200 WATTS POWER FACTOR CORRECTED WIDE RANGE ADJUSTABLE MULTIPLE OUTPUTS PBO-200 Option CF Featuring: • 200 W continuous – 240 W peak power • Universal input for 115 V or 230 V, 47-65 Hz, single phase AC • Four independently isolated and regulated outputs • Wide range of adjustable auxiliary outputs (up to 2.6:1) • Up to 50% greater peak currents on two outputs • Typical power factor – 0.99 • Low ripple and noise on all outputs • Typical 70% efficiency • DC power good signal • Remote on/off and remote sense features • Low profile fan/cover option STANDARD PBO SERIES MODEL PBO-200 PWR OUTPUT #1 200 W 4.75 V to 5.25 V (Cont.) @ 240 W 3.0 A to 30.0 A (Peak) OUTPUT #2 OUTPUT #3 11.5 V to 25.2 V 9.5 V to 15.8 V @ @ 0.4 to 4.0 A 0.4 to 5.0 A 6.0 A (Peak) 6.0 A (Peak) The PBO 200 series of high-reliability, AC input power supplies are designed for computer, networking, telecommunication and industrial equipment applications. These models feature a universal power factor corrected input plus independently isolated and regulated outputs. The auxiliary outputs are adjustable over a wide range (up to 2.6 to 1). This wide range of adjustability provides OUTPUT #4 4.75 V to 12.6 V @ 0.3 A to 3.0 A greater flexibility, especially in meeting non-standard output voltage requirements. Outputs may be connected in either polarity or stacked in series as needed. Outputs 2 and 3 accommodate up to 50% greater peak currents for applications with surge requirements. The optional cover with fan provides a low-profile cooling solution that increases the overall height by only 0.25”. Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com 200 WATTS 9”x 5”x 2” PBO-200 PBO-200 2.7 lbs - 1.4 kgs Dimensions: SPECIFICATIONS: ALL MODELS INPUT AC Input: 85-264 V AC continuous range, 47 to 65 Hz. Internally fused at 6.3 A. Power Factor: 0.99 typical at full load. Meets EN61000-3-2. Inrush: Cold start AC current is less than 35 A at 115 Vac and 70 A at 230 Vac. Limited by a thermistor. Brownout Protection: Holds regulation to 85 Vac. Holdup Time: 20 ms after removal of power at nominal line and full load. Efficiency: 75% typical. AC Power Fail: Provides TTL “0” 6 ms before output voltage goes out of regulation band upon loss of ac power. Also provides a TTL level “0” for 100 ms (minimum) at starting. OUTPUT Adjustability: Output #1 is adjustable ±5%. Output #3 and 4 are wide range adjustable, (see table). Line & Load Reg: ±0.6% on all outputs over AC input range and loads within the ranges specified in the table. Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater. Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead protection. Temperature Coefficient: To be determined. Stability: 0.1% over 8 hours after 30 minutes warm-up. Transient Response: Output voltage returns to within 1% in less than 500 µs for a 25% load change. Peak transient does not exceed 3%. Overload Protection: All outputs are protected against overload and Input Cycling off/on is required to reset latched-off protection mode. Overvoltage Protection (Output #1): Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 6.5 V. Peak Output Current: (Outputs #2 and 3) Dual current ratings define continuous and peak currents. The peak current shown can be delivered for a maximum period of 15 seconds. Remote Inhibit: Contact closure to the negative sense line or a TTL level “0” turns off DC outputs. DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6 V nominal. Redundancy: External OR-ing diodes and forced current sharing on output #1 provide “N+1” capability. Remote sense (+S) compensates for additional 0.6 V diode voltage drop. When the current sharing terminal is connected between units, current sharing remains within 10% of the unit’s full output current rating. Reverse Voltage: Protected against reverse voltage up to supply current rating. Cooling: 30 CFM required to achieve full ratings. Enable: Contact closure in the negative output #1 terminal or a TTL level “0”, turns off DC outputs. Inches Millimeters ENVIRONMENTAL Thermal Protection: Shuts down power supply if overheated. Automatic recovery. Temperature Range: 0° to 40°C at full ratings.Output power linearly derated to 50% at 70°C. Safety Agencies: UL1950; CSA 22.2 #950; VDE 0805 / EN 60950 CE markings to low voltage directive – All pending. Conducted RFI: Meets FCC Part 151 Class B. EN 55022/B. Output Isolation: Isolated from ground 50 Vdc. Cooling: 30 CFM required to achieve full ratings. OPTIONS: Option CF: Available with enclosed cover and fan. Consult factory for other available options. AC INPUT (90-264 VAC Continuous Range) FUNCTION TB1- (L ) TB1- (N) TB1- ( ) 115 VAC Line Neutral Safety Ground 230 VAC Line 1 Line 2 Safety Ground LOCATION TB2-1 TB2-2 TB3-1 TB3-2 TB3-3 TB3-4 TB3-5 TB3-6 NOTES 4.75V to 5.25V Rtn (Isolated) 11.5V to 25.2V Rtn (Isolated) 9.5V to 15.8V Rtn (Isolated) 4.75V to 12.6V Rtn (Isolated) CONNECTOR Barrier strip #6-32 screws 0.375 inch centers DC OUTPUT FUNCTION Output #1 Output #2 Output #3 Output #4 CONNECTOR Bus Bars # 8 - 32 Screws Barrier strip #6-32 screws 0.325 inch centers STATUS AND CONTROL FUNCTION Enable DC Power Good Remote Sense J1-1 J1-2 J1-4 J1-3 LOCATION STATUS Enable Output #1 Rtn DC Power Good Output #1 Rtn J2-2 J2-1 Output #1 Sense + Output #1 Sense - CONNECTOR Molex part # 22 - 23 - 2041 mates with Molex part # 22 - 01 - 3047 Molex part # 22 - 23 - 2021 mates with Molex part # 22 - 01 - 3027 Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com