WRB-YQD-30W Series W, WIDE INPUT, ISOLATED & REGULATED SINGLE OUTPUT DC 30 30W, DC--DC CONVERTER SELECTION GUIDE FEATURES ◆Wide 2:1 DC input range ◆In/out capacitance1000pF ◆Protections : Short circuit / Overload / Over voltage ◆1000VDC I/O isolation for D/D ◆Cooling by free air convection Order code Input voltage range Output voltage Output current max. Efficiency typ. WRB1203YQD-5000 9.2 ~ 18 VDC 3.3VDC 5000mA 77 WRB1205YQD-5000 9.2 ~ 18 VDC 5VDC 5000mA 77 WRB1212YQD-2100 9.2 ~ 18 VDC 12VDC 2100mA 80 WRB1215YQD-1700 9.2 ~ 18 VDC 15VDC 1700mA 80 WRB2403YQD-5000 18~ 36 VDC 3.3VDC 5000mA 79 WRB2405YQD-5000 18~ 36 VDC 5VDC 5000mA 79 WRB2412YQD-30W 18~ 36 VDC 12VDC 2500mA 82 WRB2415YQD-30W 18~ 36 VDC 15VDC 2000mA 83 WRB4803YQD-5000 36~ 72 VDC 3.3VDC 5000mA 80 WRB4805YQD-5000 36~ 72 VDC 5VDC 5000mA 80 WRB4812YQD-30W 36~ 72 VDC 12VDC 2500mA 84 WRB4815YQD-30W 36~ 72 VDC 15VDC 2000mA 85 ◆Built-in remote ON-OFF control ◆100% full load burn-in test SPECIFICATION ◆Fixed switching frequency at 225KHz INPUT ◆Lost cost ◆MTBF>1000Khours ◆High reliability ◆1 year warranty PROTECTION ② ③ ④ ⑤ ⑥ ① ② ③ ④ ⑤ ⑥ WRB 12 12 Y QD -30W FUNCTION ①Product Series ②Input Voltage ③Output Voltage ④Wide (2:1) Input Range ⑤DIP Package Style ⑥Rated Power ENVIRONMENT APPLICATIONS The WRB-YQD-30W Series series of 12S:3.6A 24S:2A 48S:1A IDLE CURRENT 12S:35mA 24S/48S:30mA OVERLOAD Above 105% rated output power Protection type : Over power limiting, recovers automatically after fault condition is removed OVER VOLTAGE WRBXX03:3.8 ~ WRBXX05:5.75 ~ 7.5V WRBXX12:13.8 ~ 18V WRBXX15:17.25 ~ 22.5V Protection type : Shut off o/p voltage, clamping by zener MODEL SELECTION ① DC CURRENT DC/DC converters has been designed for a wide range of applications including communications, industrial systems SAFETY &EMC (Note 6) and battery powered mobile equipments. Key features are high power density (12W in a 2“x1“x 0.4“ package) and ultrawide input ranges of 9 – 36 VDC and 18 –75 VDC. Other features of this converter are internal filtering OTHERS according to EN 55022, level A, safety approval to EN 60950 and UL 1950, wide operating temperature range and remote on/off (opt.). NOTE SHORT CIRCUIT Protection type : Constant current limiting, recovers automatically after fault condition is removed ON/OFF CONTROL Logic "1" or open: power on power off WORKING TEMP. -25 ~ +85℃ (Refer to output load derating curve) STORAGE TEMP., HUMIDITY -25 ~ +85℃, 0 ~ 95% RH TEMP. COEFFICIENT SAFETY STANDARDS ISOLATION VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Logic "0" short to Vin-: ±0.03%/ ℃(0~50℃) Design refer to LVD I/P-O/P:1KVDC I/P-O/P:100M Ohms/500VDC Compliance to EN55022 (CISPR22) Class B EMS IMMUNITY Compliance to EN61000-2,3,4,6,8; ENV50204, EN55024, light industry level,criteria A MTBF 322.4K hrs min. DIMENSION 50.8*50.8*16mm (2"*2"*0.63") (L*W*H) PACKING 0.1Kg; 150pcs/15.8Kg/0.97CUFT MIL-HDBK-217F (25℃) 1. All parameters NOT specially mentioned are measured at 12,24,48VDC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Short circuit not more than 60 second. 5. DC source wires 5cm, an input external al capacitor 47 ~ 100uF is required. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. MICRODC reserves the copyright http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 page 1/3 WRB-YQD-30W Series Mechanical Specification TYPICAL CHARACTERISTICS Temperature Derating Graph RECOMMENDED CIRCUIT Output Graph APPLICATION NOTE External Output Trimming Requirement on output load In order to ensure the product operate efficiently and reliably,in addition to a max load(namely full load), a minimum load is specified for this kind of DC/DC converter.Make sure the specified range of input voltage is not exceeded,the minimum output load no less than 10% load.If the actual load is less than the specified minimum load, the output ripple may increase sharply while its efficiency and reliability will reduce greatly.If the actual output power is very small,please add an appropriate resistor as extra loading,or contact our company for other lower output power products. Recommended Circuit All the WRB_YQD-30W Series have been tested according to the following recommended testing circuit before leaving factory.This series should be tested under load(see Figure 1). If you want to further decrease the input/output ripple,you can increase capacitance properly or choose capacitors with low ESR.However,the capacitance of the output filter capacitor must be proper.If the capacitance is too big,a startup problem might arise.For every channel of output,provided the safe and reliable operation is ensured,the greatest capacitance of its filter capacitor sees (Table 1).General: Cin: 10μF-47μF Cout: 10μF/100mA ON/OFF Control Pin CONTROL INPUT.....................................PIN4 CONTROL COMMON................................PIN2 LOGIC COMPATIBILITY......CMOS OR OPEN COLLECTOR TTL CONTROL VOLTAGE ON............+5.5VDC min OR OPEN CIRCUIT OFF......+2.5VDC max. OR SHORT TO PIN2 CTRL Terminal When open or high impedance,the converter work well; When this pin is ‘high’; the converter shutdown; It should be note that the input current (Ic) should between 5-10mA, exceeding the maximum 20mA will cause permanence damage to the converter. The value of R Can be derived as follows : Input current While using unstable power source,please ensure the output voltage and ripple voltage do not exceed indexes of the converter.The preceding power source must be able to provide for converter sufficient starting current Ip(Figure 2). General:Ip≤1.6*Iin-max No parallel connection or plug and play http://www.microdc.cn Pin No. Assignment No. Assignme nt No. Assignmen t 1 +Vin 6 +Vout 2 -Vin 7 -Vout 3,5 No pin 8 Trim 4 Control ON/OFF Pin Pin Technical enquiries-Email:[email protected] Tel:0086-20-86000646 page 2/3 WRB-YQD-30W Series OUTLINE DIMENSIONS & FOOTPRINT DETAILS RECOMMENDED FOOTPRINT TUBE OUTLINE DIMENSIONS Unit :mm[inch] General tolerances:±0.50mm[±0.020inch] L=230mm[9.055inch] Tube Quantity: 7pcs RoHS COMPLIANT INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this series are backward compatible with Sn/Pb soldering systems. Microdc Professional Power Module,Inc. Tel:0086-20-86000646 REACH COMPLIANT INFORMATION E-mail:[email protected] Website:http://www.microdc.cn http://www.microdc.cn This series has proven that this product does not contain harmful chemicals, it also has harmful chemical substances through the registration, inspection and approval. Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 page 3/3