SLPOWER GLC40

GLC40 Commercial
40 WATT GLOBAL PERFORMANCE LOW COST SWITCHERS
GLOBAL PERFORMANCE SWITCHERS
Features:
• Cost-effective power source
• Universal input 90-264 Vac
• 2-year warranty
• Single and multiple outputs
• Overload and overvoltage protection
• Built-in EMI filter
• UL1950, CSA-C22.2 No. 234 Level 3,
IEC950 and EN60950
• Operation at no-load (single output models)
• RoHS Compliant (with G suffix)
•
marked to LVD
SPECIFICATIONS
Ac Input
90-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load not to
exceed 1.3 A.
Output Power
Normal continuous output power is 40 W for unrestricted natural convection cooling, 45 W peak for 60 seconds. During peak load conditions output
regulation may exceed total regulation and noise limits.
Output Regulation
Regulation for multiple-output models measured by ±40% load change from
60% rated load with all other outputs at 60% full rated load and a line voltage change from low line to high line. Initial set tolerance is measured with
all outputs at 60% of full rated load. Output voltage V1 requires 1 A load for
proper regulation of multiple output models. Regulation for single-output
models measured by changing from 5% to 50% load or 50% load to full load
in either direction.
Power Limit
Factory set to begin power limiting at approximately 55 W. Fully protected
against short circuit and output overload. Short circuit protection is cycling
type power limit.
Voltage Setting
Factory set on standard units with fixed resistors for added reliability. 3.3 V unit
has voltage adjustment pot.
Efficiency
70% typical depending on model.
Turn-on Time
Less than 1 second at 120 Vac, 25°C (inversely proportional to input voltage and
thermistor temperature).
Input Protection
Internal ac fuse provided on all units. Designed to blow only if a catastrophic
failure occurs in the unit. Fuse does not blow on overload or short circuit.
Inrush Current
Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac
half-cycle under cold start conditions will not exceed 37 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions
requirements:
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, mode. Measured with noise probe
terminals of the power supply.
EMI SPECIFICATIONS
COMPLIANCE LEVEL
Transient Response
Main Output: 500 μs typical response time for return to within 0.5% of final
value for a 50% load step change, ∆i/ ∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/ shutdown overshoot less than 3%.
Conducted Emissions
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
EN55022 Class A; FCC Class A
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
Overvoltage Protection
Built in on V1 with firing point set per table. OVP firing reduces output #1 and
#2 to less than 50% of nominal voltage in 50 ms.
Safety
All GLC40 models are approved to UL1950, CSA-C22.2 No.
234 Level 3, IEC950 and EN60950. Class I input.
All specifications are typical at nominal input, full load at 25OC unless otherwise stated
Commercial
Model
Output No.
Output
Output Minimum
Output Maximum
V 1 OVP Set
Noise P-P
Total
Regulation
1
+ 5.1 V
1A
3A
+ 6.2 ± 0.6 V
50 mV
2%
2
+ 12 V
0A
2A
120 mV
6%
3
- 12 V
0A
0.4 A
120 mV
5%
1
+ 5.1 V
1A
3A
2
+ 15 V
0A
1.5 A
3
- 15 V
0A
0.4 A
1
+5 V
1A
3A
2
+24 V
0A
3
-12 V
0A
GLC40-3.3G
1
3.3 V
0A
8A
GLC40-5G
1
5V
0A
8A
GLC40-9G
1
9V
0A
4.4 A
GLC40-12G
1
12 V
0A
3.3 A
GLC40-13.8G
1
13.8 V
0A
2.9 A
GLC40-15G
1
15 V
0A
2.7 A
GLC40-24G
1
24 V
0A
GLC40-28G
1
28 V
0A
GLC40AG
GLC40BG
GLC40DG
+ 6.2 ± 0.6 V
50 mV
2%
150 mv
6%
150 mV
5%
50 mV
2%
1A
240 mV
6%
0.4 A
120 mV
5%
4.2 ± 0.6 V
33 mV
2%
6.2 ± 0.6 V
50 mV
2%
11 ±0.9 V
90 mV
2%
14 ± 1.1 V
120 mV
2%
17.7 +/- 1.5 V
138 mV
2%
18.5 ± 1.5 V
150 mV
2%
1.7 A
28.5 ± 2.5 V
240 mV
2%
1.4 A
34 ± 2.8 V
280 mV
2%
+ 6.2 ± 0.6 V
GLC40 MECHANICAL SPECIFICATIONS
SL Power Electronics, Inc. 6050 King Drive, Bldg. A, Ventura, CA, 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: [email protected] . Rev. 10/09.
Data Sheet © 2009 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication.
However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.