
Information
Max.
DC centrifugal fans
3
 76 x 27 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Direction of air flow: Axial: Intake,
- Go- / NoGo alarm
Centrifugal: Exhaust
- Alarm with speed limit
Connection:
via single wires AWG 26, TR 64
- External temperature sensor
Highlights:
Forward-curved impeller
- Internal temperature sensor
Weight:
75 g
- PWM control input
- Analog control input
- Moisture protection
–
–
–
DC centrifugal fans
–
DC axial fans
– Material:
RL 48-19/12 ML
22
12.9
12
8...15
5.3
5.0
RL 48-19/12
28
16.5
12
8...13.5
5.7
4.6
RL 48-19/14 ML
22
12.9
24
18...28
5.3
RL 48-19/14
28
16.5
24
18...26.4
5.7
rpm-1
°C
Hours
Hours
3 500
-20...+70
70 000 / 35 000
117 500
4 400
-20...+70
60 000 / 30 000
102 500
5.0
3 500
-20...+70
70 000 / 35 000
117 500
4.4
4 400
-20...+70
60 000 / 30 000
102 500
DC fans - specials
Watts
¿
¡
¿
¡
ACmaxx / EC fans
Power consumption
/
Curve
Sintec sleeve bearings
Ball bearings
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
Sound power level
VDC
Service life L10 (Tmax)
ebm-papst standard
Voltage range
VDC
AC centrifugal fans
AC axial fans
Subject to change
Tin-plate
Accessories
d
97
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Representatives
Type
Service life L10 (40 °C)
ebm-papst standard
Nominal voltage
cfm
Nominal data
Temperature range
Air flow
m3/h
Series RL 48
Nominal speed
Air flow
1) Fiberglass-reinforced plastic
Max.
61 m /h
DC centrifugal fans
3
97 x 93.5 x 33 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials):
Impeller: GRP1)
- Speed signal
Direction of air flow: Axial: Intake,
- Go / NoGo alarm
Centrifugal: Exhaust
- Alarm with speed limit
Connection:
via single wires AWG 26, TR 64
- External temperature sensor
Highlights:
Forward-curved impeller
- Internal temperature sensor
Weight:
170 g
- PWM control input
- Analog control input
- Moisture protection
– Material:
–
–
–
–
4 500
-20...+70
60 000 / 30 000
102 500
19.2
4 900
-20...+55
55 000 / 40 000
92 500
12...26.4
6.6
14.0
4 500
-20...+70
60 000 / 30 000
102 500
12...26.4
6.8
18.0
4 900
-20...+60
55 000 / 35 000
92 500
VDC
VDC
Bel(A)
RL 65-21/12
56
32,9
12
6.8...13.8
RL 65-21/12 H
61
35,8
12
6.8...13.2
RL 65-21/14
56
32,9
24
RL 65-21/14 H
61
35,8
24
Subject to change
Snap-in fins for
easy latch
Tin-pla
te
d
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
98
Curve
15.0
6.8
cfm
Life expectancy L10IPC
(40 °C) see page 17
Temperature range
6.6
m3/h
Service life L10 (Tmax)
ebm-papst standard
Nominal speed
Hours
Type
Nominal data
Service life L10 (40 °C)
ebm-papst standard
Power consumption
Hours
Sound power level
°C
Voltage range
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RL 65
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
¿
¡
¿
¡
55 m /h
Information
Max.
DC centrifugal fans
3
 121 x 37 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Base plate: Sheet steel
- Go / NoGo alarm
Direction of air flow: Axial: Intake,
- Alarm with speed limit
Centrifugal: Exhaust
- External temperature sensor
Connection:
via single wires AWG 22, TR 64
- Internal temperature sensor
Highlights:
Forward-curved impeller
- PWM control input
Weight:
420 g
- Analog control input
- Moisture protection
- Salt spray protection
- Degree of protection:IP 54 / IP 68
–
–
–
RL 90-18/12 N
40
23.5
12
7...15
RL 90-18/14 NG
40
23.5
24
RL 90-18/14 N
40
23.5
RL 90-18/18 NH
55
32.4
rpm-1
°C
Hours
Hours
5.8
6.3
2 500
-30...+75
62 500 / 27 500
105 000
12...28
5.8
5.6
2 500
-20...+75
62 500 / 27 500
105 000
24
12...28
5.8
5.6
2 500
-30...+75
62 500 / 27 500
105 000
48
36...53
6.9
14.7
3 500
-30...+65
32 500 / 17 500
55 000
Curve
Watts
DC fans - specials
/
¿
¿
¿
¡
ACmaxx / EC fans
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
cfm
Temperature range
Nominal voltage
m3/h
AC centrifugal fans
AC axial fans
Subject to change
37,3 + 0,7
Accessories
26,5
54
57,6
80
104,8 + 0,2
120,6
2
67,4 + 0,4
3,5
2,5
97
71,4 + 0,2
6+1
4,2 + 0,4
100,8
112,7 + 0,2
120,6
+ 0,2
15,5
30+_ 0,3
6+ 0,3
Tin-plated
12±0,5
*Federmutter
oder 8-32UNC.
Einschraubtiefe
max.12,5
Screw clip M4M4
or 8-32UNC.
Screw-in
depth max. 12.5
min. min.9,0
9.0
99
2016-01
Air performance measured according to:
ISO 5801.
Installation category A, without contact
protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m;
Sound pressure level LpA measured at 1 m
distance from fan axis.
The acoustic values are only valid for the
described measurement setup and may vary
depending on the installation situation.
In the event of deviation from the standard
configuration, the parameters must be checked
after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
310 +10
45
60,3
Representatives
Nominal data
Nominal speed
Air flow
Type
Series RL 90 N
Power consumption
Air flow
1) Fiberglass-reinforced plastic
DC centrifugal fans
–
DC axial fans
– Material:
Max.
80 m /h
DC centrifugal fans
3
 127 x 25 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Base plate: Sheet steel
- Go / NoGo alarm
Direction of air flow: Axial: Intake,
- Alarm with speed limit
Centrifugal: Exhaust
- External temperature sensor
Connection:
via single wires AWG 22, TR 64
- Internal temperature sensor
Highlights:
Optional protective cap for
- PWM control input
outlet opening
- Analog control input
Backward-curved impeller
- Moisture protection
Weight:
320 g
- Degree of protection: IP 54
– Material:
–
–
–
–
12
8...15
64
37.7
24
64
37.7
48
Air flow
64
RLF 100-11/14
RLF 100-11/18
Watts
rpm-1
°C
Hours
Hours
6.4
8.0
5 100
-20...+75
80 000 / 30 000
135 000
16...30
6.4
8.0
5 100
-20...+75
80 000 / 30 000
135 000
36...60
6.4
8.6
5 100
-20...+75
80 000 / 30 000
135 000
High speed models with open-collector tachometer and PWM speed control.
RLF 100-11/12/2 HP-200
80
47.1
12
10...13.2
7.5
18.6
6 400
-20...+60
72 500 / 45 000
122 500
RLF 100-11/18/2 HP-182
80
47.1
48
43...53
7.5
17.0
6 400
-20...+70
72 500 / 35 000
122 500
Subject to change
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
100
Tin-p
la
ted
Curve
37.7
RLF 100-11/12
Life expectancy L10IPC
(40 °C) see page 17
/
Service life L10 (Tmax)
ebm-papst standard
Sintec sleeve bearings
Ball bearings
Bel(A)
Service life L10 (40 °C)
ebm-papst standard
Sound power level
VDC
m3/h
Temperature range
Voltage range
VDC
Type
Nominal data
Nominal speed
Nominal voltage
cfm
Series RLF 100
Power consumption
Air flow
1) Fiberglass-reinforced plastic
¿
¿
¿
¡
¡
55 m /h
Information
Max.
DC centrifugal fans
3
 135 x 38 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Base plate: Sheet steel
- Go / NoGo alarm
Direction of air flow: Axial: Intake,
- Alarm with speed limit
Centrifugal: Exhaust
- External temperature sensor
Connection:
Via single wires AWG 22, TR 64
- Internal temperature sensor
48 V model: Flat plug
- PWM control input
6.3 x 0.8 mm for ground
- Analog control input
conductor
- Moisture protection
Highlights:
Forward-curved impeller
- Salt spray protection
Weight:
440 g
- Degree of protection: IP 54 / IP 68
–
–
–
32.4
12
7...15
RG 90-18/14 NG
55
32.4
24
RG 90-18/14 N
55
32.4
RG 90-18/18 N
55
32.4
°C
Hours
Hours
5.5
6.7
2 200
-30...+75
62 500 / 27 500
105 000
12...28
5.5
6.2
2 200
-10...+75
62 500 / 27 500
105 000
24
12...28
5.5
6.2
2 200
-30...+75
62 500 / 27 500
105 000
48
36...56
5.5
6.1
2 200
-30...+75
62 500 / 27 500
105 000
DC fans - specials
55
rpm-1
¿
¿
¿
¿
ACmaxx / EC fans
RG 90-18/12 N
Watts
Curve
/
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
Bel(A)
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
VDC
Tin-p
la
ted
101
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
AC centrifugal fans
AC axial fans
Subject to change
Representatives
Type
Temperature range
Nominal voltage
cfm
Nominal data
Nominal speed
Air flow
m3/h
Series RG 90 N
Power consumption
Air flow
1) Fiberglass-reinforced plastic
DC centrifugal fans
–
DC axial fans
– Material:
Max.
137 m /h
DC centrifugal fans
3
 180 x 40 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Base plate: Sheet steel
- Go / NoGo alarm
Direction of air flow: Axial: Intake,
- Alarm with speed limit
Centrifugal: Exhaust
- External temperature sensor
Connection:
Via single wires AWG 22, TR 64
- Internal temperature sensor
48 V model: Flat plug
- PWM control input
6.3 x 0.8 mm for ground
- Analog control input
conductor
- Moisture protection
Highlights:
Backward-curved impeller
- Salt spray protection
Weight:
730 g
- Degree of protection: IP 54 / IP 68
– Material:
–
–
–
–
1 750
-30...+75
70 000 / 30 000
117 500
5.2
2 550
-30...+75
62 500 / 27 500
105 000
12...28
4.8
2.0
1 750
-30...+75
70 000 / 30 000
117 500
12...28
5.8
4.9
2 550
-30...+75
62 500 / 27 500
105 000
48
36...56
5.8
4.8
2 550
-30...+75
62 500 / 27 500
105 000
48
36...56
7.0
19.0
4 000
-20...+70
55 000 / 27 500
92 500
VDC
VDC
Bel(A)
RG 125-19/12 NM
60.0
35.3
12
7...15
RG 125-19/12 N
87.5
51.5
12
7...15
RG 125-19/14 NM
60.0
35.3
24
RG 125-19/14 N
87.5
51.5
24
RG 125-19/18 N
87.5
51.5
RG 125-19/18 NH
137
80.6
Subject to change
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
102
Tin-p
la
ted
Curve
2.0
5.8
cfm
Life expectancy L10IPC
(40 °C) see page 17
Temperature range
4.8
m3/h
Service life L10 (Tmax)
ebm-papst standard
Nominal speed
Hours
Type
Nominal data
Service life L10 (40 °C)
ebm-papst standard
Power consumption
Hours
Sound power level
°C
Voltage range
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RG 125 N
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
¿
¡
¿
¡
¡
¬
Information
118 m /h
DC centrifugal fans
3
Max.
 180 x 40 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Base plate: Sheet steel
- Go / No-go alarm
Direction of air flow: Axial: Intake,
- Alarm with speed limit
Centrifugal: Exhaust
- External temperature sensor
Connection:
via single wires AWG 22, TR 64
- PWM control input
Highlights:
Backward-curved impeller
- Analog control input
3-phase fan drive with special
- Multi-option control input
commutation electronics for
- Moisture protection
extremely low-noise operation
- Salt spray protection
Weight:
750 g
- Degree of protection: IP 54
–
–
–
DC centrifugal fans
–
DC axial fans
– Material:
118
69.4
24
20.4...27.6
6.0
Watts
rpm-1
°C
Hours
Hours
9.3
2 500
-20...+70
62 500 / 32 500
105 000
DC fans - specials
RG 140-22/14 N/2 TDPU
¿
Subject to change








n
rpm-1
Ped
W
LwA
dB(A)
2504
2504
2504
2504
9
9
9
9
61
61
62
64
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
Higher performance levels on request.
10
20
20
30
40
40
60
50
80
60
100
cfm
Accessories
Tin-p
la
ted
103
Representatives
0
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01
0,4
50
0,3
100
0,2
0,5
150
0,6
0,7
200
0,1
NEW
/
Curve
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
cfm
Temperature range
Nominal voltage
m3/h
Nominal speed
Air flow
Type
Nominal data
Power consumption
Air flow
Series RG 140 NTD
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
Max.
209 m /h
DC centrifugal fans
3
 220 x 56 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Base plate: Sheet steel
- Go / NoGo alarm
Direction of air flow: Axial: Intake,
- Alarm with speed limit
Centrifugal: Exhaust
- External temperature sensor
Connection:
Via single wires AWG 22, TR 64
- Internal temperature sensor
48 V model: Flat plug
- PWM control input
6.3 x 0.8 mm for ground
- Analog control input
conductor
- Moisture protection
Highlights:
Backward-curved impeller
- Salt spray protection
Weight:
1.4 kg
- Degree of protection: IP 54
– Material:
–
–
–
–
Bel(A)
/
Watts
rpm-1
°C
Hours
Hours
RG 160-28/12 NM
139
81
12
7...14
5.6
7.5
1 900
-20...+70
80 000 / 40 000
135 000
RG 160-28/12 N
209
123
12
7.5...14
6.6
21.0
2 850
-20...+70
70 000 / 35 000
117 500
RG 160-28/14 NM
139
81
24
12...28
5.6
7.0
1 900
-20...+70
80 000 / 40 000
135 000
RG 160-28/14 N
209
123
24
12...28
6.6
20.0
2 850
-20...+70
70 000 / 35 000
117 500
RG 160-28/18 N
209
123
48
28...60
6.6
20.0
2 850
-20...+70
70 000 / 35 000
117 500
Subject to change
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
104
Tin-p
la
ted
Curve
VDC
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
cfm
Service life L10 (40 °C)
ebm-papst standard
Voltage range
Type
Temperature range
Nominal voltage
Nominal data
Nominal speed
Air flow
m3/h
Series RG 160 N
Power consumption
Air flow
1) Fiberglass-reinforced plastic
¿
¡
¿
¡
¡
444 m /h
Information
Max.
DC centrifugal fans
3
 220 x 56 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Base plate: Sheet steel
- Go / NoGo alarm
Direction of air flow: Axial: Intake,
- Alarm with speed limit
Centrifugal: Exhaust
- External temperature sensor
Connection:
Via single wires AWG 22, TR 64
- Internal temperature sensor
48 V model: Flat plug
- PWM control input
6.3 x 0.8 mm for ground
- Analog control input
conductor
- Humidity protection
Highlights:
Smoothly operating 3-phase
- Degree of protection: IP 54
fan drive
Backward-curved impeller
Weight:
1.4 kg
–
–
–
DC centrifugal fans
–
DC axial fans
– Material:
Watts
24
16...28
34.7
181
RG 160-28/14 NTD
308
181
24
RG 160-28/14 NTDH
370
218
RG 160-28/18 NTD...
RG 160-28/18 N/2 TDHHP*
59
34.7
308
181
444
261
°C
Hours
Hours
-20...+60
55 000 / 35 000
92 500
—
2.0
800
7.5
64
4 200
16...28
7.5
64
4 200
-20...+60
55 000 / 35 000
92 500
24
16...28
7.8
101
5 000
-20...+60
50 000 / 32 500
85 000
48
38...57
-20...+70
55 000 / 27 500
92 500
48
36...60
-20...+65
40 000 / 22 500
67 500
—
2.0
800
7.5
59
4 200
8.5
159
6 000
¿
¡
¡
¬
¿
¡
√
Subject to change
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
AC centrifugal fans
AC axial fans
Models RG 160-28/14 NTD... and RG 160-28/18 NTD... are available in customer-specific, custom-developed variants only.
The figures indicated are technically feasible benchmark values.
The fans can be specially adapted to your application with signal outputs and control inputs.
*The specific service life is valid when an external capacitor is wired between the positive and negative wires.
Please note the wiring suggestion.
Tin-p
la
ted
105
Representatives
59
308
RG 160-28/14 NTD...
rpm-1
DC fans - specials
/
ACmaxx / EC fans
Bel(A)
Curve
Power consumption
VDC
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
Air flow
m3/h
2016-01
Min.
Max.
Type
Service life L10 (40 °C)
ebm-papst standard
Voltage range
Min.
Max.
Nominal data
Temperature range
Nominal voltage
cfm
Series RG 160 NTD
Nominal speed
Air flow
1) Fiberglass-reinforced plastic
Max.
930 m /h
DC centrifugal fans
3
 226 x 85 mm
– Possible special versions:
Scroll housing: GRP1)
(See chapter DC fans - specials)
Impeller: GRP1)
- Speed signal
Direction of air flow: Axial: Intake,
- Go / NoGo alarm
Centrifugal: Exhaust
- Alarm with speed limit
Direction of rotation: Clockwise, looking towards rotor
- External temperature sensor
Connection:
via single wires AWG 18, 20 or
- Internal temperature sensor
AWG 22, TR 64. Speed signal
- PWM control input
and control input AWG 22
- Analog control input
Highlights:
Highly efficient and smoothly
- Multi-option control input
operating 3-phase fan drive
- Moisture protection
Backward-curved RadiCal
- Salt spray protection
impeller
- Degree of protection: IP 54
Weight:
1210 g
– Material:
–
–
–
–
–
Bel(A)
/
RG 190-39/14/2 TDMLO
630
371
24
16...30
7.6
54
3 000
-20...+60
55 000 / 35 000
92 500
RG 190-39/14/2 TDMO
820
482
24
16...36
7.9
113
3 900
-20...+65
52 500 / 30 000
87 500
RG 190-39/18/2 TDMLO*
630
371
48
36...57
7.6
52
3 000
-20...+65
55 000 / 30 000
92 500
RG 190-39/18/2 TDMO
820
482
48
36...72
7.9
113
3 900
-20...+65
52 500 / 30 000
87 500
RG 190-39/18/2 TDO
930
547
48
36...72
8.3
140
4 400
-20...+65
40 000 / 22 500
67 500
Watts
°C
Hours
Curve
rpm-1
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
cfm
Temperature range
Nominal voltage
m3/h
Nominal data
Nominal speed
Air flow
Type
Series RG 190 TD
Power consumption
Air flow
1) Fiberglass-reinforced plastic
Hours
¿
¡
¿
¡
¬
Subject to change
* On request
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM,
Standstill if control cable is interrupted.
Tin-plated
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
106
Finger guards
P. 249
Information
1100 m /h
DC centrifugal fans – RadiCal
3
 270 x 99 mm
–
–
–
–
–
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Salt spray protection
- Degree of protection:IP 54
DC axial fans
Scroll housing: GRP1)
Impeller: GRP1)
Direction of air flow: Axial: Intake,
Centrifugal: Exhaust
Direction of rotation: Clockwise,
looking towards rotor
Connection:
via single wires AWG 18, 20 or
AWG 22, TR 64. Speed signal
and control input AWG 22
Highlights:
Highly efficient and smoothly
operating 3-phase fan drive
Backward-curved impeller
Weight:
1560 g
– Material:
DC centrifugal fans
Max.
-20...+55
55 000 / 40 000
92 500
7.5
101
3 000
-20...+55
55 000 / 40 000
92 500
VDC
Bel(A)
RG 220-43/14/2 TDMO
1100
647
24
16...36
RG 220-43/18/2 TDMO*
1100
647
48
36...72
DC fans - specials
3 000
VDC
Curve
101
cfm
Life expectancy L10IPC
(40 °C) see page 17
Temperature range
7.5
m3/h
Service life L10 (Tmax)
ebm-papst standard
Nominal speed
Hours
Type
Nominal data
Service life L10 (40 °C)
ebm-papst standard
Power consumption
Hours
Sound power level
°C
Voltage range
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RG 220 TD
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
¿
¿
Subject to change
AC centrifugal fans
2
Tin-plated
1,75
500
in H O
Pa
AC axial fans
ACmaxx / EC fans
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM.
Standstill at 0% PWM, Standstill if control cable is interrupted.
Further types available on request.
* On request
0
100
200
200
400
300
400
600
500
800
600
cfm
1000
m3/h
Finger guards
P. 249
Accessories
107
Representatives
0,25
100
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
2016-01
0,5
200
0,75
1,0
300
1,25
1,5
400
Max.
1450 m /h
DC centrifugal fans – RadiCal
3
 270 x 119 mm
–
Scroll housing: GRP1)
Impeller: GRP1)
Direction of air flow: Axial: Intake, Centrifugal: Exhaust
Direction of rotation: Clockwise, looking towards rotor
Connection:
via single wires AWG 18, 20 or
AWG 22, TR 64. Speed signal
and control input AWG 22
Highlights:
Highly efficient and smoothly
operating 3-phase fan drive
Backward-curved RadiCal
impeller
Weight:
1750 g
Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Humidity protection
- Salt spray protection
- Degree of protection: IP 54
– Material:
–
–
–
–
–
/
1090
641
24
16...36
RG 225-55/18/2 TDMLO* 1090
641
48
RG 225-55/18/2 TDMO
1210
712
RG 225-55/18/2 TDO
1450
853
RG 225-55/14/2 TDMLO
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
Bel(A)
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
VDC
Type
Watts
rpm-1
°C
Hours
Hours
7.4
80
2 500
-20...+65
52 500 / 30 000
87 500
36...72
7.4
80
2 500
-20...+65
52 500 / 30 000
87 500
48
36...72
7.9
116
2 800
-20...+55
55 000 / 40 000
92 500
48
36...60
8.1
192
3 300
-20...+40
30 000 / 30 000
50 000
Curve
Temperature range
Nominal voltage
cfm
Nominal data
Nominal speed
Air flow
m3/h
Series RG 225 TD
Power consumption
Air flow
1) Fiberglass-reinforced plastic
¿
¿
¡
¬
Subject to change
* On request
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM,
Standstill if control cable is interrupted.
The specific service life is valid when an external capacitor is wired between the positive and negative wires.
Please note the wiring suggestion.
Tin-plated
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
108
Finger guards
P. 249
220 m /h
Information
Max.
DC centrifugal fans
3
Ø 97 x 41 mm
RET 97-25/14/2 TDP
220
129
24
16...32
RET 97-25/18/2 TDP
220
129
48
36...60
°C
DC axial fans
DC centrifugal fans
Bel(A)
Hours
Hours
-20...+60
80 000 / 50 000
135 000
-20...+60
80 000 / 50 000
135 000
DC fans - specials
VDC
Curve
6 000
VDC
Life expectancy L10IPC
(40 °C) see page 17
76
cfm
Service life L10 (Tmax)
ebm-papst standard
8.1
m3/h
Service life L10 (40 °C)
ebm-papst standard
Nominal speed
6 000
Type
Nominal data
Temperature range
Power consumption
77
Sound power level
8.1
Voltage range
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RET 97 TD
Sintec sleeve bearings
Ball bearings
– Material:
Impeller: Galvanized sheet steel – Possible special versions:
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
via single wires AWG 18, 20 or
- Internal temperature sensor
AWG 22, TR 64. Speed signal
- PWM control input
and control input AWG 22
- Analog control input
– Highlights:
Highly efficient and smoothly
- Moisture protection
operating 3-phase fan drive
Forward-curved impeller
Fan requires a scroll housing
– Weight:
430 g
¿
¿
Subject to change
+1
Accessories
97
ø 58,3
7,95 + 1
109
Representatives
40,5
2016-01
Inlet rings
from p. 252
24,4
M4 (4x)
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst scroll housing
without contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level LpA measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parametersmust be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
ø 47,1
310 +10
6 +1
Tin-plated
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM.
Standstill at 0% PWM, maximum speed if control cable is interrupted.
To attain the specified service life, an external capacitor must be wired
between the positive and negative wires. Please note the wiring suggestion.
Max.
104 m /h
DC centrifugal fans
3
Ø 104 x 25 mm
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
via single wires AWG 22, TR 64
- Internal temperature sensor
– Highlights:
Backward-curved impeller
- PWM control input
– Weight:
160 g
- Analog control input
- Moisture protection
- Degree of protection: IP 54
/
REF 100-11/12
86
50.6
12
8...15
REF 100-11/14
86
50.6
24
REF 100-11/18
REF 100-11/18 H
Watts
rpm-1
°C
Hours
Hours
6.3
7.5
5 400
-20...+75
80 000 / 30 000
135 000
16...30
6.3
7.5
5 400
-20...+75
80 000 / 30 000
135 000
86
50.6
48
36...60
6.3
8.2
5 400
-20...+75
80 000 / 30 000
135 000
104
61.2
48
36...56
6.9
14.8
6 700
-20...+70
67 500 / 32 500
115 000
Subject to change
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
127 x 127 mm.
Cover plate 127 x 127 mm, with an air inlet opening
Ø 70 mm, arranged concentrically to the impeller.
2016-01
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m;
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
110
ted
6 deep
Tin-pla
Curve
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
VDC
Service life L10 (Tmax)
ebm-papst standard
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (40 °C)
ebm-papst standard
Sound power level
m3/h
Temperature range
Voltage range
Air flow
Type
Nominal data
Nominal speed
Nominal voltage
cfm
Series REF 100
Power consumption
Air flow
1) Fiberglass-reinforced plastic
¿
¿
¿
¡
Information
190 m /h
DC centrifugal fans
3
Ø 101 x 52 mm
DC centrifugal fans
DC axial fans
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
via single wires AWG 22, TR 64
- Internal temperature sensor
– Highlights:
Backward-curved impeller
- PWM control input
– Weight:
305 g
- Analog control input
- Moisture protection
7.2
48
36...60
7.2
RER 101-36/12 NH
162
95
12
9...13.6
RER 101-36/12 NHH
190
112
12
RER 101-36/14 NHH
190
112
RER 101-36/18 NHH
190
112
°C
Hours
Hours
-20...+70
65 000 / 32 500
110 000
6 000
-20...+70
60 000 / 30 000
102 500
22.5
6 050
-20...+70
60 000 / 30 000
102 500
19.4
5 850
-20...+70
60 000 / 30 000
102 500
DC fans - specials
18...27.2
Bel(A)
¡
¿
¿
¿
ACmaxx / EC fans
24
VDC
Curve
20.5
VDC
Life expectancy L10IPC
(40 °C) see page 17
7.2
cfm
Service life L10 (Tmax)
ebm-papst standard
9...13.6
m3/h
Service life L10 (40 °C)
ebm-papst standard
Nominal speed
5 000
Type
Nominal data
Temperature range
Power consumption
13.0
Sound power level
6.9
Voltage range
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RER 101 N
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
Subject to change
Accessories
36,7
6,0 +- 0,2
7,0 +- 0,45
8,0 +- 0,55
50,25 +- 0,95
51,7 +- 0,9
111
2016-01
10 deep
O 100 +- 0,5
O 60 +- 0,2
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m;
Sound pressure level LpA measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
ted
M 4 (3x)
Tin-p
la
AC centrifugal fans
AC axial fans
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
148 x 148 mm.
Cover plate 148 x 148 mm, with an air inlet
opening Ø 66 mm, arranged concentrically to the
impeller.
Representatives
Max.
Max.
390 m /h
DC centrifugal fans
3
Ø 120 x 54 mm
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
via single wires AWG 18, 20 or
- Internal temperature sensor
AWG 22, TR 64. Speed signal
- PWM control input
and control input AWG 22
- Analog control input
– Highlights:
Highly efficient and smoothly
- Moisture protection
operating 3-phase fan drive
Backward-curved impeller
– Weight:
430 g
/
Watts
rpm-1
°C
Hours
Hours
RER 120-26/14/2 TDMP*
320
188
24
16...32
tbd
51
5 200
-20...+60
60 000 / 37 500
102 500
RER 120-26/14/2 TDP
377
222
24
16...32
8.2
78
6 100
-20...+60
55 000 / 35 000
92 500
RER 120-26/18/2 TDMP*
320
188
48
36...60
tbd
51
5 200
-20...+60
57 500 / 35 000
97 500
RER 120-26/18/2 TDP
390
230
48
36...60
8.3
92
6 300
-20...+60
50 000 / 30 000
85 000
Curve
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
cfm
Temperature range
Nominal voltage
m3/h
Nominal data
Nominal speed
Air flow
Type
Series RER 120 TD
Power consumption
Air flow
1) Fiberglass-reinforced plastic
¿
¡
¿
¬
Subject to change
* On request
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM,
maximum speed if control cable is interrupted.
The specific service life is valid when an external capacitor is wired between the positive and negative wires.
Please note the wiring suggestion.
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded under
the following measurement parameters:
Centrifugal fan mounted on a foundation plate
140 x 140 mm.
Cover plate 140 x 140 mm, with an air inlet opening
Ø 94.4 mm, arranged concentrically to the impeller.
2016-01
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m;
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
112
Inlet rings
from p. 252
Max. 8 deep
Tin-plated
Representatives
2016-01
113
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
DC axial fans
Information
Max.
250 m /h
DC centrifugal fans
3
Ø 120 mm
– Material:
Power consumption
Input current
Sound pressure level
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
°C
R1G 120
M1G 045-BE
A
24
16-28
250
4060
26
1.20
62
-25..+50
p. 259 / G)
R1G 120
M1G 045-BE
A
48
36-57
250
4060
26
0.60
62
-25..+50
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
–
Impeller: PA 6.6 plastic, fiberglass-reinforced
Rotor: Galvanized
Number of blades:
9
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 20
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
4520
36
65
—
A
2’
4500
36
64
27
A
3’
4540
36
61
45
A
4’
4750
32
64
39
A
1
4060
26
62
—
A
2
4000
26
61
27
A
3
4050
26
58
45
A
4
4200
23
61
39
A
5
3270
14
56
—
A
6
3250
14
55
27
A
7
3280
14
53
45
A
8
3400
13
56
39
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the
specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
114
n
rpm-1
Information
DC axial fans
See connection diagram p. 259
Axial
EN 60950-1
EAC
DC centrifugal fans
Technical features:
Cable exit:
Conformity with standard(s):
Approvals:
kg
Inlet ring
(long)
R1G 120-AD13 -02
0.5
96120-2-4013
R1G 120-AD11 -02
0.5
96120-2-4013
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal fans
AC axial fans
Clearance for screw
max. 4 mm
Inlet rings
from p. 253
Connection diagrams
P. 259
115
2016-01
Accessories
AC centrifugal fans
Wire end splices
Representatives
–
–
–
–
Max.
166 m /h
DC centrifugal fans
3
Ø 138 x 35 mm
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
via single wires AWG 22, TR 64
- Internal temperature sensor
– Highlights:
Backward-curved impeller
- PWM control input
– Weight:
320 g
- Analog control input
- Moisture protection
- Salt spray protection
- Degree of protection: IP 54 / IP 68
24
12...28
7.0
48
36...56
5.7
VDC
Bel(A)
RER 125-19/12 N
110
64.7
12
7...15
RER 125-19/14 N
110
64.7
24
RER 125-19/14 NH
166
97.7
RER 125-19/18 N
110
64.7
°C
Curve
4.3
VDC
Life expectancy L10IPC
(40 °C) see page 17
5.7
cfm
Service life L10 (Tmax)
ebm-papst standard
12...28
m3/h
Service life L10 (40 °C)
ebm-papst standard
Nominal speed
2 650
Type
Nominal data
Temperature range
Power consumption
4.6
Sound power level
5.7
Voltage range
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RER 125 N
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
Hours
Hours
-30...+75
62 500 / 27 500
105 000
2 650
-30...+75
62 500 / 27 500
105 000
13.0
4 000
-20...+70
55 000 / 27 500
92 500
4.2
2 650
-30...+75
62 500 / 27 500
105 000
Subject to change
5 deep
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
220 x 220 mm.
Cover plate 220 x 220 mm, with an air inlet opening
Ø 86 mm, arranged concentrically to the impeller.
2016-01
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m;
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
116
Tin-plated
¿
¿
¡
¿
Information
565 m /h
DC centrifugal fans
3
Ø 133 x 91 mm
DC centrifugal fans
DC axial fans
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
via single wires AWG 18, 20 or
- Internal temperature sensor
AWG 22, TR 64. Speed signal
- PWM control input
and control input AWG 22
- Analog control input
– Highlights:
Highly efficient and smoothly
- Multi-option control input
operating 3-phase fan drive
- Moisture protection
Backward-curved impeller
- Salt spray protection
– Weight:
890 g
- Degree of protection: IP 54
460
271
24
16...30
RER 133-41/14/2 TDP*
565
332
24
16...36
RER 133-41/18/2 TDMP* 460
271
48
RER 133-41/18/2 TDP
332
48
565
rpm-1
°C
Hours
Hours
tbd
58
5 000
-20...+65
72 500 / 40 000
122 500
tbd
90
6 000
-20...+65
70 000 / 37 500
117 500
36...57
tbd
50
5 000
-20...+65
72 500 / 40 000
122 500
36...72
8.2
87
6 000
-20...+65
70 000 / 37 500
117 500
DC fans - specials
RER 133-41/14/2 TDMP
Watts
¿
¡
¿
¡
ACmaxx / EC fans
/
Curve
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
cfm
Temperature range
Nominal voltage
m3/h
Nominal data
Nominal speed
Air flow
Type
Series RER 133 TD
Power consumption
Air flow
1) Fiberglass-reinforced plastic
Subject to change
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM.
Standstill at 0% PWM, maximum speed if control cable is interrupted.
AC centrifugal fans
AC axial fans
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
140 x 140 mm.
Cover plate 140 x 140 mm, with an air inlet opening
Ø 87 mm, arranged concentrically to the impeller.
Inlet rings
from p. 252
117
2016-01
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring
without contact protection.
Noise: Total sound power level LWA
ISO 103002 measured on a hemisphere with
a distance of 2 m;
Sound pressure level LpA measured at 1 m
distance from fan axis.
The values given are applicable only under the
specified measuring conditions and may differ
depending on the installation conditions.
In the event of deviation from the standard
configuration, the parameters must be checked
after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
Tin-plated
Max. 8 deep
* On request
Representatives
Max.
Max.
255 m /h
DC centrifugal fans
3
Ø 165 x 51 mm
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Counterclockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
via single wires AWG 22, TR 64
- Internal temperature sensor
– Highlights:
Backward-curved impeller
- PWM control input
– Weight:
590 g
- Analog control input
- Moisture protection
- Salt spray protection
- Degree of protection: IP 54
28...60
6.4
19.0
VDC
Bel(A)
RER 160-28/12 N
255
150
12
7...14
RER 160-28/14 N
255
150
24
RER 160-28/18 N
255
150
48
°C
Hours
Hours
-20...+70
75 000 / 37 500
127 500
3 000
-20...+70
75 000 / 37 500
127 500
3 000
-20...+70
75 000 / 37 500
127 500
Curve
19.0
VDC
Life expectancy L10IPC
(40 °C) see page 17
6.4
cfm
Service life L10 (Tmax)
ebm-papst standard
12...28
m3/h
Service life L10 (40 °C)
ebm-papst standard
Nominal speed
3 000
Type
Nominal data
Temperature range
Power consumption
19.0
Sound power level
6.4
Voltage range
rpm-1
Nominal voltage
Watts
Air flow
/
Air flow
Series RER 160 N
Sintec sleeve bearings
Ball bearings
1) Fiberglass-reinforced plastic
¿
¿
¿
Subject to change
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
260 x 260 mm.
Cover plate 260 x 260 mm, with an air inlet opening
Ø 100 mm, arranged concentrically to the impeller.
2016-01
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m;
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
118
Inlet rings
from p. 252
Max. 8 deep
Tin-plated
360 m /h
Information
Max.
DC centrifugal fans
3
Ø 165 x 51 mm
DC centrifugal fans
DC axial fans
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
via single wires AWG 22, TR 64
- Internal temperature sensor
– Highlights:
Highly efficient and smoothly
- PWM control input
operating 3-phase fan drive
- Analog control input
Backward-curved impeller
- Humidity protection
– Weight:
590 g
- Degree of protection: IP 54
RER 160-28/14 NTD…
360
211
24
16...28
RER 160-28/18 NTD…
360
211
48
38...57
Watts
rpm-1
°C
Hours
7.4
51
4 200
-20...+60
55 000 / 27 500
92 500
7.4
48
4 200
-20...+70
55 000 / 27 500
92 500
Hours
DC fans - specials
/
Curve
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
cfm
Temperature range
Nominal voltage
m3/h
Nominal data
Nominal speed
Air flow
Type
Series RER 160 NTD
Power consumption
Air flow
1) Fiberglass-reinforced plastic
¡
¿
Subject to change
ACmaxx / EC fans
Model RER 160-28/18 NTD... is available in customer-specific, custom-developed variant only.
The figures indicated are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs
and control inputs.
* The specific service life is valid when an external capacitor is wired between the positive and negative wires.
Please note the wiring suggestion.
AC centrifugal fans
AC axial fans
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
260 x 260 mm.
Cover plate 260 x 260 mm, with an air inlet opening
Ø 100 mm, arranged concentrically to the impeller.
Representatives
119
2016-01
Inlet rings
from p. 252
Max. 8 deep
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m;
Sound pressure level LpA measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
Tin-plated
Max.
800 m /h
DC centrifugal fans
3
Ø 175 x 55 mm
REF 175-30/18/2 TDP
800
470
48
36 ... 72
8.3
/
Watts
rpm-1
144
4 400
°C
-20...+60
Hours
Hours
65 000 / 37 500
110 000
Curve
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
cfm
Temperature range
Nominal voltage
m3/h
Nominal speed
Air flow
Type
Nominal data
Power consumption
Air flow
Series RER 175 TD
Sintec sleeve bearings
Ball bearings
– Material:
Impeller: Galvanized sheet steel – Possible special versions:
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
via single wires AWG 18, 20 or
- Internal temperature sensor
AWG 22, TR 64. Speed signal
- PWM control input
and control input AWG 22
- Analog control input
– Highlights:
Highly efficient and smoothly
- Multi-option control input
operating 3-phase fan drive
- Humidity protection
Backward-curved impeller
- Degree of protection: IP 54
– Weight:
930 g
¿
Subject to change
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM.
Standstill at 0% PWM, maximum speed if control cable is interrupted.
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
180 x 180 mm.
Cover plate 180 x 180 mm, with an air inlet opening
Ø 125.5 mm, arranged concentrically to the impeller.
2016-01
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m;
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
120
Inlet rings
from p. 252
Max. 8 deep
Tin-plated
Information
980 m /h
DC centrifugal fans
3
Ø 175 x 69 mm
DC centrifugal fans
DC axial fans
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
Via single wires AWG 18, 20 or
- Internal temperature sensor
AWG 22, TR 64, speed signal
- PWM control input
and control input AWG 22
- Analog control input
– Highlights:
Highly efficient and smoothly
- Multi-option control input
operating 3-phase fan drive
- Moisture protection
Backward-curved impeller
- Salt spray protection
– Weight:
775 g
- Degree of protection: IP 54
RER 175-42/14/2 TDMLP
600
353
24
16...30
RER 175-42/14/2 TDMP
865
509
24
16...36
RER 175-42/18/2 TDMLP
600
353
48
RER 175-42/18/2 TDMP*
865
509
RER 175-42/18/2 TDP
980
577
rpm-1
°C
Hours
Hours
7.3
48
3 400
-20...+65
72 500 / 40 000
122 500
8.2
110
4 800
-20...+65
70 000 / 40 000
117 500
36...57
7.3
46
3 400
-20...+65
72 500 / 40 000
122 500
48
36...72
8.2
110
4 800
-20...+65
70 000 / 40 000
117 500
48
36...72
8.5
166
5 400
-20...+65
60 000 / 32 500
102 500
Curve
Watts
DC fans - specials
/
¿
¡
¿
¡
¬
ACmaxx / EC fans
Bel(A)
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
VDC
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
cfm
Temperature range
Nominal voltage
m3/h
Nominal data
Nominal speed
Air flow
Type
Series RER 175 TD
Power consumption
Air flow
1) Fiberglass-reinforced plastic
Subject to change
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM.
Standstill at 0% PWM, maximum speed if control cable is interrupted.
Max. 8 deep
M4 (4x)
6,8+ 0,8
42
69 ±1
121
2016-01
Inlet rings
from p. 252
ø58 + 0,1
ø 72 +0,3
ø175 +0,5
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002
measured on a hemisphere with a distance of 2 m;
Sound pressure level LpA measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
425 +10
Tin-plated
AC centrifugal fans
AC axial fans
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
180 x 180 mm.
Cover plate 180 x 180 mm, with an air inlet opening
Ø 125.5 mm, arranged concentrically to the impeller.
6 +1
* On request
Representatives
Max.
Max.
970 m /h
DC centrifugal fans – RadiCal
3
Ø 190 x 69 mm
– Material:
Impeller: GRP1)
– Direction of air flow: Axial: Intake,
Centrifugal: Exhaust
– Direction of rotation: Clockwise,
looking towards rotor
– Connection:
Via single wires AWG 18, 20 or
AWG 22, TR 64, speed signal
and control input AWG 22
– Highlights:
Highly efficient and smoothly
operating 3-phase fan drive
Backward-curved RadiCal
impeller
– Weight:
870 g
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Multi-option control input
- Moisture protection
- Salt spray protection
- Degree of protection: IP 54
Sound power level
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
VDC
VDC
Bel(A)
/
Watts
rpm-1
RER 190-39/14/2 TDMLO
650
382
24
16...30
7.6
58
3 000
-20...+60
55 000 / 35 000
92 500
RER 190-39/14/2 TDMO
860
506
24
16...36
7.9
110
3 900
-20...+65
52 500 / 30 000
87 500
RER 190-39/18/2 TDMLO*
650
382
48
36...57
7.6
56
3 000
-20...+65
55 000 / 30 000
92 500
RER 190-39/18/2 TDMO*
860
506
48
36...72
7.9
105
3 900
-20...+65
52 500 / 30 000
87 500
RER 190-39/18/2 TDO
970
571
48
36...72
8.3
148
4 400
-20...+65
40 000 / 22 500
67 500
°C
Hours
Curve
Life expectancy L10IPC
(40 °C) see page 17
Voltage range
cfm
Service life L10 (Tmax)
ebm-papst standard
Nominal voltage
m3/h
Nominal data
Service life L10 (40 °C)
ebm-papst standard
Air flow
Type
Series RER 190 TD
Temperature range
Air flow
1) Fiberglass-reinforced plastic
Hours
¿
¡
¿
¡
¬
Subject to change
* On request
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM.
Standstill at 0% PWM, Standstill if control cable is interrupted.
2016-01
122
Inlet rings
from p. 252
39
69 +1
6,5 +1
190 + 0,3
72 +0,3
Max. 8 deep
58 + 0,1
M4 (4x)
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA
ISO 103002 measured on a hemisphere with a distance
of 2 m;
Sound pressure level LpA measured at 1 m distance
from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
425 +10
Tin-plated
6 +1
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
195 x 195 mm.
Cover plate 195 x 195 mm, with an air inlet opening
Ø 125.5 mm, arranged concentrically to the impeller.
Representatives
2016-01
123
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
DC axial fans
Information
Max.
930 m /h
DC centrifugal fans – RadiCal
3
Ø 190 mm
– Material:
Power consumption
Input current
Sound pressure level
Admissible amb. temp.
Type
Motor
m3/h
rpm-1
W
A
dB(A)
°C
R3G 190
M3G 074-CF
A
24
16-28
880
4570
180
7.50
76
-25..+60
p. 262 / J5)
R3G 190
M3G 074-CF
B
48
36-57
930
4800
192
4.00
76
-25..+60
p. 262 / J5)
Technical features and
connection diagram
Nominal speed
VDC
Curve
Nominal data
Nominal voltage range
VDC
Nominal voltage
Air flow
–
–
–
–
–
–
–
–
Impeller: PA plastic
Rotor: Painted black
Number of blades:
7
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 44, depending on installation and position
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
n
rpm-1
Ped
W
I
A
L WA
dB(A)
B
A
A
1
4570
180
7.50
84
A
2
4525
188
7.83
79
A
3
4435
199
8.34
77
A
4
4520
191
7.96
81
B
1
4800
192
4.00
84
B
2
4690
212
4.41
80
B
3
4640
221
4.60
79
B
4
4740
205
4.28
81
2016-01
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the
specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
124
Information
DC axial fans
See connection diagram p. 262
Variable
EN 60950-1
EAC
DC centrifugal fans
Technical features:
Cable exit:
Conformity with standard(s):
Approvals:
kg
Inlet ring
R3G 190-RN38 -01
1.9
09576-2-4013
R3G 190-RN99 -02
1.9
09576-2-4013
Clearance for screw
max. 12 - 14 mm
Accessories
AC centrifugal fans
AC axial fans
Accessory part: Inlet ring 09576-2-4013
not included in the standard scope of delivery
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal fans
–
–
–
–
Connection diagrams
P. 262
125
Representatives
Inlet rings
P. 254
2016-01
PVC AWG 16 cable,
4 x crimped ferrules
Max.
1215 m /h
DC centrifugal fans – RadiCal
3
Ø 220 mm
– Material:
Power consumption
Input current
Sound pressure level
Admissible amb. temp.
Type
Motor
m3/h
rpm-1
W
A
dB(A)
°C
R3G 220
M3G 074-CF
A
24
16-28
1200
3460
157
6.50
73
-25...+60
p. 262 / J5)
R3G 220
M3G 074-CF
B
48
36-57
1215
3510
160
3.40
73
-25...+60
p. 262 / J5)
Technical features and
connection diagram
Nominal speed
VDC
Curve
Nominal data
Nominal voltage range
VDC
Nominal voltage
Air flow
–
–
–
–
–
–
–
–
Impeller: PA plastic
Rotor: Painted black
Number of blades:
7
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 44, depending on installation and position
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
B
A
2016-01
Ped
W
I
A
L WA
dB(A)
A
1
3460
157
6.50
81
A
2
3420
171
7.11
77
A
3
3360
182
7.59
74
A
4
3455
168
6.97
79
B
1
3510
160
3.40
81
B
2
3450
168
3.50
77
B
3
3385
178
3.71
74
B
4
3460
167
3.47
79
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the
specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
126
n
rpm-1
Information
DC axial fans
See connection diagram p. 262
Variable
EN 60950-1
EAC
DC centrifugal fans
Technical features:
Cable exit:
Conformity with standard(s):
Approvals:
kg
Inlet ring
R3G 220-RN12 -01
1.9
09609-2-4013
R3G 220-RNB6 -02
1.9
09609-2-4013
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal fans
–
–
–
–
Accessory part: Inlet ring 09609-2-4013
not included in the standard scope of delivery
Accessories
AC centrifugal fans
AC axial fans
Clearance for screw
max. 12 - 14 mm
Connection diagrams
P. 262
127
Representatives
Inlet rings
from p. 253
2016-01
PVC AWG 16 cable,
4 x crimped ferrules
Max.
1250 m /h
DC centrifugal fans – RadiCal
3
Ø 221 x 71 mm
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
Via single wires AWG 18, 20 or
- Internal temperature sensor
AWG 22, TR 64, speed signal
- PWM control input
and control input AWG 22
- Analog control input
– Highlights:
Highly efficient and smoothly
- Multi-option control input
operating 3-phase fan drive
- Humidity protection
Backward-curved impeller
- Salt spray protection
– Weight:
940 g
- Degree of protection: IP 54
RER 220-43/14/2 TDMO* 1063
625
24
16...36
RER 220-43/18/2 TDMO
1063
625
48
RER 220-43/18/2 TDO
1250
735
48
Subject to change
* On request
Watts
rpm-1
°C
Hours
Hours
tbd
110
3 000
-20...+55
65 000 / 45 000
110 000
36...72
tbd
110
3 000
-20...+55
65 000 / 45 000
110 000
36...72
tbd
160
3 500
-20...+55
60 000 / 42 500
102 500
Curve
/
Life expectancy L10IPC
(40 °C) see page 17
Sintec sleeve bearings
Ball bearings
Bel(A)
Service life L10 (Tmax)
ebm-papst standard
Sound power level
VDC
Service life L10 (40 °C)
ebm-papst standard
Voltage range
VDC
Type
Temperature range
Nominal voltage
cfm
Nominal data
Nominal speed
Air flow
m3/h
Series RER 220 TD
Power consumption
Air flow
1) Fiberglass-reinforced plastic
¿
¿
¡
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM.
Standstill at 0% PWM, Standstill if control cable is interrupted.
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
230 x 230 mm.
Cover plate 230 x 230 mm, with an air inlet opening
Ø 155 mm, arranged concentrically to the impeller.
2016-01
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m.
Sound pressure level LpA measured at 1 m
distance from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
128
Inlet rings
from p. 253
Max. 8 deep
Tin-plated
1600 m /h
Information
Max.
DC centrifugal fans
3
Ø 225 x 99 mm
DC centrifugal fans
DC axial fans
– Possible special versions:
– Material:
Impeller: GRP1)
(See chapter DC fans - specials)
– Direction of air flow: Axial: Intake,
- Speed signal
Centrifugal: Exhaust
- Go / NoGo alarm
– Direction of rotation: Clockwise,
- Alarm with speed limit
looking towards rotor
- External temperature sensor
– Connection:
Via single wires AWG 18, 20 or
- Internal temperature sensor
AWG 22, TR 64, speed signal
- PWM control input
and control input AWG 22
- Analog control input
– Highlights:
Highly efficient and smoothly
- Multi-option control input
operating 3-phase fan drive
- Humidity protection
Backward-curved impeller
- Salt spray protection
– Weight:
1030 g
- Degree of protection: IP 54
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
Temperature range
VDC
Bel(A)
/
Watts
rpm-1
°C
RER 225-63/18/2 TDMLO
1190
700
48
36...72
7.2
77
2 500
RER 225-63/18/2 TDMO
1340
789
48
36...72
7.8
108
2 800
RER 225-63/18/2 TDO
1600
941
48
36...72
8.1
163
3 300
-20...+55
Hours
Hours
-20...+55
70 000 / 50 000
122 500
-20...+55
55 000 / 40 000
92 500
52 500 / 37 500
87 500
DC fans - specials
Sound power level
VDC
Curve
Voltage range
cfm
Life expectancy L10IPC
(40 °C) see page 17
Nominal voltage
m3/h
Nominal data
Service life L10 (Tmax)
ebm-papst standard
Air flow
Type
Series RER 225 TD
Service life L10 (40 °C)
ebm-papst standard
Air flow
1) Fiberglass-reinforced plastic
¿
¡
¬
ACmaxx / EC fans
Subject to change
Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM.
Standstill at 0% PWM, Type O: Standstill if control cable is interrupted. Type P: Maximum speed if control cable is interrupted.
AC centrifugal fans
AC axial fans
The air flow and sound level of the centrifugal fans
without external housing depend on their individual
installation conditions.
The stated air flow and sound level were recorded
under the following measurement parameters:
Centrifugal fan mounted on a foundation plate
230 x 230 mm.
Cover plate 230 x 230 mm, with an air inlet opening
Ø 146 mm, arranged concentrically to the impeller.
Representatives
129
2016-01
Inlet rings
from p. 252
Max. 8 deep
Air performance measured according to: ISO 5801.
Installation category A, with ebm-papst inlet ring without
contact protection.
Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m.
Sound pressure level LpA measured at 1 m
distance from fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
Accessories
Tin-plated
Max.
1340 m /h
DC centrifugal fans – RadiCal
3
Ø 225 mm
– Material:
Power consumption
Input current
Sound pressure level
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
°C
R3G 225
M3G 074-CF
A
24
16-28
1300
3270
205
8.50
75
-25...+60
p. 262 / J5)
R3G 225
M3G 074-CF
B
48
36-57
1340
3400
230
4.80
73
-25...+60
p. 262 / J5)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage
Nominal data
Nominal voltage range
VDC
Curve
Air flow
–
–
–
–
–
–
–
–
Impeller: PA plastic
Rotor: Painted black
Number of blades:
7
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 44, depending on installation and position
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
B
A
2016-01
Ped
W
I
A
L WA
dB(A)
A
1
3270
205
8.50
81
A
2
3200
208
8.66
78
A
3
3185
213
8.88
74
A
4
3260
194
8.02
77
B
1
3400
230
4.80
83
B
2
3440
257
5.35
80
B
3
3435
260
5.43
76
B
4
3500
239
4.97
78
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the
specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
130
n
rpm-1
Information
DC axial fans
See connection diagram p. 262
Variable
EN 60950-1
EAC
DC centrifugal fans
Technical features:
Cable exit:
Conformity with standard(s):
Approvals:
kg
Inlet ring
R3G 225-RN28 -01
2.1
96358-2-4013
R3G 225-RN18 -02
2.1
96358-2-4013
Clearance for screw
max. 12 - 14 mm
Accessories
AC centrifugal fans
AC axial fans
Accessory part: Inlet ring 96358-2-4013
not included in the standard scope of delivery
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal fans
–
–
–
–
Connection diagrams
P. 262
131
Representatives
Inlet rings
from p. 254
2016-01
PVC AWG 16 cable,
4 x crimped ferrules
Max.
1640 m /h
DC centrifugal fans – RadiCal
3
Ø 250 mm
– Material:
Power consumption
Input current
Sound pressure level
Admissible amb. temp.
Type
Motor
m3/h
rpm-1
W
A
dB(A)
°C
R3G 250
M3G 074-CF
A
24
16-28
1505
2850
175
7.20
73
-25...+60
p. 262 / J5)
R3G 250
M3G 074-CF
B
48
36-57
1640
3100
230
4.80
73
-25...+60
p. 262 / J5)
Technical features and
connection diagram
Nominal speed
VDC
Curve
Nominal data
Nominal voltage range
VDC
Nominal voltage
Air flow
–
–
–
–
–
–
–
–
Impeller: PA plastic
Rotor: Painted black
Number of blades:
7
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 44, depending on installation and position
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
n
rpm-1
Ped
W
I
A
L WA
dB(A)
B
A
A
1
2850
175
7.20
81
A
2
3075
260
10.80
77
A
3
3035
276
11.45
75
A
4
3095
256
10.66
75
B
1
3100
230
4.80
81
B
2
3065
249
5.20
77
B
3
3025
266
5.55
75
B
4
3090
244
5.09
78
2016-01
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suction-side
noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
132
Information
DC axial fans
See connection diagram p. 262
Variable
EN 60950-1
EAC
DC centrifugal fans
Technical features:
Cable exit:
Conformity with standard(s):
Approvals:
kg
Inlet ring
R3G 250-RN46 -01
2.1
96359-2-4013
R3G 250-RNB5 -02
2.1
96359-2-4013
Clearance for screw
max. 12 - 14 mm
Accessories
AC centrifugal fans
AC axial fans
Accessory part: Inlet ring 96359-2-4013
not included in the standard scope of delivery
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal fans
–
–
–
–
Connection diagrams
P. 262
133
Representatives
Inlet rings
from p. 254
2016-01
PVC AWG 16 cable,
4 x crimped ferrules
Max.
2190 m /h
DC centrifugal fans – RadiCal
3
Ø 280 mm
– Material:
Power consumption
Input current
Sound pressure level
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
°C
R3G 280
M3G 074-CF
A
24
16-28
2190
1900
142
5.90
67
-25...+60
p. 262 / J5)
R3G 280
M3G 074-CF
B
48
36-57
2160
1910
140
2.90
67
-25...+60
p. 262 / J5)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
–
Impeller: PP plastic
Rotor: Painted black
Number of blades:
6
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 44, depending on installation and position
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
n
rpm-1
Ped
W
I
A
L WA
dB(A)
A
B
A
1
1900
142
5.90
74
A
2
1870
162
6.76
67
A
3
1840
173
7.21
64
A
4
1905
153
6.36
68
B
1
1910
140
2.90
74
B
2
1845
158
3.30
67
B
3
1830
163
3.40
64
B
4
1900
141
2.93
68
2016-01
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the
specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
134
Information
DC axial fans
See connection diagram p. 262
Variable
EN 60950-1
EAC
DC centrifugal fans
Technical features:
Cable exit:
Conformity with standard(s):
Approvals:
kg
Inlet ring
R3G 280-RN30 -01
2.4
28000-2-4013
R3G 280-RNB1 -02
2.4
28000-2-4013
Clearance for screw
max. 12 - 14 mm
Accessories
AC centrifugal fans
AC axial fans
Accessory part: Inlet ring 28000-2-4013
not included in the standard scope of delivery
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal fans
–
–
–
–
Connection diagrams
P. 262
135
Representatives
Inlet rings
from p. 254
2016-01
PVC AWG 16 cable,
4 x crimped ferrules
Max.
2380 m /h
DC centrifugal fans – RadiCal
3
Ø 310 mm
– Material:
Power consumption
Input current
Sound pressure level
Admissible amb. temp.
Type
Motor
m3/h
rpm-1
W
A
dB(A)
°C
R3G 310
M3G 074-CF
A
24
16-28
2310
1580
108
4.50
64
-25...+60
p. 262 / J5)
R3G 310
M3G 074-CF
B
48
36-57
2380
1620
123
2.60
64
-25...+60
p. 262 / J5)
Technical features and
connection diagram
Nominal speed
VDC
Curve
Nominal data
Nominal voltage range
VDC
Nominal voltage
Air flow
–
–
–
–
–
–
–
–
Impeller: PP plastic
Rotor: Painted black
Number of blades:
6
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 44, depending on installation and position
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
n
rpm-1
Ped
W
I
A
L WA
dB(A)
B
A
A
1
1580
108
4.50
70
A
2
1540
145
6.03
67
A
3
1520
152
6.34
63
A
4
1550
143
5.95
65
B
1
1620
123
2.60
70
B
2
1570
147
3.07
66
B
3
1545
156
3.26
63
B
4
1580
144
3.01
66
2016-01
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the
specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
136
Information
DC axial fans
See connection diagram p. 262
Variable
EN 60950-1
EAC
DC centrifugal fans
Technical features:
Cable exit:
Conformity with standard(s):
Approvals:
kg
Inlet ring
R3G 310-RN99 -01
2.8
31000-2-4013
R3G 310-RN98 -02
2.8
31000-2-4013
Clearance for screw
max. 12 - 14 mm
Accessories
AC centrifugal fans
AC axial fans
Accessory part: Inlet ring 31000-2-4013
not included in the standard scope of delivery
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal fans
–
–
–
–
Connection diagrams
P. 262
137
Representatives
Inlet rings
from p. 254
2016-01
PVC AWG 16 cable,
4 x crimped ferrules
Max.
155 m /h
DC tangential fans
3
201...413 x 50 x 48 mm
– Possible special versions:
Housing: Aluminum
(See chapter DC fans - specials)
Housing side parts: Plastic
- Speed signal
Impeller: Aluminum
- Moisture protection
Direction of air flow: See photo
Connection:
via single wires AWG 24, TR 64
Highlights:
Motor with ball bearing system
Impeller retaining plate with
sleeve bearing
Weight:
235 / 290 / 380 / 415 g
–
–
–
Voltage range
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power consumption
Temperature range
VDC
VDC
db(A)
Bel(A)
/
Watts
°C
Hours
QG 030-148/12
75
44
12
8...14
49
5.7
/
6.2
-20...+60
30 000 / 20 000
50 000
QG 030-198/12
100
59
12
8...14
51
5.8
/
8,0
-20...+60
30 000 / 20 000
50 000
QG 030-303/12
140
82
12
8...14
51
5.8
/
8.7
-20...+60
30 000 / 20 000
50 000
QG 030-353/12
155
91
12
8...14
51
5.9
/
9.6
-20...+60
30 000 / 20 000
50 000
QG 030-148/14
75
44
24
16...28
49
5.7
/
6.2
-20...+60
30 000 / 20 000
50 000
QG 030-198/14
100
59
24
16...28
51
5.8
/
8.0
-20...+60
30 000 / 20 000
50 000
QG 030-303/14
140
82
24
16...28
51
5.8
/
8.7
-20...+60
30 000 / 20 000
50 000
QG 030-353/14
155
91
24
16...28
51
5.9
/
9.6
-20...+60
30 000 / 20 000
50 000
Type
Life expectancy L10IPC
(40 °C) see page 17
Nominal voltage
cfm
Nominal data
Service life L10 (Tmax)
ebm-papst standard
Air flow
m3/h
Series QG 030
Service life L10 (40 °C)
ebm-papst standard
Air flow
–
Hours
Curve
– Material:
¿
¡
¬
√
¿
¡
¬
√
Subject to change
The values for service life were recorded with the fan installed
horizontally.
L
L1
Mass
QG 030-148/ ..
Type
Dimension:
203.4 +1.5
148
235 g
QG 030-198/ ..
260.4 +1.5
198
290 g
QG 030-303/ ..
365.4
+1.5
303
380 g
QG 030-353/ ..
415.4 +1.5
353
415 g
Tangential fans are suitable only for operation with high
air flow and low back-pressure.
2016-01
Air performance measured according to:
ISO 5801.
Installation category A, without contact
protection.
Noise: Total sound power level LWA ISO
103002 measured on a hemisphere with
a radius of 2 m.
Sound pressure level LpA measured at 1 m
distance to fan axis.
The values given are applicable only under the
specified measuring conditions and may differ
depending on the installation conditions.
In the event of deviation from the standard
configuration, the parameters must be
checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
138
Pocket for square nut M3 DIN 562, flat (6x)
Representatives
2016-01
139
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
DC fans - specials
DC centrifugal fans
DC axial fans
Information
Max.
95 m /h
DC centrifugal fans and blowers
3
Ø 85 mm
– Material:
Admissible amb. temp.
m3/h
rpm-1
W
A
dB(A)
Pa
°C
16-28
95
2850
14
0.64
57
0
-25...+60
p. 259 / G)
36-57
95
2850
14
0.32
57
0
-25...+60
p. 259 / G)
VDC
VDC
A
24
A
48
Technical features and
connection diagram
Min. back-pressure
M1G 045-BE
Sound pressure level
*1G 085
Input current
M1G 045-BE
Power consumption
*1G 085
Nominal speed
Motor
Air flow
Type
Nominal voltage range
Nominal data
Nominal voltage
Curve
–
–
–
–
–
–
–
Housing: Die-cast aluminum
Impeller: Hot-dip galvanized sheet steel
Rotor: Galvanized
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 22
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
3180
19
59
—
A
2’
3300
16
57
28
A
3’
3500
15
57
32
A
4’
3800
12
57
37
A
1
2850
14
57
—
A
2
3000
12
55
28
A
3
3180
11
55
32
A
4
3400
9
54
37
A
5
1890
5
46
—
A
6
1970
4
44
25
A
7
2070
4
44
30
A
8
2170
3
42
33
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
140
n
rpm-1
Information
DC centrifugal fans
DC axial fans
See connection diagram p. 259
Axial
EN 60950-1
EAC
kg
Centrifugal blowers
with flange
kg
R1G 085-AB05 -01
0.5
G1G 085-AB05 -01
0.8
R1G 085-AB07 -01
0.5
G1G 085-AB07 -01
0.8
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal blowers
Technical features:
Cable exit:
Conformity with standard(s):
Approvals:
Weight
centrifugal fans
AC centrifugal fans
AC axial fans
Clearance for screw
max. 4 mm
Finger guards
from p. 247
Inlet rings
from p. 253
Connection diagrams
P. 259
141
Representatives
Accessories
Wire end splices
2016-01
–
–
–
–
Max.
95 m /h
DC centrifugal fans and blowers
3
Ø 97 mm
– Material:
Admissible amb. temp.
m3/h
rpm-1
W
A
dB(A)
Pa
°C
16-28
95
2650
16
0.75
59
0
-25...+60
p. 259 / G)
36-57
95
2650
16
0.38
59
0
-25...+60
p. 259 / G)
VDC
VDC
A
24
A
48
Technical features and
connection diagram
Min. back-pressure
M1G 045-BE
Sound pressure level
*1G 097
Input current
M1G 045-BE
Power consumption
*1G 097
Nominal speed
Motor
Air flow
Type
Nominal voltage range
Nominal data
Nominal voltage
Curve
–
–
–
–
–
–
–
Housing: Hot-dip galvanized sheet steel
Impeller: Hot-dip galvanized sheet steel
Rotor: Galvanized
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 22
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
2920
22
62
—
A
2’
3030
21
61
41
A
3’
3300
17
59
48
A
4’
3700
13
58
48
A
1
2650
16
59
—
A
2
2730
15
58
41
A
3
2960
13
56
48
A
4
3290
10
55
48
A
5
1615
4
45
—
A
6
1650
4
45
38
A
7
1745
4
43
46
A
8
1880
3
42
47
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
142
n
rpm-1
Information
DC centrifugal fans
DC axial fans
See connection diagram p. 259
Axial
EN 60950-1
EAC
kg
Centrifugal blowers
with flange
kg
R1G 097-AA05 -01
0.5
G1G 097-AA05 -01
0.8
R1G 097-AA07 -01
0.5
G1G 097-AA07 -01
0.8
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal blowers
Technical features:
Cable exit:
Conformity with standard(s):
Approvals:
Weight
centrifugal fans
AC centrifugal fans
AC axial fans
Clearance for screw
max. 4 mm
Finger guards
from p. 242
Inlet rings
from p. 253
Connection diagrams
P. 259
143
Representatives
Accessories
Wire end splices
2016-01
–
–
–
–
Max.
200 m /h
DC centrifugal fans and blowers
3
Ø 108 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
*1G 108
M1G 055-BD
A
24
16-28
200
3000
42
2.00
65
0
-25...+60
p. 259 / G)
*1G 108
M1G 055-BD
.A
48
36-57
200
3000
42
1.00
65
0
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
Housing: Die-cast aluminum
Impeller: Hot-dip galvanized sheet steel
Rotor: Painted black
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 22
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
3230
55
67
—
A
2’
3410
52
66
33
A
3’
3800
43
65
41
A
4’
4100
35
64
33
A
1
3000
42
65
—
A
2
3140
40
64
33
A
3
3420
32
63
41
A
4
3690
26
63
33
A
5
2300
20
61
—
A
6
2380
17
58
33
A
7
2550
14
55
41
A
8
2720
11
55
33
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
144
n
rpm-1
Information
DC centrifugal fans
DC axial fans
See connection diagram p. 259
Axial
I
EN 60950-1
A (24 VDC) UL, CSA, A (48 VDC) CCC
kg
Centrifugal blowers
with flange
kg
R1G 108-AB17 -02
0.7
G1G 108-AB17 -02
1.4
R1G 108-AB41 -02
0.7
G1G 108-AB41 -02
1.4
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal blowers
Technical features:
Cable exit:
Protection class:
Conformity with standard(s):
Approvals:
Weight
centrifugal fans
AC centrifugal fans
AC axial fans
Clearance for screw
max. 6 mm
Finger guards
from p. 247
Inlet rings
from p. 253
Air filter
P. 254
Connection diagrams
P. 259
145
Representatives
Accessories
Wire end splices
2016-01
–
–
–
–
–
Max.
255 m /h
DC centrifugal fans and blowers
3
Ø 120 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
*1G 120
M1G 055-BD
A
24
16-28
255
2200
40
1.90
62
0
-25...+60
p. 259 / G)
*1G 120
M1G 055-BD
A
48
36-57
255
2200
40
0.95
62
0
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
Housing: Die-cast aluminum
Impeller: Hot-dip galvanized sheet steel
Rotor: Galvanized
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 22
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
2410
50
63
—
A
2’
2620
47
62
58
A
3’
2870
44
61
60
A
4’
3200
36
62
55
A
1
2200
40
62
—
A
2
2410
36
60
59
A
3
2600
32
58
62
A
4
2880
25
58
55
A
5
1870
24
55
—
A
6
1990
21
54
58
A
7
2100
18
53
61
A
8
2310
14
54
54
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
146
n
rpm-1
Information
kg
Centrifugal blowers
with flange
kg
R1G 120-AB67 -02
0.8
G1G 120-AB67 -02
1.6
R1G 120-AB71 -02
0.8
G1G 120-AB71 -02
1.6
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal blowers
DC centrifugal fans
DC axial fans
Technical features:
See connection diagram p. 259
Cable exit:
Axial
Protection class:
I
Conformity with standard(s): EN 60950-1
A (24 VDC) UL, CSA, A (48 VDC) CCC
Approvals:
Weight
centrifugal fans
AC centrifugal fans
AC axial fans
Clearance for screw
max. 6 mm
Finger guards
from p. 247
Inlet rings
from p. 253
Air filter
P. 254
Connection diagrams
P. 259
147
Representatives
Accessories
Wire end splices
2016-01
–
–
–
–
–
Max.
225 m /h
DC centrifugal fans and blowers
3
Ø 133 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
*1G 133
M1G 055-BD
A
24
16-28
225
2000
40
2.20
64
0
-25...+60
p. 259 / G)
*1G 133
M1G 055-BD
A
48
36-57
225
2000
40
1.10
64
0
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
Housing: Hot-dip galvanized sheet steel
Impeller: Hot-dip galvanized sheet steel
Rotor: Galvanized
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 22
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
2170
57
66
—
A
2’
2410
51
66
47
A
3’
2750
44
64
49
A
4’
3200
36
66
32
A
1
2000
45
64
—
A
2
2230
40
64
49
A
3
2540
35
62
51
A
4
2920
27
63
33
A
5
1750
28
60
—
A
6
1910
24
59
50
A
7
2120
20
58
53
A
8
2370
15
59
35
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
148
n
rpm-1
Information
DC centrifugal fans
DC axial fans
See connection diagram p. 259
Lateral
I
EN 60950-1
A (24 VDC) UL, CSA, A (48 VDC) CCC
kg
Centrifugal blowers
with flange
kg
R1G 133-AE19 -02
0.7
G1G 133-DE19 -02
1.3
R1G 133-AE03 -02
0.7
G1G 133-DE03 -02
1.3
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal blowers
Technical features:
Cable exit:
Protection class:
Conformity with standard(s):
Approvals:
Weight
centrifugal fans
AC axial fans
Clearance for screw
max. 6 mm
Finger guards
from p. 247
Inlet rings
from p. 253
Air filter
P. 254
Connection diagrams
P. 259
149
Representatives
Accessories
AC centrifugal fans
Wire end splices
2016-01
–
–
–
–
–
Max.
410 m /h
DC centrifugal fans and blowers
3
Ø 140 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
*1G 140
M1G 055-BD
A
24
16-28
400
1750
54
2.50
63
0
-25...+60
p. 259 / G)
*1G 140
M1G 055-BD
A
48
36-57
410
1750
54
1.30
63
0
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
Housing: Die-cast aluminum
Impeller: Hot-dip galvanized sheet steel
Rotor: Painted black
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 22
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
1850
65
64
—
A
2’
2020
61
61
50
A
3’
2200
57
59
54
A
4’
2550
43
60
40
A
1
1750
54
63
—
A
2
1900
50
59
51
A
3
2030
45
58
54
A
4
2310
32
58
40
A
5
1500
34
60
—
A
6
1580
29
56
50
A
7
1670
25
54
53
A
8
1880
19
53
41
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
150
n
rpm-1
Information
DC centrifugal fans
DC axial fans
See connection diagram p. 259
Axial
I
EN 60950-1
A (48 VDC) CCC
kg
Centrifugal blowers
with flange
kg
R1G 140-AV17 -02
1.0
G1G 140-AV17 -02
2.3
R1G 140-AV21 -02
1.0
G1G 140-AV21 -02
2.3
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal blowers
Technical features:
Cable exit:
Protection class:
Conformity with standard(s):
Approvals:
Weight
centrifugal fans
–
–
–
–
–
AC centrifugal fans
AC axial fans
Clearance for screw
max. 6 mm
Inlet rings
from p. 253
Air filter
P. 254
Connection diagrams
P. 259
151
Representatives
Finger guards
from p. 247
2016-01
Accessories
Wire end splices
Max.
470 m /h
DC centrifugal fans and blowers
3
Ø 146 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
*1G 146
M1G 074-BF
A
24
16-28
470
2200
100
5.00
68
0
-25...+60
p. 259 / G)
*1G 146
M1G 074-BF
A
48
36-57
465
2150
100
2.60
67
0
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
Housing: Die-cast aluminum
Impeller: Hot-dip galvanized sheet steel
Rotor: Painted black
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 42
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
2400
140
70
—
A
2’
2650
130
67
45
A
3’
3000
110
66
49
A
4’
3300
100
67
45
A
1
2200
100
68
—
A
2
2445
90
65
46
A
3
2750
84
64
49
A
4
3025
77
65
45
A
5
1890
68
63
—
A
6
2075
57
60
46
A
7
2250
48
61
49
A
8
2335
41
61
45
A
9
1520
37
59
—
A
10
1670
32
55
46
A
11
1815
27
55
49
A
12
1920
23
55
45
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
152
n
rpm-1
Information
DC centrifugal fans
DC axial fans
See connection diagram p. 259
Axial
I
EN 60950-1
UL, CSA, CCC (only centrifugal blowers)
kg
Centrifugal blowers
with flange
kg
R1G 146-AA07 -52
1.4
G1G 146-BA07 -52
2.8
R1G 146-AA11 -52
1.4
G1G 146-BA11 -52
2.8
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal blowers
Technical features:
Cable exit:
Protection class:
Conformity with standard(s):
Approvals:
Weight
centrifugal fans
–
–
–
–
–
AC centrifugal fans
AC axial fans
Clearance for screw
max. 6 mm
Inlet rings
from p. 253
Air filter
P. 254
Connection diagrams
P. 259
153
Representatives
Finger guards
from p. 247
2016-01
Accessories
Wire end splices
Max.
505 m /h
DC centrifugal fans and blowers
3
Ø 160 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
*1G 160
M1G 074-BF
A
24
16-28
505
1750
105
5.80
67
0
-25...+60
p. 259 / G)
*1G 160
M1G 074-BF
A
48
36-57
505
1750
105
2.90
67
0
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
Housing: Die-cast aluminum
Impeller: Hot-dip galvanized sheet steel
Rotor: Painted black
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 42
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
1890
134
68
—
A
2’
2200
118
67
52
A
3’
2500
110
67
57
A
4’
2900
102
69
52
A
1
1750
105
67
—
A
2
2030
95
66
52
A
3
2270
90
65
57
A
4
2550
81
67
44
A
5
1580
72
62
—
A
6
1810
66
62
52
A
7
2000
58
62
57
A
8
2200
48
63
54
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
154
n
rpm-1
Information
DC centrifugal fans
DC axial fans
See connection diagram p. 259
Axial
I
EN 60950-1
UL, CSA
kg
Centrifugal blowers
with flange
kg
R1G 160-AH29 -52
1.4
G1G 160-BH29 -52
2.8
R1G 160-AH39 -52
1.4
G1G 160-BH39 -52
2.8
ACmaxx / EC fans
Centrifugal fans
DC fans - specials
Weight
centrifugal blowers
Technical features:
Cable exit:
Protection class:
Conformity with standard(s):
Approvals:
Weight
centrifugal fans
–
–
–
–
–
AC centrifugal fans
AC axial fans
Clearance for screw
max. 6 mm
Inlet rings
from p. 253
Air filter
P. 254
Connection diagrams
P. 259
155
Representatives
Finger guards
from p. 247
2016-01
Accessories
Wire end splices
Max.
700 m /h
DC centrifugal blowers
3
Ø 133 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
D1G 133
M1G 074-BF
A
24
16-28
700
1780
105
5.60
62
50
-25...+60
p. 259 / G)
D1G 133
M1G 074-BF
A
48
36-57
700
1780
105
2.80
62
50
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
–
Housing: Galvanized sheet steel
Impeller: Galvanized sheet steel
Rotor: Painted black
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 42
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Design:
SAL motor mounted with vibration damping on both sides
Bearings:
Maintenance-free ball bearings
Subject to change
n
rpm-1
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
LpA
dB(A)
htL
%
A
1’
—
—
—
—
A
2’
2050
121
63
49
A
3’
2490
106
62
41
A
4’
2820
100
62
37
A
1
1780
105
62
—
A
2
1900
97
61
49
A
3
2310
86
59
41
A
4
2630
80
60
37
1500
73
A
5
1720
67
59
—
A
6
2020
58
57
49
A
7
49
41
A
2230
56
8
56
37
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
156
Ped
W
Information
DC axial fans
See connection diagram p. 259
Variable
I
EN 60950-1
UL, CSA; A (48 VDC) also CCC
DC centrifugal fans
Technical features:
Cable exit:
Protection class:
Conformity with standard(s):
Approvals:
kg
D1G 133-AB29 -52
3.3
D1G 133-AB39 -52
3.3
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
Centrifugal blowers
without flange
DC fans - specials
Weight
centrifugal blowers
Finger guards
from p. 246
Connection diagrams
P. 259
157
2016-01
Accessories
Wire end splices
Representatives
–
–
–
–
–
Max.
1020 m /h
DC centrifugal blowers
3
Ø 133 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
D1G 133
M1G 074-BF
A
24
16-28
1020
1580
118
6.00
64
0
-25...+60
p. 259 / G)
D1G 133
M1G 074-BF
A
48
36-57
1020
1580
118
3.00
64
0
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
–
Housing: Galvanized sheet steel
Impeller: Galvanized sheet steel
Rotor: Painted black
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 42
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Design:
SAL motor mounted with vibration damping on both sides
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
1700
145
65
—
A
2’
1930
133
62
38
A
3’
2290
122
59
41
A
4’
2700
99
61
32
A
1
1580
118
64
—
A
2
1790
107
61
38
A
3
2100
95
57
41
A
4
2410
73
58
32
A
5
1400
78
60
—
A
6
1580
70
56
38
A
7
1760
56
53
41
A
8
2000
44
53
32
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
158
n
rpm-1
Information
kg
D1G 133-DC13 -52
3.4
D1G 133-DC17 -52
3.4
DC centrifugal fans
Finger guards
from p. 246
Connection diagrams
P. 259
159
2016-01
Wire end splices
Representatives
Accessories
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
Centrifugal blowers
without flange
DC fans - specials
Weight
centrifugal blowers
–
–
–
–
See connection diagram p. 259
Interference emission acc. to EN 55022, class B
Immunity to interference acc. to EN 61000-6-2
Cable exit:
Variable
Protection class:
I
Conformity with standard(s): EN 60950-1
Approvals:
UL, CSA
DC axial fans
– Technical features:
– EMC (24 VDC):
Max.
1000 m /h
DC centrifugal blowers
3
Ø 146 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
D1G 146
M1G 074-CF
A
24
16-28
1000
1350
105
5.10
61
0
-25...+60
p. 259 / G)
D1G 146
M1G 074-CF
A
48
36-57
1000
1350
105
2.60
61
0
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
–
Housing: Galvanized sheet steel
Impeller: Galvanized sheet steel
Rotor: Painted black
Direction of rotation:
Clockwise, looking towards rotor
Degree of protection:
IP 42
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Design:
SAL motor mounted with vibration damping on both sides
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
1460
129
63
—
A
2’
1680
119
60
53
A
3’
1890
111
58
61
A
4’
2240
95
59
55
A
1
1350
105
61
—
A
2
1570
95
58
53
A
3
1750
88
56
61
A
4
2010
70
57
55
A
5
1210
70
56
—
A
6
1360
60
54
53
A
7
1460
53
52
61
A
8
1670
42
51
55
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
160
n
rpm-1
Information
kg
D1G 146-AA19 -52
3.5
D1G 146-AA33 -52
3.5
DC centrifugal fans
AC centrifugal fans
AC axial fans
ACmaxx / EC fans
Centrifugal blowers
without flange
DC fans - specials
Weight
centrifugal blowers
Finger guards
from p. 246
Connection diagrams
P. 259
161
2016-01
Accessories
Wire end splices
Representatives
–
–
–
–
See connection diagram p. 259
Interference emission acc. to EN 55022, class B
Immunity to interference acc. to EN 61000-6-2
Cable exit:
Variable
Protection class:
I
Conformity with standard(s): EN 60950-1
Approvals:
UL, CSA
DC axial fans
– Technical features:
– EMC (24 VDC):
Max.
980 m /h
DC centrifugal blowers
3
Ø 160 mm
– Material:
Power consumption
Input current
Sound pressure level
Min. back-pressure
Admissible amb. temp.
Motor
VDC
m3/h
rpm-1
W
A
dB(A)
Pa
°C
D1G 160
M1G 074-CF
A
24
16-28
980
1250
112
5.60
60
0
-25...+60
p. 259 / G)
D1G 160
M1G 074-CF
A
48
36-57
980
1250
112
2.90
60
0
-25...+60
p. 259 / G)
Technical features and
connection diagram
Nominal speed
Type
Nominal voltage range
Nominal data
Nominal voltage
VDC
Curve
Air flow
–
–
–
–
–
–
–
–
Housing: Galvanized sheet steel
Impeller: Galvanized sheet steel
Rotor: Painted black
Direction of rotation:
Counterclockwise, looking towards rotor
Degree of protection:
IP 42
Insulation class:
"B"
Installation position:
Any
Condensation drainage holes: None
Mode of operation:
Continuous operation (S1)
Design:
SAL motor mounted with vibration damping on both sides
Bearings:
Maintenance-free ball bearings
Subject to change
Curves:
UN = nominal
voltage
(24 V /48 V)
UR = overvoltage
(28 V / 57 V)
2016-01
Ped
W
LpA
dB(A)
htL
%
A
1’
1330
142
63
—
A
2’
1520
128
61
64
A
3’
1790
115
59
66
A
4’
2090
105
60
60
A
1
1250
112
60
—
A
2
1420
102
59
64
A
3
1660
92
58
66
A
4
1900
80
58
60
A
5
1100
75
58
—
A
6
1250
69
56
64
A
7
1420
58
54
66
A
8
1580
47
53
60
Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under
the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions
162
n
rpm-1
Information
DC axial fans
See connection diagram p. 259
Variable
I
EN 60950-1
UL, CSA
DC centrifugal fans
Technical features:
Cable exit:
Protection class:
Conformity with standard(s):
Approvals:
kg
D1G 160-DA19 -52
3.6
D1G 160-DA33 -52
3.6
AC axial fans
ACmaxx / EC fans
Centrifugal blowers
without flange
DC fans - specials
Weight
centrifugal blowers
Finger guards
from p. 246
Connection diagrams
P. 259
163
2016-01
Accessories
AC centrifugal fans
Wire end splices
Representatives
–
–
–
–
–
2016-01
164