OSRAM SFH4881

IR-Lumineszenzdiode (880 nm) im TO-46-Gehäuse
Infrared Emitter (880 nm) in TO-46 Package
Lead (Pb) Free Product - RoHS Compliant
SFH 4881
SFH 4883
SFH 4881
SFH 4883
Wesentliche Merkmale
Features
• Hergestellt im Schmelzepitaxieverfahren
• Anode galvanisch mit dem Gehäuseboden
verbunden
• Hohe Zuverlässigkeit
• Gute spektrale Anpassung an
Si-Fotoempfänger
• Hermetisch dichtes Metallgehäuse
•
•
•
•
•
Anwendungen
Applications
• Lichtschranken für Gleich- und
Wechsellichtbetrieb
• IR-Gerätefernsteuerungen
• Sensorik
• Photointerrupters
• IR remote control
• Sensor technology
Fabricated in a liquid phase epitaxy process
Anode is electrically connected to the case
High reliability
Matches all Si-Photodetectors
Hermetically sealed package
Typ
Type
Bestellnummer
Ordering Code
Strahlstärke (IF = 100 mA, tp = 20 ms)
Radiant Intensity)
Ie (mW/sr)
SFH 4881
Q62702P5302
≥ 40 (typ. 72)
SFH 4883
Q62702P5303
≥ 4 (typ. 8)
2008-02-25
1
SFH 4881, SFH 4883
Grenzwerte (TC = 25 °C)
Maximum Ratings
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
Betriebs- und Lagertemperatur
Operating and storage temperature range
Top; Tstg
– 40 … + 100
°C
Sperrspannung
Reverse voltage
VR
5
V
Durchlaßstrom
Forward current
IF
200
mA
Stoßstrom
Surge current
tp = 10 µs, D = 0.01
IFSM
2.5
A
Verlustleistung
Power dissipation
Ptot
470
mW
Wärmewiderstand
Thermal resistance
RthJA
RthJC
450
160
K/W
K/W
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
Wellenlänge der Strahlung
Wavelength of peak emission
λpeak
880
nm
Spektrale Bandbreite bei 50% von Imax
Spectral bandwidth at 50% of Imax
∆λ
80
nm
ϕ
ϕ
±5
± 35
Grad
deg.
Aktive Chipfläche
Active chip area
A
0.16
mm2
Abmessungen der aktiven Chipfläche
Dimension of the active chip area
L×B
L×W
0.4 × 0.4
mm²
Kennwerte (TA = 25 °C)
Characteristics
Abstrahlwinkel
Half angle
SFH 4881
SFH 4883
2008-02-25
2
SFH 4881, SFH 4883
Kennwerte (TA = 25 °C) (cont’d)
Characteristics
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
Schaltzeiten, Ie von 10% auf 90% und
von 90% auf 10%
Switching times, Ie from 10% to 90% and
from 90% to 10%
IF = 100 mA, RL = 50 Ω
t r , tf
500
ns
Kapazität
Capacitance
VR = 0 V, f = 1 MHz
Co
25
pF
VF
VF
VF
1.5 (≤ 1.8)
2.4 (≤ 3.0)
2.9 (≤ 3.4)
V
V
V
IR
0.01 (≤ 10)
µA
Φe
Φe
12
15
mW
mW
Durchlaβspannung
Forward voltage
IF = 100 mA, tp = 20 ms
IF = 1 A, tp = 100 µs
IF = 1.5 A, tp = 100 µs
Sperrstrom
Reverse current
VR = 5 V
Gesamtstrahlungsfluß
Total radiant flux
IF = 100 mA, tp = 20 ms
SFH 4881
SFH 4883
Strahlstärke Ie in Achsrichtung
gemessen bei einem Raumwinkel von Ω = 0.01 sr
Radiant Intensity Ie in Axial Direction
measured at a solid angle of Ω = 0.01 sr
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
SFH 4881
SFH 4883
Einheit
Unit
Strahlstärke
Radiant intensity
IF = 100 mA, tp = 20 ms
Ie min
Ie typ
40
72
4
8
mW/sr
mW/sr
Strahlstärke
Radiant intensity
IF = 1 A, tp = 100 µs
Ie typ
630
70
mW/sr
2008-02-25
3
SFH 4881, SFH 4883
Relative Spectral Emission
Ierel = f (λ)
OHR01171
100
Ι erel
Radiant Intensity
Ie/Ie (100 mA) = f (IF)
Max. Permissible Forward Current
IF = f (TA, TC)
OHR01172
10 2
Ιe
Ι e (100 mA)
%
IF
10
60
10 0
R thJC = 160 K/W
200
1
80
OHF03900
240
mA
160
120
10 -1
40
R thJA = 450 K/W
80
10 -2
20
0
750
800
850
900
950 nm 1000
10 -3
10 0
10 1
10 2
λ
Forward Current
IF = f (VF)
0
10 3 mA 10 4
ΙF
0
20
40
60
80 ˚C 100
TA , TC
Radiation Characteristics
SFH 4881, Ierel = f (ϕ)
OHR01173
10 1
ΙF
40
40˚
30˚
20˚
10˚
ϕ
A
0˚
OHR01178
1.0
50˚
10 0
0.8
60˚
0.6
10 -1
10 -2
70˚
0.4
80˚
0.2
0
90˚
10 -3
0
1
2
3
4
5
100˚
VF
Permissible Pulse Handling
Capability IF = f (τ), TC = 25 °C,
RthJC = 160 K/W,duty cycle D =
parameter
2.6
IF A
0.8
0.6
0.4
40˚
30˚
20˚
tP
D = TP
IF
T
1.6
1.4
1.2
1.0
0.8
0.6
10˚
ϕ
20˚
40˚
60˚
80˚
100˚
120˚
0˚
OHR01186
1.0
50˚
0.8
2.0
1.8
0˚
Radiation Characteristics
SFH 4883, Ierel = f (ϕ)
OHF03756
t
1.0
D=
60˚
0.005
0.01
0.02
0.05
0.1
0.2
0.3
0.5
1
0.6
70˚
0.4
80˚
0.2
0
90˚
0.4
0.2
0 -5
10 10-4 10-3 10-2 10-1 100 101 s 102
100˚
1.0
0.8
0.6
tp
2008-02-25
4
0.4
0˚
20˚
40˚
60˚
80˚
100˚
120˚
SFH 4881, SFH 4883
Maßzeichnungen
Package Outlines
SFH 4881
ø4.8 (0.189)
ø4.6 (0.181)
1
ø5.6 (0.220)
ø5.3 (0.209)
2.54 (0.100)
spacing
ø0.43 (0.017)
6.2 (0.244)
5.4 (0.213)
Chip position (1.1 (0.043))
2
0.9
)
43
0.35 (0.014) max.
20 (0.787)
18 (0.709)
1.1
5.2 (0.205)
4.9 (0.193)
.0
(0
0.9
1.1
(0
.04
.03 3)
5)
(0
5)
3
0.0
(
GEMY6049
5)
0.35 (0.014) max.
3.8 (0.150)
3.5 (0.138)
2.54 (0.100)
spacing
1.1
0.9
3)
.03
(0
2
20 (0.787)
18 (0.709)
.04
(0
0.9
1
1.1
ø0.43 (0.017)
Chip position (1.1 (0.043))
(0
(0 .043
.03 )
5)
ø4.8 (0.189)
ø4.6 (0.181)
SFH 4883
ø5.6 (0.220)
ø5.3 (0.209)
GEMY6050
Maße in mm (inch) / Dimensions in mm (inch).
Package
TO-46-Metallgehäuse, Glaslinse, hermetisch dicht, Anschlüsse im
2.54-mm-Raster (1/10’’)
TO-46-metal-package, glass lens, hermetically sealed, solder tabs lead
spacing 2.54 mm (1/10’’)
Anschlussbelegung
Pin configuration
Anschluss 2: Kathode
Pin 2 : cathode
Gehäuse
2008-02-25
5
SFH 4881, SFH 4883
Lötbedingungen
Soldering Conditions
Wellenlöten (TTW)
TTW Soldering
(nach CECC 00802)
(acc. to CECC 00802)
OHLY0598
300
C
T
10 s
250
Normalkurve
standard curve
235 C ... 260 C
Grenzkurven
limit curves
2. Welle
2. wave
200
1. Welle
1. wave
150
ca 200 K/s
2 K/s
5 K/s
100 C ... 130 C
100
2 K/s
50
Zwangskühlung
forced cooling
0
0
50
100
150
200
s
250
t
Published by
OSRAM Opto Semiconductors GmbH
Wernerwerkstrasse 2, D-93049 Regensburg
www.osram-os.com
© All Rights Reserved.
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components 1 , may only be used in life-support devices or systems 2 with the express written approval of OSRAM OS.
1
A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2
Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.
2008-02-25
6