ROITHNER S6705MG

S6705MG
TECHNICAL DATA
Infrared Laser Diode
Features
•
•
•
•
Lasing Mode Structure: single mode
Peak Wavelength : typ. 670 nm
Optical Ouput Power: 5 mW
Package: 5.6 mm
Electrical Connection
Pin Configuration
Bottom View
n-type
PIN
1
2
3
Function
LD Cathode
LD Anode, PD Cathode
PD Anode
Absolute Maximum Ratings (TC=20°C)
Item
CW Output Power
LD Reverse Voltage
PD Reverse Voltage
Operating Case Temperature
Storage Temperature
Symbol
PO
Vr
VrPD
TC
Tstg
Value
7
2
30
-10 … +60
-15 … +85
Unit
mW
V
V
°C
°C
Specifications (TC=20°C)
Item
Optical Specifications
CW Output Power
Center Wavelength
FWHM Beam Divergence
Electrical Specifications
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Monitor Current
Symbol
Min.
Typ.
Max.
Unit
PO
λC
θ║
θ┴
660
7.5
25
5
670
9
32
678
11
35
mW
nm
deg
deg
Ith
Iop
η
Uop
Im
0.4
0.1
24
34
0.5
2.2
0.2
35
45
2.6
0.5
mA
mA
mW/mA
V
mA
The above specifications are for reference purpose only and subjected to change without prior notice.
23.09.2010
S6705MG
1 of 5
Package Dimensons
5.6 mm Package (Unit:mm)
Typical Performance Curves
Optical Ouput Power vs. Forward Current
23.09.2010
S6705MG
2 of 5
Forward Voltage vs. Forward Current
Peak Wavelength vs. Case Temperature
Far-Field Pattern
23.09.2010
S6705MG
3 of 5
Monitor Current vs. Optical Output Power
Slope Efficiency vs. Case Temperature
Threshold Current vs. Case Temerature
23.09.2010
S6705MG
4 of 5
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the
eye or skin directly to any laser light and/or through optical lens. When
handling the LDs, wear appropriate safety glasses to prevent laser
light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye
hazard.
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades. In order to maintain output power, use of APC (Automatic Power
Control) is recommended. Which use monitor feedback to adjust the operation current.
• Confirm that electrical spike current generated by swithing on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
23.09.2010
S6705MG
5 of 5