ROITHNER RLT1060-150G

RLT1060-150G
TECHNICAL DATA
High Power Infrared Laser Diode
High power, single mode laser diode, featuring high reliability and long lifetime. Suitable for many
applications including medical laser therapy and defense
Features
•
•
•
•
Lasing Mode Structure: single mode
Peak Wavelength : typ. 1064 nm
Optical Output Power: 150mW
Package: TO 9 mm
Electrical Connection
Pin Configuration
Bottom View
n-type
PIN
1
2
3
Function
LD Anode
LD Cathode, PD Cathode
PD Anode
Absolute Maximum Ratings (TC=25°C)
Item
CW Output Power
Operating Case Temperature
Storage Temperature
Symbol
PO
TC
Tstg
Value
150
-20 … +50
-40 … +80
Unit
mW
°C
°C
Specifications (TC=25°C)
Item
Optical Specification
CW Output Power
Kink Power
Peak Wavelength
Spectral Width (FWHM)
Far Field (FWHM)
Emitting Aperature
Chip Cavity Length
Lifetime
Electrical Specification
Threshold Current
Operating Current
Slope Efficiency
Operating Voltage
Photodiode Current
Symbol
Min.
Typ.
Max.
Unit
PO
PK
λP
Δλ
θ║
θ┴
WxH
-
-
100000
150
180
1064
0.5
8
28
5x1
1.5
-
-
mW
mW
nm
nm
deg
deg
µm
mm
h
0.8
0.5
25
220
0.9
1.6
0.7
40
250
2.0
0.9
mA
mA
W/A
V
mA
Ith
Iop
η
Uop
IPD
1059
-
1069
2.0
10
30
The above specifications are for reference purpose only and subjected to change without prior notice.
15.07.2013
RLT1060-150G
1 of 3
Package Dimensions
9 mm Package (Unit:mm)
15.07.2013
RLT1060-150G
2 of 3
Safety of Laser light
•
Laser Light can damage the human eyes and skin. Do not expose the eye or skin directly to
any laser light and/or through optical lens. When handling the LDs, wear appropriate safety
glasses to prevent laser light, even any reflections from entering to the eye. Focused laser
beam through optical instruments will increase the chance of eye hazard.
•
WARNING: Laser Diode is emitting invisible light
Cautions
1. Operating method
• This LD shall change its forward voltage requirement and optical output power according to
temperature change. Also, the LD will require more operation current to maintain same
output power as it degrades.
• Confirm that electrical spike current generated by switching on and off does not exceed the
maximum operating current level specified herein above as absolute maximum rating. Also,
employ appropriate countermeasures to reduce chattering and/or overshooting in the circuit.
2. Static Electricity
• Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is
recommended to use a wrist trap or anti-electrostatic glove when handling the product.
3. Absolute Maximum Rating
• Active layer of LDs shall have high current density and generate high electric field during its
operation. In order to prevent excessive damage, the LD must be operated strictly below
absolute maximum rating.
15.07.2013
RLT1060-150G
3 of 3