RECTRON BR104-B-D-A01

RECTRON
BR104
-B-D-A01
SEMICONDUCTOR
TECHNICAL SPECIFICATION
SINGLE-PHASE SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 400 Volts CURRENT 10 Amperes
FEATURES
* Surge overload rating: 200 amperes peak
* Low forward voltage drop
BR-10
MECHANICAL DATA
*
*
*
*
*
*
UL listed the recognized component directory, file #E94233
Epoxy: Device has UL flammability classification 94V-O
Lead: Mil-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 7.86 grams
Mounting: Hole thru for # 6 screw
.296 (7.5)
.255 (6.5)
.042 (1.1)
.039 (1.0)
TYP.
.75
MIN.
(19.1)
DIA.
.770 (19.6)
.730 (18.5)
HOLE FOR
NO. 6 SCREW
AC
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
AC
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.520 (13.2)
.480 (12.2)
.770 (19.6)
.730 (18.5)
.520 (13.2)
.480 (12.2)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25oC unless otherwise noted)
SYMBOL
RATINGS
Maximum Recurrent Peak Reverse Voltage
VRRM
Maximum RMS Voltage
VRMS
Maximum DC Blocking Voltage
Maximum Average Forward Tc = 50 o C
o
Rectified Output Current at: Tc = 100 C
o
T A = 50 C
BR104-B-D-A01
UNITS
400
280
Volts
VDC
400
10.0
Volts
IO
6.0
Amps
Volts
6.0
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
I FSM
200
Typical Thermal Resistance
R θJ A
28
0
C/W
Typical Thermal Resistance
R θJC
6.5
0
C/W
TJ
-55 to + 150
0
C
T STG
-55 to + 150
0
C
Operating Temperature Range
Storage Temperature Range
Amps
ELECTRICAL CHARACTERISTICS (At TA = 25oC unless otherwise noted)
CHARACTERISTICS
SYMBOL
VF
Maximum Forward Voltage Drop per element at 5.0A DC
o
Maximum Reverse Current at Rated
@T A = 25 C
DC Blocking Voltage per element
@T C = 100 C
Note: “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
o
IR
BR104-B-D-A01
UNITS
1.1
Volts
5.0
uAmps
0.2
m Amps
2005-3
REV:A
RATING AND CHARACTERISTIC CURVES ( BR104-B-D-A01 )
FIG. 2 - TYPICAL FORWARD CURRENT
DERATING CURVE
FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD
250
AVERAGE FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
SURGE CURRENT
8.3ms Single Half Sine-Wave
(JEDEC Method)
200
150
100
50
0
1
2
10
8
SE
6
AM
BI
4
0
FIG. 3- TYPICAL INSTANTANEOUS FORWARD
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
TJ = 25
Pulse Width = 300us
1% Duty Cycle
10
1.0
.1
.01
.6
.7
.8
.9
1.0
1.1
1.2
1.3
INSTANTANEOUS FORWARD VOLTAGE, (V)
T
50
100
CASE TEMPERATURE, (
150
)
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
CHARACTERISTICS
100
EN
60 Hz RESISTIVE OR
INDUCTIVE LOAD
2
0
4 6 8 10 20
40 60 80100
NUMBER OF CYCLES AT 60Hz
CA
10
1.0
TJ = 25
.1
.01
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE, ( % )
RECTRON
LEAD FORMING SPECIFICATIONS
Unit: mm
BR-10
19.1
7.4
C 19 ± 0.5
B
5.0
A
1.0
3.5 ± 0.5
12.0 ± 0.5
Marking on the body
Rectron Logo
UL Logo
Year – code
(Y:Last digit of year &
A:2010,B:2011…)
BR104
Part No.
VYWW
Week – code
(WW:01~52)
Voltage-code
05-------50V
1-------100V
2-------200V
4-------400V
6-------600V
8-------800V
10-----1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
PACKING CODE
BR-10
-B
EA PER BOX
200
INNER BOX SIZE
(mm)
236*236*50
CARTON SIZE
(mm)
497*251*282
EA PER CARTON
2,000
GROSS
WEIGHT(Kg)
12.24
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.