RFSOLUTIONS 119S2-433A

119, 129
10209
KEELOQ REMOTE CONTROL SYSTEMS, 230Vac
•
•
•
1 – 2 Channel Remote Control Systems
230Vac Supply
AM / FM / FMNB Remote Receiver Decoder
AM Range upto 100m
FM Range upto 200m
FMNB Range upto 1000m
•
•
•
•
•
•
•
•
•
DS119-5
High Security
Protocol
‘Easy Learn’ Tx Encoder Feature
Description
A Range of ‘ready to operate’ remote control systems
supplied as either AM or FM and contain a
transmitter and receiver decoder pair.
Installation requires connections to power supply
(230Vac Live and Neutral) and the output relay screw
terminals. The output relays are activated by the key
press on the transmitter encoder.
The system utilises the Microchip Keeloq protocol,
ensuring high security and reliability.
Easy Installation Via Screw Terminals.
Up to 50 Transmitters per System
315 / 433 / 868 / 915 MHz Available
2 Relays Rated 12A pk at 230Vac
Momentary or Latching Outputs
The decoder has the capacity to learn up to 50
unique transmitters. These are memorised even if the
power is removed.
The decoder is supplied in an IP65 rated enclosure
with Cable Gland and wall mounting lugs supplied
IP65 Rated Enclosure (Wall Mounting Lugs
Supplied)
Requires No Radio Licence
June ‘06
©2006 REG No 277 4001, ENGLAND.
Page 1
119, 129
10209
KEELOQ REMOTE CONTROL SYSTEMS, 230Vac
AM Remote Controls
Part Number
Description
Transmitter Type
Freq
(MHz)
Range**
(Metres)
119S1-433A
AM RC System 1 ch 230Vac
Pocket Keyfob
433.92
100
119S2-433A
AM RC System 2 ch 230Vac
Pocket Keyfob
433.92
100
Additional AM Transmitter Keyfobs
Part Number
Description
Freq
(MHz)
Range**
(Metres)
110C1-433A
Transmitter Keyfob, 1 switch
433.92
100
110C2-433A
Transmitter Keyfob, 2 switch
433.92
100
FM Remote Controls
Part Number
Description
Transmitter Type
Freq
(MHz)
Range**
(Metres)
129S1-433F
FM RC System 1 ch 230Vac
Pocket Keyfob
433.92
150
129S2-433F
FM RC System 2 ch 230Vac
Pocket Keyfob
433.92
150
10209S1-433F
FM RC System 1 ch 230Vac
Handheld
433.92
200
10209S2-433F
FM RC System 2 ch 230Vac
Handheld
433.92
200
10209S1-525N
FM NB RC System 1 ch 230Vac
Handheld
434.525
1000
10209S2-525N
FM NB RC System 2 ch 230Vac
Handheld
434.525
1000
Additional FM Transmitter Keyfobs
Part Number
Description
Freq
(MHz)
Range**
(Metres)
120T1-433F
Transmitter Keyfob 1 switch
433.92
150
120T2-433F
Transmitter Keyfob 2 switch
433.92
150
102C1-433F
FM Transmitter encoder 1 switch
433.92
200
102C2-433F
FM Transmitter encoder 2 switch
433.92
200
102C1-525N
FM Transmitter encoder 1 switch
434.525
1000
102C2-525N
FM Transmitter encoder 2 switch
434.525
1000
** Range stated is optimum, direct line of sight. In worst conditions this can be reduced by over 50%
DS119-5
June ‘06
©2006 REG No 277 4001, ENGLAND.
Page 2
119, 129
10209
KEELOQ REMOTE CONTROL SYSTEMS, 230Vac
Data Outputs
Each of the transmitter switches maps directly to the relay outputs. (SW1 to RLY1, SW2 to RLY2)
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and
Normally Closed (NC).
NC
COM
NO
NC
COM
NO
Relay Connections when
Transmitter NOT Operating
Relay Connections when
Transmitter OPERATING
The jumper links ( LK1, LK2 ) configure the outputs to be momentary or latching.
LK1
LK2
O/P 1
O/P2
Open
Open
Mom
Mom
Open
Connected
Mom
Latch
Connected
Open
Latch
Mom
Connected
Connected
Latch
Latch
Note : In momentary mode the relay will operate for as long as the transmitter switch is held on.
Learning a new Transmitter Encoder
To enter and activate the learn mode the following sequence must be performed.
1. Power the receiver unit up and wait 10secs for the unit to enter ‘normal operation’ mode.
2. Switch the receiver unit OFF and then ON again in ~1sec intervals four times finally leaving the unit
powered up.
3. After 5secs until a ‘beep’ sound is heard.
4. The unit is now in ‘learn’ Mode.
5. Briefly press a button on the transmitter, the receiver unit will ‘beep’ twice.
6. Briefly Press the transmitter button again, he receiver unit will ‘beep’ three times.
7. Wait 10sec for the unit to return to ‘normal operation’ mode.
8. The transmitter is now ‘learnt’ to the receiver unit and will operate the output relays.
Erasing Transmitter Encoders form Memory
To enter and activate the erase mode the following sequence must be performed.
1. Power the receiver unit up and wait 10secs for the unit to enter ‘normal operation’ mode.
2. Switch the unit off and then on again in ~1sec intervals six times finally leaving the unit powered up.
3. Wait 5secs until a ‘ticking’ sound is heard for a period of 10secs by the operation and release of one of the
relays.
4. Wait 10secs for the receiver unit to return to ‘normal’ mode
5. The unit has now erased all encoder data.
Note
During Learn and Erase the relays should not be connected to equipment that will be harmed by rapid
changes of the relay polarisation.
DS119-5
June ‘06
©2006 REG No 277 4001, ENGLAND.
Page 3
119, 129
10209
KEELOQ REMOTE CONTROL SYSTEMS, 230Vac
Technical Specifications
‘110’ & ‘120’ Transmitter Keyfob
Battery Type
GP23AE (supplied)
Electrical Characteristics
Min
Typical
Max
Supply Voltage
Supply Current : Quiescent
Supply Current : Transmitting
Operating frequency
8.5
9
0
8
433.92
16
Min
8
11
432.90
434.450
-
Typical
9
14
433.92
434.525
Max
12
21
434.10
434.575
10
Units
V
mA
mA
MHz
‘102’ Transmitter Encoder
Battery Type
PP3 (supplied)
Dimensions
110mm x 65mm x 24mm
Electrical Characteristics
Supply Voltage
Supply Current
Frequency:
Wideband
Narrowband
RF Output Power (ERP) @ 433 MHz
Units
V
mA
MHz
MHz
mW
‘009’ Receiver Decoder
Dimensions
110mm (not including antenna) x 85mm x 35mm
Operating Temperature: 0 to +55o Celsius.
Storage Temperature: -10 to +70o Celsius.
Electrical Characteristics
Min
Typical
Max
Units
VAC
Supply Voltage
230
Supply Current :
Quiescent
19
mA
all relays operating
260
Relay Rating at 230Vac*
5
12
A
Time delay from Tx on Switch to Rx Relay operation
100
mS
Time delay from Tx sw relax to Rx Relay release
300
MS
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
RS232 Serial Data Output
The ‘009’ receiver decoder board can have the capability of an RS232 serial data output via Connector J6.
This requires the addition of an RS232 driver chip (MAX232) in position U5 and associated capacitors
C5,6,7,8 (100nF). The data output connections from the PCB should be made to Pin 2 and the ground
connection made to Pin 5 of a 9 way ‘D’ type connector. The COM port settings should be:Bits per Second:
Data Bits:
Parity:
Stop Bits:
Flow Control:
9600
8
None
1
None
The data stream contains the encoder serial number, button code and low battery status bit.
For more information on using the serial data output or for general enquiries, please call:
RF Solutions Ltd.
Unit 21, Cliffe Industrial Estate,
Lewes, E. Sussex, BN8 6JL, England
Tel +44 (0)1273 898 000
Fax +44 (0)1273 480 661
Information contained in this document is believed to be accurate , however no representation or warranty is given and no liability is assumed by R.F. Solutions Ltd. with respect to the accuracy of
such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DS119-5
June ‘06
©2006 REG No 277 4001, ENGLAND.
Page 4
119, 129
10209
KEELOQ REMOTE CONTROL SYSTEMS, 230Vac
Email: [email protected]
DS119-5
June ‘06
http://www.rfsolutions.co.uk
©2006 REG No 277 4001, ENGLAND.
Page 5