TECHNICAL DATA
High Power Infrared Laser Diode
Features
•
•
•
•
Lasing Mode Structure: multi mode
Peak Wavelength : typ. 1050 nm
Optical Ouput Power: 500 mW
Package: 9 mm
Electrical Connection
Pin Configuration
Bottom View
n-type
PIN
1
2
3
Function
LD Cathode
LD Anode, PD Cathode
PD Anode
Absolute Maximum Ratings (TC=25°C)
Item
CW Output Power
LD Reverse Voltage
PD Reverse Voltage
Operating Case Temperature
Storage Temperature
Symbol
PO
VR(LD)
VR(PD)
TC
Tstg
Value
550
1.5
10
-20 … +35
-40 … +70
Unit
mW
V
V
°C
°C
Specifications (TC=25°C)
Item
Optical Specification
CW Output Power
Peak Wavelength
Spectral Width (FWHM)
FWHM Beam Divergence
Emitting Aperature
Electrical Specification
Threshold Current
Operating Current
Operating Voltage
Monitor Current
Operating Voltage
Symbol
Min.
Typ.
Max.
Unit
PO
λP
Δλ
θ║
θ┴
WxH
1.6
-
500
1050
1.7
10
30
100 x 1
1.8
-
mW
nm
nm
deg
deg
µm
Ith
Iop
Uop
Im
Uop
200
860
100
-
280
890
1.7
500
1.9
350
910
1.8
1500
-
mA
A
V
µA
V
The above specifications are for reference purpose only and subjected to change without prior notice.
25.02.2011
RLT1050M-500G
1 of 3
Package Dimensons
9 mm Package (Unit:mm)
25.02.2011
RLT1050M-500G
2 of 3
Safety of Laser light
•
•
Laser Light can damage the human eyes and skin. Do not expose the
eye or skin directly to any laser light and/or through optical lens. When
handling the LDs, wear appropriate safety glasses to prevent laser
light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye
hazard.
Warning: Laser diode is emitting invisible light
Cautions
1. Operating methode
• This LD shall change its forward voltage requirement and optical ouput power according to
temperature change. Also, the LD will require more operation current to maintain same ouput
power as it degrades.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handeling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated striclty below
absolute maximum rating.
25.02.2011
RLT1050M-500G