GENERAL C8106

Description:
A.
Tinned Copper conductor, FEP Insulation, conductors cabled, overall foil shied and FEP Jacketed Plenum Cable.
Construction:
1.0
Primaries:
1.1
1.2
1.3
1.4
2.0
Conductor:
AWG
Stranding
Nom. Dia
Insulation:
Material
Nom. thickness
Nom. OD
No. of conductors
Color code
18 AWG
19/30 Tinned Copper;
.048"
FEP
.007”
.062"
3
Black, White, Red
3.0
Overall Cabling:
3.1
Separator:
3.2
Shield:
3.3
Drain Wire:
Jacket
Material:
3 conductors cabled
Polyester tape
Aluminum/Polyester Tape; 100% coverage; (Aluminum Side out)
20 AWG Stranded Tinned Copper
FEP
Nom. wall:
.014”
Color:
Red
4.0
Overall Diameter of Cable Nom.
.178”
5.0
Marking:
Characteristics:
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
Conductor DC Resistance @20C Max. (Ohm):
Capacitance between conductors Nom. (pF/ft):
Capacitance Cond. To other Cond.& Shield Nom. (pF/ft):
Shield Resistance Nom.(Ohms/1000’):
Operating Voltage Nom.:
Continuous Operating Temp:
Min. Bend Radius (inches):
Max. Pulling Tension Lbs:
C.
Approvals:
UL –CMP ; C(UL) CMP
R
E
V
DATE
B.
Surface Print:
GENERAL CABLE (F) C8106 3C 18 AWG SHIELDED CMP (UL) C(UL) ---- ROHS
AAAAA*
* Indicates Shop Order number
5.5
50
95
7.5
300 V
200C
1.6
70
CHANGE DETAIL
General Cable
20 Forge Park, Franklin, Ma 02038
Phone: 508-541-7100 Fax: 508-541-8122
Title:
C8106
Description:
3C 18 AWG Shielded Plenum Cable
Created By:
A 06/29/09
Initial Release -VM
Final Approval:
VM 6/29/09
PAGE 1 of 1
General Cable reserves the right to modify this information without prior notification and does not make a warranty or representation of any kind, whether implied or expressed with respect to the information contained
herein. General Cable assumes no risks, and will not be liable for direct or indirect, special; incidental or consequential damages, any defect or personal injury resulting from the use of this document.