SECELECTRONICS SS40ALUA

SS40A
CMOS Omnipolar High Sensitivity Micropower Hall Switch
Packages
Features and Benefits
3 pin SIP (suffix UA)
Functional Block Diagram
1.
2.
3.
Operation down to 2.5V
Wide operating voltage range
High sensitivity for direct reed switch replacement
applications
4.
5.
6.
7.
8.
9.
10.
Omnipolar, output switches with absolute
value of North or South pole from magnet
Temperature compensation
Open-Collector pre-driver
60V maximum withstand voltage
Reverse polarity protection
Package: TO-92S(SIP)
Application Examples
1.
2.
3.
4.
Brush-less DC Motor
Brush-less DC Fan
Revolution counting
Speed measurement
General Description:
The SS40A Omnipolar Hall effect sensor IC is fabricated from mixed signal CMOS technology. It incorporates
advanced chopper-stabilization techniques to provide accurate and stable magnetic switch points.
The circuit design provides an internally controlled clocking mechanism to cycle power to the Hall element and
analog signal processing circuits. This serves to place the high current-consuming portions of the circuit into a
“Sleep” mode. Periodically the device is “Awakened” by this internal logic and the magnetic flux from the Hall
element is evaluated against the predefined thresholds. If the flux density is above or below the B OP /B RP thresholds
then the output transistor is driven to change states accordingly. While in the “Sleep” cycle the output transistor is
latched in its previous state. The design has been optimized for service in applications requiring extended operating
lifetime in battery powered systems. An internal bandgap regulator is used to provide temperature compensated supply
voltage for internal circuits and allows a wide operating supply range.
The output transistor of the SS40A will be latched on (B OP ) in the presence of a sufficiently strong South or North
magnetic field facing the marked side of the package. The output will be latched off (B RP ) in the absence of a
magnetic field.
1
V1.10
May 1, 2011
SS40A
CMOS Omnipolar High Sensitivity Micropower Hall Switch
Typical Application Circuit
SEC's pole-independent sensing technique allows for operation with either a north pole or south pole magnet
orientation, enhancing the manufacturability of the device. The state-of-the-art technology provides the same output
polarity for either pole face.
It is strongly recommended that an external bypass be connected (in close proximity to the Hall sensor) between the
supply and ground of the device to reduce both external noise and noise generated by the chopper-stabilization
technique. This is especially true due to the relatively high impedance of battery supplies.
Functional Block Diagrams
V DD Voltage Output GND Amp
Hall Plate 2
V1.10
May 1, 2011
SS40A
CMOS Omnipolar High Sensitivity Micropower Hall Switch
Pin Definitions and Descriptions
SIP Pin №
Name
Type
Function
1
3
2
VDD
OUT
GND
Supply
Output
Ground
Supply Voltage pin
Open Drain Output pin
Ground pin
Table 1: Pin definitions and descriptions
Absolute Maximum Ratings
Parameter
Symbol
Supply Voltage (operating)
V DD
Reverse Voltage,
-V DD
Output Voltage
V OUT
Output Current
I OUT
Operating Temperature Range T A
Storage Temperature Range
TS
ESD Sensitivity
Table 2: Absolute maximum ratings
Value
Units
24
-24
30
50
-20 to 85
-55 to 150
4000
V
V
V
mA
°C
°C
V
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.
DC Electrical Characteristics
DC Operating Parameters: T A = 25℃, V DD = 2.75V.
Parameter
Symbol
Operating Voltage
Supply Current
Saturation Voltage
V DD
I DD
V SAT
I OFF
Output Leakage
Output Rise Time
Output Fall Time
Test Conditions
Min
Typ
Max
Units
4.5
B<B RP , V OUT = 20V
5
5
0.4
0.01
24
10
0.5
5
V
mA
V
µA
tr
RL = 1.1K O, CL = 20pf
0.3
1.5
µS
tf
RL = 1.1K O, CL = 20pf
0.3
1.5
µS
I OUT
Operating
Average
= 20mA, B>B OP
3
V1.10
May 1, 2011
SS40A
CMOS Omnipolar High Sensitivity Micropower Hall Switch
Table 3: DC electrical characteristics
Magnetic Characteristics
Output Voltage (V)
3.0
OFF
2.5
2.0
B OPN
1.5
B RPS
B OPS
B RPN
1.0
0.5
ON
0
-80
-60
-40
-20
0
20
40
60
80
Magnetic Flux (Gauss)
Operating Parameters: T A = 25°C, V DD = 2.75V DC
SS40A
Parameter
Symbol
Min
Operating Point
Release Point
Hysteresis
B OP
B RP
B HYST
-70
60
Type
Max
Units
70
100
Gs
Gs
Gs
Table 4: Magnetic Specifications
ESD Protection
Human Body Model (HBM) tests according to: Mil. Std. 883F method 3015.7
Limit Values
Parameter
Symbol
Unit
Min
Max
ESD Voltage
V ESD
4
kV
Notes
4
V1.10
May 1, 2011
SS40A
CMOS Omnipolar High Sensitivity Micropower Hall Switch
Performance Characteristics
Unique Features
CMOS Hall IC Technology
The chopper stabilized amplifier uses switched capacitor techniques to eliminate the amplifier offset voltage, which,
in bipolar devices, is a major source of temperature sensitive drift. CMOS makes this advanced technique possible.
The CMOS chip is also much smaller than a bipolar chip, allowing very sophisticated circuitry to be placed in less
space. The small chip size also contributes to lower physical stress and less power consumption.
Installation Comments
Consider temperature coefficients of Hall IC and magnetic, as well as air gap and life time variations. Observe
temperature limits during wave soldering. Typical IR solder-reflow profile:
–
No Rapid Heating and Cooling.
–
Recommended Preheating for max. 2minutes at 150°C
–
Recommended Reflowing for max. 5seconds at 240°C
5
V1.10
May 1, 2011
SS40A
CMOS Omnipolar High Sensitivity Micropower Hall Switch
ESD Precautions
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.
6
V1.10
May 1, 2011
SS40A
CMOS Omnipolar High Sensitivity Micropower Hall Switch
0.76  0.05 1.58  0.1 Package UA, 3-Pin
1.9
3  1
0.89
45  1
4.1  0.1 1
2
3
3.18  0.1 Sensor Location 40A 06C
Active Area Depth: 0.84(Nom) 3  1
6  1
3  1
6  1
1
2
0.05  0.05 3
2.3. 0.1 3 ‐ 0.44 14  0.5 3 ‐ 0.44 Notes:
1). Controlling dimension : mm ;
2). Lesds must be free of flash and plating voids ;
3). Do not bend leads within 1 mm of lead to package
interface ;
SIP:
1.27 Ordering Information
Part No.
Pb-free
Temperature Code
Package Code
Packing
SS40AEUA
YES
-40°C to 85°C
TO-92
Bulk, 1000 pieces/bag
SS40AKUA
YES
-40°C to 125°C
TO-92
Bulk, 1000 pieces/bag
SS40ALUA
YES
-40°C to 150°C
TO-92
Bulk, 1000 pieces/bag
7
V1.10
May 1, 2011