RECTRON BR104 -B-D-A01 SEMICONDUCTOR TECHNICAL SPECIFICATION SINGLE-PHASE SILICON BRIDGE RECTIFIER VOLTAGE RANGE 400 Volts CURRENT 10 Amperes FEATURES * Surge overload rating: 200 amperes peak * Low forward voltage drop BR-10 MECHANICAL DATA * * * * * * UL listed the recognized component directory, file #E94233 Epoxy: Device has UL flammability classification 94V-O Lead: Mil-STD-202E method 208C guaranteed Mounting position: Any Weight: 7.86 grams Mounting: Hole thru for # 6 screw .296 (7.5) .255 (6.5) .042 (1.1) .039 (1.0) TYP. .75 MIN. (19.1) DIA. .770 (19.6) .730 (18.5) HOLE FOR NO. 6 SCREW AC MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS o Ratings at 25 C ambient temperature unless otherwise specified. AC Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. .520 (13.2) .480 (12.2) .770 (19.6) .730 (18.5) .520 (13.2) .480 (12.2) Dimensions in inches and (millimeters) MAXIMUM RATINGS (At T A = 25oC unless otherwise noted) SYMBOL RATINGS Maximum Recurrent Peak Reverse Voltage VRRM Maximum RMS Voltage VRMS Maximum DC Blocking Voltage Maximum Average Forward Tc = 50 o C o Rectified Output Current at: Tc = 100 C o T A = 50 C BR104-B-D-A01 UNITS 400 280 Volts VDC 400 10.0 Volts IO 6.0 Amps Volts 6.0 Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) I FSM 200 Typical Thermal Resistance R θJ A 28 0 C/W Typical Thermal Resistance R θJC 6.5 0 C/W TJ -55 to + 150 0 C T STG -55 to + 150 0 C Operating Temperature Range Storage Temperature Range Amps ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted) CHARACTERISTICS SYMBOL VF Maximum Forward Voltage Drop per element at 5.0A DC o Maximum Reverse Current at Rated @T A = 25 C DC Blocking Voltage per element @T C = 100 C Note: “Fully ROHS compliant”, “100% Sn plating (Pb-free)”. o IR BR104-B-D-A01 UNITS 1.1 Volts 5.0 uAmps 0.2 m Amps 2005-3 REV:A RATING AND CHARACTERISTIC CURVES ( BR104-B-D-A01 ) FIG. 2 - TYPICAL FORWARD CURRENT DERATING CURVE FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD 250 AVERAGE FORWARD CURRENT, (A) PEAK FORWARD SURGE CURRENT, (A) SURGE CURRENT 8.3ms Single Half Sine-Wave (JEDEC Method) 200 150 100 50 0 1 2 10 8 SE 6 AM BI 4 0 FIG. 3- TYPICAL INSTANTANEOUS FORWARD INSTANTANEOUS REVERSE CURRENT, (uA) INSTANTANEOUS FORWARD CURRENT, (A) TJ = 25 Pulse Width = 300us 1% Duty Cycle 10 1.0 .1 .01 .6 .7 .8 .9 1.0 1.1 1.2 1.3 INSTANTANEOUS FORWARD VOLTAGE, (V) T 50 100 CASE TEMPERATURE, ( 150 ) FIG. 4 - TYPICAL REVERSE CHARACTERISTICS CHARACTERISTICS 100 EN 60 Hz RESISTIVE OR INDUCTIVE LOAD 2 0 4 6 8 10 20 40 60 80100 NUMBER OF CYCLES AT 60Hz CA 10 1.0 TJ = 25 .1 .01 0 20 40 60 80 100 120 140 PERCENT OF RATED PEAK REVERSE VOLTAGE, ( % ) RECTRON LEAD FORMING SPECIFICATIONS Unit: mm BR-10 19.1 7.4 C 19 ± 0.5 B 5.0 A 1.0 3.5 ± 0.5 12.0 ± 0.5 Marking on the body Rectron Logo UL Logo Year – code (Y:Last digit of year & A:2010,B:2011…) BR104 Part No. VYWW Week – code (WW:01~52) Voltage-code 05-------50V 1-------100V 2-------200V 4-------400V 6-------600V 8-------800V 10-----1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS BULK PACK PACKAGE PACKING CODE BR-10 -B EA PER BOX 200 INNER BOX SIZE (mm) 236*236*50 CARTON SIZE (mm) 497*251*282 EA PER CARTON 2,000 GROSS WEIGHT(Kg) 12.24 DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.