INNOVASIC FIDO2100

fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
fido2100 3-Port Industrial Ethernet DLR Switch
with IEEE 1588
Data Sheet
1
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Copyright
April 10, 2013
2013 by Innovasic, Inc.
Published by Innovasic, Inc.
5635 Jefferson St. NE, Suite A, Albuquerque, New Mexico 87109 USA
fido® is a trademark of Innovasic, Inc.
2
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
TABLE OF CONTENTS
1
Overview ............................................................................................................................... 7
1.1 Introduction to Device Level Ring Protocol ................................................................ 8
1.2 Introduction to IEEE-1588........................................................................................... 9
2
Features ............................................................................................................................... 10
2.1 IEEE 802.3 MAC Details .......................................................................................... 11
2.1.1 IEEE 802.3 Full Duplex Flow Control ..................................................... 12
2.1.2 Half Duplex Flow Control and Broadcast/Multicast Storm Prevention ... 13
2.2 IEEE 1588 V2 ............................................................................................................ 13
2.2.1 IEEE 1588 Hardware Assist for Ordinary Clock ...................................... 13
2.2.2 IEEE 1588 End to End Transparent Clock ............................................... 16
2.3 Device Level Ring (DLR) Protocol Support ............................................................. 17
2.3.1 Network Loops .......................................................................................... 18
2.4 Cut Through Forwarding ........................................................................................... 18
2.5 Quality of Service ...................................................................................................... 19
2.6 Unicast and Multicast Address Filtering ................................................................... 19
2.7 Statistics Counters...................................................................................................... 20
2.8 Buffer Management ................................................................................................... 20
2.9 Supported Network Topologies ................................................................................. 21
3
LQFP Package ..................................................................................................................... 25
3.1 LQFP Package Pinout ................................................................................................ 25
3.2 LQFP Pin Listing ....................................................................................................... 26
3.3 LQFP Package Physical Dimensions ......................................................................... 30
4
BGA Package ...................................................................................................................... 31
4.1 BGA Package Pinout ................................................................................................. 31
4.2 BGA Pin Listing ........................................................................................................ 32
4.3 BGA Package Physical Dimensions .......................................................................... 36
5
Electrical Characteristics ..................................................................................................... 37
5.1 Thermal Characteristics ............................................................................................. 38
5.2 PLL Supply ................................................................................................................ 38
5.3 System Clock Input .................................................................................................... 38
5.4 RESET: Power-On-Reset, Hardware Reset and Software Reset ............................... 39
5.4.1 Power-On-Reset ........................................................................................ 39
3
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
5.5
April 10, 2013
5.4.2 Hardware Reset ......................................................................................... 39
5.4.3 Software Reset .......................................................................................... 39
Test Input ................................................................................................................... 39
6
Host Bus Interface ............................................................................................................... 40
6.1 READ, Host Bus Interface......................................................................................... 40
6.2 WRITE, Host Bus Interface ....................................................................................... 41
7
External MII Interface ......................................................................................................... 42
7.1 RECEIVE DATA, External MII Interface ................................................................ 42
7.2 TRANSMIT DATA, External MII Interface ............................................................. 43
8
Internal MII Interface .......................................................................................................... 43
8.1 RECEIVE DATA, Internal MII Interface.................................................................. 44
8.2 TRANSMIT DATA, Internal MII Interface .............................................................. 45
9
Control and Status Registers ............................................................................................... 46
9.1 Register Map .............................................................................................................. 46
9.2 Detailed Register Explanations .................................................................................. 51
10
Revision History .................................................................................................................. 84
11
For Additional Information ................................................................................................. 84
4
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
LIST OF FIGURES
Figure 1 fido2100 Top Level Block Diagram ................................................................................. 7
Figure 2 IEEE 1588 Hardware Assist Block Diagram ................................................................. 14
Figure 3 Hierarchical Start Topology ........................................................................................... 21
Figure 4 Hybrid Daisy Chain and Hierarchical Star Topology .................................................... 22
Figure 5 Ring Topology Media Redundancy ................................................................................ 23
Figure 6 fido2100 LQFP Package Pinout ..................................................................................... 25
Figure 7 LQFP Package Physical Dimensions ............................................................................. 30
Figure 8 fido2100 BGA Package Pinout....................................................................................... 31
Figure 9 BGA Package Physical Dimensions ............................................................................... 36
Figure 10 Host Interface, READ Timing ...................................................................................... 40
Figure 11 Host Interface, WRITE Timing .................................................................................... 41
Figure 12 External MII Interface, RECEIVE DATA ................................................................... 42
Figure 13 External MII Interface, TRANSMIT DATA ................................................................ 43
Figure 14 Internal MII Interface, RECEIVE DATA .................................................................... 44
Figure 15 Internal MII Interface, TRANSMIT DATA ................................................................. 45
5
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
LIST OF TABLES
Table 1 128-Pin LQFP Pin List..................................................................................................... 26
Table 2 BGA Pin List.................................................................................................................... 32
Table 3 Absolute Maximum Ratings ............................................................................................ 37
Table 4 ESD and Latch-Up Characteristics .................................................................................. 37
Table 5 Recommended Operating Conditions .............................................................................. 37
Table 6 DC Characteristics of I/O Cells ....................................................................................... 37
Table 7 Power Consumption (Nominal) ....................................................................................... 38
Table 8 Thermal Resistance Characteristics ................................................................................. 38
Table 9 Host Interface, READ Timing ......................................................................................... 40
Table 10 Host Interface, WRITE Timing ..................................................................................... 41
Table 11 RECEIVE DATA, External MII Interface..................................................................... 42
Table 12 TRANSMIT DATA, External MII Interface ................................................................. 43
Table 13 RECEIVE DATA, External MII Interface..................................................................... 44
Table 14 TRANSMIT DATA, External MII Interface ................................................................. 45
Table 15 Register Map .................................................................................................................. 46
Table 16 Document Revision History........................................................................................... 84
6
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
1 Overview
The fido2100 is part of the Innovasic fido® family of real-time communication products. The fido2100
is a managed, 3-port Ethernet switch with support for IEEE-1588 and Device Level Ring (DLR)
protocol. The fido2100 enhances the capabilities of Innovasic’s line of Industrial Ethernet products by
providing an infrastructure element with low latency, time synchronization and redundancy for any
embedded Industrial Ethernet solution.
The fido2100 is an IEEE 802.3 standard compliant, Layer 2 switch that is compatible with the IEEE
802.1D standard. It has three ports: two are external ports that function as physical ports of a product
and one is an internal port that connects to the host CPU. Each of the three ports has an IEEE 802.3
compliant MAC and the ports are interconnected with each other through full wire speed, non-blocking
switching logic. Figure 1 illustrates the top-level blocks of the fido2100 architecture.
Figure 1 fido2100 Top Level Block Diagram
7
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
The pass-through of traffic is handled swiftly by using cut through forwarding to pass traffic to the
other external port. This is accomplished without host CPU intervention, which keeps throughput time
host interaction to a minimum and keeps pass through delay to a minimum.
The fido2100 also has the ability to operate in a DLR configuration, which provides media redundancy
amongst its members. Host CPU source code is available to provide the ability for the device to be a
DLR participant or a DLR supervisor using the DLR support functions. The fido2100 will default to
linear topology operation, and when inserted into a ring, will automatically change to DLR operation as
a DLR participant.
1.1
Introduction to Device Level Ring Protocol
There are a variety of Industrial applications in which Ethernet ring topologies are preferable to the star
topologies common in enterprise networks. Ring networks provide inherent single-point fault tolerance
and reduced connectivity costs. Device Level Ring (DLR) protocol provides a means for detecting,
managing and recovering from faults in a ring-based network.
DLR supports three classes of devices:
1 Ring Supervisor – Ring Supervisors are required to send and process DLR beacon frames at the
default beacon interval.
2 Ring Node, Beacon-based – These devices are required to process beacon frames.
3 Ring Node, Announce-based – These devices are not required to process DLR beacon frames,
but must be capable of processing announce frames.
A DLR network consists of a Ring Supervisor and any number of Ring Nodes. Ring nodes incorporate
fido2100 technology with at least two external ports. The Ring Supervisor is responsible for generating
a “beacon” at regular intervals. These beacons traverse the ring in each direction. The ring supervisor
must be capable of blocking DLR frames to avoid infinite propagation of beacons. Faults are detected
when beacon traffic is interrupted. There are obviously a number of failure mechanisms and associated
recovery strategies. For a detailed explanation of DLR refer to ODVA documentation - Volume II:
EtherNet/IP Adaptation of CIP, chapter 9, section 9-5. For definition of the DLR EtherNet/IP object,
refer to Volume II: EtherNet/IP Adaptation of CIP, chapter 5, section 5-5.
8
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
1.2
April 10, 2013
Introduction to IEEE-1588
The IEEE 1588 standard, also known as Precision Time Protocol (PTP), provides a means to
synchronize participants in a network to a common time source. Each network participant has its own
precision time source or “ordinary clock”. A PTP system consists of some number of ordinary clocks
connected to a network. A grandmaster is elected based upon the quality of available time sources and
all other participants synchronize directly to it.
PTP systems can be expanded through the use of “boundary clocks”. The boundary clock provides a
means to bridge synchronization from one network segment to another. A synchronization master can
then be elected for each network segment. The root timing reference remains the grandmaster.
PTP is a master-slave protocol. The master and network participants exchange synchronization
messages. However, these messages will be delayed as they traverse the network due to the inherent
latency of the network infrastructure. To compensate for this latency, PTP includes the concept of a
transparent clock. The transparent clock automatically compensates for latency by modifying the
timestamps in synchronization messages as they pass through a given device. The fido2100 provides
hardware support for both transparent and ordinary clocks.
9
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
2
April 10, 2013
Features
IEEE 802.3
 10/100Mbps, Half / Full Duplex
 Full Duplex Flow Control
 Half Duplex Back Pressure Flow Control
 Broadcast / Multicast Storm Prevention
IEEE 1588 V2
 Hardware Assist for Ordinary Clock
 End-to-end Transparent Clock
DLR Beacons
 Capability to processes beacons from 100 ms down to 100 μs
 Provides auto-generation of beacon frames for supervisor functions
Cut through forwarding
 Cut through forwarding minimizes latency for High Performance Control
 Applications such as CIP Motion
IP Differentiated Services Code Point (DSCP) based Quality of Service (QoS)
 4 Prioritized Queues per Port
Incoming Filtering on Unicast / Multicast Traffic
 256-entry Dynamic Unicast MAC Learning and Filtering for 2 External Ports
 128 buffers of 128 bytes for each port
Statistics Counters for 2 External Ports
Supported Network topologies:
 Hierarchical Star with either one of the external ports
 Daisy Chain / Hybrid Daisy Chain Hierarchical Star
 DLR Media Redundancy with Hardware Support for a Single Fault Tolerant Ring
Protocol

Software for Switch & DLR Protocol Management


Full Industrial Temperature Range -40 to +85C
Packages:
 128 pin Plastic Low Profile QFT (LQFP), RoHS Compliant
 128 Ball Grid Array ( 10x10mm BGA), RoHS Compliant
10
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
2.1
April 10, 2013
IEEE 802.3 MAC Details
The fido2100 implements an IEEE 802.3 standard compliant MAC for each of the three ports. While
beginning a transmission, the MAC will transmit 7 bytes of preamble pattern 0x55, followed by one
byte of start of frame delimiter 0xD5, followed by the frame data and frame check sequence as per
IEEE 802.3 specification.
While transmitting, the MAC will enforce an inter-frame gap period of 960 ns at 100Mbps speed and
9.6 ns at 10Mbps speed as per IEEE 802.3 specification. While receiving, the MAC can tolerate
shrinkage of the inter-frame gap period down to 80 nanoseconds at 100Mbps speed and 800
nanoseconds at 10Mbps speed.
In full duplex mode the MAC will ignore carrier sense and collision detect signals from the PHY and is
ready to transmit after satisfying the inter-frame gap period as per IEEE 802.3 specification. In half
duplex mode, the MAC will wait for the current transmission to complete and the carrier sense signal to
be de-asserted. Then it will monitor if the carrier sense signal gets asserted in the first 2/3 duration of
the inter-frame gap period. If the carrier signal gets asserted within that period, the MAC will wait until
the carrier sense signal gets de-asserted to restart inter-frame gap period again. If the carrier sense
signal gets asserted in the last 1/3 duration of the inter-frame gap it will be ignored as per the IEEE
802.3 specification. The MAC is ready for transmission at the end of the inter-frame gap period. If a
frame is not available for transmission at the end of the inter-frame gap, the carrier sense signal will be
monitored for restarting inter-frame gap period.
If the frame transmission has commenced in half duplex mode and the collision signal gets asserted by
the PHY, transmission of the current frame data will be truncated with a jam pattern of 4 bytes of 0xFF.
At this point the collision back off and retransmission procedure will start using the truncated binary
exponential back off algorithm as per IEEE 802.3 specification. At the end of enforcing a jamming
pattern, the MAC will impose a delay before attempting to retransmit the frame. The delay is an integer
multiple of a slot time, where one slot time is equal to 512 bits time. The number of slot times to delay
before the nth retransmission attempt is chosen as a uniformly distributed random integer r in the range:
0 ≤ r < 2k; where k = min (n, 10)
If sixteen transmission attempts fail with collision for the same frame, the frame will be dropped as per
IEEE 802.3 specification. The mechanism used to generate the uniformly distributed random number is
a free running 10 bit wide linear feedback shift register (LFSR). The LFSR will cycle through all states
in 1024 transmit clocks of the port under consideration. Depending on the retransmission attempt
number n, the most significant k bits of LFSR are used as delay integer r. Due to the free running
nature of the LFSR, lock step random number generation in two different devices should not occur.
However, a facility is provided whereby the firmware can load a random seed value into the LFSR
anytime during operation.
11
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
The MAC will drop frames received with errors signaled by the PHY device and those with frame
check sequence (CRC) errors. It will drop frames shorter than 64 bytes as per IEEE 802.3 specification.
It will drop frames longer than maximum IEEE 802.3 tagged frame size of 1522 bytes. The MAC will
also drop frames with alignment error, i.e. those having a non-integral number of bytes.
2.1.1 IEEE 802.3 Full Duplex Flow Control
The fido2100 implements IEEE 802.3 compliant full duplex flow control using PAUSE frames. In
order to provide optimum performance, a special set of rules are followed for PAUSE frame generation
and reception.
PAUSE frame reception is enabled on external ports operating in full duplex mode and transmission on
the port through which the PAUSE frame was received will be suspended for specified pause duration
in the PAUSE frame. PAUSE frame reception is always disabled on the internal port, since the host
CPU will always have enough memory for its communications.
If speed and duplex modes of external ports are same and when buffer usage on either one of external
ports reaches 95% of buffer capacity, a PAUSE frame will be generated from internal port to host CPU
with maximum pause duration. If the buffer situation has not improved at the end of pause duration,
additional PAUSE frames will be generated from internal port as needed. When buffer usage on both
external ports reaches below 85% of buffer capacity, a PAUSE frame will be generated on internal port
with zero pause duration to cancel pause. If speed and duplex modes of external ports are not same,
PAUSE frames will not be generated.
For external ports, PAUSE frame generation on a port is enabled only for full duplex mode and when
both external ports have same speed and duplex settings. When a first external port is operating in full
duplex mode and buffer usage on internal port or second external port reaches 95% of buffer capacity a
PAUSE frame will be generated on first external port with maximum pause duration. If the buffer
situation has not improved at the end of pause duration, additional PAUSE frames will be generated
from first external port as needed. When buffer usage on both internal and second external ports
reaches below 85% of buffer capacity, a PAUSE frame will be generated on first external port with
zero pause duration to cancel pause. If speed and duplex modes of external ports are not same, PAUSE
frames will not be generated.
Obviously, for flow control on fido2100 to work properly, the integrated MAC on host CPU must
support flow control as well. Most Ethernet microprocessors do support this capability and dual port
product designer must ensure that the selected host CPU supports flow control.
12
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
2.1.2 Half Duplex Flow Control and Broadcast/Multicast Storm Prevention
The fido2100 implements back pressure flow control in half duplex mode. When both external ports
are operating in same speed and half duplex mode, and buffer usage on the internal port or other
external port reaches 95% of buffer capacity, back pressure flow control is activated on the first
external port. This continues until the buffer usage on both internal and second external ports reaches
below 85% of buffer capacity. When back pressure flow control is activated on a port, the port will
continue to transmit frames while it has any. If there is no frame to transmit, the frame will keep the
carrier sense signal active by sending the preamble pattern periodically, causing the neighboring node
to back off from transmitting any frames. If speed and duplex modes of external ports are not same,
back pressure will not be activated.
Excessive broadcast frames can overload the CPU of all devices on network, especially IO adapters and
IO blocks, leading to poor performance. To avoid this, the fido2100 implements a broadcast storm
prevention mechanism. When received broadcast data within a 100 millisecond period (1 second at
10Mbps) reaches about 1% of network bandwidth in a port operating at 100Mbps speed, additional
broadcast frames received on that port within that period will be dropped. This process is repeated for
every 100 millisecond period. In well-engineered networks, broadcast storms do not occur during
normal operation and a 1% broadcast storm limit will never be reached.
Similarly every port is also monitored for received non-redundancy (non-DLR/BRP) multicast frames.
When received non-redundancy multicast data within a 10 millisecond period (100 milliseconds at
10Mbps) reaches about 50% of network bandwidth in a port operating at 100Mbps speed, additional
nonredundancy multicast frames received on that port within that period will be dropped. This process
is repeated for every 10 millisecond period. In well-engineered networks, multicast storms do not occur
during normal operation.
2.2
IEEE 1588 V2
2.2.1 IEEE 1588 Hardware Assist for Ordinary Clock
Figure 2 below shows a block diagram of the IEEE 1588 V2 hardware assist that can be used to
implement an IEEE 1588 ordinary master or slave clock on an end device. The MII traffic of the
internal port between the host CPU and the fido2100 is monitored by two independent 1588 frame
detection logic blocks, one for the transmit channel and the other for the receive channel.
Whenever the timestamp point of a passing transmit/receive frame is reached, a snapshot of the system
time counter is saved in a temporary register. When the appropriate 1588 frame type is also detected in
the frame, the snapshot is saved from the temporary register to the transmit/receive snapshot register.
The receive snapshot register contains a sixteen entry FIFO, while the transmit snapshot register is a
13
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
single entry register. With the transmit snapshot register, the snapshot will be locked to prevent
overwriting by subsequent frames. The firmware must later clear the lock after it has read the snapshot.
With the receive snapshot register, the firmware should read all snapshots while the FIFO is not empty.
If the FIFO becomes full because the firmware is slow to read it, additional snapshots will not be saved
until the FIFO has a free entry. To distinguish saved snapshots, the received frame sequence identifier
and source port identity are also locked in the FIFO and may be read through appropriate registers
along with the snapshot.
Figure 2 IEEE 1588 Hardware Assist Block Diagram
The supported frame mapping for frame detection logic is PTP over UDP over IPV4 over IEEE 802.3
tagged or untagged frames. The frames detected are based on the master mode bit setting in the time
sync control register. In master mode, Sync frames are time stamped on transmit and Delay_Req
frames are time stamped on receive. In slave mode, Delay_Req frames are time stamped on transmit
and Sync frames are time stamped on receive. In addition, the sub-domain field of frames must match
the subdomain configuration register for the snapshot to be saved.
The addend register, accumulator and system time counter comprise a frequency compensated clock
under firmware control. The accumulator adds the addend register to itself on every incoming clock
from the oscillator and the overflow signal of the accumulator causes the system time counter to
increment. This provides a high precision tunable digital clock whose frequency of operation can be
controlled by firmware through writing suitable values to the addend register.
14
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
While transmit and receive frame detection logic operate independently at 25MHz MII clock rates, the
rest of the logic operates at 100MHz clock rate. The addend register and accumulator of frequency
compensated clock are 32-bits wide, while the system time counter is 64-bits wide. The tunable
precision for frequency compensation is better than 1 part per billion (1x10-9). The procedure for
realizing various nominal system time frequencies is described below.
FreqOscillator is the clocking frequency of the time synchronization
FreqClock is the nominal frequency at which the system time counter is to be incremented.
FreqDivisionRatio = FreqOscillator / FreqClock (This must always be > 1)
FreqCompensationValue = frequency compensation value is the number held in the
addend register, which is added to the accumulator once every 1/FreqOscillator.
The equation for the FreqCompensationValue utilizes the precision of the accumulator and the
FreqDivisionRatio. Since the accumulator is 32 bits, the following equation provides the value for the
Addend register:
FreqCompensationValue = 232 / FreqDivisionRatio
The hexadecimal representation of the FreqCompensationValue is the value that is written to the
addend register. The following table gives examples of addend values based on a 100 MHz
FreqOscillator.
Freq-oscillator
FreqClock
FreqDivisionRatio
FreqCompensationValue
100 MHz
83.33 MHz
1.2
0xD5555555
100 MHz
80 MHz
1.25
0xCCCCCCCD
100 MHz
66.66 MHz
1.5
0xAAAAAAAB
The synchronization accuracy between the time master and the slave depend on cumulative accuracy of
individual components used in the system. When a time slave is connected directly to the time master,
a synchronization accuracy of less than 50 ns from master is easily possible. This accuracy is
achievable with low cost 50PPM crystal clock oscillators. Turbulent air flow over the crystal oscillator
should be avoided to prevent rapid temperature changes resulting in short term stability errors. Some
PHY devices introduce random delays in transmit and receive paths, which can increase time
synchronization errors significantly. It is recommended that the PHY devices be investigated for such
behavior. Any asymmetry in transmit and receive paths should be accounted properly by firmware to
avoid accumulation of errors. In a cascaded transparent clock configuration between the time master
and the slave, the errors will increase linearly with the number of transparent clocks.
15
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
There are two 64-bit target time registers and comparators that can be used to generate an interrupt to
the host CPU when the system time counter reaches the target time. This feature can be used by
firmware to schedule/coordinate control loops/activities. While both target time registers can be used
by firmware for any purpose, the second target time register has a special capability to generate a pulse
per second signal. The pulse per second signal is required for internal IEEE 1588 compliance testing,
but is not required on shipping products.
There are two additional snapshot registers for two external events. These snapshots can be used to
synchronize system time with an external clock. For example, the event 1 can be used to synchronize
internal IEEE 1588 system time as a slave with a global positioning system (GPS) signal as the master.
Similarly, the event 2 can be used to synchronize internal IEEE 1588 system time as a master with an
external clock in another module in the system as the slave. Both event snapshots have the same
capability/behavior in implementation and they can be used interchangeably.
2.2.2 IEEE 1588 End to End Transparent Clock
The fido2100 implements an integrated IEEE 1588 V2 end to end transparent clock (E2E TC). This is a
single step transparent clock in IEEE 1588 terminology. The supported frame mapping is PTP over
UDP over IPV4 over IEEE 802.3 tagged or untagged frames. The E2E TC uses a non-syntonized free
running timer as a time base. The free running timer runs at 100MHz, but the timestamp circuit uses
both edges of the clock for sampling, and delay computation is suitably adjusted to make it effectively
run at 200MHz, with 5 ns resolution.
In E2E TC mode, whenever an IEEE 1588 V2 Sync or Delay_Req frame is received, a receive
timestamp is triggered on ingress at the timestamp point following the start of frame delimiter. The
frame is parsed to extract the UDP checksum and correction field. When the received frame doesn’t
contain any errors and when the frame is transmitted through a port, a transmit timestamp is triggered
on egress at the timestamp point. The residence time delay is then computed on the fly from the
transmit and receive timestamps. The residence time delay is then added to the correction field in the
frame with the UDP checksum and frame CRC adjusted on the fly.
Without transparent clocks, cascaded switches or boundary clocks will accumulate errors at
exponential rate making time synchronization unstable. With transparent clocks the accumulation of
errors is linear with the number of nodes. The implemented E2E TC has a theoretical worst case error
of +/-15 ns per node assuming 50PPM source crystal oscillator stability.
16
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
2.3
April 10, 2013
Device Level Ring (DLR) Protocol Support
The fido2100 provides hardware support for a single-fault tolerant ring protocol. The DLR protocol
support for non-supervisor mode and support for supervisor mode can be enabled by setting appropriate
bits in the redundancy control register.
In non-supervisor mode, received non-erroneous DLR beacon frames from the active ring supervisor
through either port will be automatically dropped after extracting state information and restarting the
DLR beacon timers. Received non-erroneous DLR beacon frames may optionally be configured to be
delivered to the host CPU by setting appropriate bits in the redundancy control register. Irrespective of
this bit setting, beacon messages received from a different supervisor than active supervisor are always
forwarded to host CPU. The fido2100 can be configured to interrupt host CPU when ring beacon
frames from active supervisor are received through either port or are not received through either port
within ring beacon timeout period. The fido2100 can also be configured to interrupt host CPU when a
change of state is observed in ring beacon frames from active ring supervisor received through either
port. Neighbor check and multicast sign on frames received from either external port will be forwarded
only to host CPU and those from host CPU will be forwarded only through port number matching
source port number field in frame. Source identifier and sequence identifier fields of received neighbor
check frames are captured to identify received port later. Unicast sign on frames are treated as any
other unicast frame.
In supervisor mode, either one of the external ports can be placed in blocked mode by setting
appropriate port transmit/receive blocked bits in redundancy control register. All frame reception and
transmission will be blocked by the port in blocked mode with the exception of some special frames.
These special frames are described under port transmit/receive blocked bits in redundancy control
register. In supervisor mode, ring beacon frames can be automatically generated and transmitted
through unblocked ports to reduce the CPU load and their arrival through both ports are monitored. The
fido2100 can be configured to interrupt the host CPU when DLR beacon frames are received through
either port or are not received through either port within DLR beacon timeout period. The fido2100 can
also be configured to interrupt the host CPU when a change of state is observed in DLR beacon frames
are received from the active ring supervisor through either port. Received non-erroneous DLR beacon
frames may optionally be configured to be delivered to host CPU by setting appropriate bits in
redundancy control register. Irrespective of this bit setting, beacon messages received from a different
supervisor than self is always forwarded to host CPU.
In supervisor mode, neighbor check and multicast sign on frames received from either external port
will be forwarded only to the host CPU, and those from the host CPU will be forwarded only through
the port number matching the source port number field in the frame. The source identifier and sequence
identifier fields of received neighbor check frames and sign on frames are captured to identify the
received port later. Link/neighbor status frames received from either external port will be forwarded
17
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
only to the host CPU. The source identifier and sequence identifier fields of received link/neighbor
status frames are captured to identify the received port later.
2.3.1 Network Loops
The fido2100 has a built in safety feature to detect network loops. Undetected, network loops can cause
severe network problems. Network loops may be present when the user inadvertently misconnects the
network in such a way as to create a loop or when the user intentionally creates a DLR topology, but
fails to configure a DLR supervisor. When a frame is received through one of the external ports with
the source MAC address the same as the MAC address of the host CPU, the fido2100 will drop that
frame and will set a port-specific bit in the switch event register indicating that such a frame was
received. These bits can be read and cleared by firmware and can be used to flag the network fault
situation to the user. Alternatively, the fido2100 can be configured to interrupt the host CPU when
those bits are set.
It should be noted that in a properly configured DLR with a DLR supervisor, network loops may be
present for short durations when the network is being reconfigured. Hence firmware should not flag the
user of this fault condition when operating in proper DLR mode. The firmware can detect the proper
DLR mode by the presence of DLR beacons on the network, whereas in non-DLR mode or an
improperly configured DLR mode, DLR beacons would be absent on network.
2.4
Cut Through Forwarding
The fido2100 implements cut through forwarding with store and forward on contention at the
transmitting port. COTS switches and standard switching integrated circuits typically support only the
store and forward approach. With the store and forward approach a frame has to be completely
received before being transmitted. Hence every frame will encounter a delay equal to the length of the
frame and additional internal switching delay. This can become an issue for high performance
applications such as CIP motion when a long chain of cascaded switches are involved, such as in daisy
chain or DLR topology networks.
With cut through forwarding, when frame reception begins and when a sufficient number of bytes of a
frame have been buffered, the frame is queued for transmission, subject to the following forwarding
rules:
1. If the transmitting port is idle and ready for transmission, it will immediately start frame
transmission while the reception is in progress.
2. If the transmitting port is not free immediately, it will start transmitting as soon as the port
becomes ready for transmission, while the reception is in progress.
3. If the transmitting port doesn’t become available before the entire frame is received, the
received frame will be buffered completely for store and forward.
18
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
Because of cut through forwarding, non-IP frames from all transmit queues and IP frames from
transmit queues 2 and 3 will face a delay of 2.8 µs, other non-IEEE 1588 frames will face a delay of
4.9 µs and IEEE 1588 time synchronization frames will face a delay of 7.3 µs through the fido2100,
when the transmitting port is free of contention. Cut through forwarding is disabled for a transmit port
when the receiving port is operating at 10Mbps speed and the transmitting port is operating at 100Mbps
speed. In this case, store and forward is used.
2.5
Quality of Service
In order to support high performance applications such as CIP motion, the fido2100 enforces quality of
service based on IP Differentiated Services Code Point (DSCP). The fido2100 implements four
prioritized transmit queues per port. Frames received with DSCP 59 are queued in the highest priority
transmit queue (queue #1). Frames received with DSCP 55 are queued in the second highest priority
transmit queue (queue #2). Frames received with DSCP 47 and 43 are queued in the third highest
priority transmit queue (queue #3). Frames received with other DSCP values are queued in the lowest
priority transmit queue (queue #4). In addition, DLR protocol frames are queued in the highest priority
queue 1. When a port is ready to transmit the next frame, the highest priority frame is chosen from the
current set of queued frames for transmission based on strict priority ordering. Within a given priority
queue frames are transmitted in FIFO order.
2.6
Unicast and Multicast Address Filtering
The fido2100 implements 256 entry dynamic unicast MAC address learning and filtering mechanism.
The unicast MAC address learning table is implemented as 4-way learning/look up table of 64 rows.
The 48-bit source MAC address from a frame received on any external port is hashed into 6-bits by
XOR operation of every sixth bit. The hash index identifies the row where one of four locations that is
free is used for MAC address learning along with associated external port. When none of them is free,
the 4th way location is always overwritten. Learning is performed on source MAC address only from
frames with a unicast or multicast destination MAC address. Automatic aging of learned entries will
happen in 4- 6 minutes, unless learning is refreshed within that period.
When a frame with unicast destination address is received through any port, 4-way simultaneous
lookup is performed from entries at hash index location of destination MAC address. If the address is
found, the frame is forwarded only through associated external port. If the address is not found, then it
is forwarded through all other external ports. When a frame with unicast destination address is received
through one of the external ports and the destination address matches host CPU MAC address, then that
frame is forwarded only to internal port.
The fido2100 implements multicast filtering on the internal port for frames received through external
ports and no multicast filtering is implemented for the external ports. The multicast filter consists of a
2048 bin hash table. The received multicast destination address is passed through a 32-bit Ethernet
19
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
CRC generator and the least significant 11 bits of the resulting CRC is used to index into the 2048 bin
hash table. When the indexed bin in the hash table is set, the frame will be forwarded to the internal
port and the other external port. If not set, the frame will be forwarded only to the other external port.
By default, all 2048 bins of the multicast hash table are set to zero after power up or chip reset, and no
multicast frames will be forwarded to the internal port. Since most devices such as I/O devices don’t
need to receive multicast frames, they don’t need to change this default behavior. Note that the
multicast filter table need not be set for receiving multicast ring frames.
2.7
Statistics Counters
The fido2100 implements statistics counters for the external ports. These counters can be used by
firmware for the media and interface counters of the EtherNet/IP Ethernet Link object (Class Code:
0xF6). Most of these counters are 16 bits wide and to avoid roll over issues, firmware must read these
registers at least once every 200 milliseconds or on demand, to calculate an increase in counter values.
The firmware can then add the increase to firmware maintained 32 bit counters.
Counters are implemented for valid frames received with the group bit set in the destination address,
valid frames received with a unicast destination address, total byte count of valid frames received,
frames received with length greater than 1522 bytes, frames received with alignment error, frames
received with a frame check sequence (CRC) error and frames received with other errors, including
short runt frames less than 64 bytes in length.
Counters are also implemented for valid frames transmitted with the group bit set in the destination
address, valid frames transmitted with a unicast destination address, total byte count of valid frames
transmitted, frames transmitted after exactly one collision, frames transmitted after multiple collisions,
frames dropped due to excessive collisions and frames truncated with error during transmission.
2.8
Buffer Management
The fido2100 implements an efficient packet buffering scheme using on board dual port SRAM
memory. The buffers are 128 bytes in size to minimize memory wastage. Frames longer than 128 bytes
are automatically fragmented to be stored in multiple buffers and reassembled during transmission.
Actual buffer usage depends on a number of factors such as network load, number of frames waiting to
be transmitted at each node at the same time, the number of back to back frames arriving at the
destination node through both external ports at the same time, etc. For some devices such as motion
drives and I/O, buffer usage on any port may never exceed 10% of buffer capacity. For other devices
such as network bridges, buffer usage on any port may be typically less than 50% of buffer capacity
during normal operation. Irrespective of the type of end device, when buffer usage reaches 95% of
buffer capacity on any port under heavily loaded network conditions, flow control will intervene to
reduce buffer usage and will ensure frames are not being dropped.
20
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
2.9
April 10, 2013
Supported Network Topologies
Dual port products designed with this toolkit can be used in a wide variety of network configurations.
This single hardware design will support various network topologies. Irrespective of the network
configuration used, a dual port end device will always have a single IP address and a single MAC
address. This simplifies both configuration requirements and firmware changes required.
Figure 3 shows hierarchical star topology with commercial off the shelf (COTS) switches. Either port
of a dual port end device may be used to connect to COTS switch to realize hierarchical star network
topology.
Figure 3 Hierarchical Start Topology
Figure 4 shows a hybrid daisy chain and hierarchical star topology. Single port end devices can be
connected to a daisy chain at one of the ends of the chain, or through a standalone three port device that
provides the daisy chain capability in the middle of chain. Figure 3 also shows a COTS switch in the
middle of a daisy chain.
21
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
Figure 4 Hybrid Daisy Chain and Hierarchical Star Topology
It should be noted that a slower speed or half duplex link on main daisy chain will become a bottle
neck, causing the entire network to operate at reduced capacity. Similarly, a single port device can be
connected to either end of main daisy chain network, only if it operates at same/better speed and duplex
mode as rest of the network. The recommended method for connecting slower speed/duplex devices is
through a three port tap device to avoid performance issues.
Figure 5 shows a ring topology media redundancy that can tolerate single faults. One or more DLR
supervisor(s) control the operation of ring. When multiple DLR supervisors are configured, one of
them will be automatically chosen as active supervisor. Others will be in passive mode, until the active
DLR supervisor fails or is removed from ring.
22
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
Figure 5 Ring Topology Media Redundancy
For IO applications, a COTS switch in the ring must support IEEE 802.3 tag based and IP DSCP based
QoS with at least two prioritized queues, preferably four prioritized queues. The highest priority queue
must be dedicated for ring protocol messages for predictable performance. For IEEE 1588 applications
such as CIP motion, COTS switches directly on ring must support IEEE 1588 end-to-end transparent
clock (or boundary clock) and IEEE 802.3 tag based and IP DSCP based QoS with four prioritized
queues. The highest priority queue may be shared between IEEE 1588 and ring protocol messages. If
not, COTS switches can be connected through three port tap device as shown in Figure 4.
23
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
The COTS switch must be configured so that ring protocol messages are not forwarded to devices
connected to it. IGMP snooping and multicast filtering must be disabled on 2 ports of the COTS switch
directly connected to ring to facilitate rapid network reconfiguration. Since unicast filtering cannot be
disabled in a COTS switch, it may take couple of CIP connection RPI’s for some data packets to be
delivered correctly on some nodes after a network reconfiguration. Ring timing parameters such as
beacon period and timeout must account for the presence of a COTS switch directly in ring. Typical
network recovery time for a ring containing 50 nodes will be less than 1 millisecond for most types of
faults on a loaded network with mostly EtherNet/IP frames. Further details of ring topology and
protocol are described in, “Device Level Ring Protocol”; see CIP Networks Library, Volume 2,
Chapter 9, Edition 1.7 or later (see www.odva.org for details).
It is possible to create complex ring topologies. Some examples are: a backbone ring connecting
multiple star topologies; a backbone star connecting multiple ring topologies; a backbone ring
connecting multiple ring topologies; and other combinations.
Most dual/three port devices operate as simple ring nodes and require no special configuration. By
default they will power up in daisy chain mode and transparently switch to ring mode upon receiving
beacon frames from ring supervisor.
24
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
3 LQFP Package
3.1
LQFP Package Pinout
The pinout for the fido2100 Industrial Ethernet Switch LQFP package is as shown in Figure 6. The
corresponding pinout is provided in Table 1.
Figure 6 fido2100 LQFP Package Pinout
25
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
3.2
April 10, 2013
LQFP Pin Listing
Table 1 128-Pin LQFP Pin List
Pin Signal Name
Type
1 sw_event_irq_n output
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
ts_event_irq_n
pps_sig
event_1_sig
event_2_sig
p1_txc
vcck
gndk
gndio
vcc3io
p1_txen
p1_txer
p1_txd[0]
p1_txd[1]
p1_txd[2]
p1_txd[3]
p1_rxc
p1_rxdv
p1_rxer
p1_rxd[0]
p1_rxd[1]
p1_rxd[2]
vcc3io
gndio
gndk
vcck
p1_rxd[3]
p1_col
p1_crs
p1_lnk_stts
p1_led_grn
p1_led_ylw
p2_txc
p2_txen
p2_txer
output
output
input
input
input
power
ground
ground
power
output
output
output
output
output
output
input
input
input
input
input
input
power
ground
ground
power
input
input
input
input
output
output
input
output
output
LQFP Pin Descriptions
switch event IRQ, must be connected to a high priority
IRQ pin on cpu
time sync event IRQ. Optional for non-1588 devices.
pulse per second signal for 1588 compliance
external event 1 snapshot trigger from CPU/others
external event 2 snapshot trigger from CPU/others
port 1 mii, transmit clock from PHY
1.8 V digital core supply voltage
digital core ground
i/o ground
3.3 V i/o supply voltage
port 1 mii, transmit enable to PHY
port 1 mii, transmit error to PHY
port 1 mii, transmit data bit 0 to PHY
port 1 mii, transmit data bit 1 to PHY
port 1 mii, transmit data bit 2 to PHY
port 1 mii, transmit data bit 3 to PHY
port 1 mii, receive clock from PHY
port 1 mii, receive data valid from PHY
port 1 mii, receive data error from PHY
port 1 mii, receive data bit 0 from PHY
port 1 mii, receive data bit 1 from PHY
port 1 mii, receive data bit 2 from PHY
3.3 V i/o supply voltage
i/o ground
digital core ground
1.8 V digital core supply voltage
port 1 mii, receive data bit 3 from PHY
port 1 mii, collision from PHY
port 1 mii, carrier sense from PHY
port 1 mii, link status from PHY (1:link pass, 0:link fail)
port 1 mii,, green led
port 1 mii,, yellow led
port 2 mii, transmit clock from PHY
port 2 mii, transmit enable to PHY
port 2 mii, transmit error to PHY
26
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Pin
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
Signal Name
p2_txd[0]
p2_txd[1]
p2_txd[2]
vcck
gndk
gndio
vcc3io
p2_txd[3]
p2_rxc
p2_rxdv
p2_rxer
gndo
vdd3o
p2_rxd[0]
p2_rxd[1]
p2_rxd[2]
p2_rxd[3]
p2_col
p2_crs
vcc3io
gndio
gndk
vcck
p2_lnk_stts
p2_led_grn
p2_led_ylw
reset_n
sys_clk
test
cpu_txen
vcc18a_pll
gnda_pll
cpu_txer
cpu_txc
cpu_txd[0]
vcck
gndk
gndio
vcc3io
cpu_txd[1]
Type
output
output
output
power
ground
ground
power
output
input
input
input
ground
power
input
input
input
input
input
input
power
ground
ground
power
input
output
output
input
input
input
input
power
ground
input
output
input
power
ground
ground
power
input
April 10, 2013
LQFP Pin Descriptions
port 2 mii, transmit data bit 0 to PHY
port 2 mii, transmit data bit 1 to PHY
port 2 mii, transmit data bit 2 to PHY
1.8 V digital core supply voltage
digital core ground
i/o ground
3.3 V i/o supply voltage
port 2 mii, transmit data bit 3 to PHY
port 2 mii, receive clock from PHY
port 2 mii, receive data valid from PHY
port 2 mii, receive data error from PHY
i/o ground
3.3 V i/o supply voltage
port 2 mii, receive data bit 0 from PHY
port 2 mii, receive data bit 1 from PHY
port 2 mii, receive data bit 2 from PHY
port 2 mii, receive data, bit 3 from PHY
port 2 mii, collision from PHY
port 2 mii, carrier sense from PHY
3.3 V i/o supply voltage
i/o ground
digital core ground
1.8 V digital core supply voltage
port 2 mii, link status from PHY (1:link pass, 0:link fail)
port 2 mii,, green led
port 2 mii,, yellow led
chip reset, active low (internal pull-up)
25 MHz system clock
test, active high (internal pull-down)
cpu mii, transmit enable from CPU
1.8 V analog supply voltage
analog ground
cpu mii, transmit error from CPU
cpu mii, 25 MHz transmit clock to CPU
cpu mii, transmit data bit 0 from CPU
1.8 V digital core supply voltage
digital core ground
i/o ground
3.3 V i/o supply voltage
cpu mii, transmit data bit 1 from CPU
27
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Pin
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
Signal Name
cpu_txd[2]
cpu_txd[3]
cpu_rxc
cpu_rxdv
vcc3o
cpu_rxer
cpu_crs
cpu_col
cpu_rxd[0]
cpu_rxd[1]
cpu_rxd[2]
vcc3io
gndio
gndk
vcck
cpu_rxd[3]
cpu_adrs[1]
cpu_adrs[2]
cpu_adrs[3]
cpu_adrs[4]
cpu_adrs[5]
cpu_adrs[6]
cpu_adrs[7]
cpu_adrs[8]
cpu_data[0]
cpu_data[1]
cpu_data[2]
vcck
gndk
gndio
vcc3io
cpu_data[3]
cpu_data[4]
cpu_data[5]
cpu_data[6]
cpu_data[7]
gndo
vcc3o
cpu_data[8]
cpu_data[9]
Type
input
input
output
output
power
output
output
output
output
output
output
power
ground
ground
power
output
input
input
input
input
input
input
input
input
bidir
bidir
bidir
power
ground
ground
power
bidir
bidir
bidir
bidir
bidir
ground
power
bidir
bidir
April 10, 2013
LQFP Pin Descriptions
cpu mii, transmit data bit 2 from CPU
cpu mii, transmit data bit 3 from CPU
cpu mii, 25 MHz receive clock to CPU
cpu_mii, receive data valid to CPU
3.3 V i/o supply voltage
cpu mii, receive error
cpu mii,
cpu mii, collision
cpu mii, receive data bit 0 to CPU
cpu mii, receive data bit 1 to CPU
cpu mii, receive data bit 2 to CPU
3.3 V i/o supply voltage
i/o ground
digital core ground
1.8 V digital core supply voltage
cpu mii, receive data bit 3 to CPU
cpu host interface, address bit 1
cpu host interface, address bit 2
cpu host interface, address bit 3
cpu host interface, address bit 4
cpu host interface, address bit 5
cpu host interface, address bit 6
cpu host interface, address bit 7
cpu host interface, address bit 8
cpu host interface, data bit 0
cpu host interface, data bit 1
cpu host interface, data bit 2
1.8 V digital core supply voltage
digital core ground
i/o ground
3.3 V i/o supply voltage
cpu host interface, data bit 3
cpu host interface, data bit 4
cpu host interface, data bit 5
cpu host interface, data bit 6
cpu host interface, data bit 7
i/o ground
3.3 V i/o supply voltage
cpu host interface, data bit 8
cpu host interface, data bit 0
28
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Pin
116
117
118
119
120
121
122
123
124
125
126
Signal Name
cpu_data[10]
cpu_data[11]
cpu_data[12]
vcc3io
gndio
gndk
vcck
cpu_data[13]
cpu_data[14]
cpu_data[15]
cpu_cs_n
Type
bidir
bidir
bidir
power
ground
ground
power
bidir
bidir
bidir
input
127 cpu_rd_n
input
128 cpu_wr_n
input
April 10, 2013
LQFP Pin Descriptions
cpu host interface, data bit 10
cpu host interface, data bit 11
cpu host interface, data bit 12
3.3 V i/o supply voltage
i/o ground
digital core ground
1.8 V digital core supply voltage
cpu host interface, data bit 13
cpu host interface, data bit 14
cpu host interface, data bit 15
cpu host interface, chip select, active low (internal pullup)
cpu host interface, read enable, active low (internal
pull-up)
cpu host interface, write enable, active low (internal
pull-up)
29
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
3.3
April 10, 2013
LQFP Package Physical Dimensions
Figure 7 LQFP Package Physical Dimensions
30
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
®
fido 2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
4 BGA Package
4.1
BGA Package Pinout
The pinout for the fido2100 Industrial Ethernet Switch BGA package is as shown in Figure 8. The corresponding pinout is provided in
Table 2.
M
p1_lnk_stts
p2_txc
p2_txd[0]
p2_txd[2]
p2_rxc
p2_rxdv
p2_rxd[0]
p2_rxd[2]
p2_col
p2_lnk_stts
p2_led_grn
reset_n
L
p1_col
p1_led_grn
p2_txen
p2_txd[1]
p2_txd[3]
p2_rxer
p2_rxd[1]
p2_rxd[3]
p2_crs
p2_led_ylw
sys_clk
cpu_txen
K
p1_rxd[2]
p1_crs
p1_led_ylw
p2_txer
vcck
vcc3io
vcc3io
vcc3io
vcck
test
cpu_txer
cpu_txd[0]
J
p1_rxd[1]
p1_rxd[3]
vcck
vcck
gndio
vcc18a_pll
cpu_txc
cpu_txd[2]
H
p1_rxer
p1_rxd[0]
vcc3io
gndio
gndk
gndk
gndio
gnda_pll
cpu_txd[1]
cpu_txd[3]
G
p1_rxc
p1_rxdv
vcc3io
gndio
gndk
gndk
gndio
vcck
cpu_rxc
cpu_rxdv
F
p1_txd[3]
p1_txd[2]
vcc3io
gndio
gndk
gndk
gndio
vcc3io
cpu_rxer
cpu_crs
E
p1_txd[1]
p1_txd[0]
vcck
gndio
gndk
gndk
gndio
vcc3io
cpu_rxd[0]
cpu_col
D
p1_txer
p1_txc
vcck
gndio
vcck
vcc3io
cpu_rxd[2]
cpu_rxd[1]
C
p1_txen
event_1_sig
sw_event_irq_n
cpu_cs_n
vcc3io
cpu_data[9]
cpu_data[5]
vcc3io
cpu_adrs[8]
cpu_adrs[5]
cpu_adrs[2]
cpu_rxd[3]
B
event_2_sig
ts_event_irq_n
cpu_rd_n
cpu_data[14]
cpu_data[12]
cpu_data[10]
cpu_data[6]
cpu_data[3]
cpu_data[1]
cpu_adrs[7]
cpu_adrs[4]
cpu_adrs[1]
A
pps_sig
cpu_wr_n
cpu_data[15]
cpu_data[13]
cpu_data[11]
cpu_data[8]
cpu_data[7]
cpu_data[4]
cpu_data[2]
cpu_data[0]
cpu_adrs[6]
cpu_adrs[3]
1
2
3
4
5
6
7
8
9
10
11
12
Figure 8 fido2100 BGA Package Pinout
31
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
4.2
April 10, 2013
BGA Pin Listing
Table 2 BGA Pin List
Pin
Signal Name
Type
C3 sw_event_irq_n output
B2
A1
C2
B1
D2
E3
E6
F5
F3
C1
D1
E2
E1
F2
F1
G1
G2
H1
H2
J1
K1
G3
G5
F6
J3
J2
L1
K2
M1
L2
K3
M2
ts_event_irq_n
pps_sig
event_1_sig
event_2_sig
p1_txc
vcck
gndk
gndio
vcc3io
p1_txen
p1_txer
p1_txd[0]
p1_txd[1]
p1_txd[2]
p1_txd[3]
p1_rxc
p1_rxdv
p1_rxer
p1_rxd[0]
p1_rxd[1]
p1_rxd[2]
vcc3io
gndio
gndk
vcck
p1_rxd[3]
p1_col
p1_crs
p1_lnk_stts
p1_led_grn
p1_led_ylw
p2_txc
output
output
input
input
input
power
ground
ground
power
output
output
output
output
output
output
input
input
input
input
input
input
power
ground
ground
power
input
input
input
input
output
output
input
BGA Pin Descriptions
switch event IRQ, must be connected to a high priority
IRQ pin on cpu
time sync event IRQ. Optional for non-1588 devices.
pulse per second signal for 1588 compliance
external event 1 snapshot trigger from CPU/others
external event 2 snapshot trigger from CPU/others
port 1 mii, transmit clock from PHY
1.8 V digital core supply voltage
digital core ground
i/o ground
3.3 V i/o supply voltage
port 1 mii, transmit enable to PHY
port 1 mii, transmit error to PHY
port 1 mii, transmit data bit 0 to PHY
port 1 mii, transmit data bit 1 to PHY
port 1 mii, transmit data bit 2 to PHY
port 1 mii, transmit data bit 3 to PHY
port 1 mii, receive clock from PHY
port 1 mii, receive data valid from PHY
port 1 mii, receive data error from PHY
port 1 mii, receive data bit 0 from PHY
port 1 mii, receive data bit 1 from PHY
port 1 mii, receive data bit 2 from PHY
3.3 V i/o supply voltage
i/o ground
digital core ground
1.8 V digital core supply voltage
port 1 mii, receive data bit 3 from PHY
port 1 mii, collision from PHY
port 1 mii, carrier sense from PHY
port 1 mii, link status from PHY (1:link pass, 0:link fail)
port 1 mii,, green led
port 1 mii,, yellow led
port 2 mii, transmit clock from PHY
32
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Pin
L3
K4
M3
L4
M4
J4
G6
H5
H3
L5
M5
M6
L6
J9
K6
M7
L7
M8
L8
M9
L9
K7
H8
H6
K5
M10
M11
L10
M12
L11
K10
L12
J10
H10
K11
J11
K12
K9
Signal Name
p2_txen
p2_txer
p2_txd[0]
p2_txd[1]
p2_txd[2]
vcck
gndk
gndio
vcc3io
p2_txd[3]
p2_rxc
p2_rxdv
p2_rxer
gndio
vcc3io
p2_rxd[0]
p2_rxd[1]
p2_rxd[2]
p2_rxd[3]
p2_col
p2_crs
vcc3io
gndio
gndk
vcck
p2_lnk_stts
p2_led_grn
p2_led_ylw
reset_n
sys_clk
test
cpu_txen
vcc18a_pll
gnda_pll
cpu_txer
cpu_txc
cpu_txd[0]
vcck
Type
output
output
output
output
output
power
ground
ground
power
output
input
input
input
ground
power
input
input
input
input
input
input
power
ground
ground
power
input
output
output
input
input
input
input
power
ground
input
output
input
power
April 10, 2013
BGA Pin Descriptions
port 2 mii, transmit enable to PHY
port 2 mii, transmit error to PHY
port 2 mii, transmit data bit 0 to PHY
port 2 mii, transmit data bit 1 to PHY
port 2 mii, transmit data bit 2 to PHY
1.8 V digital core supply voltage
digital core ground
i/o ground
3.3 V i/o supply voltage
port 2 mii, transmit data bit 3 to PHY
port 2 mii, receive clock from PHY
port 2 mii, receive data valid from PHY
port 2 mii, receive data error from PHY
i/o ground
3.3 V i/o supply voltage
port 2 mii, receive data bit 0 from PHY
port 2 mii, receive data bit 1 from PHY
port 2 mii, receive data bit 2 from PHY
port 2 mii, receive data, bit 3 from PHY
port 2 mii, collision from PHY
port 2 mii, carrier sense from PHY
3.3 V i/o supply voltage
i/o ground
digital core ground
1.8 V digital core supply voltage
port 2 mii, link status from PHY (1:link pass, 0:link fail)
port 2 mii,, green led
port 2 mii,, yellow led
chip reset, active low (internal pull-up)
25 MHz system clock
test, active high (internal pull-down)
cpu mii, transmit enable from CPU
1.8 V analog supply voltage
analog ground
cpu mii, transmit error from CPU
cpu mii, 25 MHz transmit clock to CPU
cpu mii, transmit data bit 0 from CPU
1.8 V digital core supply voltage
33
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Pin
H7
G8
K8
H11
J12
H12
G11
G12
F10
F11
F12
E12
E11
D12
D11
E10
F8
G7
G10
C12
B12
C11
A12
B11
C10
A11
B10
C9
A10
B9
A9
D9
F7
E8
D10
B8
A8
C7
Signal Name
gndk
gndio
vcc3io
cpu_txd[1]
cpu_txd[2]
cpu_txd[3]
cpu_rxc
cpu_rxdv
vcc3io
cpu_rxer
cpu_crs
cpu_col
cpu_rxd[0]
cpu_rxd[1]
cpu_rxd[2]
vcc3io
gndio
gndk
vcck
cpu_rxd[3]
cpu_adrs[1]
cpu_adrs[2]
cpu_adrs[3]
cpu_adrs[4]
cpu_adrs[5]
cpu_adrs[6]
cpu_adrs[7]
cpu_adrs[8]
cpu_data[0]
cpu_data[1]
cpu_data[2]
vcck
gndk
gndio
vcc3io
cpu_data[3]
cpu_data[4]
cpu_data[5]
Type
ground
ground
power
input
input
input
output
output
power
output
output
output
output
output
output
power
ground
ground
power
output
input
input
input
input
input
input
input
input
bidir
bidir
bidir
power
ground
ground
power
bidir
bidir
bidir
April 10, 2013
BGA Pin Descriptions
digital core ground
i/o ground
3.3 V i/o supply voltage
cpu mii, transmit data bit 1 from CPU
cpu mii, transmit data bit 2 from CPU
cpu mii, transmit data bit 3 from CPU
cpu mii, 25 MHz receive clock to CPU
cpu_mii, receive data valid to CPU
3.3 V i/o supply voltage
cpu mii, receive error
cpu mii,
cpu mii, collision
cpu mii, receive data bit 0 to CPU
cpu mii, receive data bit 1 to CPU
cpu mii, receive data bit 2 to CPU
3.3 V i/o supply voltage
i/o ground
digital core ground
1.8 V digital core supply voltage
cpu mii, receive data bit 3 to CPU
cpu host interface, address bit 1
cpu host interface, address bit 2
cpu host interface, address bit 3
cpu host interface, address bit 4
cpu host interface, address bit 5
cpu host interface, address bit 6
cpu host interface, address bit 7
cpu host interface, address bit 8
cpu host interface, data bit 0
cpu host interface, data bit 1
cpu host interface, data bit 2
1.8 V digital core supply voltage
digital core ground
i/o ground
3.3 V i/o supply voltage
cpu host interface, data bit 3
cpu host interface, data bit 4
cpu host interface, data bit 5
34
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Pin
B7
A7
E5
C8
A6
C6
B6
A5
B5
C5
D4
E7
D3
A4
B4
A3
C4
Signal Name
cpu_data[6]
cpu_data[7]
gndio
vcc3io
cpu_data[8]
cpu_data[9]
cpu_data[10]
cpu_data[11]
cpu_data[12]
vcc3io
gndio
gndk
vcck
cpu_data[13]
cpu_data[14]
cpu_data[15]
cpu_cs_n
Type
bidir
bidir
ground
power
bidir
bidir
bidir
bidir
bidir
power
ground
ground
power
bidir
bidir
bidir
input
B3
cpu_rd_n
input
A2
cpu_wr_n
input
April 10, 2013
BGA Pin Descriptions
cpu host interface, data bit 6
cpu host interface, data bit 7
i/o ground
3.3 V i/o supply voltage
cpu host interface, data bit 8
cpu host interface, data bit 0
cpu host interface, data bit 10
cpu host interface, data bit 11
cpu host interface, data bit 12
3.3 V i/o supply voltage
i/o ground
digital core ground
1.8 V digital core supply voltage
cpu host interface, data bit 13
cpu host interface, data bit 14
cpu host interface, data bit 15
cpu host interface, chip select, active low (internal pullup)
cpu host interface, read enable, active low (internal
pull-up)
cpu host interface, write enable, active low (internal
pull-up)
35
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
4.3
April 10, 2013
BGA Package Physical Dimensions
Figure 9 BGA Package Physical Dimensions
36
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
5 Electrical Characteristics
Tables 3 through 7 show the absolute maximum ratings, ESD and latch-up characteristics,
recommended operating conditions, DC Characteristics of I/O cells and power consumption.
Table 3 Absolute Maximum Ratings
Symbol
vcck
vcc18a_pll
vcc3io
vcc3o
TSTG
TJ
Parameter Name
Conditions
digital core supply voltage
pll analog supply voltage
digital i/o supply voltage
digital i/o supply voltage
Storage Temperature
Operating Junction Temperature
Min
-0.5
-0.5
-0.5
-0.5
-65
-40
Typ
-
Max
2.5
2.5
4.6
4.6
150
125
Units
V
V
V
V
o
C
o
C
Min
2000
200
Typ
Max
50
-50
Units
V
V
A
A
Max
1.98
1.98
3.6
3.6
85
-
Units
V
V
V
V
o
C
MHz
Table 4 ESD and Latch-Up Characteristics
Symbol
VHBM
VMM
ILATP
ILATN
Parameter Name
Human Body Model
Machine Model
Positive Latch-Up
Negative Latch-Up
Conditions
Table 5 Recommended Operating Conditions
Symbol
vcck
vcc18a_pll
vcc3io
vcc3o
TA
sys_clk
Parameter Name
digital core supply voltage
pll analog supply voltage
digital i/o supply voltage
digital i/o supply voltage
Ambient Temperature
system clock
Conditions
Min
1.62
1.62
3.0
3.0
-40
-
Typ
1.8
1.8
3.3
3.3
25
Table 6 DC Characteristics of I/O Cells
Symbol
VIH
VIL
VOH
VOL
RPU
RPD
CIN
Parameter Name
input high voltage
input low voltage
output high voltage
output low voltage
Input pull-up resistance
Input pull-down resistance
Input Capacitance
Conditions
IOH = -12 mA
IOL = 12 mA
37
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
Min
2.0
2.4
40
40
Typ
75
75
2.4
Max
0.8
0.4
190
190
Units
V
V
V
V
k
k
pF
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
Table 7 Power Consumption (Nominal)
I/O Voltage 3.3VDC
Core Voltage 1.8VDC
PLL Voltage 1.8VDC
Total
Current
Power
Current
Power
Current
Power
Power
5.27mA
17.39mW
60.0mA
108.0mW
.663mA
1.19mW
126.6mW
5.1
Thermal Characteristics
The thermal resistance characteristics for the LQFP and the BGA packages are provided in Table
8. All data is simulated based on the 2S2P board type. The board type is defined by JEDEC
standard JESD51-7 for the PQFP package, and by JESD51-9 for the BGA package.
Table 8 Thermal Resistance Characteristics
Name
Description
Airflow (m/S)
BGA
LQFP
θJC (°C/W)
Junction to
Case
0
8.03
17.5
θJA (°C/W)
Junction to
Ambient
0
34.09
52.0
5.2
PLL Supply
The PLL for the fido2100 has dedicated supply and ground pins. For best performance of the
PLL it is desirable to provide a quiet or separate 1.8 V supply. Decoupling capacitors of 0.1 uF
and 10 uF should be placed on the board closely to the vdd18a_pll and gnda_pll pins. If the
digital supply is to be used, it is best to also place a series ferrite bead before the decoupling
capacitors and add additional decoupling capacitance of 0.1nF and 10nF.
5.3
System Clock Input
The system clock input (sys_clk) requires a rail-to-rail clock input at 25 MHz. This 25 MHz
clock input is then used by the PLL the create the necessary internal clocks for the fido2100.
38
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
5.4
April 10, 2013
RESET: Power-On-Reset, Hardware Reset and Software Reset
5.4.1 Power-On-Reset
The fido2100 has an internal power-on-reset (POR) circuit which will provide a reset of the PLL
and the rst bit of the Switch Control Register when vcck power is applied. The POR circuit will
keep the PLL and rst bit in reset until the vcck power has exceeded a 1.2 V threshold. Once the
vcck voltage has exceeded the POR threshold the PLL will then need a minimum time of 60 ns to
lock and provide a stable clock source.
5.4.2 Hardware Reset
There is also a reset input (reset_n) provided for a hardware reset of the fido2100. When reset_n
is asserted low the POR circuit will reset the PLL and the rst bit of the Switch Control Register.
The reset_n input must be asserted low for a minimum of 20 ns in order to assure a reset has
occurred. On a reset, once the reset_n input has been de-asserted high, the PLL will then need a
minimum time of 60 ns to lock and provide a stable clock source. The reset_n input has an
internal pull-up which is intended to prevent a reset if the input is un-driven.
5.4.3 Software Reset
Software reset of the fido2100 is accomplished by writing a '1' to the rst bit of the Switch
Control Register. The rst bit is self-clearing on the next clock. When this bit is set, the control
and status registers return to their default conditions.
5.5
Test Input
The test input (test) should be tied low externally for normal operation. There are no user
selectable tests. The test input has an internal pull-down which is intended to prevent a entering
test mode if the input is un-driven.
39
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
6 Host Bus Interface
The Host Bus Interface is used to read and/or write the various configuration and data registers
within the fido2100. The Host Bus Interface consists of the following inputs, an 8-bit address bus
(cpu_adrs[8:1]), a chip select (cpu_cs_n), a read select (cpu_rd_n) and a write select (cpu_wr_n),
along with a 16-bit bidirectional data bus (cpu_data[15:0]).
6.1
READ, Host Bus Interface
A READ is accomplished by selecting a register address using input cpu_adrs[8:1], then
asserting both cpu_cs_n and cpu_rd_n inputs for a sufficient time. The contents of the register
READ will be output on cpu_data[15:0]. The input cpu_wr_n must not be asserted during a
READ operation. A typical READ operation, with necessary timing, can be seen below in Figure
10. During the READ operation the timing between cpu_cs_n and cpu_rd_n is not critical,
however the actual READ cycle begins when both signals are asserted low with the last asserted
signal determining the timing. The READ cycle will end when either cpu_cs_n or cpu_rd_n are
de-asserted high. In the timing diagram of Figure 10, timing is shown only from cpu_rd_n for
simplicity.
Figure 10 Host Interface, READ Timing
Table 9 Host Interface, READ Timing
Description
Symbol
min
cpu_adrs SETUP time
tadsu
0
ns
cpu_adrs HOLD time
tadhd
60
ns
cpu_data VALID time
tdatval
60
ns
cpu_data HOLD time
tdathd
cpu_rd_n DEAD time
trddt
40
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
max
0
40
[email protected]
1-505-883-5263
1-888-824-4184
unit
ns
ns
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
6.2
April 10, 2013
WRITE, Host Bus Interface
A WRITE is accomplished by selecting a register address using input cpu_adrs[8:1], placing
data on cpu_data[15:0], and then asserting both cpu_cs_n and cpu_wr_n inputs for a sufficient
time. The data on the cpu_data[15:0] bus will then be written to the selected register. The input
cpu_rd_n must not be asserted during a WRITE operation. A typical WRITE operation, with
necessary timing, can be seen below in Figure 11. During the WRITE operation the timing
between cpu_cs_n and cpu_wr_n is not critical, however the actual WRITE cycle begins when
both signals are asserted low with the last asserted signal determining the timing. The WRITE
cycle will end when either cpu_cs_n or cpu_wr_n are de-asserted high. In the timing diagram of
Figure 11, timing is shown only from cpu_wr_n for simplicity.
Figure 11 Host Interface, WRITE Timing
Table 10 Host Interface, WRITE Timing
Description
Symbol
min
cpu_adrs SETUP time
tadsu
0
ns
cpu_adrs HOLD time
tadhd
0
ns
cpu_data SETUP time
tdtsu
0
ns
cpu_data HOLD time
tdthd
0
ns
cpu_wr_n WRITE time
twr
50
ns
cpu_wr_n DEAD time
twrdt
40
ns
41
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
max
[email protected]
1-505-883-5263
1-888-824-4184
unit
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
7 External MII Interface
The two external ports, port 1 and port 2, of the 3-Port Industrial Ethernet Switch are connected
to their respective physical layer transceivers (PHY) through an IEEE 802.3 media independent
interface (MII). The MII interface is comprised of 16 pins: transmit clock (px_txc), transmit
enable (px_txen), transmit error (px_txer), transmit data (px_txd[3:0]), receive clock (px_rxc),
receive data valid (px_rxdv), receive data error (px_rxer), receive data (px_rxd[3:0]), collision
(px_col) and carrier sense (px_crs).
7.1
RECEIVE DATA, External MII Interface
An Ethernet packet received by the PHY will be transmitted to its respective port via an MII
interface. The PHY will transmit this data using the MII inputs: px_rxc, px_rxdv, px_rxer and
px_rxd[3:0]. Timing for the RECEIVE DATA is shown below in Figure 12.
Figure 12 External MII Interface, RECEIVE DATA
Table 11 RECEIVE DATA, External MII Interface
Description
Symbol
min
Receive Data SETUP time
trxdsu
10
ns
Receive Data HOLD time
trxdhd
10
ns
Receive Data Valid SETUP time
trxdvsu
10
ns
Receive Data Valid HOLD time
trxdvhd
10
ns
Receive Data Error SETUP time
trxersu
10
ns
Receive Data Error HOLD time
trxerhd
10
ns
42
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
max
[email protected]
1-505-883-5263
1-888-824-4184
unit
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
7.2
April 10, 2013
TRANSMIT DATA, External MII Interface
An Ethernet packet to be transmitted will be sent to its respective PHY via an MII interface. The
PHY will transmit this data using the MII inputs: px_txc, px_txen, px_txer and px_txd[3:0].
Timing for the TRANSMIT DATA is shown below in Figure 13.
Figure 13 External MII Interface, TRANSMIT DATA
Table 12 TRANSMIT DATA, External MII Interface
Description
Symbol
min
max
Transmit Data VALID time
ttxdval
15
ns
Transmit Data HOLD time
ttxdhd
0
ns
Transmit Data Enable VALID time
ttxenval
15
ns
Transmit Data Valid HOLD time
ttcenhd
0
ns
Transmit Data Error VALID time
ttxerval
15
ns
Transmit Data Error HOLD time
ttxerhd
0
ns
8 Internal MII Interface
The single internal port, port CPU, of the 3-Port Industrial Ethernet Switch acts as a physical
layer transceivers (PHY) media independent interface (MII). This MII interface is comprised of
16 pins: transmit clock (cpu_txc), transmit enable (cpu_txen), transmit error (cpu_txer), transmit
data (cpu_txd[3:0]), receive clock (cpu_rxc), receive data valid (cpu_rxdv), receive data error
(cpu_rxer), receive data (cpu_rxd[3:0]), collision (cpu_col) and carrier sense (cpu_crs).
However, as the Internal MII Interface always runs at 100MB and Full-Duplex, the output
cpu_col is always low and the output cpu_crs is the same as cpu_rxdv.
43
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
unit
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
8.1
April 10, 2013
RECEIVE DATA, Internal MII Interface
An Ethernet packet received by the PHY will be transmitted to its respective port via an MII
interface. The PHY will transmit this data using the MII inputs: px_rxc, px_rxdv, px_rxer and
px_rxd[3:0]. Timing for the RECEIVE DATA is shown below in Figure 14.
Figure 14 Internal MII Interface, RECEIVE DATA
Table 13 RECEIVE DATA, External MII Interface
Description
Symbol
min
Receive Data SETUP time
ttxdsu
10
ns
Receive Data HOLD time
ttxdhd
10
ns
Receive Data Enable SETUP time
ttxensu
10
ns
Receive Data Enable HOLD time
ttxenhd
10
ns
Receive Data Error SETUP time
ttxersu
10
ns
Receive Data Error HOLD time
ttxerhd
10
ns
44
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
max
[email protected]
1-505-883-5263
1-888-824-4184
unit
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
8.2
April 10, 2013
TRANSMIT DATA, Internal MII Interface
An Ethernet packet to be transmitted will be sent to its respective PHY via an MII interface. The
PHY will transmit this data using the MII inputs: px_txc, px_txen, px_txer and px_txd[3:0].
Timing for the TRANSMIT DATA is shown below in Figure 15.
Figure 15 Internal MII Interface, TRANSMIT DATA
Table 14 TRANSMIT DATA, External MII Interface
Description
Symbol
min
Transmit Data VALID time
trxdval
5
ns
Transmit Data HOLD time
trxdhd
0
ns
Transmit Data Valid VALID time
trxdvval
5
ns
Transmit Data Valid HOLD time
trxdvhd
0
ns
Transmit Data Error VALID time
trxerval
5
ns
Transmit Data Error HOLD time
trxerhd
0
ns
45
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
max
[email protected]
1-505-883-5263
1-888-824-4184
unit
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
9 Control and Status Registers
Table 13 below contains a listing of all Control & Status Registers accessible from the Host Bus
Interface. The table includes the address, register name, a register mnemonic and the read/write
status of the register. A detailed explanation of the registers is also included in this section
following the table.
9.1
Register Map
Table 15 Register Map
Address
Offset
Function
Mnemonic
R/W
0x00
Time Sync Control
TS_Control
R/W
0x02
Time Sync IRQ Event
TS_Event
R/W
0x04
Addend_Low
Addend_Lo
R/W
0x06
Addend_High
Addend_Hi
R/W
0x08
Accumulator_Low
Accum_Lo
R/W
0x0A
Accumulator_High
Accum_Hi
R/W
0x0C
SystemTime_Low_Low
SysTime_Lo_Lo
R/W
0x0E
SystemTime_Low_High
SysTime_Lo_Hi
R/W
0x10
SystemTime_High_Low
SysTime_Hi_Lo
R/W
0x12
SystemTime_High_High
SysTime_Hi_Hi
R/W
0x14
TargetTime1_Low_Low
TgtTim1_Lo_Lo
R/W
0x16
TargetTime1_Low_High
TgtTim1_Lo_Hi
R/W
0x18
TargetTime1_High_Low
TgtTim1_Hi_Lo
R/W
0x1A
TargetTime1_High-High
TgtTim1_Hi_Hi
R/W
0x1C
TargetTime2_Low_Low
TgtTim2_Lo_Lo
R/W
0x1E
TargetTime2_Low_High
TgtTim2_Lo_Hi
R/W
0x20
TargetTime2_High_Low
TgtTim2_Hi_Lo
R/W
0x22
TargetTime2_High_High
TgtTim2_Hi_Hi
R/W
0x24
Event1Snap_Low_Low
Evnt1_Lo_Lo
(cpu_adrs[8:0])
46
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
R
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Address
Offset
April 10, 2013
Function
Mnemonic
R/W
0x26
Event1Snap_Low_High
Evnt1_Lo_Hi
R
0x28
Event1Snap_High_Low
Evnt1_Hi_Lo
R
0x2A
Event1Snap_High_High
Evnt1_Hi_Hi
R
0x2C
Event2Snap_Low_Low
Evnt2_Lo_Lo
R
0x2E
Event2Snap_Low_High
Evnt2_Lo_Hi
R
0x30
Event2Snap_High_Low
Evnt2_Hi_Lo
R
0x32
Event2Snap_High_High
Evnt2_Hi_Hi
R
0x34
Xmit_SnapShot_Low_Low
TxTS_Lo_Lo
R
0x36
Xmit_SnapShot_Low_High
TxTS_Lo_Hi
R
0x38
Xmit_SnapShot_High_Low
TxTS_Hi_Lo
R
0x3A
Xmit_SnapShot_High_High
TxTS_Hi_Hi
R
0x3C
Recv_Snapshot_Low_Low
RxTS_Lo_Lo
R
0x3E
Recv_Snapshot_Low_High
RxTS_Lo_Hi
R
0x40
Recv_Snapshot_High_Low
RxTS_Hi_Lo
R
0x42
Recv_Snapshot_High_High
RxTS_Hi_Hi
R
0x44
Recv_SourceID_Low_Low
RxID_Lo_Lo
R
0x46
Recv_SourceID_Low_High
RxID_Lo_Hi
R
0x48
Recv_SourceID_High_Low
RxID_Hi_Lo
R
0x4A
Recv_SourceID_High_High
RxID_Hi_Hi
R
0x4C
Recv_SequenceID
RxSeqID
R
0x4E
PTP Sub-domain
Subdomain
R/W
0x50
Switch Control
SW_Control
R/W
0x52
Switch IRQ Event
SW_Event
R/W
0x54
Switch IRQ Mask
SW_Mask
R/W
0x56
Port 1 Seed
Prt1Seed
R/W
0x58
Port 2 Seed
Prt2Seed
R/W
0x5A
MACAddress_Low_Low
MAC_Lo_Lo
R/W
(cpu_adrs[8:0])
47
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Address
Offset
April 10, 2013
Function
Mnemonic
R/W
0x5C
MACAddress_Low_High
MAC_Lo_Hi
R/W
0x5E
MACAddress_High_Low
MAC_Hi_Lo
R/W
0x60
Multicast_Hash_Filter_Index
MCHFI
R/W
0x62
Multicast_Hash_Filter_Value
MCHFV
R/W
0x64
Free_Running_Timer_Low
FreeTmr_Lo
R
0x66
Free_Running_Timer_High
FreeTmr_Hi
R
0x68
PIT_Timeout_Low
PITTmo_Lo
R
0x6A
PIT_Timeout_High
PITTmo_Hi
R
0x6C
Redundancy Control
Rdndnc_Control
0x6E
Ring Beacon State
Rng_BcnState
0x70
Beacon_Timeout_Low
BcnTmo_Lo
R/W
0x72
Beacon_Timeout_High
BcnTmo_Hi
R/W
0x74
Port1_Recv_Beacon_TS_Low
P1BcnTS_Lo
R
0x76
Port1_Recv_Beacon_TS_High
P1BcnTS_Hi
R
0x78
Port2_Recv_Beacon_TS_Low
P2BcnTS_Lo
R
0x7A
Port2_Recv_Beacon_TS_High
P2BcnTS_Hi
R
0x7C
Port1_Neighbor_Check_SrcId_Low_Low
P1NChkSId_Lo_Lo
R
0x7E
Port1_Neighbor_Check_SrcId_Low_High
P1NChkSId_Lo_Hi
R
0x80
Port1_Neighbor_Check_SrcId_High_Low
P1NChkSId_Hi_Lo
R
0x82
Port2_Neighbor_Check_SrcId_Low_Low
P2NChkSId_Lo_Lo
R
0x84
Port2_Neighbor_Check_SrcId_Low_High
P2NChkSId_Lo_Hi
R
0x86
Port2_Neighbor_Check_SrcId_High_Low
P2NChkSId_Hi_Lo
R
0x88
Port1_Neighbor_Status_SrcId_Low_Low
P1NStsSId_Lo_Lo
R
0x8A
Port1_Neighbor_Status_SrcId_Low_High
P1NStsSId_Lo_Hi
R
0x8C
Port1_Neighbor_Status_SrcId_High_Low
P1NStsSId_Hi_Lo
R
0x8E
Port2_Neighbor_Status_SrcId_Low_Low
P2NStsSId_Lo_Lo
R
0x90
Port2_Neighbor_Status_SrcId_Low_High
P2NStsSId_Lo_Hi
R
(cpu_adrs[8:0])
48
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
R/W
R
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Address
Offset
April 10, 2013
Function
Mnemonic
R/W
0x92
Port2_Neighbor_Status_SrcId_High_Low
P2NStsSId_Hi_Lo
0x94
Ring_Supervisor_MacId_Low_Low
RngSprvsrId_Lo_Lo
R/W
0x96
Ring_Supervisor_MacId_Low_High
RngSprvsrId_Lo_Hi
R/W
0x98
Ring_Supervisor_MacId_High_Low
RngSprvsrId_Hi_Lo
R/W
0x9A
Reserved
0x9C
Port1_Recv_Group_Frame_Count
P1RxGrpFrmCnt
R
0x9E
Port2_Recv_Group_Frame_Count
P2RxGrpFrmCnt
R
0xA0
Port1_Recv_Unicast_Frame_Count
P1RxUniFrmCnt
R
0xA2
Port2_Recv_Unicast_Frame_Count
P2RxUniFrmCnt
R
0xA4
Port1_Recv_Byte_Count_Low
P1RxBytCnt_Lo
R
0xA6
Port1_Recv_Byte_Count_High
P1RxBytCnt_Hi
R
0xA8
Port2_Recv_Byte_Count_Low
P2RxBytCnt_Lo
R
0xAA
Port2_Recv_Byte_Count_High
P2RxBytCnt_Hi
R
0xAC
Port1_Recv_Large_Error_Frame_Count
P1RxLrgFrmCnt
R
0xAE
Port2_Recv_Large_Error_Frame_Count
P2RxLrgFrmCnt
R
0xB0
Port1_Recv_Align_Error_Frame_Count
P1RxAlnFrmCnt
R
0xB2
Port2_Recv_Align_Error_Frame_Count
P2RxAlnFrmCnt
R
0xB4
Port1_Recv_FCS_Error_Frame_Count
P1RxFcsFrmCnt
R
0xB6
Port2_Recv_FCS_Error_Frame_Count
P2RxFcsFrmCnt
R
0xB8
Port1_Recv_Error_Frame_Count
P1RxErrFrmCnt
R
0xBA
Port2_Recv_Error_Frame_Count
P2RxErrFrmCnt
R
0xBC
Port1_Xmit_Group_Frame_Count
P1TxGrpFrmCnt
R
0xBE
Port2_Xmit_Group_Frame_Count
P2TxGrpFrmCnt
R
0xC0
Port1_Xmit_Unicast_Frame_Count
P1TxUniFrmCnt
R
0xC2
Port2_Xmit_Unicast_Frame_Count
P2TxUniFrmCnt
R
0xC4
Port1_Xmit_Byte_Count_Low
P1TxBytCnt_Lo
R
0xC6
Port1_Xmit_Byte_Count_High
P1TxBytCnt_Hi
R
(cpu_adrs[8:0])
R
49
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
R
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Address
Offset
April 10, 2013
Function
Mnemonic
R/W
0xC8
Port2_Xmit_Byte_Count_Low
P2TxBytCnt_Lo
R
0xCA
Port2_Xmit_Byte_Count_High
P2TxBytCnt_Hi
R
0xCC
Port1_Xmit_Single_Collision_Frame_Count
P1TxSClFrmCnt
R
0xCE
Port2_Xmit_Single_Collision_Frame_Count
P2TxSClFrmCnt
R
0xD0
Port1_Xmit_Multi_Collision_Frame_Count
P1TxMClFrmCnt
R
0xD2
Port2_Xmit_Multi_Collision_Frame_Count
P2TxMClFrmCnt
R
0xD4
Port1_Xmit_Excess_Collision_Frame_Count
P1TxXClFrmCnt
R
0xD6
Port2_Xmit_Excess_Collision_Frame_Count
P2TxXClFrmCnt
R
0xD8
Port1_Xmit_Error_Frame_Count
P1TxErrFrmCnt
R
0xDA
Port2_Xmit_Error_Frame_Count
P2TxErrFrmCnt
R
0xDC
Beacon_Generation_Control
BcnGenCntrl
R/W
0xDE
Beacon_Interval_Low
BcnIntrvl_Lo
R/W
0xE0
Beacon_Interval_High
BcnIntrvl_Hi
R/W
0xE2
Beacon_Data_Index
BcnDataIdx
R/W
0xE4
Beacon_Data_Value
BcnDataVal
R/W
0xE6
Embedded_Switch_Version
EmbSwtchVer
(cpu_adrs[8:0])
50
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
R
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
9.2 Detailed Register Explanations
9.2.1 Time Sync Control Register
Mnemonic
type offset bits
TS_Control
15
14
13
12
11
10
0
0
0
0
0
0
R/W 0x00
Power-up Defaults
9
8
rxm
txm
0
0
7
6
5
mm ppse tte2
0
0
0
4
3
2
1
tte1 evm2 evm1 ttm2 ttm1
0
0
0
0
ttm1-2
Target Time Interrupt Mask 1-2. The Target Time interrupt mask 1-2
controls whether the corresponding Target Time interrupt is passed to the Host
processor. When any of these bits are set, the corresponding interrupt to the
Host is enabled. When any of these bits are cleared, the corresponding Target
Time interrupt to the Host is disabled.
evm1
Event 1 Interrupt Mask. The interrupt for the Host is always disabled,
regardless of the state of this bit.
evm2
Event 2 Interrupt Mask. The interrupt for the Host is always disabled,
regardless of the state of this bit.
tte1-2
Target Time Interrupt Enable 1-2. The Target Time interrupt enable 1-2
controls whether the corresponding Target Time interrupt is enabled. When
any of these bits are set, the corresponding Target Time Register is compared
with System Time Register. When they match, the corresponding ttp1-2 bit in
TS_Event register is set and the corresponding tte1-2 bit is reset. If the
corresponding ttm1-2 bit is also set then an interrupt is delivered to the Host.
To prevent spurious interrupts firmware should write to Target Time Registers
1-2, only when corresponding tte1-2 is not set.
ppse
Pulse Per Second Enable. When this bit is set, the state of ttp2 bit in the
TS_Event register is reflected on output pin pps_sig.
mm
Master Mode. When this bit is set, the Time Sync logic implementing IEEE
1588 ordinary clock hardware assist on the local port connected to the host
CPU MII interface, will operate in master mode. When this bit is reset the
same logic will operate in slave mode.
txm
Transmit Snapshot Interrupt Mask. The transmit snapshot interrupt mask
controls whether the transmit snapshot txs bit in the TS_Event register, should
interrupt the Host processor. When this bit is set, the interrupt to the Host is
enabled. When cleared, the interrupt to the Host is disabled.
51
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
[email protected]
1-505-883-5263
1-888-824-4184
0
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
rxm
April 10, 2013
Receive Snapshot Interrupt Mask. The receive snapshot interrupt mask
controls whether the receive snapshot rxs bit in the TS_Event register, should
interrupt the Host processor. When this bit is set, the interrupt to the Host is
enabled. When cleared, the interrupt to the Host is disabled.
9.2.2 Time Sync Interrupt Event Register
Mnemonic
type offset bits
TS_Event
R/W 0x02
Power-up Defaults
15
0
14
0
13
0
12
0
11
0
10
0
9
0
8
0
7
0
6
0
5
4
rxs
txs
0
0
3
2
1
evs2 evs1 ttp2
0
0
0
All interrupt requests from Time Sync Event register will be delivered to the host CPU
through the ts_event_irq_n signal.
ttp1-2
Target Time Interrupt Pending 1-2. The Target Time interrupt pending 1-2
indicates if the corresponding Target Time register matched the System Time,
as explained under tte1-2 in the Time Sync Control register. If corresponding
ttm1-2 bit in the Time Sync Control register is also set, an interrupt will be
delivered to the Host. ttp1-2 can be reset by writing a ‘1’ to it.
evs1
Event 1 Snapshot. A rising edge on the input pin event_1_sig causes a
snapshot of the System Time to be saved in the External Event 1 Snapshot
register, and the evs1 bit to be set. After an event_1_sig, polling of this
register should take place in order to determine that a snapshot has taken place
when evs1 is set. Now the External Event 1 Snapshot register can be read. A
subsequent rising edge will not cause the snapshot to be updated while the
evs1 bit is set. This bit can be reset by writing a ‘1’ to it.
evs2
Event 2 Snapshot. A rising edge on the input pin event_2_sig causes a
snapshot of the System Time to be saved in the External Event 2 Snapshot
register, and the evs2 bit to be set. After an event_2_sig, polling of this
register should take place in order to determine that a snapshot has taken place
when evs2 is set. Now the External Event 2 Snapshot register can be read. A
subsequent rising edge will not cause the snapshot to be updated while the
evs2 bit is set. This bit can be reset by writing a ‘1’ to it.
txs
Transmit Snapshot. A Sync frame in master mode or Delay_Req frame in
slave mode will cause a snapshot of the System time to be saved in the
Transmit Snapshot register and the txs bit to be set. Subsequent
Sync/Delay_Req frames will not cause the snapshot to be updated while the
52
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
0
ttp1
0
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
txs bit is set. If this bit is set and the txm bit in TS_Control register is also set,
an interrupt will be delivered to the Host. This bit can be reset by writing a ‘1’
to it.
rxs
Receive Snapshot. A Sync frame in slave mode or a Delay_Req frame in
master mode will cause a snapshot of the System time to be saved in the
Receive Snapshot register, the source ID/sequence ID of incoming frame to be
saved in the Receive Source ID/Sequence ID registers and the rxs bit to be set.
Up to 16 snapshots will be stored in the FIFO if firmware is slow to process
them. If the FIFO is full, subsequent Sync/Delay_Req frames will not cause a
snapshot/source ID/sequence ID to be stored. If this bit is set and the rxm bit
in TS_Control register is also set, an interrupt will be delivered to the Host.
This bit can be reset by writing a ‘1’ to it. If the bit doesn’t reset, it indicates
additional snapshots are present. Firmware should repeatedly read and store all
entries from the FIFO until this bit is reset.
9.2.3 Addend Register
Mnemonic
type offset bits
Addend_Lo
R/W 0x04
Power-up Defaults
Mnemonic
type offset bits
Addend_Hi
R/W 0x06
Power-up Defaults
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Addend[15:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
Addend[31:16]
0
0
0
0
0
0
0
0
0
The Addend register consists of two 16-bit registers. The Addend register contains the
frequency scaling value used by a firmware algorithm to achieve time synchronization in
the module. The value in this register is added to the value in the Accumulator. When the
Accumulator rolls over, an overflow pulse is asserted and increments system time.
Because the Addend register is cleared at reset, it must be written with a non-zero value
to allow system time to increment. Reads of the two 16-bit registers can be performed in
any order. When performing writes, Addend_Lo should be written first. When
Addend_Hi is written later, an internal addend register will be updated with the full 32bit value.
53
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
9.2.4 Accumulator Register
Mnemonic
type offset bits
Accum_Lo
15
14
13
12
11
10
9
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
0
0
0
0
0
0
0
R/W 0x08
Power-up Defaults
Mnemonic
type offset bits
Accum_Hi
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
6
5
4
3
2
1
0
0
0
0
0
0
0
Accumulator[15:0]
R/W 0x0A
Power-up Defaults
8
Accumulator[31:16]
0
0
0
The Accumulator register consists of two 16-bit registers. The Accumulator register
serves as a precision frequency divider in the time synchronization logic. Firmware
calculates a frequency scaling value to be written to the Addend register. The data in the
Accumulator register is added to the value in the Addend register once every period of
the system clock. When the Accumulator rolls over, an overflow pulse is asserted which
increments the value in the system timer. This register is not read or written to in normal
operation. When performing reads, Accum_Lo should be read first, which will cause the
higher 16 bits of the internal accumulator register to be latched and when Accum_Hi is
read later, the latched value will be returned. When performing writes, Accum_Lo should
be written first and when Accum _Hi is written later, the internal accumulator register
will be updated with the full 32-bit value.
9.2.5 System Time Register
Mnemonic
type offset bits
SysTime_Lo_Lo
type offset bits
SysTime_Lo_Hi
type offset bits
SysTime_Hi_Lo
type offset bits
SysTime_Hi_Hi
12
11
10
9
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
Systime[31:16]
Systime[47:32]
R/W 0x12
Power-up Defaults
8
Systime[15:0]
R/W 0x10
Power-up Defaults
Mnemonic
13
R/W 0x0E
Power-up Defaults
Mnemonic
14
R/W 0x0C
Power-up Defaults
Mnemonic
15
Systime[63:48]
54
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
The System Time register consists of four 16-bit registers. The system timer is a loadable
up-counter and reflects the local time in the module. The system timer is incremented
when the Accumulator register rolls over. When performing reads, SysTime_Lo_Lo
should be read first, which will cause the higher 48-bits of the internal system time
register to be latched. When other SysTime_XX_XX registers are read later, the latched
value will be returned. When performing writes, the lower three SysTime_XX_XX
should be written first, and when SysTime_Hi_Hi is written later, the internal system
time register will be updated with the full 64 bit value.
9.2.6 Target Time1 Register
Mnemonic
type offset bits
TgtTim1_Lo_Lo
R/W 0x14
Power-up Defaults
Mnemonic
type offset bits
TgtTim1_Lo_Hi
type offset bits
TgtTim1_Hi_Lo
type offset bits
TgtTim1_Hi_Hi
13
12
11
10
9
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Target1[31:16]
Target1[47:32]
R/W 0x1A
Power-up Defaults
8
Target1[15:0]
R/W 0x18
Power-up Defaults
Mnemonic
14
R/W 0x16
Power-up Defaults
Mnemonic
15
Target1[63:48]
0
0
The Target Time1 register consists of four 16-bit registers. When the system time is equal
to the target time value, the ttp1 bit in the Time Sync Event register is set and an interrupt
is generated to the Host if the ttm1 bit in the Time Sync Control register is also set. Reads
and writes of four 16-bit registers can be performed in any order. In order to prevent
spurious interrupts during writes, the tte1 bit should be ‘0’ in the Time Sync Control
register when writing to any of the four 16-bit registers.
55
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
9.2.7 Target Time2 Register
Mnemonic
type offset bits
TgtTim2_Lo_Lo
type offset bits
TgtTim2_Lo_Hi
type offset bits
TgtTim2_Hi_Lo
type offset bits
TgtTim2_Hi_Hi
12
11
10
9
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
Target2[31:16]
Target2[47:32]
R/W 0x22
Power-up Defaults
8
Target2[15:0]
R/W 0x20
Power-up Defaults
Mnemonic
13
R/W 0x1E
Power-up Defaults
Mnemonic
14
R/W 0x1C
Power-up Defaults
Mnemonic
15
Target2[63:48]
0
0
The Target Time2 register consists of four 16-bit registers. When the system time is equal
to the target time value, the ttp2 bit in the Time Sync Event register is set and an interrupt
is generated to the Host if the ttm2 bit in the Time Sync Control register is also set. Reads
and writes of four 16-bit registers can be performed in any order. In order to prevent
spurious interrupts during writes, the tte2 bit should be ‘0’ in the Time Sync Control
register when writing to any of the four 16-bit registers. As explained under the ppse bit
in Time Sync Control register, the Target Time2 register can also be used to generate a
pulse per second output on the pps_sig pin.
9.2.8 External Event 1 Snapshot Register
Mnemonic
Evnt1_Lo_Lo
type offset bits
R
Power-up Defaults
Mnemonic
Evnt1_Lo_Hi
type offset bits
R
15
14
13
12
11
10
9
0x24
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0x26
Power-up Defaults
8
Evnt1Snap[15:0]
Evnt1Snap[31:16]
0
0
0
0
0
56
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Mnemonic
Evnt1_Hi_Lo
type offset bits
R
Mnemonic
Evnt1_Hi_Hi
type offset bits
R
15
14
13
12
11
10
9
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
0
0
0
0
0
0
0
0x28
Power-up Defaults
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
6
5
4
3
2
1
0
0
0
0
0
0
0
Evnt1Snap[47:32]
0x2A
Power-up Defaults
April 10, 2013
Evnt1Snap[63:48]
0
0
0
The External Event 1 Snapshot register consists of four 16-bit registers. A rising edge on
the input signal event_1_sig , triggers a snapshot of the System Time into Evnt1_XX_XX
registers and the evs1 bit in Time Sync Event register is set. Polling of the Time Sync
Event register for evs1 can be used to determine when this register is ready for a read.
Reads of the four 16-bit registers can be performed in any order. The evs1 bit in the
Time Sync Event register must be reset by writing a ‘1’ to it in order to snapshot the
system time at the next rising edge of event_1_sig .
9.2.9 External Event 2 Snapshot Register
Mnemonic
Evnt2_Lo_Lo
type offset bits
R
Evnt2_Lo_Hi
type offset bits
R
Evnt2_Hi_Lo
type offset bits
R
Evnt2_Hi_Hi
type offset bits
R
12
11
10
9
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Evnt2Snap[31:16]
Evnt2Snap[47:32]
0x32
Power-up Defaults
8
Evnt2Snap[15:0]
0x30
Power-up Defaults
Mnemonic
13
0x2E
Power-up Defaults
Mnemonic
14
0x2C
Power-up Defaults
Mnemonic
15
Evnt2Snap[63:48]
57
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
The External Event 2 Snapshot register consists of four 16-bit registers. A rising edge on
the input signal event_2_sig , triggers a snapshot of the System Time into Evnt2_XX_XX
registers and the evs2 bit in Time Sync Event register is set. Polling of the Time Sync
Event register for evs2 can be used to determine when this register is ready for a read.
Reads of the four 16-bit registers can be performed in any order. The evs2 bit in the
Time Sync Event register must be reset by writing a ‘1’ to it in order to snapshot the
system time at the next rising edge of event_2_sig .
9.2.10 Transmit Snapshot Register
Mnemonic
TxTS_Lo_Lo
type offset bits
R
Power-up Defaults
Mnemonic
TxTS_Lo_Hi
type offset bits
R
TxTS_Hi_Lo
type offset bits
R
TxTS_Hi_Hi
type offset bits
R
13
12
11
10
0
0
0
0
0
0
15
14
13
12
11
10
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
9
8
7
6
5
4
3
2
1
0
TransmitSnap[31:16]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
TransmitSnap[47:32]
0x3A
Power-up Defaults
9
TransmitSnap[15:0]
0x38
Power-up Defaults
Mnemonic
14
0x36
Power-up Defaults
Mnemonic
15
0x34
TransmitSnap[63:48]
0
0
0
0
The Transmit Snapshot register consists of four 16-bit registers. A Sync frame in master
mode or Delay_Req frame in slave mode triggers a snapshot of the System Time into
Xmit_XX_XX registers and the txs bit in Time Sync Event register is set. Reads of the
four 16-bit registers can be performed in any order. The txs bit in the Time Sync Event
register must be reset by writing a ‘1’ to it in order to snapshot system time at the next
Sync or Delay_Req frame.
9.2.11 Receive Snapshot Register
Mnemonic
RxTS_Lo_Lo
type offset bits
R
15
14
13
12
11
10
0x3C
Power-up Defaults
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
ReceiveSnap[15:0]
0
0
0
0
0
58
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Mnemonic
RxTS_Lo_Hi
type offset bits
R
Mnemonic
RxTS_Hi_Lo
type offset bits
R
RxTS_Hi_Hi
type offset bits
R
14
13
12
11
10
9
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
0
0
0
0
0
0
0
7
0
0
15
14
13
12
11
10
9
8
7
0
0
0
0
0
0
0
6
5
4
3
2
1
0
0
0
0
0
0
0
0
6
5
4
3
2
1
0
0
0
0
0
0
0
0
6
5
4
3
2
1
0
0
0
0
0
0
0
ReceiveSnap[47:32]
0x42
Power-up Defaults
8
ReceiveSnap[31:16]
0x40
Power-up Defaults
Mnemonic
15
0x3E
Power-up Defaults
April 10, 2013
ReceiveSnap[63:48]
0
0
0
The Receive Snapshot register consists of four 16-bit registers. A Sync frame in slave
mode or Delay_Req frame in master mode triggers a snapshot of the System Time into
the Recv_XX_XX registers and the rxs bit in Time Sync Event register is set. Reads of
four 16-bit registers can be performed in any order. Up to 16 snapshots will be stored in
the FIFO if firmware is slow to process them. If the FIFO is full, subsequent
Sync/Delay_Req frames will not cause the snapshot/source ID/sequence ID to be stored.
The rxs bit in the Time Sync Event register must be reset by writing a ‘1’ to it after
reading a snapshot. If the bit doesn’t reset, it indicates that additional snapshots are
present. Firmware should repeatedly read and store all entries from the FIFO until this bit
is reset.
9.2.12 Receive Source ID Register
Mnemonic
RxID_Lo_Lo
type offset bits
R
RxID_Lo_Hi
type offset bits
R
RxID_Hi_Lo
type offset bits
R
13
12
11
10
9
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SourceID[31:16]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0x48
Power-up Defaults
8
SourceID[15:0]
0x46
Power-up Defaults
Mnemonic
14
0x44
Power-up Defaults
Mnemonic
15
SourceID[47:32]
0
0
0
0
0
59
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Mnemonic
RxID_Hi_Hi
type offset bits
R
15
14
13
12
11
10
April 10, 2013
9
0x4A
Power-up Defaults
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
SourceID[63:48]
0
0
0
0
0
0
0
0
0
The Receive Source ID register consists of four 16-bit registers. The reception of a Sync
frame in slave mode or Delay_Req frame in master mode triggers the capture of the
source ID field in the received frame into the RxID_XX_XX registers. Reads of the four
16-bit registers can be performed in any order. See the Receive Snapshot register for
additional description.
9.2.13 Receive Sequence ID Register
Mnemonic
RxSeqID
type offset bits
R
15
14
13
12
11
10
0x4C
Power-up Defaults
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
2
1
0
0
0
0
SequenceID[15:0]
0
0
0
0
0
0
0
0
0
0
The reception of a Sync frame in slave mode or Delay_Req frame in master mode
triggers the capture of the sequence ID field in the received frame into the RxSeqID
register. See the Receive Snapshot register for additional description.
9.2.14 PTP Sub-domain Register
Mnemonic
type offset bits
Subdomain
R/W 0x4E
Power-up Defaults
15
14
13
12
11
10
9
8
7
6
5
4
3
Subdomain[7:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
The PTP Sub-domain register is used to specify the sub-domain field of PTP event
frames. Only the PTP event frames matching the value in this register will be time
stamped. By default, this register will be 0, matching only the default sub-domain event
frames.
9.2.15 Switch Control Register
Mnemonic
SW_Control
type offset bits
15
14
13
12
11
R/W 0x50
ulfe
dms
dbs
dfc
dbg
1
1
0
0
0
Power-up Defaults
rst
10
9
8
7
p2ly p1ly p2lo p1lo
0
0
0
0
6
5
4
3
2
1
0
p2s
p1s
p2h
p1h
p2r
p1r
rst
0
0
0
0
1
1
0
Chip Reset. When a ‘1’ is written to this bit, all logic is returned to the same
default state as when a power-on reset occurs. This bit is self-clearing.
60
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
p1r
Port 1 Reset. When this bit is set, port 1 is held in reset and no packets will be
transmitted or received on port 1. This bit must be set for a minimum of 500
nanosecs for a proper reset.
p2r
Port 2 Reset. When this bit is set, port 2 is held in reset and no packets will be
transmitted or received on port 2. This bit must be set for a minimum of 500
nanosecs for a proper reset.
p1h
Port 1 Half Duplex. When this bit is set, port 1 is in half duplex mode. When
this bit is reset, port 1 is in full duplex mode. This bit should be set to the same
duplex mode as negotiated/forced in the PHY. This bit should be changed only
when p1r is set i.e. port 1 is held in reset.
p2h
Port 2 Half Duplex. When this bit is set, port 2 is in half duplex mode. When
this bit is reset, port 2 is in full duplex mode. This bit should be set to the same
duplex mode as negotiated/forced in the PHY. This bit should be changed only
when p2r is set i.e. port 2 is held in reset.
p1s
Port 1 Speed 10Mbps. When this bit is set, the port 1 is operating at 10Mbps
speed. When this bit is reset, port 1 is operating at 100Mbps speed. This bit
should be set to the same speed as negotiated/forced in the PHY. This bit
should be changed only when p1r is set i.e. port 1 is held in reset.
p2s
Port 2 Speed 10Mbps. When this bit is set, the port 2 is operating at 10Mbps
speed. When this bit is reset, port 2 is operating at 100Mbps speed. This bit
should be set to the same speed as negotiated/forced in the PHY. This bit
should be changed only when p2r is set i.e. port 2 is held in reset.
p1lo
Port 1 LED On. When this bit is set, the port 1 LED is turned on. When there
is no link activity on port 1 the LED will be solid indicating the link is up.
When there is link activity on port 1 the LED will blink at a rate of 10Hz.
Firmware can place port 1 in reset and set this bit to test the LED.
p2lo
Port 2 LED On. When this bit is set, the port 2 LED is turned on. When there
is no link activity on port 2, the LED will be solid indicating the link is up.
When there is link activity on port 2 the LED will blink at a rate of 10Hz.
Firmware can place port 2 in reset and set this bit to test the LED.
p1ly
Port 1 LED Yellow. When this bit is set, the port 1 LED will be driven to the
yellow color. If this bit is reset, the port 1 LED will be driven to the green
color. Firmware can place port 1 in reset and set/reset this bit to test
yellow/green color LEDs.
61
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
p2ly
Port 2 LED Yellow. When this bit is set, the port 2 LED will be driven to the
yellow color. If this bit is reset, the port 2 LED will be driven to the green
color. Firmware can place port 2 in reset and set/reset this bit to test
yellow/green color LEDs.
dbg
Internal Port Debug Mode. When this bit is set, the internal port connected to
the host CPU will operate in promiscuous mode and will forward all traffic
received on ports 1 and 2 to host CPU. When the combined traffic received on
ports 1 and 2 exceed the bandwidth capacity of 100Mbps of the internal port,
frames will be dropped on the internal port. Hence this setting must be used
only for debug purposes and not during normal operation.
dfc
Disable Flow Control. When this bit is set, flow control is disabled on all
ports in both full and half duplex modes.
dbs
Disable Broadcast Storm Control. When this bit is set, broadcast storm
control will be disabled.
dms
Disable Multicast Storm Control. When this bit is set multicast storm control
will be disabled.
ulfe
Unicast MAC Address Learning and Filtering Enable. When this bit is set,
dynamic unicast MAC address learning and filtering is enabled. To flush
unicast MAC address learning table reset this bit and then set it again.
9.2.16 Switch IRQ Event Register
Mnemonic
type offset bits
15
14
SW_Event
R/W 0x52
lst2
lst1
0
0
Power-up Defaults
13
0
12
0
11
0
10
9
8
pit
p2l
p1l
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
All interrupt requests from the Switch IRQ Event register will be delivered to the host
CPU through the sw_event_irq_n signal.
lirq1
Port 1 Link Status Change IRQ. When a change of status occurs on the lst1
bit, then the lirq1 will be set. When the l1m bit in the Switch Mask register is
also set, then an interrupt is delivered to the host CPU. This bit can be reset by
writing a ‘1’ to it.
lirq2
Port 2 Link Status Change IRQ. When a change of status occurs on the lst2
bit, then the lirq2 will be set. When the l2m bit in the Switch Mask register is
62
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
bto2 bto1 brx2 brx1 rbs2 rbs1 lirq2 lirq1
[email protected]
1-505-883-5263
1-888-824-4184
0
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
also set, then an interrupt is delivered to the host CPU. This bit can be reset by
writing a ‘1’ to it.
rbs1
Port 1 Ring Beacon State Change IRQ. When a ring beacon is received
through port 1 and a change of State field in the frame is detected when
compared to the previous beacon, this bit is set. When the rbm1 bit in the
Switch Mask register is also set, an interrupt is delivered to the host CPU. This
bit can be reset by writing a ‘1’ to it.
rbs2
Port 2 Ring Beacon State Change IRQ. When a ring beacon is received
through port 2 and a change of State field in frame is detected when compared
to the previous beacon, this bit is set. When the rbm2 bit in the Switch Mask
register is also set, an interrupt is delivered to the host CPU. This bit can be
reset by writing a ‘1’ to it.
brx1
Port 1 Beacon Received IRQ. When a ring beacon is received through port 1,
this bit is set. When the brm1 bit in the Switch Mask register is also set, an
interrupt is delivered to the host CPU. This bit can be reset by writing a ‘1’ to
it.
brx2
Port 2 Beacon Received IRQ. When a ring beacon is received through port 2,
this bit is set. When the brm2 bit in the Switch Mask register is also set, an
interrupt is delivered to the host CPU. This bit can be reset by writing a ‘1’ to
it.
bto1
Port 1 Beacon Timeout IRQ. When a ring beacon is not received through
port 1 within the beacon timeout period, this bit is set. When the btm1 bit in
the Switch Mask register is also set, an interrupt is delivered to the host CPU.
This bit can be reset by writing a ‘1’ to it.
bto2
Port 2 Beacon Timeout IRQ. When a ring beacon is not received through
port 2 within the beacon timeout period, this bit is set. When the btm2 bit in
the Switch Mask register is also set, an interrupt is delivered to the host CPU.
This bit can be reset by writing a ‘1’ to it.
p1l
Port 1 Loop IRQ. When a frame with the same source address field as the
host CPU MAC address is received on port 1, this bit is set. When the p1lm bit
in the Switch Control register is also set, an interrupt is delivered to the host
CPU. This bit indicates a network misconnection resulting in a loop when not
in ring redundancy mode. This should be flagged to the user, indicating a
network fault condition. This bit can be cleared by writing a ‘1’ to it.
63
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
p2l
Port 2 Loop IRQ. When a frame with the same source address field as the
host CPU MAC address is received on port 2, this bit is set. When the p2lm bit
in the Switch Control register is also set, an interrupt is delivered to the host
CPU. This bit indicates a network misconnection resulting in a loop when not
in ring redundancy mode. This should be flagged to the user, indicating a
network fault condition. This bit can be cleared by writing a ‘1’ to it.
pit
Periodic Interval Timer IRQ. When the periodic interval timer expires (i.e.
counts down to zero) this bit is set. When the pitm bit in the Switch Mask
register is also set, an interrupt is delivered to the host CPU. This bit can be
reset by writing a ‘1’ to it.
lst1
Port 1 Link Status. This bit reflects the port 1 link status from the
P1_LNKSTS input signal. A ‘1’ indicates a valid link has been established (i.e.
link pass status) and a ‘0’ indicates link fail status. This is a read only bit,
writes will be ignored.
lst2
Port 2 Link Status. This bit reflects the port 2 link status from the
P2_LNKSTS input signal. A ‘1’ indicates a valid link has been established (i.e.
link pass status) and a ‘0’ indicates link fail status. This is a read only bit,
writes will be ignored.
9.2.17 Switch IRQ Mask Register
Mnemonic
type offset bits
SW_Mask
R/W 0x54
Power-up Defaults
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
pitm p2lm p1lm btm2 btm1 brm2 brm1 rbm2 rbm1 l2m
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
l1m
Port 1 Link Status Change IRQ Mask. When this bit is set and the lirq1 bit
in the Switch Event register is also set, then an interrupt is delivered to the host
CPU.
l2m
Port 2 Link Status Change IRQ Mask. When this bit is set and the lirq2 bit
in the Switch Event register is also set, then an interrupt is delivered to the host
CPU.
rbm1
Port 1 Ring Beacon State Change IRQ Mask. When this bit is set and the
rbs1 bit in the Switch Event register is also set, an interrupt is delivered to the
host CPU.
64
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
0
l1m
0
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
rbm2
Port 2 Ring Beacon State Change IRQ Mask. When this bit is set and the
rbs2 bit in the Switch Event register is also set, an interrupt is delivered to the
host CPU.
brm1
Port 1 Beacon Received IRQ Mask. When this bit is set and the brx1 bit in
the Switch Event register is also set, an interrupt is delivered to the host CPU.
brm2
Port 2 Beacon Received IRQ Mask. When this bit is set and the brx2 bit in
the Switch Event register is also set, an interrupt is delivered to the host CPU.
btm1
Port 1 Beacon Timeout IRQ Mask. When this bit is set and the bto1 bit in
the Switch Event register is also set, an interrupt is delivered to the host CPU.
btm2
Port 2 Beacon Timeout IRQ Mask. When this bit is set and the bto2 bit in
the Switch Event register is also set, an interrupt is delivered to the host CPU.
p1lm
Port 1 Loop IRQ Mask. When this bit is set and the p1l bit in the Switch
Event register is also set, an interrupt is delivered to the host CPU.
p2lm
Port 2 Loop IRQ Mask. When this bit is set and the p2l bit in the Switch
Event register is also set, an interrupt is delivered to the host CPU.
pitm
Periodic Interval Timer IRQ Mask. When this bit is set and the pit bit in the
Switch Event register is also set, an interrupt is delivered to the host CPU.
9.2.18 Port 1 Seed Register
Mnemonic
type offset bits
Prt1Seed
R/W 0x56
Power-up Defaults
p1seed
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
p1seed
0
0
0
0
0
0
0
0
0
0
0
0
Port 1 Seed. When the port 1 is in half duplex mode, this field can be used to
load a 10-bit seed value into the linear feedback shift register that is used for
the truncated binary exponential back off algorithm.
9.2.19 Port 2 Seed Register
Mnemonic
Prt2Seed
type offset bits
15
14
13
12
11
10
9
8
7
6
5
0
0
0
0
0
0
0
0
0
0
0
R/W 0x58
Power-up Defaults
4
3
2
1
0
0
0
0
0
p2seed
65
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
p2seed
April 10, 2013
Port 2 Seed. When the port 2 is in half duplex mode, this field can be used to
load a 10-bit seed value into the linear feedback shift register that is used for
the truncated binary exponential back off algorithm.
9.2.20 Host CPU MAC Address Register
Mnemonic
MAC_Lo_Lo
type offset bits
MAC_Lo_Hi
14
13
12
11
10
9
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
R/W 0x5A
Power-up Defaults
Mnemonic
15
type offset bits
Mnemonic
type offset bits
MAC_Hi_Lo
R/W 0x5E
Power-up Defaults
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
6
5
4
3
2
1
0
0
0
0
0
0
0
0
6
5
4
3
2
1
0
0
0
0
0
0
0
MACAddress[15:0]
R/W 0x5C
Power-up Defaults
8
MACAddress[31:16]
MACAddress[47:32]
0
0
0
0
0
0
0
0
0
0
The Host CPU MAC Address register consists of three 16-bit registers. This register
should be set to the same unicast MAC address as the host CPU MAC address. For
example to load the MAC address 00-11-22-33-44-55, 0x0011 should be written to the
MAC_Hi_Lo, 0x2233 should be written to the MAC_Lo_Hi, and 0x4455 should be
written to the MAC_Lo_Lo. The content of this register is used to perform filtering inside
the switch. Unicast frames cannot be received on the host until this register is set. The
switch performs limited filtering of unicast frames. When a unicast frame is received on
any port with a destination address equal to the host MAC address, then that frame is
delivered to the host and is not forwarded to the other port. If a unicast frame is received
on any port with a destination address not equal to the host MAC address, then it is only
forwarded to the other port, but not to the host. Reads and writes of the three 16-bit
registers can be performed in any order.
66
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
9.2.21 Multicast Hash Filter Index and Value Registers
Mnemonic
type offset bits
MCHFI
R/W 0x60
Power-up Defaults
Mnemonic
MCHFV
type offset bits
15
14
13
12
11
10
9
8
7
6
5
0
0
0
0
0
0
0
0
0
0
0
3
2
1
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
MulticastHashIndex[6:0]
R/W 0x62
Power-up Defaults
4
MulticastHashValue[15:0]
0
0
0
0
The Multicast Hash Filter consists of one hundred and twenty eight (128) 16-bit registers.
These 128 registers comprise a 2048 bin hash filter table, with bit 0 of register 0
corresponding to bin 0, and bit 15 of register 127 corresponding to bin 2047. In order to
access a filter register, the register number should first be written to the Multicast Hash
Filter Index register. The register value can then be read from/written to through the
Multicast Hash Filter Value register. When a multicast frame is received on an external
port, the CRC is computed on the received multicast address, and the bottom 11 bits of
the CRC are used to select the bin in the multicast hash filter table. If the selected bin is
set, then the frame will be delivered to the host CPU. The algorithm used to compute the
CRC is the same as the Ethernet CRC. One version of the CRC code is enclosed for
reference. A table driven version of the Ethernet CRC code can also be used for speed.
For example, to receive multicast address 01-00-5E-00-01-81 (CRC=0xD2E88860),
register 6, bit 0 must be set. Note that the filter table need not be set for receiving
multicast ring frames.
67
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
//--------------------------------------------------------------------const unsigned Poly = 0xedb88320; // bit reverse of 0x04c11db7
//--------------------------------------------------------------------unsigned ComputeCrc32 (unsigned char *buf, int len)
{
unsigned crc = 0xffffffff;
while (--len >= 0)
{
unsigned char data = *buf++;
for (int i = 0; i < 8; i++)
{
if ((crc ^ data) & 1)
{
crc >>= 1;
crc ^= Poly;
}
else crc >>= 1;
data >>= 1;
}
}
return (crc ^ 0xffffffff);
}
//--------------------------------------------------------------------unsigned GetMCHashBin (unsigned char mcadrs[6])
{
unsigned crc = ComputeCrc32 ((unsigned char *)mcadrs, 6);
return (crc & 0x7ff);
}
//---------------------------------------------------------------------
9.2.22 Free Running Timer Register
Mnemonic
FreeTmr_Lo
type offset bits
R
Power-up Defaults
Mnemonic
FreeTmr_Hi
type offset bits
R
15
14
13
12
11
10
9
0x64
0
0
0
0
0
0
0
15
14
13
12
11
10
9
0x66
Power-up Defaults
8
7
6
5
4
3
2
1
0
FreeTimer[15:0]
0
0
0
0
0
0
0
0
0
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
FreeTimer[31:16]
0
0
0
0
0
0
0
0
0
The Free Running Timer register consists of two 16-bit registers. It is a 32-bit free
running up counter that counts at 100MHz and is used for transparent clock timestamps,
delay measurements, and redundancy timestamps. It can be used to compare how recent a
68
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
timestamp is using 32-bit unsigned arithmetic. At 100MHz the counter will reach the
same value from the starting point in about 42 seconds, and so comparisons are not valid
beyond that. When performing reads, FreeTmr_Lo should be read first, which will cause
the higher 16 bits of the internal Free Timer register to be latched. When FreeTmr_Hi is
read later, the latched value will be returned.
9.2.23 Periodic Interval Timer Register
Mnemonic
type offset bits
PITTmo_Lo
15
14
13
12
11
10
9
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
0
0
0
0
0
0
0
R/W 0x68
Power-up Defaults
Mnemonic
type offset bits
PITTmo_Hi
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
7
6
5
4
3
2
1
0
0
0
0
0
0
0
1
0
dlre
resv
0
0
PITTimeout[15:0]
R/W 0x6A
Power-up Defaults
8
PITTimeout[31:16]
0
0
0
The Periodic Interval Timer register consists of two 16-bit registers. It is a 32-bit down
counter that counts at 50MHz. When the PIT timer is enabled through the pite bit in the
Redundancy Control register, the value from this register is loaded into the timer and
countdown begins. When the timer reaches zero the pit bit in the Switch Event register is
set, and the timer is loaded with value from this register again for the next count down.
To prevent spurious interrupts, this register should be changed only when the pite bit is
reset in the Redundancy Control register. The periodic interval timer can be used to
provide an interrupt to generate ring beacons.
9.2.24 Redundancy Control Register
Mnemonic
type offset bits
Rdndnc_Control
15
R/W 0x6C
Power-up Defaults
0
14
13
12
11
raf
drm
cns
pite p2bte p1bte p2br p1br p2tb p2rb p1tb p1rb rspr
0
0
0
0
10
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
resv
Reserved, must be reset (0)
dlre
Device Level Ring Protocol Enable. When this bit is set, fido2100 will
support DLR protocol redundancy. If it is reset, fido2100 will not support ring
redundancy.
69
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
rspr
Ring Supervisor Enable. When this bit is set, fido2100 will support Ring
protocol redundancy as a ring supervisor. If it is reset, fido2100 will support
Ring protocol redundancy as a nonsupervisory device. Depending on the
setting of this bit, some logic will be enabled, some disabled and some function
differently. Details are described under appropriate sections.
p1rb
Port 1 Receive Blocked. When this bit is set all frames received on port 1 will
be dropped with the exception of following special frames. Ring beacon
frames will be forwarded to host CPU if p1br bit is set. Ring beacon frames
with source MAC address different from Ring Supervisor MAC ID register
will always be forwarded to host CPU. Ring Neighbor Check/Sign On
(multicast) frames will be forwarded to host CPU. Ring Link/Neighbor Status
frames or beacon Failure Notify frames with destination MAC address same as
host CPU MAC address will be forwarded to host CPU. Ring beacon frames
will be forwarded to port 2 if rspr bit is not set.
p1tb
Port 1 Transmit Blocked. When this bit is set no frames will be transmitted
on port 1 with the exception of following special frames. Ring beacon frames
from host CPU will be transmitted if rspr bit is set (i.e. ring beacon will be
transmitted on both ports). Ring Neighbor Check/Sign On (multicast) frames
from host CPU will be transmitted if source port in frame matches port 1. Ring
beacon frames from port 2 will be transmitted if rspr bit is not set.
p2rb
Port 2 Receive Blocked. When this bit is set all frames received on port 2 will
be dropped with the exception of following special frames. Ring beacon
frames will be forwarded to host CPU if p2br bit is set. Ring beacon frames
with source MAC address different from Ring Supervisor MAC ID register
will always be forwarded to host CPU. Ring Neighbor Check/Sign On
(multicast) frames will be forwarded to host CPU. Ring Link/Neighbor Status
frames or beacon Failure Notify frames with destination MAC address same as
host CPU MAC address will be forwarded to host CPU. Ring beacon frames
will be forwarded to port 1 if rspr bit is not set.
p2tb
Port 2 Transmit Blocked. When this bit is set no frames will be transmitted
on port 2 with the exception of following special frames. Ring beacon frames
from host CPU will be transmitted if rspr bit is set (i.e. ring beacon will be
transmitted on both ports). Ring Neighbor Check/Sign On (multicast) frames
from host CPU will be transmitted if source port in frame matches port 2. Ring
beacon frames from port 1 will be transmitted if rspr bit is not set.
p1br
Port 1 Beacon Receive. When this bit is set, Ring beacon frames received on
port 1 will be forwarded to host CPU. If this bit is reset, Ring beacons received
70
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
on port 1 will be dropped with following exception. Ring beacon frames with
source MAC address different from Ring Supervisor MAC ID register will
always be forwarded to host CPU.
p2br
Port 2 Beacon Receive. When this bit is set, Ring beacon frames received on
port 2 will be forwarded to host CPU. If this bit is reset, Ring beacons received
on port 2 will be dropped with following exception. Ring beacon frames with
source MAC address different from Ring Supervisor MAC ID register will
always be forwarded to host CPU.
p1bte
Port 1 Beacon Timeout Enable. When this bit is set, port 1 beacon timeout
timer is enabled. See Beacon Timeout register for details.
p2bte
Port 2 Beacon Timeout Enable. When this bit is set, port 2 beacon timeout
timer is enabled. See Beacon Timeout register for details.
pite
Periodic Interval Timer Enable. When this bit is set, periodic interval timer
is enabled. See Periodic Interval Timer register for details.
cns
Clear Neighbor Check Request/Sign On and Link/Neighbor Status
Receive Source ID Registers. When this bit is set, Neighbor Check
Request/Sign On and Link/Neighbor Status Receive Source ID registers for
both port 1 and port 2 will be cleared. This bit is self-clearing.
drm
Drop Reserved MAC addresses. When this bit is set, IEEE 802.1D reserved
MAC address 01-80-C2-00- 00-00 and Cisco PVST+ MAC address 01-00-0CCC-CC-CD will not be forwarded from any port to other ports.
raf
Receive Announce Frames. When this bit is set, ring Announce frames will
be forwarded to host CPU.
9.2.25 Ring Beacon State Register
Mnemonic
Rng_BcnState
type offset bits
R
15
14
0
0
0x6E
Power-up Defaults
13
12
11
10
9
8
7
6
0
0
0
0
RingBeaconState2[7:0]
0
0
0
0
5
4
3
2
1
0
0
0
RingBeaconState1[7:0]
0
0
0
0
The Ring Beacon State register contains the State Flags field captured from the last
beacon frame with the Ring Supervisor MAC ID register source address through ports 1
and 2. RingBeaconState1 contains the State field captured from the last beacon frame
through port 1 and RingBeaconState2 contains the State field captured from the last
71
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
beacon frame through port 2. A change of state in RingBeaconState1 causes the rbs1
IRQ in the Switch Event register and a change of state in RingBeaconState2 causes the
rbs2 IRQ in the Switch Event register.
9.2.26 Beacon Timeout Register
Mnemonic
BcnTmo_Lo
type offset bits
BcnTmo_Hi
14
13
12
11
10
9
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
0
0
0
0
0
0
R/W 0x70
Power-up Defaults
Mnemonic
15
type offset bits
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
6
5
4
3
2
1
0
0
0
0
0
0
0
BeaconTimeout[15:0]
R/W 0x72
Power-up Defaults
8
BeaconTimeout[31:16]
0
0
0
0
The Beacon Timeout register consists of two 16-bit registers. The timeout value is used
by both the port 1 beacon timeout timer and the port 2 beacon timeout timer. The beacon
timeout timers are 32-bit down counters that count at 50MHz. When the port 1 (or port 2)
beacon timeout timer is enabled through the p1bte ( or p2bte) bit in the Redundancy
Control register, the value from this register is loaded into respective timer and
countdown begins. When a Ring beacon is received on port 1 (or port 2) with the Ring
Supervisor MAC ID register source address, without a CRC error, the respective port’s
beacon timer is reloaded with the beacon timeout value and the countdown is started
again. If the timer reaches zero the bto1 (or bto2) bit in the Switch Event register is set
and the timer is loaded with the value from this register again for next count down. To
prevent spurious interrupts, this register should be changed only when the p1bte and
p2bte bits are reset in the Redundancy Control register.
9.2.27 Port 1 Beacon Receive Timestamp Register
Mnemonic
P1BcnTS_Lo
type offset bits
R
P1BcnTS_Hi
type offset bits
R
14
13
12
11
10
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
0
0
0
0
0
0
0x74
Power-up Defaults
Mnemonic
15
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
6
5
4
3
2
1
0
0
0
0
0
0
0
BeaconTimestamp1[15:0]
0x76
Power-up Defaults
9
BeaconTimestamp1[31:16]
72
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
The Port 1 Beacon Receive Timestamp register is comprised of two 16- bit registers. It
contains a snapshot of the Free Running Timer when last Ring beacon was received on
Port 1 with the Ring Supervisor MAC ID register source address. The two registers may
be read in any order. However, since the registers may be updated between two reads
when a new beacon is received, care should be taken to read the registers multiple times
and only consider it as valid when two successive reads produce the same result.
9.2.28 Port 2 Beacon Receive Timestamp Register
Mnemonic
type offset bits
P2BcnTS_Lo
R
type offset bits
P2BcnTS_Hi
R
14
13
12
11
10
0x78
Power-up Defaults
Mnemonic
15
8
7
6
5
4
3
2
1
0
BeaconTimestamp2[15:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0x7A
Power-up Defaults
9
BeaconTimestamp2[31:16]
0
0
0
0
0
0
0
0
0
0
The Port 2 Beacon Receive Timestamp register is comprised of two 16- bit registers. It
contains a snapshot of the Free Running Timer when the last ring beacon was received on
Port 2 with the Ring Supervisor MAC ID register source address. The two registers may
be read in any order. However, since the registers may be updated between two reads
when a new beacon is received, care should be taken to read the registers multiple times
and only consider it as valid when two successive reads produce the same result.
9.2.29 Port 1 Neighbor Check Request/Sign On Receive Source ID Register
Mnemonic
type offset bits
P1NChkSId_Lo_Lo
R
Power-up Defaults
Mnemonic
type offset bits
P1NChkSId_Lo_Hi
R
type offset bits
P1NChkSId_Hi_Lo
R
14
13
12
0
0
0
0
15
14
13
12
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
11
10
9
8
7
6
5
4
3
2
1
0
Port1_Neighbor_Check_Req_Recv_SrcID[31:16]
0
0
0
0
15
14
13
12
0x80
Power-up Defaults
11
Port1_Neighbor_Check_Req_Recv_SrcID[15:0]
0x7E
Power-up Defaults
Mnemonic
15
0x7C
0
0
0
0
0
0
0
0
0
0
0
0
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
Port1_Neighbor_Check_Req_Recv_SrcID[47:32]
0
0
0
0
0
73
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
The Port 1 Neighbor Check Request/Sign On Receive Source ID register is comprised of
three 16- bit registers. It contains the source MAC address of last Neighbor Check
Request/Sign On (multicast) frame that was received on port 1. Reads may be performed
in any order.
9.2.30 Port 2 Neighbor Check Request/Sign On Receive Source ID Register
Mnemonic
type offset bits
P2NChkSId_Lo_Lo
R
type offset bits
P2NChkSId_Lo_Hi
R
type offset bits
P2NChkSId_Hi_Lo
R
13
12
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Port2_Neighbor_Check_Req_Recv_SrcID[31:16]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0x86
Power-up Defaults
11
Port2_Neighbor_Check_Req_Recv_SrcID[15:0]
0x84
Power-up Defaults
Mnemonic
14
0x82
Power-up Defaults
Mnemonic
15
Port2_Neighbor_Check_Req_Recv_SrcID[47:32]
0
0
0
0
0
0
0
0
0
0
0
0
The Port 2 Neighbor Check Request/Sign On Receive Source ID register is comprised of
three 16- bit registers. It contains the source MAC address of last Neighbor Check
Request/Sign On (multicast) frame that was received on port 2. Reads may be performed
in any order.
9.2.31 Port 1 Link/Neighbor Status Receive Source ID Register
Mnemonic
type offset bits
P1NStsSId_Lo_Lo
R
Power-up Defaults
Mnemonic
type offset bits
P1NStsSId_Lo_Hi
R
type offset bits
P1NStsSId_Hi_Lo
R
14
13
12
11
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Port1_Neighbor_Status_Recv_SrcID[31:16]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0x8C
Power-up Defaults
10
Port1_Neighbor_Status_Recv_SrcID[15:0]
0x8A
Power-up Defaults
Mnemonic
15
0x88
Port1_Neighbor_Status_Recv_SrcID[47:32]
0
0
0
0
0
74
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
The Port 1 Link/Neighbor Status Receive Source ID register is comprised of three 16- bit
registers. It contains the source MAC address of the last Link/Neighbor Status frame that
was received on port 1. Reads may be performed in any order.
9.2.32 Port 2 Link/Neighbor Status Receive Source ID Register
Mnemonic
type offset bits
P2NStsSId_Lo_Lo
R
type offset bits
P2NStsSId_Lo_Hi
R
type offset bits
P2NStsSId_Hi_Lo
R
13
12
11
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
0
0
0
0
0
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
Port2_Neighbor_Status_Recv_SrcID[31:16]
0x92
Power-up Defaults
10
Port2_Neighbor_Status_Recv_SrcID[15:0]
0x90
Power-up Defaults
Mnemonic
14
0x8E
Power-up Defaults
Mnemonic
15
Port2_Neighbor_Status_Recv_SrcID[47:32]
0
0
0
0
0
0
0
The Port 2 Link/Neighbor Status Receive Source ID register is comprised of three 16- bit
registers. It contains the source MAC address of the last Link/Neighbor Status frame that
was received on port 2. Reads may be performed in any order.
9.2.33 Ring Supervisor MAC ID Register
Mnemonic
type offset bits
RngSprvsrId_Lo_Lo
R
Power-up Defaults
Mnemonic
type offset bits
RngSprvsrId_Lo_Hi
R
Mnemonic
type offset bits
R
14
13
12
11
10
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Ring_Supervisor_MacId[31:16]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0x98
Power-up Defaults
9
Ring_Supervisor_MacId[15:0]
0x96
Power-up Defaults
RngSprvsrId_Hi_Lo
15
0x94
Ring_Supervisor_MacId[47:32]
0
0
0
0
0
75
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
The Ring Supervisor MAC ID register is comprised of three 16- bit registers. It contains
the source MAC address of active ring supervisor. This register must be set to the proper
value in both ring supervisor and non-supervisor modes of operation, for the ring logic to
function correctly. For example to load MAC address 00-11-22-33-44-55, 0x0011 should
be written to RngSprvsrId_Hi_Lo, 0x2233 should be written to RngSprvsrId _Lo_Hi, and
0x4455 should be written to RngSprvsrId _Lo_Lo. Reads and writes may be performed in
any order.
9.2.34 Interface and Media Counters Registers
Mnemonic
type offset bits
P1RxGrpFrmCnt
R
type offset bits
P2RxGrpFrmCnt
R
type offset bits
P1RxUniFrmCnt
R
type offset bits
P2RxUniFrmCnt
R
type offset bits
P1RxBytCnt_Lo
R
type offset bits
P1RxBytCnt_Hi
R
Mnemonic
type offset bits
P2RxBytCnt_Lo
R
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Port2_Group_Frame_Recv_Count[15:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Port1_Unicast_Frame_Recv_Count[15:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Port1_Unicast_Frame_Recv_Count[15:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Port1_Recv_Byte_Count[15:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
Port1_Recv_Byte_Count[31:16]
0xA8
Power-up Defaults
9
0
0xA6
Power-up Defaults
10
Port1_Group_Frame_Recv_Count[15:0]
0xA4
Power-up Defaults
Mnemonic
11
0xA2
Power-up Defaults
Mnemonic
12
0xA0
Power-up Defaults
Mnemonic
13
0x9E
Power-up Defaults
Mnemonic
14
0x9C
Power-up Defaults
Mnemonic
15
Port2_Recv_Byte_Count[15:0]
76
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Mnemonic
type offset bits
P2RxBytCnt_Hi
R
Mnemonic
type offset bits
P1RxLrgFrmCnt
R
type offset bits
P2RxLrgFrmCnt
R
type offset bits
P1RxAlnFrmCnt
R
type offset bits
P2RxAlnFrmCnt
R
Mnemonic
type offset bits
R
Mnemonic
type offset bits
R
Mnemonic
type offset bits
R
Mnemonic
type offset bits
R
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
0
0
0
0
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Port1_Large_Error_Frame_Recv_Count[15:0]
Port2_Large_Error_Frame_Recv_Count[15:0]
Port1_Align_Error_Frame_Recv_Count[15:0]
Port2_Align_Error_Frame_Recv_Count[15:0]
Port1_FCS_Error_Frame_Recv_Count[15:0]
Port2_FCS_Error_Frame_Recv_Count[15:0]
0
0
0
0
0
15
14
13
12
11
0
0
0
0
0
0
0
0
0
0
0
10
9
8
7
6
5
4
3
2
1
0
Port1_Recv_Error_Frame_Count[15:0]
0
0
0
0
0
15
14
13
12
11
0xBA
Power-up Defaults
9
Port2_Recv_Byte_Count[31:16]
0xB8
Power-up Defaults
P2RxErrFrmCnt
0
0xB6
Power-up Defaults
P1RxErrFrmCnt
10
0xB4
Power-up Defaults
P2RxFcsFrmCnt
11
0xB2
Power-up Defaults
P1RxFcsFrmCnt
12
0xB0
Power-up Defaults
Mnemonic
13
0xAE
Power-up Defaults
Mnemonic
14
0xAC
Power-up Defaults
Mnemonic
15
0xAA
Power-up Defaults
April 10, 2013
0
0
0
0
0
0
0
0
0
0
0
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
Port2_Recv_Error_Frame_Count[15:0]
0
0
0
0
0
77
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Mnemonic
type offset bits
P1TxGrpFrmCnt
R
Mnemonic
type offset bits
P2TxGrpFrmCnt
R
type offset bits
P1TxUniFrmCnt
R
type offset bits
P2TxUniFrmCnt
R
type offset bits
P1TxBytCnt_Lo
R
Mnemonic
type offset bits
R
Mnemonic
type offset bits
R
Mnemonic
type offset bits
R
Mnemonic
type offset bits
R
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
0
0
0
0
0
8
7
6
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
0
0
0
0
0
0
15
14
13
12
11
10
5
4
3
2
1
0
0
0
0
0
0
0
5
4
3
2
1
0
0
0
0
0
0
0
5
4
3
2
1
0
0
0
0
0
0
0
5
4
3
2
1
0
0
0
0
0
0
0
5
4
3
2
1
0
0
0
0
0
0
0
0
6
5
4
3
2
1
0
Port2_Group_Frame_Xmit_Count[15:0]
Port1_Unicast_Frame_Xmit_Count[15:0]
Port2_Unicast_Frame_Xmit_Count[15:0]
Port1_Xmit_Byte_Count[15:0]
Port1_Xmit_Byte_Count[31:16]
0
0
0
0
0
0
0
0
0
0
9
8
7
6
5
4
3
2
1
0
Port2_Xmit_Byte_Count[15:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Port2_Xmit_Byte_Count[31:16]
0
0
0
0
15
14
13
12
0xCC
Power-up Defaults
9
Port1_Group_Frame_Xmit_Count[15:0]
0xCA
Power-up Defaults
P1TxSClFrmCnt
0
0xC8
Power-up Defaults
P2TxBytCnt_Hi
0
0xC6
Power-up Defaults
P2TxBytCnt_Lo
11
0xC4
Power-up Defaults
P1TxBytCnt_Hi
12
0xC2
Power-up Defaults
Mnemonic
13
0xC0
Power-up Defaults
Mnemonic
14
0xBE
Power-up Defaults
Mnemonic
15
0xBC
Power-up Defaults
10
April 10, 2013
0
0
0
0
0
0
0
0
0
0
0
0
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
Port1_Xmit_Single_Collision_Frame_Count[15:0]
0
0
0
0
0
78
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
0
0
0
0
0
0
0
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
Mnemonic
type offset bits
P2TxSClFrmCnt
R
Mnemonic
type offset bits
P1TxMClFrmCnt
R
type offset bits
P2TxMClFrmCnt
R
type offset bits
P1TxXClFrmCnt
R
type offset bits
P2TxXClFrmCnt
R
Mnemonic
type offset bits
R
Mnemonic
type offset bits
R
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
0
0
0
0
9
8
7
6
5
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
0
0
0
0
0
15
14
13
12
11
4
3
2
1
0
0
0
0
0
0
4
3
2
1
0
0
0
0
0
0
4
3
2
1
0
0
0
0
0
0
4
3
2
1
0
0
0
0
0
0
4
3
2
1
0
0
0
0
0
0
4
3
2
1
0
Port1_Xmit_Multiple_Collision_Frame_Count[15:0]
Port2_Xmit_Multiple_Collision_Frame_Count[15:0]
Port1_Xmit_Excessive_Collision_Frame_Count[15:0]
Port2_Xmit_Excessive_Collision_Frame_Count[15:0]
Port1_Xmit_Error_Frame_Count[15:0]
0xDA
Power-up Defaults
10
Port2_Xmit_Single_Collision_Frame_Count[15:0]
0xD8
Power-up Defaults
P2TxErrFrmCnt
0
0xD6
Power-up Defaults
P1TxErrFrmCnt
12
0xD4
Power-up Defaults
Mnemonic
13
0xD2
Power-up Defaults
Mnemonic
14
0xD0
Power-up Defaults
Mnemonic
15
0xCE
Power-up Defaults
11
April 10, 2013
0
0
0
0
0
0
0
0
0
0
0
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
Port2_Xmit_Error_Frame_Count[15:0]
0
0
0
0
0
0
0
0
0
0
0
The Interface and Media counters registers can be used to implement EtherNet/IP link
object. To avoid a rollover issue with these registers, the firmware should scan these
registers at least once every 200 milliseconds or on demand, and calculate the increase in
counters using unsigned 16-bit arithmetic. The computed increase must be added to
firmware maintained 32-bit counters of the EtherNet/IP link object. The counters can be
reset by resetting the respective port.

P1RxGrpFrmCnt : This 16-bit counter reflects multicast and broadcast frames
received without errors on port 1.
79
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013

P2RxGrpFrmCnt: This 16-bit counter reflects multicast and broadcast frames
received without errors on port 2.

P1RxUniFrmCnt: This 16-bit counter reflects unicast frames received without
errors on port 1.

P2RxUniFrmCnt: This 16-bit counter reflects unicast frames received without
errors on port 2.

P1RxBytCnt: This 32-bit counter reflects byte count of unicast, multicast and
broadcast frames received without errors on port 1. Since this register may be
updated while the reads are under progress, this counter must be read twice. Only
when two successive reads produce same result should the value be used.

P2RxBytCnt: This 32-bit counter reflects byte count of unicast, multicast and
broadcast frames received without errors on port 2. Since this register may be
updated while the reads are under progress, this counter must be read twice. Only
when two successive reads produce same result should the value be used.

P1RxLrgFrmCnt: This 16-bit counter reflects frames larger than 1522 bytes
including CRC received on port 1. Such frames are not IEEE 802.3 compliant.

P2RxLrgFrmCnt: This 16-bit counter reflects frames larger than 1522 bytes
including CRC received on port 2. Such frames are not IEEE 802.3 compliant.

P1RxAlnFrmCnt: This 16-bit counter reflects frames with alignment error i.e. nonintegral number of bytes received on port 1.

P2RxAlnFrmCnt: This 16-bit counter reflects frames with alignment error i.e. nonintegral number of bytes received on port 2.

P1RxFcsFrmCnt: This 16-bit counter reflects frames with frame check sequence
(CRC) error received on port 1.

P2RxFcsFrmCnt: This 16-bit counter reflects frames with frame check sequence
(CRC) error received on port 2.

P1RxErrFrmCnt: This 16-bit counter reflects frames with other errors including
frames shorter than 64 bytes received on port 1.

P2RxErrFrmCnt: This 16-bit counter reflects frames with other errors including
frames shorter than 64 bytes received on port 2.
80
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013

P1TxGrpFrmCnt: This 16-bit counter reflects multicast and broadcast frames
transmitted without errors on port 1.

P2TxGrpFrmCnt: This 16-bit counter reflects multicast and broadcast frames
transmitted without errors on port 2.

P1TxUniFrmCnt: This 16-bit counter reflects unicast frames transmitted without
errors on port 1.

P2TxUniFrmCnt: This 16-bit counter reflects unicast frames transmitted without
errors on port 2.

P1TxBytCnt: This 32-bit counter reflects byte count of unicast, multicast and
broadcast frames transmitted without errors on port 1. Since this register may be
updated while the reads are under progress, this counter must be read twice and only
when two successive reads produce same result should the value be used.

P2TxBytCnt: This 32 bit counter reflects byte count of unicast, multicast and
broadcast frames transmitted without errors on port 2. Since this register may be
updated while the reads are under progress, this counter must be read twice and only
when two successive reads produce same result should the value be used.

P1TxSClFrmCnt: This 16-bit counter reflects frames transmitted after exactly one
collision in half duplex mode on port 1.

P2TxSClFrmCnt: This 16-bit counter reflects frames transmitted after exactly one
collision in half duplex mode on port 2.

P1TxMClFrmCnt: This 16-bit counter reflects frames transmitted after more than
one collision in half duplex mode on port 1.

P2TxMClFrmCnt: This 16-bit counter reflects frames transmitted after more than
one collision in half duplex mode on port 2.

P1TxXClFrmCnt: This 16-bit counter reflects frames dropped after excessive (16)
collisions in half duplex mode on port 1.

P2TxXClFrmCnt: This 16-bit counter reflects frames dropped after excessive (16)
collisions in half duplex mode on port 2.

P1TxErrFrmCnt: This 16-bit counter reflects frames truncated with error during
transmission on port 1.
81
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet

April 10, 2013
P2TxErrFrmCnt: This 16-bit counter reflects frames truncated with error during
transmission on port 2.
9.2.35 Beacon Generation Control Register
Mnemonic
type offset bits
BcnGenCntrl
R/W 0xDC
Power-up Defaults
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
bgrst bge2 bge1 bite
0
0
0
0
0
0
0
0
0
0
0
0
0
0
bite
Beacon Interval Timer Enable. When this bit is set, beacon interval timer is
enabled. It’s a periodic timer and when the interval expires, beacon generation
is triggered if bge1/bge2 are set and the timer is restarted. In order to
immediately trigger a beacon frame on ports, this bit should be reset and set.
bge1
Beacon Generation Enable for Port 1. When this bit is set, DLR beacon
frame generation is enabled on port 1. Frame sequence ID will be
automatically generated.
bge2
Beacon Generation Enable for Port 2. When this bit is set, DLR beacon
frame generation is enabled on port 2. Frame sequence ID will be
automatically generated.
bgrst
Beacon Generation Reset. When this bit is set, all beacon frame generation
logic will be held in reset.
0
0
9.2.36 Beacon Interval Register
Mnemonic
type offset bits
BcnIntrvl_Lo
R/W 0xDE
Power-up Defaults
Mnemonic
type offset bits
BcnIntrvl_Hi
R/W 0xE0
Power-up Defaults
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
BeaconInterval[15:0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
BeaconInterval[31:16]
0
0
0
0
0
0
0
0
0
0
The Beacon Interval register consists of two 16-bit registers. It is a 32-bit counter that
counts at 50MHz and is used to trigger beacon frame generation on port(s) when it is
enabled and expires. See bite bit in Beacon Generation Control register for more details.
82
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
9.2.37 Beacon Frame Data Index and Value Registers
Mnemonic
BcnDataIdx
type offset bits
BcnDataVal
14
13
12
11
10
9
8
7
6
5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W 0xE2
Power-up Defaults
Mnemonic
15
type offset bits
3
2
1
0
BeaconDataIndex[5:0]
R/W 0xE4
Power-up Defaults
4
BeaconDataValue[7:0]
0
0
0
0
The Beacon Frame Data Index and Value registers provide the means to define
appropriate contents for the DLR beacon frame. For DLR beacon frames, bytes 0 to 39
must be defined. The sequence Id for beacon frame will be automatically generated and
will be inserted at correct position. Note that byte index greater than or equal to 40 should
not be defined.
9.2.38 fido2100 Version Register
Mnemonic
EmbSwtchVer
type offset bits
R
15
14
13
0
0
0
0xE6
Power-up Defaults
12
11
10
9
8
7
6
5
0
1
0
0
1
MajorVersion[7:0]
0
0
0
4
3
2
1
0
0
1
MinorVersion[7:0]
1
1
1
The fido2100 Version Register is a read only register that provides major and minor
version information.
83
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184
fido2100 3-Port Industrial Ethernet DLR Switch with IEEE1588
Data Sheet
April 10, 2013
10 Revision History
Table 16 Document Revision History
Date
Revision
Description
September 10, 2012
00
First edition released.
NA
October 1, 2012
01
Updated Section 5.1 PLL Supply.
37
December 3, 2012
02
Added Thermal Characteristics and Power
Consumption Information.
37, 38
February 12, 2013
03
April 10, 2013
04
Corrected cut-through times (changed ns to
µs)
Clarified junction temperature parameter
name
Page(s)
19
37
11 For Additional Information
The Innovasic Support Team is continually planning and creating tools for your use. Visit
http://www.innovasic.com for up-to-date documentation and software. Our goal is to provide
timely, complete, accurate, useful, and easy-to-understand information. Please feel free to
contact our experts at Innovasic at any time with suggestions, comments, or questions.
Innovasic Support Team
5635 Jefferson St. NE, Suite A
Albuquerque, NM 87109
Phone: +1-505-883-5263
Fax: (505) 883-5477
Toll Free: (888) 824-4184 US
E-mail: [email protected]
Website: http://www.innovasic.com
84
Document #: IA211111101-04
UNCONTROLLED WHEN PRINTED OR COPIED
[email protected]
1-505-883-5263
1-888-824-4184