500 WATTS POWER FACTOR CORRECTED MULTIPLE OUTPUT, FORCED CURRENT SHARING NMX-500 Option V Featuring: • Forced current sharing for N +1 redundancy • Remote sense on outputs #1 and 2 • Universal AC input • 0.99 typical power factor • Dual converter design eliminates interaction between logic and auxiliary outputs • Low ripple and noise on all outputs • DC power good and AC power fail signals • True remote inhibit • Monotonic turn-on and turn-off SEE 00T 5 X DMR DC INEPNUT FO UIVAL EQ STANDARD NMX SERIES MODEL PWR NMX-503-0512 NMX-504-1205 NMX-504-1212 NMX-504-1224 NMX-504-1512 NMX-504-1524 500 500 500 500 500 500 OUTPUT #1 +5V +5V +5V +5V +5V +5V @ @ @ @ @ @ 75A 75A 75A 75A 75A 75A OUTPUT #2 OUTPUT #3 +12V @ 8/12A pk +12V @ 8/12A pk +12V @ 8/12A pk +12V @ 8/12A pk +15V @ 4A +15V @ 4A -12V @ 4A -12V @ 4A -12V @ 4A -12V @ 4A -15V @ 4A -15V @ 4A OUTPUT #4 5.2V @ 5A 12V @ 5A 24V @ 3A 12V @ 5A 24V @ 3A MASS STORAGE NMX-502 SERIES* MODEL PWR OUTPUT #1 OUTPUT #2 NMX-502-0512V 500 +5V @ 30A +12V @ 30/40Apk *Contact factory for detailed mechanical and electrical specifications. The drawings on opposite page do not represent this NMX product. The NMX-502 features dual bus-bar outputs and integrated ”V” option. The smallest, most capable 500 W power supply of its kind. Overload-, overvoltage-, thermal-protection and integral covers are standard. All NMX power supplies can be ordered self-cooled with internal ball-bearing fans. The NMX 350 and NMX 500 are available without fans for use with system air cooling. All outputs are OEM-adjustable and 3 V main outputs are available. Integral RFI filters allow every NMX power supply to meet conducted emissions of EN55022 class B and FCC Class A. Compliance is also provided for international safety requirements including IEC 950 and the requirements of IEC 555-2 for harmonic line distortion. Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com 500 WATTS 9.65”x 5”x 2.05” NMX-500 NMX-500 NMX-500 with Option F 3.7 lbs - 1.7 kgs 3.9 lbs - 1.8 kgs SPECIFICATIONS: ALL MODELS INPUT AC Input: 90-264 Vac continuous range, 47 to 63 Hz. Internally fused for 10 A. Power Factor: 0.99 typical at full load. Meets EN61000-3-2. Inrush: Cold start AC current is less than 30 A at 115 Vac and 60 A at 230 Vac. Limited by thermistor. Brownout Protection: Holds regulation to 85 Vac. Holdup Time: 20 ms minimum after removal of power at full load. Efficiency: 75% typical. AC Power Fail: Provides TTL “0” 5 ms before output voltage goes out of regulation band upon loss of ac power. OUTPUT Adjustability: Outputs #1 and 2 user adjustable ±5% minimum. Output #3 tracks #2; initial accuracy ±4%. Output #4 user adjustable ±5% minimum, or +5% only if voltage is 5.2 V Line & Load Reg: Outputs #1, 2, and 4 hold ±1% over AC input range and 0 to 100% load change. Output #3 requires 20% minimum load on outputs #2 and 3 to hold ±4%. Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater. Remote Sense (Outputs #1 and 2): Compensates for 250 mV total line drop. Open sense lead protection. (See Redundancy, below.) Temperature Coefficient (Outputs #1, 2, and 4): 0.02% per degree C. Stability: 0.1% over 8 hours after 30 minutes warm-up. Transient Response (Outputs #1, 2, and 4): Output voltage returns to within 1% in less than 500 µs for a 50% load change. Peak transient does not exceed 5%. Overload Protection: All outputs are protected against overload and short circuit. Automatic recovery upon removal of fault. Overvoltage Protection (Outputs #1 and 2): Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 136% of nominal. Peak Output Current: Dual current ratings define continuous and peak currents. The peak current shown can be delivered for a maximum period of 30 seconds. Remote Inhibit: Contact closure to the negative sense line or a TTL level “0” turns off DC outputs. DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6 V nominal. Redundancy: External OR-ing diodes and forced current sharing on output #1 provide “N+1” capability. Remote sense (+S) compensates for additional 0.6 V diode voltage drop. When the current sharing terminal is connected between units, current sharing remains within 10% of the unit’s full output current rating. For hot swap applications see TMX 350. Reverse Voltage: Protected against reverse voltage up to supply current rating. ENVIRONMENTAL Thermal Protection: Shuts down power supply if overheated. Automatic recovery. Temperature Range: 0° to 50°C at full ratings. Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive). Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B. Output Isolation: Isolated from ground 50 Vdc. Cooling: 30 CFM required to achieve full ratings. Dimensions: OPTIONS: Inches Millimeters Option “F”, Fan/Cover Assembly: Cover with integral ball-bearing fan provides proper cooling to achieve full ratings at 50°C ambient temperature. 2.05” dimension increases to 3.28”. Option “V”, Fan/Cover Assembly: Low profile, end venting cover with integral ball-bearing fan. 2.05” dimension increases to 2.50”, and 9.65” dimension increases to 11”. Consult factory for other available options. AC INPUT (90-264 VAC Continuous Range) FUNCTION TB1- (L ) TB1- (N) TB1- ( ) 115 VAC Line Neutral Safety Ground 230 VAC Line 1 Line 2 Safety Ground LOCATION Terminal marked +V Terminal marked -V J1-5, 10 J1-4, 9 J1-3, 8 J1-4, 9 J1-2, 7 NOTES Main Output Rtn (Common) CONNECTOR Barrier strip #6-32 screws 3/8” centers DC OUTPUT FUNCTION Output #1 Output #2 Output #3 Output #4 J1-1, 6 CONNECTOR Bus bars #8-32 screws Rtn (Common) Rtn (Common) (+) Floating Output (–) Floating Output AMP #770743-1 mates with connector #770580-1 with sockets #171639-1 (AWG #20 to #16) STATUS AND CONTROL FUNCTION Remote Sense DC Power Good AC Power Fail Inhibit Current Share Aux. Fan Voltage (Not available with “V” or “F” options) LOCATION J2-2 J2-1 J2-8 J2-7 J2-3 J2-4 J2-5 J2-6 J3-1 J3-2 NOTES Output #1 Sense Output #1 Sense Rtn Output #2 Sense Output #2 Sense Rtn Reference to Common +12V @ 0.5A Output Rtn (Common) CONNECTOR AMP MTA type #640456-8 pin header (locking) AMP MTA type #640456-2 pin header (locking) Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com