SLPOWER PBO-200

200 WATTS
POWER FACTOR CORRECTED
WIDE RANGE ADJUSTABLE MULTIPLE OUTPUTS
PBO-200
Option CF
Featuring:
• 200 W continuous – 240 W peak
power
• Universal input for 115 V or 230 V,
47-65 Hz, single phase AC
• Four independently isolated and
regulated outputs
• Wide range of adjustable auxiliary
outputs (up to 2.6:1)
• Up to 50% greater peak currents on
two outputs
• Typical power factor – 0.99
• Low ripple and noise on all outputs
• Typical 70% efficiency
• DC power good signal
• Remote on/off and remote sense
features
• Low profile fan/cover option
STANDARD PBO SERIES
MODEL
PBO-200
PWR
OUTPUT #1
200 W 4.75 V to 5.25 V
(Cont.)
@
240 W 3.0 A to 30.0 A
(Peak)
OUTPUT #2
OUTPUT #3
11.5 V to 25.2 V 9.5 V to 15.8 V
@
@
0.4 to 4.0 A
0.4 to 5.0 A
6.0 A (Peak)
6.0 A (Peak)
The PBO 200 series of high-reliability,
AC input power supplies are designed
for computer, networking, telecommunication and industrial equipment applications. These models feature a universal
power factor corrected input plus independently isolated and regulated outputs.
The auxiliary outputs are adjustable
over a wide range (up to 2.6 to 1). This
wide range of adjustability provides
OUTPUT #4
4.75 V to 12.6 V
@
0.3 A to 3.0 A
greater flexibility, especially in meeting
non-standard output voltage requirements. Outputs may be connected in
either polarity or stacked in series as
needed. Outputs 2 and 3 accommodate up to 50% greater peak currents
for applications with surge requirements. The optional cover with fan provides a low-profile cooling solution that
increases the overall height by only
0.25”.
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com
200 WATTS
9”x 5”x 2”
PBO-200
PBO-200
2.7 lbs - 1.4 kgs
Dimensions:
SPECIFICATIONS: ALL MODELS
INPUT
AC Input: 85-264 V AC continuous range, 47 to 65 Hz. Internally fused at 6.3 A.
Power Factor: 0.99 typical at full load. Meets EN61000-3-2.
Inrush: Cold start AC current is less than 35 A at 115 Vac and 70 A at 230 Vac. Limited by a
thermistor.
Brownout Protection: Holds regulation to 85 Vac.
Holdup Time: 20 ms after removal of power at nominal line and full load.
Efficiency: 75% typical.
AC Power Fail: Provides TTL “0” 6 ms before output voltage goes out of regulation band
upon loss of ac power. Also provides a TTL level “0” for 100 ms (minimum) at starting.
OUTPUT
Adjustability: Output #1 is adjustable ±5%. Output #3 and 4 are wide range adjustable,
(see table).
Line & Load Reg: ±0.6% on all outputs over AC input range and loads within the ranges
specified in the table.
Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater.
Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead
protection.
Temperature Coefficient: To be determined.
Stability: 0.1% over 8 hours after 30 minutes warm-up.
Transient Response: Output voltage returns to within 1% in less than 500 µs for a 25% load
change. Peak transient does not exceed 3%.
Overload Protection: All outputs are protected against overload and Input Cycling off/on is
required to reset latched-off protection mode.
Overvoltage Protection (Output #1): Protects load against power supply induced
overvoltage. Trip point is factory set so that output voltage cannot exceed 6.5 V.
Peak Output Current: (Outputs #2 and 3) Dual current ratings define continuous and peak
currents. The peak current shown can be delivered for a maximum period of 15 seconds.
Remote Inhibit: Contact closure to the negative sense line or a TTL level “0” turns off DC
outputs.
DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6 V nominal.
Redundancy: External OR-ing diodes and forced current sharing on output #1 provide “N+1”
capability. Remote sense (+S) compensates for additional 0.6 V diode voltage drop. When
the current sharing terminal is connected between units, current sharing remains within
10% of the unit’s full output current rating.
Reverse Voltage: Protected against reverse voltage up to supply current rating.
Cooling: 30 CFM required to achieve full ratings.
Enable: Contact closure in the negative output #1 terminal or a TTL level “0”, turns off DC
outputs.
Inches
Millimeters
ENVIRONMENTAL
Thermal Protection: Shuts down power supply if overheated. Automatic recovery.
Temperature Range: 0° to 40°C at full ratings.Output power linearly derated to 50% at 70°C.
Safety Agencies: UL1950; CSA 22.2 #950; VDE 0805 / EN 60950 CE markings to low voltage
directive – All pending.
Conducted RFI: Meets FCC Part 151 Class B. EN 55022/B.
Output Isolation: Isolated from ground 50 Vdc.
Cooling: 30 CFM required to achieve full ratings.
OPTIONS:
Option CF: Available with enclosed cover and fan.
Consult factory for other available options.
AC INPUT (90-264 VAC Continuous Range)
FUNCTION
TB1- (L )
TB1- (N)
TB1- ( )
115 VAC
Line
Neutral
Safety Ground
230 VAC
Line 1
Line 2
Safety Ground
LOCATION
TB2-1
TB2-2
TB3-1
TB3-2
TB3-3
TB3-4
TB3-5
TB3-6
NOTES
4.75V to 5.25V
Rtn (Isolated)
11.5V to 25.2V
Rtn (Isolated)
9.5V to 15.8V
Rtn (Isolated)
4.75V to 12.6V
Rtn (Isolated)
CONNECTOR
Barrier strip
#6-32 screws
0.375 inch centers
DC OUTPUT
FUNCTION
Output #1
Output #2
Output #3
Output #4
CONNECTOR
Bus Bars
# 8 - 32 Screws
Barrier strip
#6-32 screws
0.325 inch centers
STATUS AND CONTROL
FUNCTION
Enable
DC Power Good
Remote Sense
J1-1
J1-2
J1-4
J1-3
LOCATION
STATUS
Enable
Output #1 Rtn
DC Power Good
Output #1 Rtn
J2-2
J2-1
Output #1 Sense +
Output #1 Sense -
CONNECTOR
Molex part #
22 - 23 - 2041
mates with Molex
part # 22 - 01 - 3047
Molex part #
22 - 23 - 2021
mates with Molex
part # 22 - 01 - 3027
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com