ROITHNER LD635-C220

LD635-C220
TECHNICAL DATA
Red Laser Diode
Features
•
•
•
•
Lasing Mode Structure: multi mode
Peak Wavelength : typ. 633 nm
Optical Ouput Power: 220 mW, CW
Package: 9.0 mm, flat window
Electrical Connection
Pin Configuration
PIN
1
2
3
Bottom View
Function
LD Cathode
LD Anode
(PD on request)
Absolute Maximum Ratings (TC=15°C)
Item
CW Output Power
LD Reverse Voltage
LD Forward Current
Operating Case Temperature
Storage Temperature
Symbol
PO
Vr
Iop
TC
Tstg
Value
220
0
500
5 … +20
-40 … +85
Unit
mW
V
mA
°C
°C
Specifications (TC=15°C)
Item
Optical Specifications
CW Output Power
Center Wavelength
Spectral Width (FWHM)
Wavelength Temperature Coefficient
FWHM Beam Divergence
Emitting Area Width
Electrical Specifications
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Symbol
Min.
Typ.
Max.
Unit
PO
λC
Δλ
Δλ / ΔT
Θ║
Θ┴
WE
631
-
220
633
1
0.2
3
38
50
635
-
mW
nm
nm
nm/K
deg
deg
µm
Ith
Iop
η
Vop
-
160
400
0.92
2.3
-
mA
mA
mW/mA
V
The above specifications are for reference purpose only and subjected to change without prior notice.
13.09.2011
LD635-C220
1 of 2
Package Dimensons
5.6 mm Package (Unit:mm)
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the
eye or skin directly to any laser light and/or through optical lens. When
handling the LDs, wear appropriate safety glasses to prevent laser
light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye
hazard.
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades. In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
13.09.2011
LD635-C220
2 of 2