500 WATTS MULTIPLE OUTPUT 48 VDC INPUT, FORCED CURRENT SHARING DMX-500 Featuring: • Forced current sharing for N +1 redundancy • Identical output performance as NMX-500 Series with 48 Vdc input • Remote sense on outputs #1 and 2 • Dual converter design eliminates interaction between logic and auxiliary outputs • Low ripple and noise on all outputs • Input transient specification up to 75 V • DC power good signal • True remote inhibit • Monotonic turn-on and turn-off • Designed for use in telephone network systems STANDARD DMX SERIES MODEL PWR DMX-503-0512 DMX-504-1205 DMX-504-1212 DMX-504-1224 DMX-504-1512 DMX-504-1524 500 500 500 500 500 500 OUTPUT #1 +5V +5V +5V +5V +5V +5V @ @ @ @ @ @ 75A 75A 75A 75A 75A 75A OUTPUT #2 OUTPUT #3 +12V @ 8/12A pk +12V @ 8/12A pk +12V @ 8/12A pk +12V @ 8/12A pk +15V @ 4A +15V @ 4A -12V @ 4A -12V @ 4A -12V @ 4A -12V @ 4A -15V @ 4A -15V @ 4A Designed to meet applicable Bellcore and NEBS standards, the DMX Series 500-watt power supplies require DC input. They are DC “clones” of Condor’s popular NMX 500 Series of AC power factor corrected power supplies. This gives you the ability to operate existing systems from central office power (–48 Vdc) simply by changing power supplies. DMX and NMX Series power supplies are directly interchangeable, without compromising performance and without making any mechanical changes for mounting or cooling. DMX and NMX Series power supplies can also be operated in redundant configurations to achieve AC operation with battery backup capability. OUTPUT #4 5.2V @ 5A 12V @ 5A 24V @ 3A 12V @ 5A 24V @ 3A SEE 00T 5 X NMR AC INEPNUT FO UIVAL EQ Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com 500 WATTS 9.65”x 5”x 2.10” DMX-500 Dimensions: DMX-500 DMX-500 with Option F 3.7 lbs - 1.7 kgs 3.9 lbs - 1.8 kgs Inches Millimeters SPECIFICATIONS: ALL MODELS INPUT DC Input: 40-60 Vdc range. Internally fused for 25 A. Efficiency: 75% typical. OUTPUT Adjustability: Outputs #1 and 2 user adjustable ±5% minimum. Output #3 tracks #2; initial accuracy ±4%. Output #4 user adjustable ±5% minimum. Line & Load Reg: Outputs #1, 2, and 4 hold ±1% over DC input range and 0 to 100% load change. Output #3 requires 20% minimum load on outputs #2 and 3 to hold ±4%. Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater. Remote Sense (Outputs #1 and 2): Compensates for 250 mV total line drop. Open sense lead protection. (See Redundancy, below.) Temperature Coefficient (Outputs #1, 2, and 4): 0.02% per degree C. Stability: 0.1% over 8 hours after 30 minutes warm-up. Transient Response (Outputs #1, 2, and 4): Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed 5%. Overload Protection: All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection (Outputs #1 and 2): Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Peak Output Current: Dual current ratings define continuous and peak currents. The peak current shown can be delivered for a maximum period of 30 seconds. Remote Inhibit: Contact closure to the negative sense line or a TTL level “0” turns off DC outputs. Redundancy: External OR-ing diodes and forced current sharing on output #1 provide “N+1” capability. Remote sense (+S) compensates for additional 0.6 V diode voltage drop. When the current sharing terminal is connected among units, current sharing remains within 10% of the unit’s full output current rating. DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6 V nominal. Reverse Voltage: Protected against reverse voltage up to supply current rating. ENVIRONMENTAL Thermal Protection: Shuts down power supply if overheated. Automatic recovery. Temperature Range: 0° to 50°C at full ratings. Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive). Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B. Cooling: 30 CFM required to achieve full ratings. Output Isolation: Isolated from ground 50 Vdc. DC INPUT FUNCTION TB1- (– ) TB1- ( + ) TB1- ( ) 48 Vdc -48 VDC Input -48 VDC Return Safety Ground DC OUTPUT FUNCTION Output #1 Output #2 Output #3 Output #4 LOCATION Terminal marked +V Terminal marked -V J1-5, 10 J1-4, 9 J1-3, 8 J1-4, 9 J1-2, 7 J1-1, 6 Consult factory for other available options. NOTES Main Output Rtn (Common) CONNECTOR Bus bars #8-32 screws Rtn (Common) Rtn (Common) (+) Floating Output (–) Floating Output AMP #770743-1 mates with connector #770580-1 with sockets #171639-1 STATUS AND CONTROL FUNCTION Remote Sense DC Power Good Inhibit LOCATION J2-2 J2-1 J2-8 J2-7 J2-3 J2-5 OPTIONS: Option “F”, Fan/Cover Assembly: Cover with integral ball-bearing fan provides proper cooling to achieve full ratings at 50°C ambient temperature. 2.10” dimension increases to 3.31”. Option “V”, Fan/Cover Assembly: Low profile, end venting cover with integral ball-bearing fan. 2.10” dimension increases to 2.50”, and 9.65” dimension increases to 11”. CONNECTOR Barrier strip #6-32 screws 3/8” centers Current Share Aux. Fan Voltage (Not available with “V” or “F” options) J2-6 J3-1 J3-2 NOTES Output #1 Sense Output #1 Sense Rtn Output #2 Sense Output #2 Sense Rtn Reference to Common Reference to Common when #1 Sense Rtn is terminated. +12V @ 0.5A Output Rtn (Common) CONNECTOR AMP MTA type #640456-8 pin header (locking) AMP MTA type #640456-2 pin header (locking) Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com