ROITHNER RLT650-500-T

RLT650-500-T
TECHNICAL DATA
High Power Visible Laser Diode
Features
•
•
•
•
Lasing Mode Structure: multi mode
Peak Wavelength : typ. 650 nm
Optical Ouput Power: 500 mW
Package: TO-3, without Photodiode
Electrical Connection
Pin Configuration
PIN
1
2
Bottom View
Function
LD Cathode
LD Anode (isolated from case)
Absolute Maximum Ratings (TC=20°C)
Item
CW Output Power
Operating Case Temperature
Storage Temperature
Symbol
PO
TC
Tstg
Value
500
-10 … +25
-40 … +85
Unit
mW
°C
°C
Specifications (TC=20°C)
Item
Optical Specifications
CW Output Power
Center Wavelength
Spectral Width (FWHM)
Wavelength Temperature Coefficient
FWHM Beam Divergence
Emitting Aperature
Polarization
Lifetime
Electrical Specifications
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Series Resistance
Symbol
Min.
Typ.
Max.
Unit
PO
λC
Δλ
∂λ / ∂T
θ║
θ┴
WxH
645
-
660
2.5
10
40
mW
nm
nm
nm/°C
deg
deg
µm
5000
500
650
1
0.25
150 x 1
TE
-
-
hour
0.85
-
850
1370
0.90
2.1
-
1000
1500
2.3
-
mA
mA
W/A
V
Ω
Ith
Iop
η
Uop
Rd
The above specifications are for reference purpose only and subjected to change without prior notice.
25.08.2011
RLT650-500-T
1 of 3
Package Dimensons
TO-3 Package (Unit:mm)
25.08.2011
RLT650-500-T
2 of 3
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the
eye or skin directly to any laser light and/or through optical lens. When
handling the LDs, wear appropriate safety glasses to prevent laser
light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye
hazard.
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades. In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
25.08.2011
RLT650-500-T
3 of 3