GLC110 Commercial/GLM110 Medical 110 Watt Global Performance Switchers GLOBAL PERFORMANCE SWITCHERS FEATURES: • Cost-effective power source • Single- and dual-output units • Low height (1.30”) • 2-year warranty • Power fail signal standard • Commercial Approved to UL60950-1, EN60950-1, CSA22.2 No. 950-95 3rd Ed. • Medical Approved to UL2601-1, EN60601-1, CSA-C22.2 No. 601.1 • Complies with EN61000-3-2 Class A • RoHS Compliant Model Available (G suffix) SPECIFICATIONS Ac Input 90-264 Vac, 47-63 Hz single phase. Input Current Maximum input current at 90 Vac, 60 Hz with full rated output load not to exceed 2.9 A. Hold-up Time 20 ms minimum from loss of ac input at full load, nominal line (120 Vac). Output Power Normal continuous output power is 75 W for unrestricted natural convection, or 110 W with 26 cfm air flow. Output Regulation Load regulation on dual output models is measured by ±40% load change from 60% rated load and input voltage change from minimum to maximum ratings. Output #1 requires 1A minimum load for proper regulation of other outputs. Initial set tolerance is measured with all outputs at 60% of full rated load. Load regulation for single-output models measured by changing load from 5% to 50% load or 50% to full load in either direction. Voltage Adjustment Output #1 adjustment is ±5%. Note: output #1 must not be more than 1% below nominal to achieve full output regulation on output #2. High voltage settings may degrade the reliability of the unit due to excessive power Transient Response Main Output: 500 μs typical response time for return to within 0.5% of final value for a 50% load step change, ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/shutdown overshoot less than 3%. Turn-On Time less than 1 second at 120 Vac, 25. Overvoltage Protection Built in on main output. Efficiency 72-85% depending on model. Input Protection Internal ac fuse provided on all units. Designed to blow only if a catastrophic failure occurs in the unit. Inrush Current Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A. Temperature Coefficient 0.03%/°C typical on all outputs. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: dissipation in some outputs. EMI SPECIFICATIONS COMPLIANCE LEVEL Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Factory set to begin power limiting at 120 W. Conducted Emissions GLC110 Conducted Emissions GLM110 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility Line Frequency Harmonics EN55022 Class B; FCC Class B EN55011 Class B: FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. EN61000-3-2 Class A Output Noise 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. POWER FAIL Power fail signal is TTL or CMOS compatible (output goes low <0.5 V) 5 ms before output voltage drops more than 4% below nominal voltage upon loss of AC power. The signal is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line impedance and distortion. Other settings are available to the user through adjustment of built in potentiometer (consult factory for assistance). Output will stay low for 20 ms minimum. Commercial Safety All GLC models are approved to UL60950-1, CSA22.2 No. 950-95 3rd Ed, and EN60950-1. Medical Safety All GLM models are approved to UL2601-1, CSA-C22.2 No. 601.1, EN60601-1. All specifications are typical at nominal input, full load at 25OC unless otherwise stated Commercial Model Medical Model GLC110-212 GLM110-212 GLC110-215 GLC110-524 GLM110-215 GLM110-524 RoHS Suffix* Output No. Output Output Minumum Output Normal (A) Forced Air (B) Output Peak Noise P-P OVP Total Regulation ( C ) G 1 +12 V 1A 6.3 A 9.1 A 9.5 A 100 mV 15.6 ± 1.1 V 2% 2 -12 V 0A 2.5 A 3A 4A 120 mV 1 +15 V 1A 5A 7.3 A 7.7 A 120 mV 2 -15 V 0A 2.5 A 3A 4A 150 mV 1 +24 V 1A 3.2 A 4.6 A 4.75 A 200 mV 28 ± 2.5 V 2% 2 +5 V 0A 1.5 A 2A 2.5 A 50 mV 6.2 ± 0.6 V 2% G G 2% 18.5 ± 1.5 V 2% 2% GLC110-12 GLM110-12 G 1 12 V 0A 6.3 A 9.1 A 9.5 A 120 mV 15.6 ± 1.1 V 2% GLC110-15 GLM110-15 G 1 15 V 0A 5A 7.3 A 7.7 A 150 mV 18.5 ± 1.5 V 2% GLC110-24 GLM110-24 G 1 24 V 0A 3.2 A 4.6 A 5A 240 mV 28 ± 2.5 V 2% * Add “G” suffix to part number for RoHS compliant model. Contact factory for availability. A. Rating with unrestricted convection cooling. Total power not to exceed 75 W; no output can exceed rated current. B. Rating with 26 cfm forced air cooling. Total power not to exceed 110 W. C. To maintain regulation V1 current must be at least 1/5 of V2. V1 must not be adjusted more than 1% below nominal and have at least 10% of rated load. GLC110/GLM110 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING Temperature (A) 0 to 50° -40 to +85°C Humidity (A) 0 to 95% RH 0 to 95% RH Shock (C) 20 gpk 40 gpk Altitude -500 to 10,000 ft -500 to 40,000 ft Vibration (B) 1.5 g rms’ 0.003 g /Hz 5 g rms’ 0.026 g2/Hz 2 A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derated output current and toal output power by 2.5% per °C above 50°C. B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: [email protected] Rev. 02/11/10. Data Sheet © 2010 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.