Agilent U1250 Series Handheld Digital Multimeters Data Sheet Test more – more safely The Agilent U1250 Series handheld digital multimeters (DMMs) exceed your expectations by delivering powerful features and performance that meet your toughest requirements and applications. The series’ latest multimeters, the U1251B, U1252B and U1253B come in vivid orange cases, offering capabilities and functions equivalent to the U1250A Series. Key features Superior contrast from organic LED (OLED) display1 50,000-count dual display Up to 0.025% basic DCV accuracy True-RMS AC and AC+DC2 measurements K-type and J-type2 temperature measurements Manual and automated (interval) data logging; internally to DMM and externally to PC CAT III 1000 V and CAT IV 600 V Do more with just one instrument The basic model, U1251A/U1251B, expands your capabilities beyond typical DMM measurements to include data logging. The U1252A/U1252B starts with the same foundation, and then adds a 20MHz frequency counter and programmable square-wave generator — so you’d be able to perform more tests conveniently with one tool. What’s more: both models come bundled with a complete set of accessories to equip you right from the start at no extra cost. Offering the same functionality as the U1252A/U1252B, the U1253A/U1253B is the world’s first OLED handheld DMM. You won’t have to squint to be sure you’re reading it right: On the go or on the bench, you’ll get crystal-clear viewing indoors, even in dark, off-angle situations. safety protection Built-in 20-MHz frequency counter2 Built-in programmable square-wave generator2 [1] U1253A/U1253B model [2] U1252A/U1252B/U1253A/U1253B models Figure 1: Automate recording of measurements with bundled GUI data-logging software. Find problems quickly Troubleshooting can be tricky, especially when you’re dealing with elusive problems. With the U1250 Series’data logging capability, you can ensure that every reading gets recorded manually or at intervals you specify. Better yet: you can have virtually unlimited data logging saves when you connect any of the U1250 Series DMM to a PC with the optional IR-to-USB cable. In addition, the U1250 Series lets you achieve greater confidence in your measurements with accurate true-RMS AC measurements, low DCV error rate of up to 0.025% and high-resolution display of 50,000 counts. Uncompromising ruggedness and safety The U1250 Series DMMs are housed in robust overmold enclosures, rated at CAT III 1000 V and CAT IV 600 V and operate over a wide temperature range of –20 °C to +55 °C. Each DMM also include a 30 kA high energy fuse to further protect you against violent fuse failures during high-current measurements. Built tough and certified to stringent industrial standards, the U1250 DMM is what you need to face the demands of everyday tasks. Take a closer look OLED display with approximately 160° viewing angle, and high contrast ratio of 2000:1 for crystal-clear viewing 1 50,000 count dual display with trueRMS reading capability 20 MHz frequency counter 2 SHIFT key and one-stop function keys for easy access Data logging to internal or external memory Broad range of measurement functions, including temperature and capacitance Programmable square-wave generator for stimulation of digital circuits 2 CAT III 1000 V and CAT IV 600 V overvoltage protection for assurance of your safety while you go about your tasks Built-in battery charging for optimum capacity Figure 2: U1253B front view [1] U1253A/U1253B only [2] U1252A/U1252B/U1253A/U1253B only 2 DC SPECIFICATIONS FUNCTION VOLTAGE (1) RANGE RESOLUTION 50.000 mV 0.001 mV - 500.00 mV 0.01 mV - 1000.0 mV 0.1 mV - 5.0000 V 0.0001 V - 50.000 V 0.001 V - 500.00 V 0.01 V - 1000.0 V 0.1 V - 500.00 W[3] 0.01 W 1.04 mA U1251A/U1251B U1252A/52B/53A/53B 0.05 + 50[2] 0.05 + 50[2] 0.025 + 5 0.03 + 5 0.03 + 5 0.08 +10 0.05 + 10 0.08 + 5 0.05 + 5 0.15 +5 416 µA 0.001 kW 41.2 µA 500.00 kW 0.01 kW 4.12 µA 5.0000 MW 0.0001 MW 375 nA 0.2 + 5 50.000 kW 50.000 MW 0.001 MW 187 nA 1 + 10 1+5 500.00 MW[4] 0.01 MW 187 nA N/A 3+10 < 200 MW / 8+10 > 200 MW 1 + 20 1 + 10 0.1 + 5[6] 0.05 + 5[6] 0.2 + 5[6] 0.15 + 5[6] [4] CURRENT ACCURACY ± (% of reading + No. of Least Significant Digit) 0.0001 kW 5.0000 kW [3] RESISTANCE(8) TEST CURRENT/ BURDEN VOLTAGE 500.00 nS[5] 0.01 nS 187 nA 500.00 µA 0.01 µA 0.06 V (100 W) 5000.0 µA 0.1 µA 0.6 V (100 W) 50.000 mA 0.001 mA 0.09 V (1 W) 440.00 mA 0.01 mA 0.9 V (1 W) 5.0000 A 0.0001 A 0.2 V (0.01 W) 0.001 A 0.4 V (0.01 W) 0.1 mV 1.04 mA 10.000 A [7] DIODE TEST(8) - 0.3 + 10 0.3 + 10 0.3 + 5 0.05 + 5 [1] [2] [3] [4] [5] [6] Input impedance: Refer to Table A on page 8. The accuracy could be 0.05% + 10 for U1251A and 0.05% + 5 for U1252A/3A. Always use the NULL function to zero out the thermal effect before measuring the signal. The accuracy of 500 W and 5 kW is specified after NULL function, which is used to subtract the test lead resistance and the thermal effect. For the range of 50 MW and 500 MW, the R.H. is specified for <60%. The accuracy is specified for <50 nS and after NULL function with open test lead. Always use the NULL function to zero out thermal effect with open test lead before measuring the signal. If the NULL function is not used, an additional 20 counts needs to be added to the DC current accuracy. Thermal effect could occur due to the following: • Wrong operation to measure the high voltage of 50 V ~ 1000 V for resistance, diode, and mV measurements. • After battery-charging has completed. • After measuring a current greater than 440 mA, it is suggested that the meter be left to cool down for twice the measuring time used. [7] Current can be measured up to 10 A continuously. An additional 0.5% needs to be added to the specified accuracy if the signal measured is in the range of 10 A~20 A for 30 seconds maximum. After measuring a current of > 10 A, leave the meter to cool down for twice the measuring time used before application of low current measurement. [8] Maximum open voltage: <+ 4.2V. U1251A/U1251B AC SPECIFICATIONS ACCURACY ± (% of reading + No. of Least Significant Digit) FUNCTION RANGE RESOLUTION FREQUENCY 30 Hz ~ 45 Hz TRUE RMS AC VOLTAGE[1] [2] 50.000 mV 0.001 mV 500.00 mV 0.01 mV 1000.0 mV 0.1 mV 5.0000 V 0.0001 V 50.000 V 0.001 V 500.00 V 0.01 V 1000.0 V 0.1 V 45 Hz ~ 1 kHz 0.6+40 1.0+60 0.6+25 1 kHz ~ 10 kHz 10 kHz ~ 30 kHz 1.0+40 1.6+60 1.0+25 1.6+40 1.6+40[3] 0.6+40 3 1.0+40 N/A ACCURACY ± (% of reading + No. of Least Significant Digit) FUNCTION RANGE RESOLUTION FREQUENCY 30 Hz ~ 45 Hz 500.00 µA [4] AC CURRENT[2] 0.01 µA 5000.0 µA 0.1 µA 50.000 mA 0.001 mA 440.00 mA 0.01 mA 5.0000 A 0.0001 A 10.000 A[5] 0.001 A 45 Hz ~ 2 kHz 2 kHz ~ 20 kHz 1.5+50 3.0+80 1.5+40 3.0+60 0.8+20 3+60, <3 A/5 kHz 2.0+40[6] U1252A/U1252B/U1253A/U1253B AC SPECIFICATIONS ACCURACY ± (% of reading + No. of Least Significant Digit) FUNCTION RANGE RESOLUTION FREQUENCY 20 Hz ~ 45 Hz TRUE RMS AC VOLTAGE[1] [8] 50.000 mV 0.001 mV 500.00 mV 0.01 mV 1000.0 mV 0.1 mV 5.0000 V 0.0001 V 50.000 V 0.001 V 500.00 V 0.01 V 1000.0 V 0.1 V RANGE RESOLUTION 45 Hz ~ 1 kHz 1 kHz ~ 10 kHz 0.4+40 0.7+40 10 kHz ~ 20 kHz 0.75+40 0.4+25 1.5+60 0.4+25 20 kHz~100 kHz[5] 3.5+120 0.6+25 1.5+40 0.4+25 0.4+40 3.5+120[3] 0.4+40 1.5+40 N/A [3] ACCURACY ± (% of reading + No. of Least Significant Digit) FUNCTION FREQUENCY 20 Hz ~ 45 Hz 500.00 µA 0.01 µA 5000.0 µA 0.1 µA 50.000 mA 0.001 mA 440.00 mA 0.01 mA 5.0000 A 0.0001 A 10.000 A[5] 0.001 A [4] AC CURRENT[8] 45 Hz ~ 1 kHz 1 kHz ~ 20 kHz 0.75+20 1.0+20 0.7+20 5.0+80 1.5+20 3+60, <3 A/5 kHz 1.5+20[6] 20 kHz~100 kHz[7] N/A [1] Input impedance: Refer to Table A on page 8. [2] AC mV/V and AC µA/mA/A specifications are true RMS AC coupled, valid from 5% to 100% of range. The crest factor may be up to 3 at full scale, up to 5 at halfscale, except for 1000 mV and 1000 V ranges, where the crest factor is 1.5 at full scale and 3 at half scale. [3] The input signal is lower than 20,000,000 V-Hz (the product of voltage and frequency). [4] Input current >35 µArms. [5] Current can be measured from 2.5 A up to 10 A continuously. An additional 0.5% needs to be added to the specified accuracy if the signal measured is in the range of 10 A ~ 20 A for 30 seconds maximum. After measuring a current of >10 A, leave the meter to cool down for twice the measuring time used before application of low current measurement. [6] Input current < 3 Arms. [7] The additional error to be added as frequency >20 kHz and signal input <10% of range: 3 counts of LSD per kHz. [8] Crest factor ≤ 3.0 at full scale, 5.0 at half scale except the 1000 mV and 1000 V ranges where it is 1.5 at full scale, 3.0 at half scale. For non-sinusoidal waveform, add 0.1% of reading ± 0.3% of range. 4 U1252A/U1252B/U1253A/U1253B AC+DC SPECIFICATIONS ACCURACY ± (% of reading + No. of Least Significant Digit) FUNCTION TRUE RMS AC VOLTAGE[1] [2] RANGE RESOLUTION 50.000 mV 0.001 mV 500.00 mV 0.01 mV 1000.0 mV 0.1 mV 5.0000 V 0.0001 V 50.000 V 0.001 V 500.00 V 0.01 V 1000.00 V 0.1 V FREQUENCY 30 Hz ~ 45 Hz 45 Hz ~ 1 kHz 1 kHz ~ 10 kHz 10 kHz ~ 20 kHz 20 kHz~100 kHz[3] 1.5+80 0.4+60 0.7+60 0.8+60 3.5+220 0.4+30 0.8+45 0.4+30 1.5+65 0.4+30 0.4+45 3.5+125 0.6+30 0.4+45 1.5+45 3.5+125[4] 1.5+45 N/A [4] ACCURACY ± (% of reading + No. of Least Significant Digit) FUNCTION AC CURRENT RANGE RESOLUTION 500.00 µA[5] 0.01 µA 5000.0 µA 0.1 µA 50.000 mA 0.001 mA 440.00 mA 0.01 mA 5.0000 A 0.0001 A FREQUENCY 30 Hz ~ 45 Hz 45 Hz ~ 1 kHz 1 kHz ~ 20 kHz 1.1+25 0.8+25 0.8+25 1.2+25 0.9+25 0.9+25 0.9+30 3.3+70, <3 A/5 kHz 1.8+30[7] 0.001 A 10.000 A [6] 0.9+25 U1251A/U1251B/U1252A/U1252B TEMPERATURE SPECIFICATIONS THERMOCOUPLE TYPE RANGE RESOLUTION ACCURACY ºC ºF ºC ºF K –200 ~ 1372 ºC –328 ~ 2502 ºF 0.1 ºC/0.1 ºF 0.3% + 3 ºC 0.3% + 6 ºF J –210 ~ 1200 ºC –346 ~ 2192 ºF 0.1 ºC/0.1 ºF 0.3% + 3 ºC 0.3% + 6 ºF (for U1252A) U1253A/U1253B TEMPERATURE SPECIFICATIONS THERMOCOUPLE TYPE K J RANGE RESOLUTION ºC ºF –200 ~ –40 °C –104 ~ –40 °F ACCURACY ºC ºF 0.1 ºC/0.1 ºF 1% + 3 °C 1% + 5.4 °F –40 ~1372 °C –40 ~ 2502 °F 0.1 °C /0.1 °F 1% + 1 °C 1% + 1.8 °F –210 ~ –40 °C –346 ~ –40 °F 0.1 °C /0.1 °F 1% + 3 °C 1% + 5.4 °F –40 ~ 1200 °C –40 ~ 2192 °F 0.1 °C /0.1 °F 1% + 1 °C 1% + 1.8 °F CAPACITANCE SPECIFICATIONS RANGE RESOLUTION ACCURACY 10.000 nF 0.001 nF 1% + 8 100.00 nF 0.01 nF 1000.0 nF 0.1 nF 10.000 µF 0.001 µF 100.00 µF 0.01 µF 1000.0 µF 0.1 µF 10.000 mF 0.001 mF 100.00 mF 0.01 mF MEASURING RATE AT FULL SCALE MAX. DISPLAY 4 times/sec. 1% + 5 11000 counts 1 time/sec. 0.1 times/sec. 3% + 10 5 0.01 times/sec FREQUENCY SPECIFICATIONS[4] RANGE 99.999 Hz 999.99 Hz RESOLUTION ACCURACY U1251A/2A U1253A 0.02%+3[8] 0.02%+3[8] 0.02%+3, <600 kHz 0.02%+3, <600 kHz 0.001 Hz MIN. INPUT FREQUENCY 0.01 Hz 9.9999 kHz 0.0001 kHz 99.999 kHz 0.001 kHz 999.99 kHz 0.01 kHz 1 Hz [1] Input impedance: Refer to Table A on page 8. [2] Crest factor ≤ 3.0 at full scale, 5.0 at half scale except the 1000 mV and 1000 V ranges where it is 1.5 at full scale, 3.0 at half scale. For non-sinusoidal waveform, add 0.1% of reading ± 0.3% of range. [3] The additional error to be added as frequency >20 kHz and signal input <10% of range: 3 counts of LSD per kHz. [4] The input signal is lower than 20,000,000 V-Hz (the product of voltage and frequency). [5] Input current >35 µArms. [6] Current can be measured from 2.5 A up to 10 A continuously. An additional 0.5% needs to be added to the specified accuracy if the signal measured is in the range of 10 A ~ 20 A for 30 seconds maximum. After measuring a current of >10 A, leave the meter to cool down for twice the measuring time used before application of low current measurement. [7] Input current < 3 Arms. [8] For non-square wave signals, add 5 counts. U1251A/U1251B FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT FREQUENCY SENSITIVITY AND TRIGGER LEVEL INPUT RANGE MINIMUM SENSITIVITY (R.M.S. Sine Wave) TRIGGER LEVEL FOR DC COUPLING (Maximum input for specified accuracy = 10 x Range or 1000 V) 20 Hz - 100 kHz >100 kHz ~ 200 kHz < 100 kHz >100 kHz ~ 200 kHz 50.000 mV 10 mV 15 mV 10 mV 15 mV 500.00 mV 25 mV 35 mV 60 mV 70 mV 1000.0 mV 40 mV 50 mV 100 mV 150 mV 5.0000 V 0.25 V 0.5 V 0.5 V / 1.25 V (< 100 Hz) 0.6 V 50.000 V 2.5 V 5V 5V 6V 500.00 V 25 V N/A 50 V N/A 1000.0 V 50 V N/A 300 V N/A U1252A/U1252B/U1253A/U1253B FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT FREQUENCY SENSITIVITY AND TRIGGER LEVEL INPUT RANGE MINIMUM SENSITIVITY (R.M.S. Sine Wave) TRIGGER LEVEL FOR DC COUPLING (Maximum input for specified accuracy = 10 x Range or 1000 V) 20 Hz ~ 200 kHz >200 kHz ~ 500 kHz < 100 kHz >100 kHz ~ 500 kHz 50.000 mV 10 mV 25 mV 10 mV 25 mV 500.00 mV 70 mV 150 mV 70 mV 150 mV 1000.0 mV 120 mV 300 mV 120 mV 300 mV 5.0000 V 0.3 V 1.2 V 0.6 V 1.5 V 50.000 V 3V 5V 6V 15 V 500.00 V 30 V < 100 kHz N/A 60 V N/A 1000.0 V 50 V < 100 kHz N/A 120 V N/A 6 FREQUENCY SENSITIVITY DURING CURRENT MEASUREMENT INPUT RANGE MINIMUM SENSITIVITY (R.M.S. Sine Wave) 20 Hz ~ 20 kHz 500.00 µA 100 µA 5000.0 µA 250 µA 50.000 mA 10 mA 440.00 mA 25 mA 5.0000 A 1A 10.000 A 2.5 A SIGNAL WIDTH ACCURACY FOR DC mV/VOLTAGE/CURRENT PEAK HOLD Single event > 1 ms 2% + 400 for all ranges Repetitive > 250 µs 2% + 1000 for all ranges DUTY CYCLE AND PULSE WIDTH [1] FUNCTION MODE RANGE ACCURACY AT FULL SCALE DUTY CYCLE DC Coupling 0.01% ~ 99.99% 0.3% per kHz + 0.3% PULSE WIDTH 500 ms 0.01 ms 0.2% + 3 2000 ms 0.1 ms 0.2% + 3 [1] The positive or negative pulse width must be greater than 10 µs, and the duty cycle range should be considered. The pulse width range is determined by the frequency of the signal. U1252A/U1252B/U1253A/U1253B FREQUENCY COUNTER SPECIFICATIONS DIVISION RANGE RESOLUTION ACCURACY ± (% of reading + No. of Least Significant Digit) U1252A 1 (secondary display “-1-“) 100 (secondary display “-100-“) 99.999 Hz 0.001 Hz 999.99 Hz 0.01 Hz 9.9999 kHz 0.0001 kHz 99.999 kHz 0.001 kHz 999.99 kHz 0.01 kHz 9.9999 MHz 0.0001 MHz 9.9999 MHz 0.0001 MHz 99.999 MHz 0.001 MHz SENSITIVITY MIN. INPUT FREQUENCY U1253A 0.02% + 3 [1] MAXIMUM MEASUREMENT LEVEL 0.02% + 3[1] 100 mV R.M.S. 0.002% + 5, <985 kHz < 30 Vpp 200 mV R.M.S. 0.002% + 5, < 1 MHz 0.002% + 5, < 20 MHz 0.5 Hz 0.002% + 5, < 985 kHz 0.002% + 5, < 20 MHz 400 mV R.M.S. 600 mV R.M.S. 1 MHz U1252A/U1252B/U1253A/U1253B SQUARE WAVE OUTPUT OUTPUT[2] FREQUENCY DUTY CYCLE[3] PULSE WIDTH[4] AMPLITUDE RANGE RESOLUTION ACCURACY 0.5, 1, 2, 5, 6[6], 10, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 150, 200, 240, 300, 400, 480, 600, 800, 1200, 1600, 2400, 48000 Hz 0.01 Hz 0.005% + 2 0.39% ~ 99.60% 0.390625% 0.4% of full scale[4] 1/Frequency Range/256 0.2 ms + Range/256 Fixed 0 ~ +2.8 V 0.1 V 0.2 V 7 MEASURING RATE MANUAL AND INTERVAL DATA LOGGING FUNCTION TIMES/SECOND ACV 7 ACV + dB 7 DCV 7 AC + DC V 2 W /nS 14 Diode 14 Capacitance 4 (< 100 µF) DCI 7 ACI 7 AC + DC I 2 Temperature 6 Frequency 1 (>10 Hz) Duty cycle/Pulse width 0.5 (>10 Hz) LOGGING TYPE MAXIMUM DATA POINTS[5] U1251A U1252A U1253A MANUAL 100 100 100 INTERVAL 200 200 1000 DECIBEL (dB) CALCULATION dB BASE REFERENCE DEFAULT REFERENCE 1 mW (dBm) 1-9999 W 50 W 1 V (dBV) 1V 1V [1] All frequency counters are susceptible to errors. Shielding inputs from external noise pickup is critical to minimize measurement errors. For non-square wave signals, add 5 counts. [2] Output impedance: 3.5 kW maximum. [3] The positive or negative pulse width must be greater than 50 µs for adjustment of the duty cycle or pulse width under different frequencies. Otherwise, the accuracy and range will be different from the specifications defined. [4] For signal frequencies greater than 1 kHz, an addition of 0.1% per kHz is added to the accuracy. [5] For data logging to PC, maximum number of data points is dependent on available hard disk space. [6] For the U1253A/U1253B model. INPUT IMPEDANCE Table A FUNCTION DC Voltage [1] AC Voltage[2] AC + DC Voltage[2] RANGE INPUT IMPEDANCE 50.000 mV 10.00 MW 500.00 mV 10.00 MW 1000.0 mV 10.00 MW 5.0000 V 11.10 MW 50.000 V 10.10 MW 500.00 V 10.01 MW 1000.0 V 10.001 MW 50.000 mV 10.00 MW 500.00 mV 10.00 MW 1000.0 mV 10.00 MW 5.0000 V 10.00 MW 50.000 V 10.00 MW 500.00 V 10.00 MW 1000.0 V 10.00 MW 50.000 mV 10.00 MW 500.00 mV 10.00 MW 1000.0 mV 10.00 MW 5.0000 V 11.10 MW || 10 MW 50.000 V 10.10 MW || 10 MW 500.00 V 10.01 MW || 10 MW 1000.0 V 10.001 MW || 10 MW [1] For 5 V to 1000 V range, the specified input impedance in parallel with 10 MW at dual display. [2] The specified input impedance (nominal) in parallel with <100 pF. 8 GENERAL SPECIFICATIONS DISPLAY Both primary and secondary displays are 5-digit on the LCD display. Both the primary and secondary displays offer a maximum resolution of 50,000 counts. Automatic polarity indication. POWER CONSUMPTION 105 mVA / 420 mVA (with backlight) maximum (U1251A/U1251B) 165 mVA / 480 mVA (with backlight) maximum (U1252A/U1252B) 420 mVA maximum (U1253A/U1253B) BATTERY TYPE 9 V Alkaline battery (ANSI/NEDA 1604A or IEC 6LR61) 9 V Carbon-zinc battery (ANSI/NEDA 1604D or IEC6F22) 7.2 V or 8.4 V Ni-MH Rechargeable battery BATTERY LIFE U1251A/U1251B: 72 hours typical U1252A/U1252B: 36 hours typical U1253A/U1253B: 8 hours typical OPERATING ENVIRONMENT • Full accuracy at –20 oC to 55 oC ; and to 80% RH for temperatures up to 35 °C, decreasing linearly to 50% RH at 55 °C • 0 to 2000 m altitude per IEC 61010-1 2nd Edition CAT III, 1000 V / CAT IV, 600 V STORAGE COMPLIANCE –40 oC to 70 oC with battery removed SAFETY COMPLIANCE • IEC 61010-1:2001 / EN610101-1:2001 • Canada: CSA C22.2 No. 61010-1:2004 MEASUREMENT CATEGORY CAT III 1000 V / CAT IV 600 V EMC COMPLIANCE Certified to IEC/EN 61326: 2002, CISPR 11, and equivalents for Group 1, Class A COMMON MODE REJECTION RATIO (CMRR) U1251A/U1251B/U1252A/U1252B: >90 dB at DC, 50/60 Hz ± 0.1% (1 kW unbalanced) U1253A/U1253B: >100 dB at DC, 50/60 Hz ± 0.1% (1 kW unbalanced) NORMAL MODE REJECTION RATIO (NMRR) U1251A/U1251B/U1252A/U1252B: >60 dB at DC, 50/60 Hz ± 0.1% U1253A/U1253B: >90 dB at DC, 50/60 Hz ± 0.1% TEMPERATURE COEFFICIENT 0.15 * (specified accuracy)/oC (from 20 oC to 18 oC or 28 oC to 55 oC) SHOCK and VIBRATION Tested to IEC/EN 60068-2 DIMENSIONS (HxWxD) 203.5 mm x 94.4 mm x 59.0 mm WEIGHT U1251A/U1251B: 504±5 g with battery U1252A/U1252B/U1253A/U1253B: 527±5 g with battery CHARGING TIME (only U1252A/3A) < 220 minutes approx. at the environment of 10 oC to 30 oC WARRANTY 3 years for main unit 3 months for standard accessories unless otherwise specified. 9 ORDERING INFORMATION U1251A U1251B U1252A U1252B U1253A U1253B STANDARD SHIPPED ACCESSORIES DESCRIPTION APPLICABLE MODELS U1251A U1252A U1253A U1251B U1252B U1253B Alligator clips • • • • • • SMT grabbers • • – – – – Fine-tip test probes • • – – – – Test probe leads (4-mm) • • • • • • Test probe leads (19-mm) • • • • • • Mini grabber • • – – – – Alkaline 9 V battery • – – • – – Rechargeable Ni-MH battery with power adapter – • • – • • Soft carrying case • • – – – – Certificate of Calibration • • • • • • Test Report • • • • • • Quick Start Guide • • • • • • U1253A OPTION Option 001 Bundled SMT grabbers, fine-tip test probes and soft carrying case OPTIONAL ACCESSORIES MEASURING ACCESSORIES (NON-TEMPERATURE) U1160A Standard test lead kit Includes two test leads (red and black), alligator clips, fine-tip test probes, SMT grabbers and mini grabber (black). • • • • • Test leads: CAT III 1000 V, 15 A Alligator clips: CAT III 1000 V, 10 A Fine-tip test probes: CAT II 300 V, 3 A SMT grabbers: CAT II 300 V, 3 A Mini grabber: CAT II 300 V, 3 A U1161A Extended test lead kit U1162A Alligator clips Includes two test leads (red and black), two test probes, medium-sized alligator clips and 4-mm banana plugs. • One pair of insulated alligator clips (red and black). Recommended for use with Agilent standard test leads. • Rated CAT III 1000 V, 10 A. • • • • Test leads: CAT III 1000 V, CAT IV 600 V, 15 A Test probes: CAT III 1000 V, 15 A Medium-sized alligator clips: CAT III 600 V, 10 A 4-mm banana plugs: CAT II 600 V, 10 A 10 U1163A SMT grabbers U1164A Fine-tip test probes U1165A Test probe leads • One pair of SMT grabbers (red and black). Recommended for use with Agilent standard test leads. • Rated CAT II 300 V, 3 A. • One pair of fine-tip test probes (red and black). Recommended for use with Agilent standard test leads. • Rated CAT II 300 V, 3 A. • Rated CAT III 1000 V, 15 A MEASURING ACCESSORIES (NON-TEMPERATURE) U1168A Standard test lead kit U1169A Test probe leads U1583B AC current clamp Includes two test leads (red and black), 19-mm and 4-mm test probes, alligator clips, fine-tip test probes, SMT grabbers and mini grabber (black). Includes two test leads (red and black), and a pair each of 19-mm and 4-mm test probes. • Dual range: 40 A and 400 A • Rated CAT III 600 V • BNC-to-banana-plug adapter provided for use with DMMs • Test leads: CAT III 1000 V, CAT IV 600 V, 15 A • Test probes (19-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A • Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A (highly recommended for CAT IV environment) • Alligator clips: CAT III 1000 V, 10 A • Fine-tip test probes: CAT II 300 V, 3 A • SMT grabber: CAT II 300 V, 3 A • Mini grabber: CAT II 300 V, 3 A • Test leads: CAT III 1000 V, CAT IV 600 V, 15 A • Test probes (19-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A • Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A (highly recommended for CAT IV environment) MEASURING ACCESSORIES (TEMPERATURE) U1181A Immersion temperature probe U1182A Industrial surface temperature probe • Type-K T/C for use in oil and other liquids • Measurement range: –50 °C to 700 ºC • Includes adapter U1184A for connection to DMM • Type-K T/C for use on still surfaces • Measurement range: –50 ºC to 400 ºC • Includes adapter U1184A for connection to DMM U1183A Air temperature probe U1184A Temperature probe adapter U1185A J-type thermocouple and adapter • Type-K T/C for use in air and non-caustic gas • Measurement range: –50 ºC to 800 ºC • Includes adapter U1184A for connection to DMM • Mini-connector-to-banana-plug adapter for use with DMM • T/C adapter J/K-type • T/C bead J-type: –20 °C to 200 °C U1180A Thermocouple adapter+lead kit, J and K types Includes thermocouple adapter, thermocouple bead J-type and thermocouple bead K-type. • T/C adapter J/K-type • T/C bead J-type: –20 °C to 200 °C • T/C bead K-type: –20 °C to 200 °C 11 MEASURING ACCESSORIES (TEMPERATURE) U1186A K-type thermocouple and adapter • T/C adapter J/K-type • T/C bead J-type: –20 °C to 200 °C CABLE CARRYING CASE U1173A IR-to-USB cable U1172A Transit case (aluminium-clad) U1174A Soft carrying case • For remote control and data logging to PC • Max. baud rate: 19,200 bits per second The robust casing to transport your DMM and accessories The convenient way to carry your DMM and essential accessories • Aluminum-clad, black panel construction • Dimension: 18” (H) x 13” (W) x 6“ (D) • Weight: 4 kg • Dimension: 9” (H) x 5” (W) x 3” (D) HANGING KIT AC ADAPTOR U1171A Magnetic hanging kit U1170A AC adaptor For fastening of DMM to a steel surface so both hands are free. Includes AC power cord based on country 12 www.agilent.com www.agilent.com/find/handhelddmm Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For information regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Latin America United States (877) 894 4414 305 269 7500 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 Europe & Middle East Austria Belgium Denmark Finland France 43 (0) 1 360 277 1571 32 (0) 2 404 93 40 45 70 13 15 15 358 (0) 10 855 2100 0825 010 700* *0.125 €/minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2009 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2009 Printed in USA, November 25, 2009 5989-5509EN Agilent U1177A IR-to-Bluetooth Adapter Data Sheet Features • Enables Bluetooth® connection to Agilent handheld digital multimeters • Easy to install by attaching to Infrared (IR) port located at the back of Agilent handheld digital multimeters • Compatible with Agilent U1230 series, U1240 series, U1250 series and U1270 series handheld digital multimeters • Operated by two 1.5 V AAA batteries The Bluetooth® word mark and logos are registered trademark owned by Bluetooth SIG, Inc and any use of such marks by Agilent Technologies, Inc. is under license. Other trademark and trade names are those of their respective owners. Agilent U1177A Infrared (IR)-to-Bluetooth® adapter offers wireless remote connectivity solution via Bluetooth® connection simply by attaching the adapter to the IR port of an Agilent handheld digital multimeter. The wireless remote connectivity is set up when an Agilent handheld digital multimeter is connected to U1177A and an Android device (tablet or smart phone) with the installed software. Every U1177A also has a unique Media Access Control (MAC) address. User can quickly and easily scan for the right U1177A using their Android device and pair up with the U1177A. Figure 1. Agilent wireless remote connectivity solution Take a closer look Low battery indication: Red LED flashing Bluetooth® disconnected: Green LED flashing Bluetooth® connected: Green solid LED Bluetooth® power off: LED off ON/OFF/Setup slide switch Figure 2. The U1177A as illustrated 2 Perform data logging with multimeters – wirelessly! Data logging is an important function for industrial users to capture data streams or plotting trending graphs. These data and graphs are used for analysis to identify intermittent behavior or detect drifts. Agilent Mobile Logger is the free Android application software that logs data and provides trending graphs from Agilent handheld digital multimeters. Agilent Mobile Logger offers an array of extended functions such as sending e-mail or Short Message Service (SMS) automatically, and pan and zoom function via the Android device’s touch screen. Alternatively, data logging and monitoring activities can also be performed at the comfort of one’s Personal Computer (PC) via a downloadable Agilent GUI data logger software. Notes: 1. Agilent Mobile Meter and Agilent Mobile Logger can be downloaded from www.agilent.com/ find/hh-Android or from Android Market (https://market.android.com/) 2. Agilent GUI Data Logger Software can be www.agilent.com/find/hh-logger Figure 3. Data logging with Agilent Mobile Logger software. Perform up to three multimeter measurements at the same time with Agilent Mobile Meter Agilent Mobile Meter is a free Android application software that allows an Android device to connect, control and perform up to 3 multimeter measurements. Without the need to be physically present at various points, users can now extend their reach to two or three places. This solution allows you to make measurements from a safe distance, eliminates the need to walk back-and-forth between measure target and control points, and monitors multiple measurements simultaneously. Achieve higher work productivity when you use the U1177A with your Agilent handheld digital multimeters. Figure 4. Up to three multimeters measurements with the Agilent Mobile Meter Figure 5. Make measurements with the Agilent Mobile Meter via an Android smart phone 3 Specifications Product characteristics Description Radio specification • • • • Operating environment Operating temperature from –20 to 55 °C Storage environment Storage temperature from –40 to 70 °C Relative humidity (R.H.) Relative humidity up to 95% at 40 °C (non-condensing) Power consumption Maximum 130 mVA for two 1.5 V AAA batteries Battery life 30 hours typical (based on continuous data transfer) Battery type Alkaline 24 A (ANSI/NEDA) and LR03 (IEC), or Zinc Chloride 24 D (ANSI/NEDA) and R03 (IEC) Dimension (W x H x L) 39.0 × 71.0 × 37.0 mm Weight 60 g with batteries Warranty Three months Bluetooth "Bluetooth" Version 2.1 + EDR compliant, SPP profile, Class 2 device (with 10 metres connection range) Safety Frequency: 2402 MHz ~ 2480 MHz Antenna Power: 1 mW or less Number of Channels: 79 Modulation: GFSK / PSK The U1177A complies with the requirements of the following safety and regulation standards: • FCC Part15C (Certification) (15.209, 15.247) FCC ID: ZKMAGILENT-U1177A • FCC Part15B (DoC) (15.109) • RSS–210 Issue 8:2010 IC: 6310A–U1177A • ICES–003 Issue 4:2004 • EN 300 328 V1.7.1:2008 • EN 301 489–1V1.8.1:2008/–17 V2.11:2009 • EN 55022:2006+A1:2007/EN55024:1998+A1:2001+A2:2003 • EN 50371:2002 • EN 60950–1:2006/A11:2009/A1:2010 • Complies with IDA Standards (DB 102425) • India Equipment Type Approval (ETA) Certificate No: 1424/2011/WRLO • COFETEL Certificate No: RCPAGU111-1066, registered under Agilent Technologies Mexico S de RL de CV "This telecommunication equipment conforms NTC technical requirement" Standard shipped items: • Two 1.5 V AAA batteries • Operating instructions 4 www.agilent.com www.agilent.com/find/U1177A For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based highperformance measurement and automation system. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience. Agilent Advantage Services is committed to your success throughout your equipment’s lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world. www.agilent.com/find/advantageservices www.agilent.com/quality www.agilent.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 (11) 4197 3600 01800 5064 800 (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100 Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 €/minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus Revised: January 6, 2012 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2012 Published in USA, February 2, 2012 5990-9531EN