NICHIA NDU1113E

[ UTZ-SC0084_0 ]
Ultra Violet Laser Diode
NDU1113E
Engineering Sample
Features
Outline Dimension
• Wavelength: 375nm
• Optical Output Power: 20mW
• Can Type: φ 5.6
Unit (mm)
(90°
)
(Tc=25°C)
Z+
Φ 4.2±0.2
Φ 3.55±0.1
Emitting Point
Reference Plane
6.5±1.0
* Operating Temperature must be controlled within 20 ~ 30 °C range.
0.25±0.03
mW
V
V
°C
°C
Glass Thickness
Po
Vr (LD)
Vr (PD)
Tstg
Tc
1.0±0.1
1.3±0.08
Optical Output Power
LD Reverse Voltage
PD Reverse Voltage
Storage Temperature
Operating Case Temperature
Unit
0.4±0.1
Symbol
Emitting Point
(0.4)
1.2±0.1
2.3±0.2
Item
Absolute Maximum
Ratings
30
5
20
-40 ~ 85
20 ~ 30 *
0
+ .03
0
-
(
1.
6)
Φ
Absolute Maximum Ratings
Φ
5.
6
3×Φ 0.45±0.1
Initial Electrical/Optical Characteristics
(Tc=25°C)
Item
Condition
Symbol
Min
Typ.
Max
Unit
Optical Output Power
CW
Po
-
-
20
mW
Peak Wavelength
Po=20mW
λp
370
375
380
nm
CW
Ith
-
45
60
mA
Operating Current
Po=20mW
Iop
-
60
85
mA
Slope Efficiency
CW
η
0.9
1.2
1.6
W/A
Operating Voltage
Po=20mW
Vop
4.5
5.2
6.5
V
FWHM Beam
Divergence
Po=20mW
θ//
5
8.5
13
deg.
θ⊥
18
22
26
deg.
∆θ//
-
-
±3.0
deg.
∆θ⊥
-
-
±5.0
deg.
Angle
Po=20mW
Position
-
∆X, Y, Z
-
-
±80
µm
Po=20mW
Im
-
0.2
-
mA
Monitor Current**
X+
1
2
Φ 2.0±0.2
Y+
Threshold Current
Emission
Point
Accuracy
3
( ) are reference figures
Pin Connection
2
1
PD
LD
1. LD Anode
2. PD Anode
3. Common
3
This internal photodiode are solely
Nichia's internal evaluation purpose
only, and Nichia gives no warranty to
Monitor Current.
** Monitor Current is short time power reference purpose only. Not guaranteed for accuracy.
All figures in this specification are measured by Nichia's method and may contain measurement deviations.
This model is Engineering Sample for evaluation or design purpose only. Life time is not guaranteed.
The above specifications are for reference purpose only and subjected to change without prior notice.
NICHIA CORPORATION
http://www.nichia.co.jp
HEAD OFFICE
P.O.BOX 6 ANAN, TOKUSHIMA-KEN 774-8601, JAPAN
PHONE: +81-884-22-2311
FAX: +81-884-21-0148
CONTACT
TOKYO SALES DEPARTMENT OPTOELECTRONICS PRODUCTS DIV.
13F TAMACHI CENTER BUILDING, 34-7, SHIBA 5-CHOME, MINATO-KU,
TOKYO 108-0014, JAPAN
PHONE: +81-3-3456-3108
FAX: +81-3-5440-7330
-1-
[ UTZ-SC0084_0 ]
Typical Characteristics
-2-
[ UTZ-SC0084_0 ]
Cautions
(1) Safety of Laser light
Laser beam are extremely dangerous to human eyes. Never look at laser
beam directly and/or through optical lens. When handling the LDs, wear
appropriate safety glasses to prevent laser light, even any reflections from
entering to the eye. Focused laser beam through optical instruments will
increase the chance of eye hazard.
Nichia LDs are classified in Class 3B of IEC60825-1 and 21 CFR Part
1040.10 Safety Standards. It is absolutely necessary to take overall safety
measures against User's modules, equipment and systems into which Nichia
LDs are incorporated and/or integrated.
(2) Operating method
The LD shall change its forward voltage requirement and optical output power according to temperature change. Also,
the LD will require more operation current to maintain same output power as it degrades. In order to maintain output
power, use of APC (Automatic Power Control) is recommended, which use monitor feedback to adjust the operation
current.
Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current
level specified herein above as absolute max rating. Also, employ appropriate countermeasures to reduce chattering
and/or overshooting in the Circuit.
(3) Static Electricity
Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist
strap or anti-electrostatic glove when handling the Product.
(4) Absolute Maximum Rating
Active layer of LDs shall have high current density and generate high electric field during its operation. In order to
prevent excessive damage, the LD must be operated strictly below Absolute Max Rating.
(5) Others
Nichia LDs described in this brochure are intended to be used for ordinary electronic equipment (such as office
equipment, communications equipment, measurement instruments and household appliances). Consult Nichia’s sales
staff in advance for information on the applications in which exceptional quality and reliability are required,
particularly when the failure or malfunction of the LDs may directly jeopardize life or health (such as for airplanes,
aerospace, submersible repeaters, nuclear reactor control systems, automobiles, traffic control equipment, life support
systems and safety devices).
The Purchaser must acknowledge that any LD can be failed statically and must design its equipments fail safe design.
Prior to use of the LD, please confirm that the LD, as described in Nichia’s specifications, meets the life expectancy
needs of, and provides the features required by the Circuit and any related modules, equipment and/or systems.
Nichia prohibit Purchaser from reverse engineering, disassembling, or taking any other steps to derive the structure or
design of the LD.
The appearance and specifications of the product may be modified for improvement without notice. The formal
specifications must be exchanged and signed by both parties before large volume purchase begins.
No unauthorized transmission or reproduction of this document, either in whole or in part, is permitted.
-3-