RECTRON RBU406M

RBU401M
THRU
RBU407M
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 4.0 Amperes
FEATURES
* Ideal for printed circuit board
* Surge overload rating: 130 amperes peak
* Mounting position: Any
RBU
MECHANICAL DATA
.880 (22.3)
.860 (21.8)
* UL listed the recognized component directory,file #E252754
* Epoxy: Device has UL flammability classification 94V-O
.140 (3.56)
.130 (3.30)
.740 (18.8)
.720 (18.3)
.512 (13.0)
.080 (2.03)
.060 (1.52)
.160 (4.1)
.140 (3.5)
.085 (2.16)
.075 (1.90)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
.210 (5.33)
.190 (4.83)
For capacitive load, derate current by 20%.
.080 (2.03)
.065 (1.65)
.050 (1.27)
.040 (1.02)
.710 (18.0)
.690 (17.5)
.100 (2.54)
.085 (2.16)
.022 (0.56)
.018 (0.46)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
RATINGS
SYMBOL
RBU401M RBU402M RBU403M RBU404M RBU405M RBU406M RBU407M
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T A = 50 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Junction Capacitance (Note 3)
Typical Thermal Resistance (Note 1)
Operating and Storage Temperature Range
Volts
IO
4.0
Amps
I FSM
130
Amps
CJ
40
R θ JC
4.2
R θ JA
22
T J, T STG
-55 to + 150
pF
0
C/ W
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 4.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25o C
@T A = 125o C
SYMBOL
RBU401M RBU402M RBU403M RBU404M RBU405M RBU406M RBU407M
UNITS
VF
1.1
Volts
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
3. Measured at 1MHz and applied reverse voltage of 4.0 voltage.
4. Equivalent to Vishay's GBU4 Series.
5.0
500
uAmps
2013-04
REV: B
4.0
Heatsink Mounting, TC
1.6x1.6x0.06" Thk
(4.0x4.0x.15cm) AL.Plate
3.0
2.0
P.C.B. Mounted,TA
0.47x0.47" (12x12mm) Copper Pads
0.375" (9.5mm) Lead Length
60Hz Resistive or Inductive Load
1.0
0
0
50
100
150
INSTANTANEOUS FORWARD CURRENT, (A)
AVERAGE FORWARD OUTPUT CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( RBU401M THRU RBU407M )
40
10
4.0
1.0
0.4
0.1
0
O
FIG.1 DERATING CURVE OUTPUT
RECTIFIED CURRENT
1000
100
TA = 100 OC
10
TA = 25 OC
1.0
0.1
50~400V
600~1000V
0
20
40
60
80
100
120
140
240
100
10
REVERSE VOLTAGE, (V)
FIG.5 TYPICAL JUNCTION CAPACITANCE
PER LEG
100
TRANSIENT THERMAL IMPEDANCE, (OC/W)
JUNCTION CAPACITANCE, (pF)
1000
1
1.5
2.0
2.5
3.0
3.5
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
8.3mS Single Half Sine-Wave
JEDEC Method
160
120
80
40
0
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.3 TYPICAL REVERSE CHARACTERISTICS
0.1
1.0
200
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
10
0.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (mA)
TEMPERATURE, ( C)
T A = 25 OC
Pulse Width = 300mS
1% Duty Cycle
FIG.4 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
100
10
1
0.1
0.01
0.1
1
10
t, HEATING TIME (sec.)
FIG.6 TYPICAL TRANSIENT THERMA
IMPEDANCE
100
Marking Description
Rectron Logo
RBU40XM
Part No.
Voltage-code
UL Logo
Year – code
(Y:Last digit of year&
A:2010, B:2011……)
VYWW
Week – code:
(WW:01~52)
1-------50V
2-------100V
3-------200V
4-------400V
5-------600V
6-------800V
7-------1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE
PACKING CODE
EA PER BOX
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
RBU
-C
1,000
490*135*110
510*293*131
EA PER CARTON
WEIGHT(Kg)
2,000
13.62
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.