Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials 91 DC centrifugal fans 93 95 138 140 Representatives DC centrifugal fan overview DC centrifugal fans DC tangential fans DC centrifugal fans and blowers 2016-01 DC axial fans Information DC centrifugal fans DC centrifugal fans Technical information Product line Voltage range Our centrifugal product line includes fans for every application. Whether Many of our DC fans can be operated on voltages that are up to 50% as free-running impellers with a diameter between 97 mm and 225 mm, lower and 25% higher than their nominal voltage (see voltage range in or as assemblies in a ready-to-install, compact housing with inlet ring the technical tables). This allows the air performance to be adapted to the with an edge length between 51 mm and 270 mm. Of course, all models cooling requirements and the noise to be reduced, even if the fan does feature highly efficient, brushless motor technology. not have a control input. Electronic protection against reverse polarity Closed-loop speed control and monitoring ebm-papst DC fans have electronically commutated drives with electronic Closed-loop speed control and function monitoring are becoming protection against reverse polarity. The electronics are integrated in the increasingly important in many applications. ebm-papst offers many fans fan’s impeller hub to save space. in the standard design with a control input and open-collector speed signal. Product life expectancy A distinctive feature of DC fan technology is the amazing product life S-Force centrifugal RadiCal expectancy. The outstanding efficiency of the brushless drive results in The new S-Force centrifugal fans provide peak performance among fans lower heat stress for the bearings, which significantly increases the of this type. With air flow capacity of over 1500 m³/h and a pressure service life of the fan. increase of up to 1000 pascals, the highest heat flows are manageable. The models are extremely efficient due to the multi-pole, electronically Degree of protection commutated drive motors, and can be adapted individually to every DC fans with sleeve and ball bearings are powered by class E insulated application thanks to intelligent motor features. Some models use our motors. All ebm-papst fans conform to the requirements of degree of new, highly efficient RadiCal impellers. protection IP 20. Fans conforming to IP 54 / IP 68 and special degrees of 2016-01 protection are also available. 92 Information Page 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 114 116 117 118 119 120 121 122 124 126 128 129 130 132 134 136 138 140 142 144 146 148 150 152 154 156 158 160 162 NEW Subject to change 10 20 30 40 50 60 70 80 90 100 200 300 400 500 600 700 800 900 1000 2000 2500 93 2016-01 m3/h DC centrifugal fans 60 DC fans - specials 50 ACmaxx / EC fans 40 AC axial fans 18...24 9.6 22...28 56...61 40...55 64...80 55 60...137 118 139...209 59...444 630...930 1090...1100 1040...1450 220 86...104 162...190 320...390 250 110...166 460...565 255 360 800 600...980 650...970 880...930 1200...1215 1063...1250 1190...1600 1300...1340 1505...1640 2160...2190 2310...2380 75...155 95 95 200 255 225 400...410 465...470 505 700 1020 1000 980 30 AC centrifugal fans RV 40 RLF 35 RL 48 RL 65 RL 90 N RLF 100 RG 90 N RG 125 N RG 140 NTD RG 160 N RG 160 NTD RG 190 TD RG 220 TD RG 225 TD RET 97 TD REF 100 RER 101 N RER 120 TD R1G 120 RER 125 N RER 133 TD RER 160 N RER 160 NTD REF 175 TD RER 175 TD RER 190 TD R3G 190 R3G 220 RER 220 TD RER 225 TD R3G 225 R3G 250 R3G 280 R3G 310 QG 030 *1G 085 *1G 097 *1G 108 *1G 120 *1G 133 *1G 140 *1G 146 *1G 160 D1G 133 D1G 133 D1G 146 D1G 160 20 Accessories 105 x 59 x 79 51 x 15 c 76 x 27 97 x 93.5 x 33 c 121 x 37 c 127 x 25 c 135 x 38 c 180 x 40 c 180 x 40 c 220 x 56 c 220 x 56 c 226 x 85 c 270 x 99 c 270 x 119 Ø 97 x 41 Ø 104 x 25 Ø 101 x 52 Ø 120 x 54 Ø 120 Ø 138 x 35 Ø 133 x 91 Ø 165 x 51 Ø 165 x 51 Ø 175 x 55 Ø 175 x 69 Ø 190 x 69 Ø 190 Ø 220 Ø 220 x 71 Ø 225 x 99 Ø 225 Ø 250 Ø 280 Ø 310 201...413 x 50 x 48 Ø 85 Ø 97 Ø 108 Ø 120 Ø 133 Ø 140 Ø 146 Ø 160 Ø 133 Ø 133 Ø 146 Ø 160 10 Representatives m3/h mm c Air flow Series Dimension Overview of air performance DC axial fans Centrifugal fans for DC operation Centrifugal fans for DC operation Spee leev EC s SINT Dim VDE , UL, ensio n CSA e be ar ings d sig / ball nal bear ings Go / NoG o alarm Alarm with spee d lim Exte rnal it t e m pera Inter ture nal t emp sens eratu PWM o re se r cont nsor r o l inp Analo u t g co ntro l inp Mult ut i-op tions cont rol in Mois put ture prot IP > e c tion = 54 IP 68 Salt spra y pro tectio n Page Overview of technically feasible designs Centrifugal fans mm NEW Series OPTIONAL P. 105 x 59 x 79 RV 40 • • – – – – – – – • – – – 95 c 51 x 15 RLF 35 yes • – – – – • – – • – – – 96 c 76 x 27 RL 48 yes • • • • • • • – • – – – 97 97 x 93.5 x 33 RL 65 yes • • • • • • • – • – – – 98 c 121 x 37 RL 90 N yes • • • • • • • – • • • • 99 c 127 x 25 RLF 100 yes • • • • • • • – • • – – 100 c 135 x 38 RG 90 N yes • • • • • • • – • • • • 101 c 180 x 40 RG 125 N yes • • • • • • • – • • • • 102 c 180 x 40 RG 140 NTD yes • • • • – • • • • • • • 103 c 220 x 56 RG 160 N yes • • • • • • • – • • – • 104 c 220 x 56 RG 160 NTD yes • • • • • • • – • • – • 105 c 226 x 85 RG 190 TD yes • • • • • • • • • • – • 106 c 270 x 99 RG 220 TD yes • • • • • • • – • • – • 107 c 270 x 132 RG 225 TD yes • • • • • • • – • • – • 108 Ø 97 x 41 RET 97 TD yes • • • • • • • – • – – – 109 Ø 100 x 25 REF 100 yes • • • • • • • – • • – – 110 Ø 101 x 52 RER 101 N yes • • • • • • • – • – – – 111 Ø 120 x 54 RER 120 TD yes • • • • • • • – • – – – 112 Ø 138 x 35 RER 125 N yes • • • • • • • – • • • • 116 Ø 133 x 91 RER 133 TD yes • • • • • • • • • • – • 117 Ø 165 x 51 RER 160 N yes • • • • • • • – • • – • 118 Ø 165 x 51 RER 160 NTD yes • • • • • • • – • 119 Ø 175 x 55 REF 175 TD yes • • • • • • • • • • – – 120 Ø 175 x 69 RER 175 TD yes • • • • • • • • • • – • 121 Ø 190 x 69 RER 190 TD yes • • • • • • • • • • – • 122 Ø 220 x 71 RER 220 TD yes • • • • • • • • • • – • 128 Ø 225 x 99 RER 225 TD yes • • • • • • • • • • – • 129 201...413 x 50 x 48 QG 030 yes • – – – – – • – – – 138 / / / – – • – – Please note that these special versions are not possible for all voltages and speeds, and not in all combinations. The special versions are designed for specific customers and projects. As a rule they are not available off the shelf and are subject to minimum volumes. Please consult your customer support representative about the feasibility of your special variant. Subject to change – Not yet available • Available Sleeve bearings Ball bearings Optional special versions (see page 12) On the catalog pages and in the overview on page 12, we provide versions are designed for specific customers and projects and are information about the special designs that are technically feasible in usually not available off the shelf. the fan series. Please note that these special versions are not possible 2016-01 for all voltages and speeds, and not in all combinations. The special 94 24 m /h Information Max. DC centrifugal fans 3 105 x 59 x 79 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Direction of air flow: Axial: Intake, - Moisture protection Centrifugal: Exhaust Connection: via single wires AWG 26, TR 64 Highlights: Forward-curved impeller Weight: 100 g – – – DC centrifugal fans – DC axial fans – Material: RV 40-18/12 L 18 10.6 12 9...16 RV 40-18/12 H 24 14.1 12 9...16 Watts rpm-1 °C Hours Hours 4.0 2.0 3 900 -20...+70 70 000 / 35 000 117 500 5.0 4.5 4 800 -20...+70 50 000 / 25 000 85 000 DC fans - specials / Curve Bel(A) Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings VDC Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range cfm Temperature range Nominal voltage m3/h Nominal data Nominal speed Air flow Type Series RV 40 Power consumption Air flow 1) Fiberglass-reinforced plastic ¿ ¡ Ø 30 Ø 31 2,3 45,78 60,4 27 42,04 Ø 40 Ø 46,5 Ansaugöffnung 10,5 Accessories 4,2 (2x) 18 36,35 12 58,85 2,51 44,9 32,4 95 Representatives 18,35 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The acoustic values are only valid for the described measurement setup and may vary depending on the installation situation. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions AC centrifugal fans AC axial fans ACmaxx / EC fans Subject to change Max. 9.6 m /h DC centrifugal fans 3 51 x 15 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal - PWM control input Direction of air flow: Axial: Intake, - Moisture protection Centrifugal: Exhaust Connection: via single wires AWG 26, TR 64 Highlights: Forward-curved impeller Weight: 40 g – Material: – – – – 6 700 -20...+70 60 000 / 30 000 102 500 5.5 4.3 6 700 -20...+70 60 000 / 30 000 102 500 VDC VDC Bel(A) RLF 35-8/12 N 9.6 5.64 12 8...13.2 RLF 35-8/14 N 9.6 5.64 24 14...28 Subject to change Tin-pla te d 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 96 Curve 3.5 cfm Life expectancy L10IPC (40 °C) see page 17 Temperature range 5.5 m3/h Service life L10 (Tmax) ebm-papst standard Nominal speed Hours Type Nominal data Service life L10 (40 °C) ebm-papst standard Power consumption Hours Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series RLF 35 Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic ¿ ¿ 28 m /h Information Max. DC centrifugal fans 3 76 x 27 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Direction of air flow: Axial: Intake, - Go- / NoGo alarm Centrifugal: Exhaust - Alarm with speed limit Connection: via single wires AWG 26, TR 64 - External temperature sensor Highlights: Forward-curved impeller - Internal temperature sensor Weight: 75 g - PWM control input - Analog control input - Moisture protection – – – DC centrifugal fans – DC axial fans – Material: RL 48-19/12 ML 22 12.9 12 8...15 5.3 5.0 RL 48-19/12 28 16.5 12 8...13.5 5.7 4.6 RL 48-19/14 ML 22 12.9 24 18...28 5.3 RL 48-19/14 28 16.5 24 18...26.4 5.7 rpm-1 °C Hours Hours 3 500 -20...+70 70 000 / 35 000 117 500 4 400 -20...+70 60 000 / 30 000 102 500 5.0 3 500 -20...+70 70 000 / 35 000 117 500 4.4 4 400 -20...+70 60 000 / 30 000 102 500 DC fans - specials Watts ¿ ¡ ¿ ¡ ACmaxx / EC fans Power consumption / Curve Sintec sleeve bearings Ball bearings Bel(A) Life expectancy L10IPC (40 °C) see page 17 Sound power level VDC Service life L10 (Tmax) ebm-papst standard Voltage range VDC AC centrifugal fans AC axial fans Subject to change Tin-plate Accessories d 97 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Representatives Type Service life L10 (40 °C) ebm-papst standard Nominal voltage cfm Nominal data Temperature range Air flow m3/h Series RL 48 Nominal speed Air flow 1) Fiberglass-reinforced plastic Max. 61 m /h DC centrifugal fans 3 97 x 93.5 x 33 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials): Impeller: GRP1) - Speed signal Direction of air flow: Axial: Intake, - Go / NoGo alarm Centrifugal: Exhaust - Alarm with speed limit Connection: via single wires AWG 26, TR 64 - External temperature sensor Highlights: Forward-curved impeller - Internal temperature sensor Weight: 170 g - PWM control input - Analog control input - Moisture protection – Material: – – – – 4 500 -20...+70 60 000 / 30 000 102 500 19.2 4 900 -20...+55 55 000 / 40 000 92 500 12...26.4 6.6 14.0 4 500 -20...+70 60 000 / 30 000 102 500 12...26.4 6.8 18.0 4 900 -20...+60 55 000 / 35 000 92 500 VDC VDC Bel(A) RL 65-21/12 56 32,9 12 6.8...13.8 RL 65-21/12 H 61 35,8 12 6.8...13.2 RL 65-21/14 56 32,9 24 RL 65-21/14 H 61 35,8 24 Subject to change Snap-in fins for easy latch Tin-pla te d 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 98 Curve 15.0 6.8 cfm Life expectancy L10IPC (40 °C) see page 17 Temperature range 6.6 m3/h Service life L10 (Tmax) ebm-papst standard Nominal speed Hours Type Nominal data Service life L10 (40 °C) ebm-papst standard Power consumption Hours Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series RL 65 Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic ¿ ¡ ¿ ¡ 55 m /h Information Max. DC centrifugal fans 3 121 x 37 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Base plate: Sheet steel - Go / NoGo alarm Direction of air flow: Axial: Intake, - Alarm with speed limit Centrifugal: Exhaust - External temperature sensor Connection: via single wires AWG 22, TR 64 - Internal temperature sensor Highlights: Forward-curved impeller - PWM control input Weight: 420 g - Analog control input - Moisture protection - Salt spray protection - Degree of protection:IP 54 / IP 68 – – – RL 90-18/12 N 40 23.5 12 7...15 RL 90-18/14 NG 40 23.5 24 RL 90-18/14 N 40 23.5 RL 90-18/18 NH 55 32.4 rpm-1 °C Hours Hours 5.8 6.3 2 500 -30...+75 62 500 / 27 500 105 000 12...28 5.8 5.6 2 500 -20...+75 62 500 / 27 500 105 000 24 12...28 5.8 5.6 2 500 -30...+75 62 500 / 27 500 105 000 48 36...53 6.9 14.7 3 500 -30...+65 32 500 / 17 500 55 000 Curve Watts DC fans - specials / ¿ ¿ ¿ ¡ ACmaxx / EC fans Bel(A) Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings VDC Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range cfm Temperature range Nominal voltage m3/h AC centrifugal fans AC axial fans Subject to change 37,3 + 0,7 Accessories 26,5 54 57,6 80 104,8 + 0,2 120,6 2 67,4 + 0,4 3,5 2,5 97 71,4 + 0,2 6+1 4,2 + 0,4 100,8 112,7 + 0,2 120,6 + 0,2 15,5 30+_ 0,3 6+ 0,3 Tin-plated 12±0,5 *Federmutter oder 8-32UNC. Einschraubtiefe max.12,5 Screw clip M4M4 or 8-32UNC. Screw-in depth max. 12.5 min. min.9,0 9.0 99 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The acoustic values are only valid for the described measurement setup and may vary depending on the installation situation. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 310 +10 45 60,3 Representatives Nominal data Nominal speed Air flow Type Series RL 90 N Power consumption Air flow 1) Fiberglass-reinforced plastic DC centrifugal fans – DC axial fans – Material: Max. 80 m /h DC centrifugal fans 3 127 x 25 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Base plate: Sheet steel - Go / NoGo alarm Direction of air flow: Axial: Intake, - Alarm with speed limit Centrifugal: Exhaust - External temperature sensor Connection: via single wires AWG 22, TR 64 - Internal temperature sensor Highlights: Optional protective cap for - PWM control input outlet opening - Analog control input Backward-curved impeller - Moisture protection Weight: 320 g - Degree of protection: IP 54 – Material: – – – – 12 8...15 64 37.7 24 64 37.7 48 Air flow 64 RLF 100-11/14 RLF 100-11/18 Watts rpm-1 °C Hours Hours 6.4 8.0 5 100 -20...+75 80 000 / 30 000 135 000 16...30 6.4 8.0 5 100 -20...+75 80 000 / 30 000 135 000 36...60 6.4 8.6 5 100 -20...+75 80 000 / 30 000 135 000 High speed models with open-collector tachometer and PWM speed control. RLF 100-11/12/2 HP-200 80 47.1 12 10...13.2 7.5 18.6 6 400 -20...+60 72 500 / 45 000 122 500 RLF 100-11/18/2 HP-182 80 47.1 48 43...53 7.5 17.0 6 400 -20...+70 72 500 / 35 000 122 500 Subject to change 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 100 Tin-p la ted Curve 37.7 RLF 100-11/12 Life expectancy L10IPC (40 °C) see page 17 / Service life L10 (Tmax) ebm-papst standard Sintec sleeve bearings Ball bearings Bel(A) Service life L10 (40 °C) ebm-papst standard Sound power level VDC m3/h Temperature range Voltage range VDC Type Nominal data Nominal speed Nominal voltage cfm Series RLF 100 Power consumption Air flow 1) Fiberglass-reinforced plastic ¿ ¿ ¿ ¡ ¡ 55 m /h Information Max. DC centrifugal fans 3 135 x 38 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Base plate: Sheet steel - Go / NoGo alarm Direction of air flow: Axial: Intake, - Alarm with speed limit Centrifugal: Exhaust - External temperature sensor Connection: Via single wires AWG 22, TR 64 - Internal temperature sensor 48 V model: Flat plug - PWM control input 6.3 x 0.8 mm for ground - Analog control input conductor - Moisture protection Highlights: Forward-curved impeller - Salt spray protection Weight: 440 g - Degree of protection: IP 54 / IP 68 – – – 32.4 12 7...15 RG 90-18/14 NG 55 32.4 24 RG 90-18/14 N 55 32.4 RG 90-18/18 N 55 32.4 °C Hours Hours 5.5 6.7 2 200 -30...+75 62 500 / 27 500 105 000 12...28 5.5 6.2 2 200 -10...+75 62 500 / 27 500 105 000 24 12...28 5.5 6.2 2 200 -30...+75 62 500 / 27 500 105 000 48 36...56 5.5 6.1 2 200 -30...+75 62 500 / 27 500 105 000 DC fans - specials 55 rpm-1 ¿ ¿ ¿ ¿ ACmaxx / EC fans RG 90-18/12 N Watts Curve / Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings Bel(A) Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range VDC Tin-p la ted 101 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans Subject to change Representatives Type Temperature range Nominal voltage cfm Nominal data Nominal speed Air flow m3/h Series RG 90 N Power consumption Air flow 1) Fiberglass-reinforced plastic DC centrifugal fans – DC axial fans – Material: Max. 137 m /h DC centrifugal fans 3 180 x 40 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Base plate: Sheet steel - Go / NoGo alarm Direction of air flow: Axial: Intake, - Alarm with speed limit Centrifugal: Exhaust - External temperature sensor Connection: Via single wires AWG 22, TR 64 - Internal temperature sensor 48 V model: Flat plug - PWM control input 6.3 x 0.8 mm for ground - Analog control input conductor - Moisture protection Highlights: Backward-curved impeller - Salt spray protection Weight: 730 g - Degree of protection: IP 54 / IP 68 – Material: – – – – 1 750 -30...+75 70 000 / 30 000 117 500 5.2 2 550 -30...+75 62 500 / 27 500 105 000 12...28 4.8 2.0 1 750 -30...+75 70 000 / 30 000 117 500 12...28 5.8 4.9 2 550 -30...+75 62 500 / 27 500 105 000 48 36...56 5.8 4.8 2 550 -30...+75 62 500 / 27 500 105 000 48 36...56 7.0 19.0 4 000 -20...+70 55 000 / 27 500 92 500 VDC VDC Bel(A) RG 125-19/12 NM 60.0 35.3 12 7...15 RG 125-19/12 N 87.5 51.5 12 7...15 RG 125-19/14 NM 60.0 35.3 24 RG 125-19/14 N 87.5 51.5 24 RG 125-19/18 N 87.5 51.5 RG 125-19/18 NH 137 80.6 Subject to change 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 102 Tin-p la ted Curve 2.0 5.8 cfm Life expectancy L10IPC (40 °C) see page 17 Temperature range 4.8 m3/h Service life L10 (Tmax) ebm-papst standard Nominal speed Hours Type Nominal data Service life L10 (40 °C) ebm-papst standard Power consumption Hours Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series RG 125 N Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic ¿ ¡ ¿ ¡ ¡ ¬ Information 118 m /h DC centrifugal fans 3 Max. 180 x 40 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Base plate: Sheet steel - Go / No-go alarm Direction of air flow: Axial: Intake, - Alarm with speed limit Centrifugal: Exhaust - External temperature sensor Connection: via single wires AWG 22, TR 64 - PWM control input Highlights: Backward-curved impeller - Analog control input 3-phase fan drive with special - Multi-option control input commutation electronics for - Moisture protection extremely low-noise operation - Salt spray protection Weight: 750 g - Degree of protection: IP 54 – – – DC centrifugal fans – DC axial fans – Material: 118 69.4 24 20.4...27.6 6.0 Watts rpm-1 °C Hours Hours 9.3 2 500 -20...+70 62 500 / 32 500 105 000 DC fans - specials RG 140-22/14 N/2 TDPU ¿ Subject to change n rpm-1 Ped W LwA dB(A) 2504 2504 2504 2504 9 9 9 9 61 61 62 64 AC centrifugal fans AC axial fans ACmaxx / EC fans Higher performance levels on request. 10 20 20 30 40 40 60 50 80 60 100 cfm Accessories Tin-p la ted 103 Representatives 0 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 2016-01 0,4 50 0,3 100 0,2 0,5 150 0,6 0,7 200 0,1 NEW / Curve Bel(A) Life expectancy L10IPC (40 °C) see page 17 VDC Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range cfm Temperature range Nominal voltage m3/h Nominal speed Air flow Type Nominal data Power consumption Air flow Series RG 140 NTD Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic Max. 209 m /h DC centrifugal fans 3 220 x 56 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Base plate: Sheet steel - Go / NoGo alarm Direction of air flow: Axial: Intake, - Alarm with speed limit Centrifugal: Exhaust - External temperature sensor Connection: Via single wires AWG 22, TR 64 - Internal temperature sensor 48 V model: Flat plug - PWM control input 6.3 x 0.8 mm for ground - Analog control input conductor - Moisture protection Highlights: Backward-curved impeller - Salt spray protection Weight: 1.4 kg - Degree of protection: IP 54 – Material: – – – – Bel(A) / Watts rpm-1 °C Hours Hours RG 160-28/12 NM 139 81 12 7...14 5.6 7.5 1 900 -20...+70 80 000 / 40 000 135 000 RG 160-28/12 N 209 123 12 7.5...14 6.6 21.0 2 850 -20...+70 70 000 / 35 000 117 500 RG 160-28/14 NM 139 81 24 12...28 5.6 7.0 1 900 -20...+70 80 000 / 40 000 135 000 RG 160-28/14 N 209 123 24 12...28 6.6 20.0 2 850 -20...+70 70 000 / 35 000 117 500 RG 160-28/18 N 209 123 48 28...60 6.6 20.0 2 850 -20...+70 70 000 / 35 000 117 500 Subject to change 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 104 Tin-p la ted Curve VDC Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings VDC Service life L10 (Tmax) ebm-papst standard Sound power level cfm Service life L10 (40 °C) ebm-papst standard Voltage range Type Temperature range Nominal voltage Nominal data Nominal speed Air flow m3/h Series RG 160 N Power consumption Air flow 1) Fiberglass-reinforced plastic ¿ ¡ ¿ ¡ ¡ 444 m /h Information Max. DC centrifugal fans 3 220 x 56 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Base plate: Sheet steel - Go / NoGo alarm Direction of air flow: Axial: Intake, - Alarm with speed limit Centrifugal: Exhaust - External temperature sensor Connection: Via single wires AWG 22, TR 64 - Internal temperature sensor 48 V model: Flat plug - PWM control input 6.3 x 0.8 mm for ground - Analog control input conductor - Humidity protection Highlights: Smoothly operating 3-phase - Degree of protection: IP 54 fan drive Backward-curved impeller Weight: 1.4 kg – – – DC centrifugal fans – DC axial fans – Material: Watts 24 16...28 34.7 181 RG 160-28/14 NTD 308 181 24 RG 160-28/14 NTDH 370 218 RG 160-28/18 NTD... RG 160-28/18 N/2 TDHHP* 59 34.7 308 181 444 261 °C Hours Hours -20...+60 55 000 / 35 000 92 500 — 2.0 800 7.5 64 4 200 16...28 7.5 64 4 200 -20...+60 55 000 / 35 000 92 500 24 16...28 7.8 101 5 000 -20...+60 50 000 / 32 500 85 000 48 38...57 -20...+70 55 000 / 27 500 92 500 48 36...60 -20...+65 40 000 / 22 500 67 500 — 2.0 800 7.5 59 4 200 8.5 159 6 000 ¿ ¡ ¡ ¬ ¿ ¡ √ Subject to change Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories AC centrifugal fans AC axial fans Models RG 160-28/14 NTD... and RG 160-28/18 NTD... are available in customer-specific, custom-developed variants only. The figures indicated are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. *The specific service life is valid when an external capacitor is wired between the positive and negative wires. Please note the wiring suggestion. Tin-p la ted 105 Representatives 59 308 RG 160-28/14 NTD... rpm-1 DC fans - specials / ACmaxx / EC fans Bel(A) Curve Power consumption VDC Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings VDC Service life L10 (Tmax) ebm-papst standard Sound power level Air flow m3/h 2016-01 Min. Max. Type Service life L10 (40 °C) ebm-papst standard Voltage range Min. Max. Nominal data Temperature range Nominal voltage cfm Series RG 160 NTD Nominal speed Air flow 1) Fiberglass-reinforced plastic Max. 930 m /h DC centrifugal fans 3 226 x 85 mm – Possible special versions: Scroll housing: GRP1) (See chapter DC fans - specials) Impeller: GRP1) - Speed signal Direction of air flow: Axial: Intake, - Go / NoGo alarm Centrifugal: Exhaust - Alarm with speed limit Direction of rotation: Clockwise, looking towards rotor - External temperature sensor Connection: via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64. Speed signal - PWM control input and control input AWG 22 - Analog control input Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Moisture protection Backward-curved RadiCal - Salt spray protection impeller - Degree of protection: IP 54 Weight: 1210 g – Material: – – – – – Bel(A) / RG 190-39/14/2 TDMLO 630 371 24 16...30 7.6 54 3 000 -20...+60 55 000 / 35 000 92 500 RG 190-39/14/2 TDMO 820 482 24 16...36 7.9 113 3 900 -20...+65 52 500 / 30 000 87 500 RG 190-39/18/2 TDMLO* 630 371 48 36...57 7.6 52 3 000 -20...+65 55 000 / 30 000 92 500 RG 190-39/18/2 TDMO 820 482 48 36...72 7.9 113 3 900 -20...+65 52 500 / 30 000 87 500 RG 190-39/18/2 TDO 930 547 48 36...72 8.3 140 4 400 -20...+65 40 000 / 22 500 67 500 Watts °C Hours Curve rpm-1 Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings VDC Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range cfm Temperature range Nominal voltage m3/h Nominal data Nominal speed Air flow Type Series RG 190 TD Power consumption Air flow 1) Fiberglass-reinforced plastic Hours ¿ ¡ ¿ ¡ ¬ Subject to change * On request Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, Standstill if control cable is interrupted. Tin-plated 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 106 Finger guards P. 249 Information 1100 m /h DC centrifugal fans – RadiCal 3 270 x 99 mm – – – – – – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Humidity protection - Salt spray protection - Degree of protection:IP 54 DC axial fans Scroll housing: GRP1) Impeller: GRP1) Direction of air flow: Axial: Intake, Centrifugal: Exhaust Direction of rotation: Clockwise, looking towards rotor Connection: via single wires AWG 18, 20 or AWG 22, TR 64. Speed signal and control input AWG 22 Highlights: Highly efficient and smoothly operating 3-phase fan drive Backward-curved impeller Weight: 1560 g – Material: DC centrifugal fans Max. -20...+55 55 000 / 40 000 92 500 7.5 101 3 000 -20...+55 55 000 / 40 000 92 500 VDC Bel(A) RG 220-43/14/2 TDMO 1100 647 24 16...36 RG 220-43/18/2 TDMO* 1100 647 48 36...72 DC fans - specials 3 000 VDC Curve 101 cfm Life expectancy L10IPC (40 °C) see page 17 Temperature range 7.5 m3/h Service life L10 (Tmax) ebm-papst standard Nominal speed Hours Type Nominal data Service life L10 (40 °C) ebm-papst standard Power consumption Hours Sound power level °C Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series RG 220 TD Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic ¿ ¿ Subject to change AC centrifugal fans 2 Tin-plated 1,75 500 in H O Pa AC axial fans ACmaxx / EC fans Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, Standstill if control cable is interrupted. Further types available on request. * On request 0 100 200 200 400 300 400 600 500 800 600 cfm 1000 m3/h Finger guards P. 249 Accessories 107 Representatives 0,25 100 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 2016-01 0,5 200 0,75 1,0 300 1,25 1,5 400 Max. 1450 m /h DC centrifugal fans – RadiCal 3 270 x 119 mm – Scroll housing: GRP1) Impeller: GRP1) Direction of air flow: Axial: Intake, Centrifugal: Exhaust Direction of rotation: Clockwise, looking towards rotor Connection: via single wires AWG 18, 20 or AWG 22, TR 64. Speed signal and control input AWG 22 Highlights: Highly efficient and smoothly operating 3-phase fan drive Backward-curved RadiCal impeller Weight: 1750 g Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Humidity protection - Salt spray protection - Degree of protection: IP 54 – Material: – – – – – / 1090 641 24 16...36 RG 225-55/18/2 TDMLO* 1090 641 48 RG 225-55/18/2 TDMO 1210 712 RG 225-55/18/2 TDO 1450 853 RG 225-55/14/2 TDMLO Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings Bel(A) Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range VDC Type Watts rpm-1 °C Hours Hours 7.4 80 2 500 -20...+65 52 500 / 30 000 87 500 36...72 7.4 80 2 500 -20...+65 52 500 / 30 000 87 500 48 36...72 7.9 116 2 800 -20...+55 55 000 / 40 000 92 500 48 36...60 8.1 192 3 300 -20...+40 30 000 / 30 000 50 000 Curve Temperature range Nominal voltage cfm Nominal data Nominal speed Air flow m3/h Series RG 225 TD Power consumption Air flow 1) Fiberglass-reinforced plastic ¿ ¿ ¡ ¬ Subject to change * On request Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, Standstill if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the positive and negative wires. Please note the wiring suggestion. Tin-plated 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 108 Finger guards P. 249 220 m /h Information Max. DC centrifugal fans 3 Ø 97 x 41 mm RET 97-25/14/2 TDP 220 129 24 16...32 RET 97-25/18/2 TDP 220 129 48 36...60 °C DC axial fans DC centrifugal fans Bel(A) Hours Hours -20...+60 80 000 / 50 000 135 000 -20...+60 80 000 / 50 000 135 000 DC fans - specials VDC Curve 6 000 VDC Life expectancy L10IPC (40 °C) see page 17 76 cfm Service life L10 (Tmax) ebm-papst standard 8.1 m3/h Service life L10 (40 °C) ebm-papst standard Nominal speed 6 000 Type Nominal data Temperature range Power consumption 77 Sound power level 8.1 Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series RET 97 TD Sintec sleeve bearings Ball bearings – Material: Impeller: Galvanized sheet steel – Possible special versions: (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64. Speed signal - PWM control input and control input AWG 22 - Analog control input – Highlights: Highly efficient and smoothly - Moisture protection operating 3-phase fan drive Forward-curved impeller Fan requires a scroll housing – Weight: 430 g ¿ ¿ Subject to change +1 Accessories 97 ø 58,3 7,95 + 1 109 Representatives 40,5 2016-01 Inlet rings from p. 252 24,4 M4 (4x) Air performance measured according to: ISO 5801. Installation category A, with ebm-papst scroll housing without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parametersmust be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions ø 47,1 310 +10 6 +1 Tin-plated AC centrifugal fans AC axial fans ACmaxx / EC fans Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, maximum speed if control cable is interrupted. To attain the specified service life, an external capacitor must be wired between the positive and negative wires. Please note the wiring suggestion. Max. 104 m /h DC centrifugal fans 3 Ø 104 x 25 mm – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: via single wires AWG 22, TR 64 - Internal temperature sensor – Highlights: Backward-curved impeller - PWM control input – Weight: 160 g - Analog control input - Moisture protection - Degree of protection: IP 54 / REF 100-11/12 86 50.6 12 8...15 REF 100-11/14 86 50.6 24 REF 100-11/18 REF 100-11/18 H Watts rpm-1 °C Hours Hours 6.3 7.5 5 400 -20...+75 80 000 / 30 000 135 000 16...30 6.3 7.5 5 400 -20...+75 80 000 / 30 000 135 000 86 50.6 48 36...60 6.3 8.2 5 400 -20...+75 80 000 / 30 000 135 000 104 61.2 48 36...56 6.9 14.8 6 700 -20...+70 67 500 / 32 500 115 000 Subject to change The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 127 x 127 mm. Cover plate 127 x 127 mm, with an air inlet opening Ø 70 mm, arranged concentrically to the impeller. 2016-01 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 110 ted 6 deep Tin-pla Curve Bel(A) Life expectancy L10IPC (40 °C) see page 17 VDC Service life L10 (Tmax) ebm-papst standard Sintec sleeve bearings Ball bearings VDC Service life L10 (40 °C) ebm-papst standard Sound power level m3/h Temperature range Voltage range Air flow Type Nominal data Nominal speed Nominal voltage cfm Series REF 100 Power consumption Air flow 1) Fiberglass-reinforced plastic ¿ ¿ ¿ ¡ Information 190 m /h DC centrifugal fans 3 Ø 101 x 52 mm DC centrifugal fans DC axial fans – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: via single wires AWG 22, TR 64 - Internal temperature sensor – Highlights: Backward-curved impeller - PWM control input – Weight: 305 g - Analog control input - Moisture protection 7.2 48 36...60 7.2 RER 101-36/12 NH 162 95 12 9...13.6 RER 101-36/12 NHH 190 112 12 RER 101-36/14 NHH 190 112 RER 101-36/18 NHH 190 112 °C Hours Hours -20...+70 65 000 / 32 500 110 000 6 000 -20...+70 60 000 / 30 000 102 500 22.5 6 050 -20...+70 60 000 / 30 000 102 500 19.4 5 850 -20...+70 60 000 / 30 000 102 500 DC fans - specials 18...27.2 Bel(A) ¡ ¿ ¿ ¿ ACmaxx / EC fans 24 VDC Curve 20.5 VDC Life expectancy L10IPC (40 °C) see page 17 7.2 cfm Service life L10 (Tmax) ebm-papst standard 9...13.6 m3/h Service life L10 (40 °C) ebm-papst standard Nominal speed 5 000 Type Nominal data Temperature range Power consumption 13.0 Sound power level 6.9 Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series RER 101 N Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic Subject to change Accessories 36,7 6,0 +- 0,2 7,0 +- 0,45 8,0 +- 0,55 50,25 +- 0,95 51,7 +- 0,9 111 2016-01 10 deep O 100 +- 0,5 O 60 +- 0,2 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions ted M 4 (3x) Tin-p la AC centrifugal fans AC axial fans The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 148 x 148 mm. Cover plate 148 x 148 mm, with an air inlet opening Ø 66 mm, arranged concentrically to the impeller. Representatives Max. Max. 390 m /h DC centrifugal fans 3 Ø 120 x 54 mm – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64. Speed signal - PWM control input and control input AWG 22 - Analog control input – Highlights: Highly efficient and smoothly - Moisture protection operating 3-phase fan drive Backward-curved impeller – Weight: 430 g / Watts rpm-1 °C Hours Hours RER 120-26/14/2 TDMP* 320 188 24 16...32 tbd 51 5 200 -20...+60 60 000 / 37 500 102 500 RER 120-26/14/2 TDP 377 222 24 16...32 8.2 78 6 100 -20...+60 55 000 / 35 000 92 500 RER 120-26/18/2 TDMP* 320 188 48 36...60 tbd 51 5 200 -20...+60 57 500 / 35 000 97 500 RER 120-26/18/2 TDP 390 230 48 36...60 8.3 92 6 300 -20...+60 50 000 / 30 000 85 000 Curve Bel(A) Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings VDC Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range cfm Temperature range Nominal voltage m3/h Nominal data Nominal speed Air flow Type Series RER 120 TD Power consumption Air flow 1) Fiberglass-reinforced plastic ¿ ¡ ¿ ¬ Subject to change * On request Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, maximum speed if control cable is interrupted. The specific service life is valid when an external capacitor is wired between the positive and negative wires. Please note the wiring suggestion. The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 140 x 140 mm. Cover plate 140 x 140 mm, with an air inlet opening Ø 94.4 mm, arranged concentrically to the impeller. 2016-01 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 112 Inlet rings from p. 252 Max. 8 deep Tin-plated Representatives 2016-01 113 Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information Max. 250 m /h DC centrifugal fans 3 Ø 120 mm – Material: Power consumption Input current Sound pressure level Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) °C R1G 120 M1G 045-BE A 24 16-28 250 4060 26 1.20 62 -25..+50 p. 259 / G) R1G 120 M1G 045-BE A 48 36-57 250 4060 26 0.60 62 -25..+50 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – – Impeller: PA 6.6 plastic, fiberglass-reinforced Rotor: Galvanized Number of blades: 9 Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 20 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 4520 36 65 — A 2’ 4500 36 64 27 A 3’ 4540 36 61 45 A 4’ 4750 32 64 39 A 1 4060 26 62 — A 2 4000 26 61 27 A 3 4050 26 58 45 A 4 4200 23 61 39 A 5 3270 14 56 — A 6 3250 14 55 27 A 7 3280 14 53 45 A 8 3400 13 56 39 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 114 n rpm-1 Information DC axial fans See connection diagram p. 259 Axial EN 60950-1 EAC DC centrifugal fans Technical features: Cable exit: Conformity with standard(s): Approvals: kg Inlet ring (long) R1G 120-AD13 -02 0.5 96120-2-4013 R1G 120-AD11 -02 0.5 96120-2-4013 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal fans AC axial fans Clearance for screw max. 4 mm Inlet rings from p. 253 Connection diagrams P. 259 115 2016-01 Accessories AC centrifugal fans Wire end splices Representatives – – – – Max. 166 m /h DC centrifugal fans 3 Ø 138 x 35 mm – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: via single wires AWG 22, TR 64 - Internal temperature sensor – Highlights: Backward-curved impeller - PWM control input – Weight: 320 g - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 / IP 68 24 12...28 7.0 48 36...56 5.7 VDC Bel(A) RER 125-19/12 N 110 64.7 12 7...15 RER 125-19/14 N 110 64.7 24 RER 125-19/14 NH 166 97.7 RER 125-19/18 N 110 64.7 °C Curve 4.3 VDC Life expectancy L10IPC (40 °C) see page 17 5.7 cfm Service life L10 (Tmax) ebm-papst standard 12...28 m3/h Service life L10 (40 °C) ebm-papst standard Nominal speed 2 650 Type Nominal data Temperature range Power consumption 4.6 Sound power level 5.7 Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series RER 125 N Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic Hours Hours -30...+75 62 500 / 27 500 105 000 2 650 -30...+75 62 500 / 27 500 105 000 13.0 4 000 -20...+70 55 000 / 27 500 92 500 4.2 2 650 -30...+75 62 500 / 27 500 105 000 Subject to change 5 deep The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 220 x 220 mm. Cover plate 220 x 220 mm, with an air inlet opening Ø 86 mm, arranged concentrically to the impeller. 2016-01 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 116 Tin-plated ¿ ¿ ¡ ¿ Information 565 m /h DC centrifugal fans 3 Ø 133 x 91 mm DC centrifugal fans DC axial fans – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64. Speed signal - PWM control input and control input AWG 22 - Analog control input – Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Moisture protection Backward-curved impeller - Salt spray protection – Weight: 890 g - Degree of protection: IP 54 460 271 24 16...30 RER 133-41/14/2 TDP* 565 332 24 16...36 RER 133-41/18/2 TDMP* 460 271 48 RER 133-41/18/2 TDP 332 48 565 rpm-1 °C Hours Hours tbd 58 5 000 -20...+65 72 500 / 40 000 122 500 tbd 90 6 000 -20...+65 70 000 / 37 500 117 500 36...57 tbd 50 5 000 -20...+65 72 500 / 40 000 122 500 36...72 8.2 87 6 000 -20...+65 70 000 / 37 500 117 500 DC fans - specials RER 133-41/14/2 TDMP Watts ¿ ¡ ¿ ¡ ACmaxx / EC fans / Curve Bel(A) Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings VDC Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range cfm Temperature range Nominal voltage m3/h Nominal data Nominal speed Air flow Type Series RER 133 TD Power consumption Air flow 1) Fiberglass-reinforced plastic Subject to change Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, maximum speed if control cable is interrupted. AC centrifugal fans AC axial fans The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 140 x 140 mm. Cover plate 140 x 140 mm, with an air inlet opening Ø 87 mm, arranged concentrically to the impeller. Inlet rings from p. 252 117 2016-01 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories Tin-plated Max. 8 deep * On request Representatives Max. Max. 255 m /h DC centrifugal fans 3 Ø 165 x 51 mm – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Counterclockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: via single wires AWG 22, TR 64 - Internal temperature sensor – Highlights: Backward-curved impeller - PWM control input – Weight: 590 g - Analog control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 28...60 6.4 19.0 VDC Bel(A) RER 160-28/12 N 255 150 12 7...14 RER 160-28/14 N 255 150 24 RER 160-28/18 N 255 150 48 °C Hours Hours -20...+70 75 000 / 37 500 127 500 3 000 -20...+70 75 000 / 37 500 127 500 3 000 -20...+70 75 000 / 37 500 127 500 Curve 19.0 VDC Life expectancy L10IPC (40 °C) see page 17 6.4 cfm Service life L10 (Tmax) ebm-papst standard 12...28 m3/h Service life L10 (40 °C) ebm-papst standard Nominal speed 3 000 Type Nominal data Temperature range Power consumption 19.0 Sound power level 6.4 Voltage range rpm-1 Nominal voltage Watts Air flow / Air flow Series RER 160 N Sintec sleeve bearings Ball bearings 1) Fiberglass-reinforced plastic ¿ ¿ ¿ Subject to change The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 260 x 260 mm. Cover plate 260 x 260 mm, with an air inlet opening Ø 100 mm, arranged concentrically to the impeller. 2016-01 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 118 Inlet rings from p. 252 Max. 8 deep Tin-plated 360 m /h Information Max. DC centrifugal fans 3 Ø 165 x 51 mm DC centrifugal fans DC axial fans – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: via single wires AWG 22, TR 64 - Internal temperature sensor – Highlights: Highly efficient and smoothly - PWM control input operating 3-phase fan drive - Analog control input Backward-curved impeller - Humidity protection – Weight: 590 g - Degree of protection: IP 54 RER 160-28/14 NTD… 360 211 24 16...28 RER 160-28/18 NTD… 360 211 48 38...57 Watts rpm-1 °C Hours 7.4 51 4 200 -20...+60 55 000 / 27 500 92 500 7.4 48 4 200 -20...+70 55 000 / 27 500 92 500 Hours DC fans - specials / Curve Bel(A) Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings VDC Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range cfm Temperature range Nominal voltage m3/h Nominal data Nominal speed Air flow Type Series RER 160 NTD Power consumption Air flow 1) Fiberglass-reinforced plastic ¡ ¿ Subject to change ACmaxx / EC fans Model RER 160-28/18 NTD... is available in customer-specific, custom-developed variant only. The figures indicated are technically feasible benchmark values. The fans can be specially adapted to your application with signal outputs and control inputs. * The specific service life is valid when an external capacitor is wired between the positive and negative wires. Please note the wiring suggestion. AC centrifugal fans AC axial fans The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 260 x 260 mm. Cover plate 260 x 260 mm, with an air inlet opening Ø 100 mm, arranged concentrically to the impeller. Representatives 119 2016-01 Inlet rings from p. 252 Max. 8 deep Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories Tin-plated Max. 800 m /h DC centrifugal fans 3 Ø 175 x 55 mm REF 175-30/18/2 TDP 800 470 48 36 ... 72 8.3 / Watts rpm-1 144 4 400 °C -20...+60 Hours Hours 65 000 / 37 500 110 000 Curve Bel(A) Life expectancy L10IPC (40 °C) see page 17 VDC Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range cfm Temperature range Nominal voltage m3/h Nominal speed Air flow Type Nominal data Power consumption Air flow Series RER 175 TD Sintec sleeve bearings Ball bearings – Material: Impeller: Galvanized sheet steel – Possible special versions: (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64. Speed signal - PWM control input and control input AWG 22 - Analog control input – Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Humidity protection Backward-curved impeller - Degree of protection: IP 54 – Weight: 930 g ¿ Subject to change Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, maximum speed if control cable is interrupted. The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 180 x 180 mm. Cover plate 180 x 180 mm, with an air inlet opening Ø 125.5 mm, arranged concentrically to the impeller. 2016-01 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 120 Inlet rings from p. 252 Max. 8 deep Tin-plated Information 980 m /h DC centrifugal fans 3 Ø 175 x 69 mm DC centrifugal fans DC axial fans – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: Via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64, speed signal - PWM control input and control input AWG 22 - Analog control input – Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Moisture protection Backward-curved impeller - Salt spray protection – Weight: 775 g - Degree of protection: IP 54 RER 175-42/14/2 TDMLP 600 353 24 16...30 RER 175-42/14/2 TDMP 865 509 24 16...36 RER 175-42/18/2 TDMLP 600 353 48 RER 175-42/18/2 TDMP* 865 509 RER 175-42/18/2 TDP 980 577 rpm-1 °C Hours Hours 7.3 48 3 400 -20...+65 72 500 / 40 000 122 500 8.2 110 4 800 -20...+65 70 000 / 40 000 117 500 36...57 7.3 46 3 400 -20...+65 72 500 / 40 000 122 500 48 36...72 8.2 110 4 800 -20...+65 70 000 / 40 000 117 500 48 36...72 8.5 166 5 400 -20...+65 60 000 / 32 500 102 500 Curve Watts DC fans - specials / ¿ ¡ ¿ ¡ ¬ ACmaxx / EC fans Bel(A) Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings VDC Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range cfm Temperature range Nominal voltage m3/h Nominal data Nominal speed Air flow Type Series RER 175 TD Power consumption Air flow 1) Fiberglass-reinforced plastic Subject to change Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, maximum speed if control cable is interrupted. Max. 8 deep M4 (4x) 6,8+ 0,8 42 69 ±1 121 2016-01 Inlet rings from p. 252 ø58 + 0,1 ø 72 +0,3 ø175 +0,5 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories 425 +10 Tin-plated AC centrifugal fans AC axial fans The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 180 x 180 mm. Cover plate 180 x 180 mm, with an air inlet opening Ø 125.5 mm, arranged concentrically to the impeller. 6 +1 * On request Representatives Max. Max. 970 m /h DC centrifugal fans – RadiCal 3 Ø 190 x 69 mm – Material: Impeller: GRP1) – Direction of air flow: Axial: Intake, Centrifugal: Exhaust – Direction of rotation: Clockwise, looking towards rotor – Connection: Via single wires AWG 18, 20 or AWG 22, TR 64, speed signal and control input AWG 22 – Highlights: Highly efficient and smoothly operating 3-phase fan drive Backward-curved RadiCal impeller – Weight: 870 g – Possible special versions: (See chapter DC fans - specials) - Speed signal - Go / NoGo alarm - Alarm with speed limit - External temperature sensor - Internal temperature sensor - PWM control input - Analog control input - Multi-option control input - Moisture protection - Salt spray protection - Degree of protection: IP 54 Sound power level Sintec sleeve bearings Ball bearings Power consumption Nominal speed VDC VDC Bel(A) / Watts rpm-1 RER 190-39/14/2 TDMLO 650 382 24 16...30 7.6 58 3 000 -20...+60 55 000 / 35 000 92 500 RER 190-39/14/2 TDMO 860 506 24 16...36 7.9 110 3 900 -20...+65 52 500 / 30 000 87 500 RER 190-39/18/2 TDMLO* 650 382 48 36...57 7.6 56 3 000 -20...+65 55 000 / 30 000 92 500 RER 190-39/18/2 TDMO* 860 506 48 36...72 7.9 105 3 900 -20...+65 52 500 / 30 000 87 500 RER 190-39/18/2 TDO 970 571 48 36...72 8.3 148 4 400 -20...+65 40 000 / 22 500 67 500 °C Hours Curve Life expectancy L10IPC (40 °C) see page 17 Voltage range cfm Service life L10 (Tmax) ebm-papst standard Nominal voltage m3/h Nominal data Service life L10 (40 °C) ebm-papst standard Air flow Type Series RER 190 TD Temperature range Air flow 1) Fiberglass-reinforced plastic Hours ¿ ¡ ¿ ¡ ¬ Subject to change * On request Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, Standstill if control cable is interrupted. 2016-01 122 Inlet rings from p. 252 39 69 +1 6,5 +1 190 + 0,3 72 +0,3 Max. 8 deep 58 + 0,1 M4 (4x) Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m; Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 425 +10 Tin-plated 6 +1 The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 195 x 195 mm. Cover plate 195 x 195 mm, with an air inlet opening Ø 125.5 mm, arranged concentrically to the impeller. Representatives 2016-01 123 Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information Max. 930 m /h DC centrifugal fans – RadiCal 3 Ø 190 mm – Material: Power consumption Input current Sound pressure level Admissible amb. temp. Type Motor m3/h rpm-1 W A dB(A) °C R3G 190 M3G 074-CF A 24 16-28 880 4570 180 7.50 76 -25..+60 p. 262 / J5) R3G 190 M3G 074-CF B 48 36-57 930 4800 192 4.00 76 -25..+60 p. 262 / J5) Technical features and connection diagram Nominal speed VDC Curve Nominal data Nominal voltage range VDC Nominal voltage Air flow – – – – – – – – Impeller: PA plastic Rotor: Painted black Number of blades: 7 Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 44, depending on installation and position Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: n rpm-1 Ped W I A L WA dB(A) B A A 1 4570 180 7.50 84 A 2 4525 188 7.83 79 A 3 4435 199 8.34 77 A 4 4520 191 7.96 81 B 1 4800 192 4.00 84 B 2 4690 212 4.41 80 B 3 4640 221 4.60 79 B 4 4740 205 4.28 81 2016-01 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 124 Information DC axial fans See connection diagram p. 262 Variable EN 60950-1 EAC DC centrifugal fans Technical features: Cable exit: Conformity with standard(s): Approvals: kg Inlet ring R3G 190-RN38 -01 1.9 09576-2-4013 R3G 190-RN99 -02 1.9 09576-2-4013 Clearance for screw max. 12 - 14 mm Accessories AC centrifugal fans AC axial fans Accessory part: Inlet ring 09576-2-4013 not included in the standard scope of delivery ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal fans – – – – Connection diagrams P. 262 125 Representatives Inlet rings P. 254 2016-01 PVC AWG 16 cable, 4 x crimped ferrules Max. 1215 m /h DC centrifugal fans – RadiCal 3 Ø 220 mm – Material: Power consumption Input current Sound pressure level Admissible amb. temp. Type Motor m3/h rpm-1 W A dB(A) °C R3G 220 M3G 074-CF A 24 16-28 1200 3460 157 6.50 73 -25...+60 p. 262 / J5) R3G 220 M3G 074-CF B 48 36-57 1215 3510 160 3.40 73 -25...+60 p. 262 / J5) Technical features and connection diagram Nominal speed VDC Curve Nominal data Nominal voltage range VDC Nominal voltage Air flow – – – – – – – – Impeller: PA plastic Rotor: Painted black Number of blades: 7 Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 44, depending on installation and position Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: B A 2016-01 Ped W I A L WA dB(A) A 1 3460 157 6.50 81 A 2 3420 171 7.11 77 A 3 3360 182 7.59 74 A 4 3455 168 6.97 79 B 1 3510 160 3.40 81 B 2 3450 168 3.50 77 B 3 3385 178 3.71 74 B 4 3460 167 3.47 79 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 126 n rpm-1 Information DC axial fans See connection diagram p. 262 Variable EN 60950-1 EAC DC centrifugal fans Technical features: Cable exit: Conformity with standard(s): Approvals: kg Inlet ring R3G 220-RN12 -01 1.9 09609-2-4013 R3G 220-RNB6 -02 1.9 09609-2-4013 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal fans – – – – Accessory part: Inlet ring 09609-2-4013 not included in the standard scope of delivery Accessories AC centrifugal fans AC axial fans Clearance for screw max. 12 - 14 mm Connection diagrams P. 262 127 Representatives Inlet rings from p. 253 2016-01 PVC AWG 16 cable, 4 x crimped ferrules Max. 1250 m /h DC centrifugal fans – RadiCal 3 Ø 221 x 71 mm – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: Via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64, speed signal - PWM control input and control input AWG 22 - Analog control input – Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Humidity protection Backward-curved impeller - Salt spray protection – Weight: 940 g - Degree of protection: IP 54 RER 220-43/14/2 TDMO* 1063 625 24 16...36 RER 220-43/18/2 TDMO 1063 625 48 RER 220-43/18/2 TDO 1250 735 48 Subject to change * On request Watts rpm-1 °C Hours Hours tbd 110 3 000 -20...+55 65 000 / 45 000 110 000 36...72 tbd 110 3 000 -20...+55 65 000 / 45 000 110 000 36...72 tbd 160 3 500 -20...+55 60 000 / 42 500 102 500 Curve / Life expectancy L10IPC (40 °C) see page 17 Sintec sleeve bearings Ball bearings Bel(A) Service life L10 (Tmax) ebm-papst standard Sound power level VDC Service life L10 (40 °C) ebm-papst standard Voltage range VDC Type Temperature range Nominal voltage cfm Nominal data Nominal speed Air flow m3/h Series RER 220 TD Power consumption Air flow 1) Fiberglass-reinforced plastic ¿ ¿ ¡ Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, Standstill if control cable is interrupted. The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 230 x 230 mm. Cover plate 230 x 230 mm, with an air inlet opening Ø 155 mm, arranged concentrically to the impeller. 2016-01 Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 128 Inlet rings from p. 253 Max. 8 deep Tin-plated 1600 m /h Information Max. DC centrifugal fans 3 Ø 225 x 99 mm DC centrifugal fans DC axial fans – Possible special versions: – Material: Impeller: GRP1) (See chapter DC fans - specials) – Direction of air flow: Axial: Intake, - Speed signal Centrifugal: Exhaust - Go / NoGo alarm – Direction of rotation: Clockwise, - Alarm with speed limit looking towards rotor - External temperature sensor – Connection: Via single wires AWG 18, 20 or - Internal temperature sensor AWG 22, TR 64, speed signal - PWM control input and control input AWG 22 - Analog control input – Highlights: Highly efficient and smoothly - Multi-option control input operating 3-phase fan drive - Humidity protection Backward-curved impeller - Salt spray protection – Weight: 1030 g - Degree of protection: IP 54 Sintec sleeve bearings Ball bearings Power consumption Nominal speed Temperature range VDC Bel(A) / Watts rpm-1 °C RER 225-63/18/2 TDMLO 1190 700 48 36...72 7.2 77 2 500 RER 225-63/18/2 TDMO 1340 789 48 36...72 7.8 108 2 800 RER 225-63/18/2 TDO 1600 941 48 36...72 8.1 163 3 300 -20...+55 Hours Hours -20...+55 70 000 / 50 000 122 500 -20...+55 55 000 / 40 000 92 500 52 500 / 37 500 87 500 DC fans - specials Sound power level VDC Curve Voltage range cfm Life expectancy L10IPC (40 °C) see page 17 Nominal voltage m3/h Nominal data Service life L10 (Tmax) ebm-papst standard Air flow Type Series RER 225 TD Service life L10 (40 °C) ebm-papst standard Air flow 1) Fiberglass-reinforced plastic ¿ ¡ ¬ ACmaxx / EC fans Subject to change Speed control range from 800 rpm-1 at 7% PWM up to nominal speed at > 90% PWM. Standstill at 0% PWM, Type O: Standstill if control cable is interrupted. Type P: Maximum speed if control cable is interrupted. AC centrifugal fans AC axial fans The air flow and sound level of the centrifugal fans without external housing depend on their individual installation conditions. The stated air flow and sound level were recorded under the following measurement parameters: Centrifugal fan mounted on a foundation plate 230 x 230 mm. Cover plate 230 x 230 mm, with an air inlet opening Ø 146 mm, arranged concentrically to the impeller. Representatives 129 2016-01 Inlet rings from p. 252 Max. 8 deep Air performance measured according to: ISO 5801. Installation category A, with ebm-papst inlet ring without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a distance of 2 m. Sound pressure level LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions Accessories Tin-plated Max. 1340 m /h DC centrifugal fans – RadiCal 3 Ø 225 mm – Material: Power consumption Input current Sound pressure level Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) °C R3G 225 M3G 074-CF A 24 16-28 1300 3270 205 8.50 75 -25...+60 p. 262 / J5) R3G 225 M3G 074-CF B 48 36-57 1340 3400 230 4.80 73 -25...+60 p. 262 / J5) Technical features and connection diagram Nominal speed Type Nominal voltage Nominal data Nominal voltage range VDC Curve Air flow – – – – – – – – Impeller: PA plastic Rotor: Painted black Number of blades: 7 Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 44, depending on installation and position Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: B A 2016-01 Ped W I A L WA dB(A) A 1 3270 205 8.50 81 A 2 3200 208 8.66 78 A 3 3185 213 8.88 74 A 4 3260 194 8.02 77 B 1 3400 230 4.80 83 B 2 3440 257 5.35 80 B 3 3435 260 5.43 76 B 4 3500 239 4.97 78 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 130 n rpm-1 Information DC axial fans See connection diagram p. 262 Variable EN 60950-1 EAC DC centrifugal fans Technical features: Cable exit: Conformity with standard(s): Approvals: kg Inlet ring R3G 225-RN28 -01 2.1 96358-2-4013 R3G 225-RN18 -02 2.1 96358-2-4013 Clearance for screw max. 12 - 14 mm Accessories AC centrifugal fans AC axial fans Accessory part: Inlet ring 96358-2-4013 not included in the standard scope of delivery ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal fans – – – – Connection diagrams P. 262 131 Representatives Inlet rings from p. 254 2016-01 PVC AWG 16 cable, 4 x crimped ferrules Max. 1640 m /h DC centrifugal fans – RadiCal 3 Ø 250 mm – Material: Power consumption Input current Sound pressure level Admissible amb. temp. Type Motor m3/h rpm-1 W A dB(A) °C R3G 250 M3G 074-CF A 24 16-28 1505 2850 175 7.20 73 -25...+60 p. 262 / J5) R3G 250 M3G 074-CF B 48 36-57 1640 3100 230 4.80 73 -25...+60 p. 262 / J5) Technical features and connection diagram Nominal speed VDC Curve Nominal data Nominal voltage range VDC Nominal voltage Air flow – – – – – – – – Impeller: PA plastic Rotor: Painted black Number of blades: 7 Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 44, depending on installation and position Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: n rpm-1 Ped W I A L WA dB(A) B A A 1 2850 175 7.20 81 A 2 3075 260 10.80 77 A 3 3035 276 11.45 75 A 4 3095 256 10.66 75 B 1 3100 230 4.80 81 B 2 3065 249 5.20 77 B 3 3025 266 5.55 75 B 4 3090 244 5.09 78 2016-01 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 132 Information DC axial fans See connection diagram p. 262 Variable EN 60950-1 EAC DC centrifugal fans Technical features: Cable exit: Conformity with standard(s): Approvals: kg Inlet ring R3G 250-RN46 -01 2.1 96359-2-4013 R3G 250-RNB5 -02 2.1 96359-2-4013 Clearance for screw max. 12 - 14 mm Accessories AC centrifugal fans AC axial fans Accessory part: Inlet ring 96359-2-4013 not included in the standard scope of delivery ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal fans – – – – Connection diagrams P. 262 133 Representatives Inlet rings from p. 254 2016-01 PVC AWG 16 cable, 4 x crimped ferrules Max. 2190 m /h DC centrifugal fans – RadiCal 3 Ø 280 mm – Material: Power consumption Input current Sound pressure level Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) °C R3G 280 M3G 074-CF A 24 16-28 2190 1900 142 5.90 67 -25...+60 p. 262 / J5) R3G 280 M3G 074-CF B 48 36-57 2160 1910 140 2.90 67 -25...+60 p. 262 / J5) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – – Impeller: PP plastic Rotor: Painted black Number of blades: 6 Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 44, depending on installation and position Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: n rpm-1 Ped W I A L WA dB(A) A B A 1 1900 142 5.90 74 A 2 1870 162 6.76 67 A 3 1840 173 7.21 64 A 4 1905 153 6.36 68 B 1 1910 140 2.90 74 B 2 1845 158 3.30 67 B 3 1830 163 3.40 64 B 4 1900 141 2.93 68 2016-01 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 134 Information DC axial fans See connection diagram p. 262 Variable EN 60950-1 EAC DC centrifugal fans Technical features: Cable exit: Conformity with standard(s): Approvals: kg Inlet ring R3G 280-RN30 -01 2.4 28000-2-4013 R3G 280-RNB1 -02 2.4 28000-2-4013 Clearance for screw max. 12 - 14 mm Accessories AC centrifugal fans AC axial fans Accessory part: Inlet ring 28000-2-4013 not included in the standard scope of delivery ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal fans – – – – Connection diagrams P. 262 135 Representatives Inlet rings from p. 254 2016-01 PVC AWG 16 cable, 4 x crimped ferrules Max. 2380 m /h DC centrifugal fans – RadiCal 3 Ø 310 mm – Material: Power consumption Input current Sound pressure level Admissible amb. temp. Type Motor m3/h rpm-1 W A dB(A) °C R3G 310 M3G 074-CF A 24 16-28 2310 1580 108 4.50 64 -25...+60 p. 262 / J5) R3G 310 M3G 074-CF B 48 36-57 2380 1620 123 2.60 64 -25...+60 p. 262 / J5) Technical features and connection diagram Nominal speed VDC Curve Nominal data Nominal voltage range VDC Nominal voltage Air flow – – – – – – – – Impeller: PP plastic Rotor: Painted black Number of blades: 6 Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 44, depending on installation and position Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: n rpm-1 Ped W I A L WA dB(A) B A A 1 1580 108 4.50 70 A 2 1540 145 6.03 67 A 3 1520 152 6.34 63 A 4 1550 143 5.95 65 B 1 1620 123 2.60 70 B 2 1570 147 3.07 66 B 3 1545 156 3.26 63 B 4 1580 144 3.01 66 2016-01 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst inlet ring without contact protection. Suctionside noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 136 Information DC axial fans See connection diagram p. 262 Variable EN 60950-1 EAC DC centrifugal fans Technical features: Cable exit: Conformity with standard(s): Approvals: kg Inlet ring R3G 310-RN99 -01 2.8 31000-2-4013 R3G 310-RN98 -02 2.8 31000-2-4013 Clearance for screw max. 12 - 14 mm Accessories AC centrifugal fans AC axial fans Accessory part: Inlet ring 31000-2-4013 not included in the standard scope of delivery ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal fans – – – – Connection diagrams P. 262 137 Representatives Inlet rings from p. 254 2016-01 PVC AWG 16 cable, 4 x crimped ferrules Max. 155 m /h DC tangential fans 3 201...413 x 50 x 48 mm – Possible special versions: Housing: Aluminum (See chapter DC fans - specials) Housing side parts: Plastic - Speed signal Impeller: Aluminum - Moisture protection Direction of air flow: See photo Connection: via single wires AWG 24, TR 64 Highlights: Motor with ball bearing system Impeller retaining plate with sleeve bearing Weight: 235 / 290 / 380 / 415 g – – – Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power consumption Temperature range VDC VDC db(A) Bel(A) / Watts °C Hours QG 030-148/12 75 44 12 8...14 49 5.7 / 6.2 -20...+60 30 000 / 20 000 50 000 QG 030-198/12 100 59 12 8...14 51 5.8 / 8,0 -20...+60 30 000 / 20 000 50 000 QG 030-303/12 140 82 12 8...14 51 5.8 / 8.7 -20...+60 30 000 / 20 000 50 000 QG 030-353/12 155 91 12 8...14 51 5.9 / 9.6 -20...+60 30 000 / 20 000 50 000 QG 030-148/14 75 44 24 16...28 49 5.7 / 6.2 -20...+60 30 000 / 20 000 50 000 QG 030-198/14 100 59 24 16...28 51 5.8 / 8.0 -20...+60 30 000 / 20 000 50 000 QG 030-303/14 140 82 24 16...28 51 5.8 / 8.7 -20...+60 30 000 / 20 000 50 000 QG 030-353/14 155 91 24 16...28 51 5.9 / 9.6 -20...+60 30 000 / 20 000 50 000 Type Life expectancy L10IPC (40 °C) see page 17 Nominal voltage cfm Nominal data Service life L10 (Tmax) ebm-papst standard Air flow m3/h Series QG 030 Service life L10 (40 °C) ebm-papst standard Air flow – Hours Curve – Material: ¿ ¡ ¬ √ ¿ ¡ ¬ √ Subject to change The values for service life were recorded with the fan installed horizontally. L L1 Mass QG 030-148/ .. Type Dimension: 203.4 +1.5 148 235 g QG 030-198/ .. 260.4 +1.5 198 290 g QG 030-303/ .. 365.4 +1.5 303 380 g QG 030-353/ .. 415.4 +1.5 353 415 g Tangential fans are suitable only for operation with high air flow and low back-pressure. 2016-01 Air performance measured according to: ISO 5801. Installation category A, without contact protection. Noise: Total sound power level LWA ISO 103002 measured on a hemisphere with a radius of 2 m. Sound pressure level LpA measured at 1 m distance to fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 138 Pocket for square nut M3 DIN 562, flat (6x) Representatives 2016-01 139 Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans DC fans - specials DC centrifugal fans DC axial fans Information Max. 95 m /h DC centrifugal fans and blowers 3 Ø 85 mm – Material: Admissible amb. temp. m3/h rpm-1 W A dB(A) Pa °C 16-28 95 2850 14 0.64 57 0 -25...+60 p. 259 / G) 36-57 95 2850 14 0.32 57 0 -25...+60 p. 259 / G) VDC VDC A 24 A 48 Technical features and connection diagram Min. back-pressure M1G 045-BE Sound pressure level *1G 085 Input current M1G 045-BE Power consumption *1G 085 Nominal speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – – – – – – – Housing: Die-cast aluminum Impeller: Hot-dip galvanized sheet steel Rotor: Galvanized Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 22 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 3180 19 59 — A 2’ 3300 16 57 28 A 3’ 3500 15 57 32 A 4’ 3800 12 57 37 A 1 2850 14 57 — A 2 3000 12 55 28 A 3 3180 11 55 32 A 4 3400 9 54 37 A 5 1890 5 46 — A 6 1970 4 44 25 A 7 2070 4 44 30 A 8 2170 3 42 33 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 140 n rpm-1 Information DC centrifugal fans DC axial fans See connection diagram p. 259 Axial EN 60950-1 EAC kg Centrifugal blowers with flange kg R1G 085-AB05 -01 0.5 G1G 085-AB05 -01 0.8 R1G 085-AB07 -01 0.5 G1G 085-AB07 -01 0.8 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal blowers Technical features: Cable exit: Conformity with standard(s): Approvals: Weight centrifugal fans AC centrifugal fans AC axial fans Clearance for screw max. 4 mm Finger guards from p. 247 Inlet rings from p. 253 Connection diagrams P. 259 141 Representatives Accessories Wire end splices 2016-01 – – – – Max. 95 m /h DC centrifugal fans and blowers 3 Ø 97 mm – Material: Admissible amb. temp. m3/h rpm-1 W A dB(A) Pa °C 16-28 95 2650 16 0.75 59 0 -25...+60 p. 259 / G) 36-57 95 2650 16 0.38 59 0 -25...+60 p. 259 / G) VDC VDC A 24 A 48 Technical features and connection diagram Min. back-pressure M1G 045-BE Sound pressure level *1G 097 Input current M1G 045-BE Power consumption *1G 097 Nominal speed Motor Air flow Type Nominal voltage range Nominal data Nominal voltage Curve – – – – – – – Housing: Hot-dip galvanized sheet steel Impeller: Hot-dip galvanized sheet steel Rotor: Galvanized Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 22 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 2920 22 62 — A 2’ 3030 21 61 41 A 3’ 3300 17 59 48 A 4’ 3700 13 58 48 A 1 2650 16 59 — A 2 2730 15 58 41 A 3 2960 13 56 48 A 4 3290 10 55 48 A 5 1615 4 45 — A 6 1650 4 45 38 A 7 1745 4 43 46 A 8 1880 3 42 47 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 142 n rpm-1 Information DC centrifugal fans DC axial fans See connection diagram p. 259 Axial EN 60950-1 EAC kg Centrifugal blowers with flange kg R1G 097-AA05 -01 0.5 G1G 097-AA05 -01 0.8 R1G 097-AA07 -01 0.5 G1G 097-AA07 -01 0.8 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal blowers Technical features: Cable exit: Conformity with standard(s): Approvals: Weight centrifugal fans AC centrifugal fans AC axial fans Clearance for screw max. 4 mm Finger guards from p. 242 Inlet rings from p. 253 Connection diagrams P. 259 143 Representatives Accessories Wire end splices 2016-01 – – – – Max. 200 m /h DC centrifugal fans and blowers 3 Ø 108 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C *1G 108 M1G 055-BD A 24 16-28 200 3000 42 2.00 65 0 -25...+60 p. 259 / G) *1G 108 M1G 055-BD .A 48 36-57 200 3000 42 1.00 65 0 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – Housing: Die-cast aluminum Impeller: Hot-dip galvanized sheet steel Rotor: Painted black Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 22 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 3230 55 67 — A 2’ 3410 52 66 33 A 3’ 3800 43 65 41 A 4’ 4100 35 64 33 A 1 3000 42 65 — A 2 3140 40 64 33 A 3 3420 32 63 41 A 4 3690 26 63 33 A 5 2300 20 61 — A 6 2380 17 58 33 A 7 2550 14 55 41 A 8 2720 11 55 33 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 144 n rpm-1 Information DC centrifugal fans DC axial fans See connection diagram p. 259 Axial I EN 60950-1 A (24 VDC) UL, CSA, A (48 VDC) CCC kg Centrifugal blowers with flange kg R1G 108-AB17 -02 0.7 G1G 108-AB17 -02 1.4 R1G 108-AB41 -02 0.7 G1G 108-AB41 -02 1.4 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal blowers Technical features: Cable exit: Protection class: Conformity with standard(s): Approvals: Weight centrifugal fans AC centrifugal fans AC axial fans Clearance for screw max. 6 mm Finger guards from p. 247 Inlet rings from p. 253 Air filter P. 254 Connection diagrams P. 259 145 Representatives Accessories Wire end splices 2016-01 – – – – – Max. 255 m /h DC centrifugal fans and blowers 3 Ø 120 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C *1G 120 M1G 055-BD A 24 16-28 255 2200 40 1.90 62 0 -25...+60 p. 259 / G) *1G 120 M1G 055-BD A 48 36-57 255 2200 40 0.95 62 0 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – Housing: Die-cast aluminum Impeller: Hot-dip galvanized sheet steel Rotor: Galvanized Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 22 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 2410 50 63 — A 2’ 2620 47 62 58 A 3’ 2870 44 61 60 A 4’ 3200 36 62 55 A 1 2200 40 62 — A 2 2410 36 60 59 A 3 2600 32 58 62 A 4 2880 25 58 55 A 5 1870 24 55 — A 6 1990 21 54 58 A 7 2100 18 53 61 A 8 2310 14 54 54 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 146 n rpm-1 Information kg Centrifugal blowers with flange kg R1G 120-AB67 -02 0.8 G1G 120-AB67 -02 1.6 R1G 120-AB71 -02 0.8 G1G 120-AB71 -02 1.6 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal blowers DC centrifugal fans DC axial fans Technical features: See connection diagram p. 259 Cable exit: Axial Protection class: I Conformity with standard(s): EN 60950-1 A (24 VDC) UL, CSA, A (48 VDC) CCC Approvals: Weight centrifugal fans AC centrifugal fans AC axial fans Clearance for screw max. 6 mm Finger guards from p. 247 Inlet rings from p. 253 Air filter P. 254 Connection diagrams P. 259 147 Representatives Accessories Wire end splices 2016-01 – – – – – Max. 225 m /h DC centrifugal fans and blowers 3 Ø 133 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C *1G 133 M1G 055-BD A 24 16-28 225 2000 40 2.20 64 0 -25...+60 p. 259 / G) *1G 133 M1G 055-BD A 48 36-57 225 2000 40 1.10 64 0 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – Housing: Hot-dip galvanized sheet steel Impeller: Hot-dip galvanized sheet steel Rotor: Galvanized Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 22 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 2170 57 66 — A 2’ 2410 51 66 47 A 3’ 2750 44 64 49 A 4’ 3200 36 66 32 A 1 2000 45 64 — A 2 2230 40 64 49 A 3 2540 35 62 51 A 4 2920 27 63 33 A 5 1750 28 60 — A 6 1910 24 59 50 A 7 2120 20 58 53 A 8 2370 15 59 35 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 148 n rpm-1 Information DC centrifugal fans DC axial fans See connection diagram p. 259 Lateral I EN 60950-1 A (24 VDC) UL, CSA, A (48 VDC) CCC kg Centrifugal blowers with flange kg R1G 133-AE19 -02 0.7 G1G 133-DE19 -02 1.3 R1G 133-AE03 -02 0.7 G1G 133-DE03 -02 1.3 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal blowers Technical features: Cable exit: Protection class: Conformity with standard(s): Approvals: Weight centrifugal fans AC axial fans Clearance for screw max. 6 mm Finger guards from p. 247 Inlet rings from p. 253 Air filter P. 254 Connection diagrams P. 259 149 Representatives Accessories AC centrifugal fans Wire end splices 2016-01 – – – – – Max. 410 m /h DC centrifugal fans and blowers 3 Ø 140 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C *1G 140 M1G 055-BD A 24 16-28 400 1750 54 2.50 63 0 -25...+60 p. 259 / G) *1G 140 M1G 055-BD A 48 36-57 410 1750 54 1.30 63 0 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – Housing: Die-cast aluminum Impeller: Hot-dip galvanized sheet steel Rotor: Painted black Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 22 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 1850 65 64 — A 2’ 2020 61 61 50 A 3’ 2200 57 59 54 A 4’ 2550 43 60 40 A 1 1750 54 63 — A 2 1900 50 59 51 A 3 2030 45 58 54 A 4 2310 32 58 40 A 5 1500 34 60 — A 6 1580 29 56 50 A 7 1670 25 54 53 A 8 1880 19 53 41 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 150 n rpm-1 Information DC centrifugal fans DC axial fans See connection diagram p. 259 Axial I EN 60950-1 A (48 VDC) CCC kg Centrifugal blowers with flange kg R1G 140-AV17 -02 1.0 G1G 140-AV17 -02 2.3 R1G 140-AV21 -02 1.0 G1G 140-AV21 -02 2.3 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal blowers Technical features: Cable exit: Protection class: Conformity with standard(s): Approvals: Weight centrifugal fans – – – – – AC centrifugal fans AC axial fans Clearance for screw max. 6 mm Inlet rings from p. 253 Air filter P. 254 Connection diagrams P. 259 151 Representatives Finger guards from p. 247 2016-01 Accessories Wire end splices Max. 470 m /h DC centrifugal fans and blowers 3 Ø 146 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C *1G 146 M1G 074-BF A 24 16-28 470 2200 100 5.00 68 0 -25...+60 p. 259 / G) *1G 146 M1G 074-BF A 48 36-57 465 2150 100 2.60 67 0 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – Housing: Die-cast aluminum Impeller: Hot-dip galvanized sheet steel Rotor: Painted black Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 42 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 2400 140 70 — A 2’ 2650 130 67 45 A 3’ 3000 110 66 49 A 4’ 3300 100 67 45 A 1 2200 100 68 — A 2 2445 90 65 46 A 3 2750 84 64 49 A 4 3025 77 65 45 A 5 1890 68 63 — A 6 2075 57 60 46 A 7 2250 48 61 49 A 8 2335 41 61 45 A 9 1520 37 59 — A 10 1670 32 55 46 A 11 1815 27 55 49 A 12 1920 23 55 45 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 152 n rpm-1 Information DC centrifugal fans DC axial fans See connection diagram p. 259 Axial I EN 60950-1 UL, CSA, CCC (only centrifugal blowers) kg Centrifugal blowers with flange kg R1G 146-AA07 -52 1.4 G1G 146-BA07 -52 2.8 R1G 146-AA11 -52 1.4 G1G 146-BA11 -52 2.8 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal blowers Technical features: Cable exit: Protection class: Conformity with standard(s): Approvals: Weight centrifugal fans – – – – – AC centrifugal fans AC axial fans Clearance for screw max. 6 mm Inlet rings from p. 253 Air filter P. 254 Connection diagrams P. 259 153 Representatives Finger guards from p. 247 2016-01 Accessories Wire end splices Max. 505 m /h DC centrifugal fans and blowers 3 Ø 160 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C *1G 160 M1G 074-BF A 24 16-28 505 1750 105 5.80 67 0 -25...+60 p. 259 / G) *1G 160 M1G 074-BF A 48 36-57 505 1750 105 2.90 67 0 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – Housing: Die-cast aluminum Impeller: Hot-dip galvanized sheet steel Rotor: Painted black Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 42 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 1890 134 68 — A 2’ 2200 118 67 52 A 3’ 2500 110 67 57 A 4’ 2900 102 69 52 A 1 1750 105 67 — A 2 2030 95 66 52 A 3 2270 90 65 57 A 4 2550 81 67 44 A 5 1580 72 62 — A 6 1810 66 62 52 A 7 2000 58 62 57 A 8 2200 48 63 54 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 154 n rpm-1 Information DC centrifugal fans DC axial fans See connection diagram p. 259 Axial I EN 60950-1 UL, CSA kg Centrifugal blowers with flange kg R1G 160-AH29 -52 1.4 G1G 160-BH29 -52 2.8 R1G 160-AH39 -52 1.4 G1G 160-BH39 -52 2.8 ACmaxx / EC fans Centrifugal fans DC fans - specials Weight centrifugal blowers Technical features: Cable exit: Protection class: Conformity with standard(s): Approvals: Weight centrifugal fans – – – – – AC centrifugal fans AC axial fans Clearance for screw max. 6 mm Inlet rings from p. 253 Air filter P. 254 Connection diagrams P. 259 155 Representatives Finger guards from p. 247 2016-01 Accessories Wire end splices Max. 700 m /h DC centrifugal blowers 3 Ø 133 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C D1G 133 M1G 074-BF A 24 16-28 700 1780 105 5.60 62 50 -25...+60 p. 259 / G) D1G 133 M1G 074-BF A 48 36-57 700 1780 105 2.80 62 50 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – – Housing: Galvanized sheet steel Impeller: Galvanized sheet steel Rotor: Painted black Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 42 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Design: SAL motor mounted with vibration damping on both sides Bearings: Maintenance-free ball bearings Subject to change n rpm-1 Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 LpA dB(A) htL % A 1’ — — — — A 2’ 2050 121 63 49 A 3’ 2490 106 62 41 A 4’ 2820 100 62 37 A 1 1780 105 62 — A 2 1900 97 61 49 A 3 2310 86 59 41 A 4 2630 80 60 37 1500 73 A 5 1720 67 59 — A 6 2020 58 57 49 A 7 49 41 A 2230 56 8 56 37 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 156 Ped W Information DC axial fans See connection diagram p. 259 Variable I EN 60950-1 UL, CSA; A (48 VDC) also CCC DC centrifugal fans Technical features: Cable exit: Protection class: Conformity with standard(s): Approvals: kg D1G 133-AB29 -52 3.3 D1G 133-AB39 -52 3.3 AC centrifugal fans AC axial fans ACmaxx / EC fans Centrifugal blowers without flange DC fans - specials Weight centrifugal blowers Finger guards from p. 246 Connection diagrams P. 259 157 2016-01 Accessories Wire end splices Representatives – – – – – Max. 1020 m /h DC centrifugal blowers 3 Ø 133 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C D1G 133 M1G 074-BF A 24 16-28 1020 1580 118 6.00 64 0 -25...+60 p. 259 / G) D1G 133 M1G 074-BF A 48 36-57 1020 1580 118 3.00 64 0 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – – Housing: Galvanized sheet steel Impeller: Galvanized sheet steel Rotor: Painted black Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 42 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Design: SAL motor mounted with vibration damping on both sides Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 1700 145 65 — A 2’ 1930 133 62 38 A 3’ 2290 122 59 41 A 4’ 2700 99 61 32 A 1 1580 118 64 — A 2 1790 107 61 38 A 3 2100 95 57 41 A 4 2410 73 58 32 A 5 1400 78 60 — A 6 1580 70 56 38 A 7 1760 56 53 41 A 8 2000 44 53 32 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 158 n rpm-1 Information kg D1G 133-DC13 -52 3.4 D1G 133-DC17 -52 3.4 DC centrifugal fans Finger guards from p. 246 Connection diagrams P. 259 159 2016-01 Wire end splices Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / EC fans Centrifugal blowers without flange DC fans - specials Weight centrifugal blowers – – – – See connection diagram p. 259 Interference emission acc. to EN 55022, class B Immunity to interference acc. to EN 61000-6-2 Cable exit: Variable Protection class: I Conformity with standard(s): EN 60950-1 Approvals: UL, CSA DC axial fans – Technical features: – EMC (24 VDC): Max. 1000 m /h DC centrifugal blowers 3 Ø 146 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C D1G 146 M1G 074-CF A 24 16-28 1000 1350 105 5.10 61 0 -25...+60 p. 259 / G) D1G 146 M1G 074-CF A 48 36-57 1000 1350 105 2.60 61 0 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – – Housing: Galvanized sheet steel Impeller: Galvanized sheet steel Rotor: Painted black Direction of rotation: Clockwise, looking towards rotor Degree of protection: IP 42 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Design: SAL motor mounted with vibration damping on both sides Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 1460 129 63 — A 2’ 1680 119 60 53 A 3’ 1890 111 58 61 A 4’ 2240 95 59 55 A 1 1350 105 61 — A 2 1570 95 58 53 A 3 1750 88 56 61 A 4 2010 70 57 55 A 5 1210 70 56 — A 6 1360 60 54 53 A 7 1460 53 52 61 A 8 1670 42 51 55 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 160 n rpm-1 Information kg D1G 146-AA19 -52 3.5 D1G 146-AA33 -52 3.5 DC centrifugal fans AC centrifugal fans AC axial fans ACmaxx / EC fans Centrifugal blowers without flange DC fans - specials Weight centrifugal blowers Finger guards from p. 246 Connection diagrams P. 259 161 2016-01 Accessories Wire end splices Representatives – – – – See connection diagram p. 259 Interference emission acc. to EN 55022, class B Immunity to interference acc. to EN 61000-6-2 Cable exit: Variable Protection class: I Conformity with standard(s): EN 60950-1 Approvals: UL, CSA DC axial fans – Technical features: – EMC (24 VDC): Max. 980 m /h DC centrifugal blowers 3 Ø 160 mm – Material: Power consumption Input current Sound pressure level Min. back-pressure Admissible amb. temp. Motor VDC m3/h rpm-1 W A dB(A) Pa °C D1G 160 M1G 074-CF A 24 16-28 980 1250 112 5.60 60 0 -25...+60 p. 259 / G) D1G 160 M1G 074-CF A 48 36-57 980 1250 112 2.90 60 0 -25...+60 p. 259 / G) Technical features and connection diagram Nominal speed Type Nominal voltage range Nominal data Nominal voltage VDC Curve Air flow – – – – – – – – Housing: Galvanized sheet steel Impeller: Galvanized sheet steel Rotor: Painted black Direction of rotation: Counterclockwise, looking towards rotor Degree of protection: IP 42 Insulation class: "B" Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Design: SAL motor mounted with vibration damping on both sides Bearings: Maintenance-free ball bearings Subject to change Curves: UN = nominal voltage (24 V /48 V) UR = overvoltage (28 V / 57 V) 2016-01 Ped W LpA dB(A) htL % A 1’ 1330 142 63 — A 2’ 1520 128 61 64 A 3’ 1790 115 59 66 A 4’ 2090 105 60 60 A 1 1250 112 60 — A 2 1420 102 59 64 A 3 1660 92 58 66 A 4 1900 80 58 60 A 5 1100 75 58 — A 6 1250 69 56 64 A 7 1420 58 54 66 A 8 1580 47 53 60 Air performance measured according to: ISO 5801, Installation category A, with ebm-papst scroll housing without contact protection. Suction-side noise levels: LWA according to ISO 13347, LpA measured at 1 m distance from fan axis. The values given are applicable only under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation! For detailed information see http://www.ebmpapst.com/general conditions 162 n rpm-1 Information DC axial fans See connection diagram p. 259 Variable I EN 60950-1 UL, CSA DC centrifugal fans Technical features: Cable exit: Protection class: Conformity with standard(s): Approvals: kg D1G 160-DA19 -52 3.6 D1G 160-DA33 -52 3.6 AC axial fans ACmaxx / EC fans Centrifugal blowers without flange DC fans - specials Weight centrifugal blowers Finger guards from p. 246 Connection diagrams P. 259 163 2016-01 Accessories AC centrifugal fans Wire end splices Representatives – – – – – 2016-01 164