MICRODC WRA-ZD-8W

WRA-ZD-8W&WRB-ZD -8W Series
8W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC
DC--DC CONVERTER
SELECTION GUIDE
Order code
Input voltage
range
Output voltage
Output current
max.
Efficiency typ.
WRB2403ZD-8W
9 – 36 VDC
3.3 VDC
2400 mA
85 %
WRB2403ZD-8W
9 – 36 VDC
5 VDC
1600 mA
87 %
FEATURES
WRB2412ZD-8W
9 – 36 VDC
12 VDC
666 mA
86 %
WRB2415ZD-8W
9 – 36 VDC
15 VDC
533 mA
86 %
◆Wide (4:1) Input Range
WRA2405ZD-8W
9 – 36 VDC
±5 VDC
±800 mA
84 %
WRA2412ZD-8W
9 – 36 VDC
±12 VDC
±333 mA
86 %
WRA2415ZD-8W
9 – 36 VDC
±15 VDC
±267 mA
86 %
◆1500VDC Isolation
WRB4803ZD-8W
18 – 75 VDC
3.3 VDC
2400 mA
85 %
WRB4805ZD-8W
18 – 75 VDC
5 VDC
1600 mA
87 %
◆Operating Temperature: -40℃~﹢85℃
WRB4812ZD-8W
18 – 75 VDC
12 VDC
666 mA
87 %
WRB4815ZD-8W
18 – 75 VDC
15 VDC
533 mA
88 %
WRA4805ZD-8W
18 – 75 VDC
±5 VDC
±800 mA
84 %
WRA4812ZD-8W
18 – 75 VDC
±12 VDC
±333 mA
87 %
WRA4815ZD-8W
18 – 75 VDC
±15 VDC
±267 mA
87 %
WRB7203ZD-8W
43 – 160 VDC
3.3 VDC
2400 mA
84 %
◆3-year product warranty
WRB7205ZD-8W
43 – 160 VDC
5 VDC
1600 mA
85 %
WRB7512ZD-8W
43 – 160 VDC
12 VDC
666 mA
86 %
◆Internal SMD construction
WRB7515ZD-8W
43 – 160 VDC
15 VDC
533 mA
86 %
◆RoHS Compliance
WRA7205ZD-8W
43 – 160 VDC
±5 VDC
±800 mA
82 %
WRA7212ZD-8W
43 – 160 VDC
±12 VDC
±333 mA
85 %
WRA7215ZD-8W
43 – 160 VDC
±15 VDC
±267 mA
85 %
◆DIP-24 metal package
◆High efficiency up to 88 %
◆Remote On/Off
◆No minimum load required
◆MTBF>1000Khours
*Input voltage can’t exceed this value,or will cause the permanent damage.
MODEL SELECTION
①
②
③ ④
⑤
⑥
WRB 24 12 Z D -8W(666)
①Product Series
③Output Voltage
⑤DIP Package Style
②Input Voltage
④Wide (4:1) Input Range
⑥ Rated Power
General Specifications
Temperature ranges
– Operating
–40°C to +85°C
– Case temperature
+105°C max.
– Storage
–55°C to +125°C
Power derating
Thermal inpedance
3 %/K above +70°C
– Natural convection
18.2°C/W
– Natural convection with heat sink
15.8°C/W
Humidity (non condensing)
APPLICATIONS
The WRA-ZD-8W & WRB-ZD-8W series is a family of high
5 – 95 % rel. H max.
Isolation voltage(60 sec.)
– Input / Output
1500 VDC
Isolation resistance
– Input / Output
>1000 M Ohm
Isolation capacitance
– Input / Output
performance 8 Watt dc/dc converter modules featuring ultra wide
Switching frequency
4:1
with
Thermal shock, mechanical shock & vibration
industry-standard footprint. Input voltages up to 160 VDC,
– Test conditions
input
voltage
ranges
in
a
DIP-24
package
excellent EMC characteristics and EN 50155 approval make this
Safety standards
product the best choice for many demanding applications in
Safety approvals
– UL/cUL
railroad and transportation systems. Further standard features
Remote On/Off
– On:
http://microdc.cn/uploadfiles/WRA-ZD-8W&WRB-ZD-8W.PDF
UL/cUL 60950-1, IEC/EN 60950-1, EN 50155
– Off:
include remote On/Off, over voltage protection, under voltage
1500 pF max.
300 kHz typ. (pulse width modulation PWM)
3.0 ... 12 VDC or open circuit
0 ... 1.2 VDC or short circuit pin 1 and pin 2/3
– Off idle current:
lockout and short circuit protection. Typical applications for these
2.5 mA
converters are also in wireless networks, telecom/datacom,
Reliability, calculated MTBF(MIL-HDBK-217F, at +25°C, ground benign)
industry control systems and measurement equipments.
Environmental
1 Mio. h
– Reach
– RoHS
RoHS directive 2002/95/EC
Physical Specification
MICRODC reserves the copyright
http://www.microdc.cn
Casing material
copper, nickel plated
Baseplate material
non conductive FR4
Potting material
epoxy (UL94V-0 rated)
Weight
18 g (0.63 oz)
Soldering temperature
max. 265°C / 10 sec.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
page 1/4
WRA-ZD-8W&WRB-ZD -8W Series
Input Specifications
Input current (no load)
9–36 Vin, 3.3 VDC & 5 VDC models:
40 mA typ.
9–36 Vin other models:
25 mA typ.
18–75 Vin, 3.3 VDC & 5 VDC models:
20 mA typ.
18–75 Vin other models:
13 mA typ.
43–160 Vin, 3.3 VDC & 5 VDC models:
8 mA typ.
43–160 Vin other models:
5 mA typ.
Input current (full load)
9–36 Vin models:
410 mA typ
18–75 Vin models:
210 mA typ
43–160 Vin models:
90 mA typ.
Input voltage variation (dv/dt)
5 V/ms, max.
(complies with ETS300 132 part 4.4)
Start-up voltage
Under voltage shut down (lock-out circuit)
Surge voltage (100 msec. max.)
9–36 Vin models:
9.0 VDC (or lower)
18–75 Vin models:
18 VDC (or lower)
43–160 Vin models:
43 VDC (or lower)
9–36 Vin models:
8.0 VDC typ.
18–75 Vin models:
16 VDC typ.
43–160 Vin models:
42 VDC typ.
9–36 Vin models:
50 V max.
18–75 Vin models:
100 V max.
43–160 Vin models:
170 V max.
Reflected ripple current
20 mAp-p typ.
EN 55022 class A with external components
Conducted noise
see application note:
ESD (electrostatic discharge)
EN 61000-4-2, air ±8 kV, contact ±6 kV,perf. criteria A
Radiated immunity
EN 61000-4-3, 20 V/m, perf. criteria A
Fast transient / surge (with external input
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV perf. criteria A
capacitor)
– external input capacitor
24/48 Vin models:
110 Vin models:
Conducted immunity
Nippon chemi-con KY 220 µF, 100 V, ESR 48 mOhm
Nippon chemi-con KX J 150 µF, 200 V, ESR 48 mOhm
EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy
±1 %
Regulation
– Input variation Vin min. to Vin max.
– Load variation 0 – 100 %
single output models:
dual output models:
– Load cross variation 25 % / 100 %
0.2 % max.
0.5 % max.
1 % max.
5 % max.
Minimum load
not required
Temperature coefficient
±0.02 %/K
Ripple and noise (20 MHz bandwidth)
24/48 Vin models:
50 mVp-p typ.
110 Vin models:
75 mVp-p typ.
Start up time
– Power On
450 ms typ.
(constant resistive load)
– Remote On
5 ms typ.
Transient Response(25% load step change)
250 µs typ.
Short circuit protection
indefinite (automatic recovery)
Over load protection
150 % of Iout max. typ.
Over voltage protection(only single output models)
Capacitive load
3.9 V
5 V output:
6.2 V
12 V output:
15 V
15 V output:
18 V
3.3 VDC & 5 VDC models:
TEMPERATURE CHARACTERISTICS
http://www.microdc.cn
3.3 V output:
1330 µF
12 VDC models:
288 µF
15 VDC models:
200 µF
±5 VDC models:
900 µF (each output)
±12 VDC models:
133 µF (each output)
±15 VDC models:
90 µF (each output)
TYPICAL CHARACTERISTICS
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
page 2/4
WRA-ZD-8W&WRB-ZD -8W Series
Parameter
Conditions
Min.
Output power
See below products program
0.6
Positive voltage accuracy
Refer to recommended circuit
Negative voltage accuracy
Typ.
Max.
Units
6
W
±1
±3
%
Refer to recommended circuit
±3
±5
%
Load regulation
Form 10% to 100% load
±0.5
±2*
%
Line regulation
Input voltage from low to high
±0.2
±0.5
%
Temperature drift (Vout)
Refer to recommended circuit
±0.02
Ripple**
20MHz Bandwidth
20
50
mVp-p
Noise**
20MHz Bandwidth
50
100
mVp-p
Switching frequency
100% load, input voltage range
300
Temperature Derating Graph
%/℃
KHz
RECOMMENDED CIRCUIT
* Dual output models unbalanced load: ±5%.
Output Graph
** Test ripple and noise by “parallel cable” method. See detailed operation instructions at
Testing of Power Converter section, application notes.
Case material
APPLICATION NOTE
Requirement on output load
In order to ensure the product operate efficiently and reliably,in addition to a
max load(namely full load), a minimum load is specified for this kind of
DC/DC converter.Make sure the specified range of input voltage is not
exceeded,the minimum output load no less than 10% load
load.If the actual
load is less than the specified minimum load, the output ripple may increase
sharply while its efficiency and reliability will reduce greatly.If the actual
output power is very small,please add an appropriate resistor as extra
loading,or contact our company for other lower output power products.
Recommended Circuit
All the WRA_ZD-8W&WRB_ZD-8W Series have been tested according to
the following recommended testing circuit before leaving factory.This series
should be tested under load(see Figure 1).
If you want to further decrease the input/output ripple,you can increase
capacitance properly or choose capacitors with low ESR. However, the
capacitance should not be too high, or may cause start-up problem.
General:
Cin: 24V&48V 10μF-47μF
Cout: 10μF/100mA
Input current
Output External Capacitor Table(Table 1)
While using unstable power source,please ensure the output voltage and
ripple voltage do not exceed indexes of the converter.The preceding power
source must be able to provide for converter sufficient starting current
Ip(Figure 2).
General:Ip≤1.6*Iin-max
No parallel connection or plug and play
Single Vout
Cout
Dual Vout
Cout
(VDC)
(μF)
(VDC)
(μF)
3.3
2200
±5
680
5
1000
±12
330
12
470
±15
220
15
330
--
--
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
page 3/4
WRA-ZD-8W&WRB-ZD -8W Series
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT
Note:
Unit:mm[inch]
Pin section tolerances:±0.10mm[±0.004inch]
General tolerances:±0.25mm[±0.010inch]
RECOMMENDED FOOTPRINT
Top view grid:2.54mm(0.1inch)
diameter:1.00mm(0.039inch)
TUBE OUTLINE DIMENSIONS
FOOTPRINT DETAILS
Pin
Single
Dual
2、3
GND
GND
9
NC
0V
11
NC
-Vo
14
+Vo
+Vo
16
0V
0V
22、23
Vin
Vin
NC:No connection
When the environment temperature is higher than
71
71℃,, the product output power should be less
then 60% of the rated power.
No parallel connection or plug and play.
Use dual output simultaneously,forbid pening
output pin (0V) to use as single output.
Note:
Note:
Unit :mm[inch]
General tolerances:±0.50mm[±0.020inch]
L=530mm[20.866inch] Tube Quantity: 15pcs
L=220mm[8.661inch] Tube Quantity: 6pcs
1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed.
3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise
specified.
4. In this datasheet, all the test methods of indications are based on corporate standards.
5. Only typical models listed, other models may be different, please contact our technical person for more details.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
page 3/4