HY PD5006N

PD5002P(N) thru PD5006P(N)
REVERSE VOLTAGE -200 to 600Volts
GLASS PASSIVATED AUTO RECTIFIERS
FORWARD CURRENT -50 Amperes
PRESS-FIT
FEATURES
Φ.044(11.1)
Φ.042(10.7)
● Low forward volage drop
● High current capability
MECHANICAL
● Case: OFC Heat Sink
● Encap:Epoxy Sealed Rated UL94V-0
.370(9.4)
.360(9.0)
1.181(30.0)
1.063(27.0)
● High surge current capability
● Weight: 7.05gram
.201(5.1)
.193(4.9)
Φ .053(1.35)
Φ.049(1.25)
● High reliability
Φ.417(10.6)
Φ.409(10.4)
Φ.506(12.85)
Φ.500(12.70)
Ring color
P
Black
N
Brown
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25℃ unless otherwise specified.
Single phase,half wave,60HZ,resistive or inductive load .
For capacitive load,deraate current by 20%
SYMBOL
PD5002P(N)
PD5004P(N)
PD5006P(N)
MARKING
5002
5004
5006
Maximum Peak Repetitive Reverse Voltage @Irrm=10uA
VRRM
200
400
600
V
Maximum RMS Voltage
VRMS
140
280
420
V
VB
200
400
600
V
CHARACTERISTICS
Maximum DC Blocking Voltage (TA=25℃)
UNIT
Maximum Average Forward Current IO@TC=150℃
60HZ,resistive or inductive load
I(AV)
50
A
Peak Forward Surage Current 8.3ms single half sine-wave
superimposed on rated load (JEDEC method)
IFSM
600
A
Maximum Inst. Forward Voltage Drop,
IF at 100Amp
VF
1.1
V
Maximum DC Reverse Current (VB)@TJ=25℃
At Rated DC Bolcking Voltage (VB)@TJ=175℃
IR
Operating Temperature Range
TJ
-40to+200
℃
TSTG
-40to+200
℃
Storage Temperature Range
10
uA
500
REV. 1, 06-Arp-2012
RATING AND CHARACTERISTIC CURVES
PD5002P(N) thru PD5006P(N)
FIG.2-MAXIMUM NON-RETETITIVE PEAK
FORWARD SURGE CURRENT
80
600
PEAK FORWARD SURGE CURRENT
AMPERES
AVERAGE FORWARD RECTIFIED CURRENT ,
AMPERES
FIG.1-FORWARD CURRENT
DERATING CURVE
70
60
50
40
30
60Hz Resistive or
Inductive load
20
10
500
400
300
Pulse Width 8.3ms Single
Half-Wave (JEDEC
Method)
200
100
0
0
0
50
100
150
200
NUMBER OF CYCLES AT 60HZ
CASE TEMPERATURE,
℃
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
FIG.3 -TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
1000
1000
T J=175℃
INSTANTANCEOUS REVERSE CURRENT,
MICRAMPERES
INSTANTANCEOUS FORWARD CURRENT,
AMPERES
100
10
1
250
100
10
T J=25℃
PULSE WIDTH=300S
1%DUTY CYCLE
1
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
INSTANTANEOUS FORWARD VOLTAGE,VOLTS
100
10
1
0.1
T J=25℃
0.01
0
20
40
60
80
100
PERCENT OF RATED PEAK REVERSE VOLTAGE,
%
REV. 1, 06-Arp-2012