SLPOWER PW116

PW116
I T E 6 0 - 9 0 W AT T S E R I E S
#3 Connector pictured
PW116 SWITCH-MODE
P O W E R S U P P LY
PW116
Ault Part No.
Voltage
DC
Max
Amps
Max
Watts
•
100-250 VAC Universal Input
PW116XA05XX_01
5V
12.0
60.0
•
Desktop Style
PW116XA06XX_01
6V
10.0
60.0
•
Single Output to 90W
PW116XA09XX_01
9V
7.80
70.0
•
Regulated Output With Low Ripple
PW116XA12XX_01
12V
6.67
80.0
•
Meets Safety Agency Requirements
PW116XA14XX_01
13.5V
6.15
83.0
•
Complies With EMI/RFI Regulations
PW116XA15XX_01
15V
6.00
90.0
CE Compliant
PW116XA16XX_01
16V
5.60
90.0
•
PW116XA1803_01
18V
5.00
90.0
•
Impact Resistant Polycarbonate Enclosure
PW116XA2403_01
24V
3.75
90.0
•
Private Label Marking Available
PW116XA4803_01
48V
1.87
90.0
•
3 Year Warranty
•
Modified and Custom Designs Also Available
Ault Part No. Key
PW116 X
A
05
XX
__
01
Product
Family
Name
Design
Revision
Changes
Voltage
DC
Connector
#51 - Standard
16V and
under; #3 Standard 18V
and over
Input
Configuration/
Model Type
(see pg. 2)
Denotes
standard
or custom
requirements
Manufacturing
Location
(volume
dependent)
A U LT I N C O R P O R AT E D
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
FAX (1) 763-592-1911 | E-MAIL [email protected] | WEB www.aultinc.com
© Copyright 2005 Ault Inc.
PW116
I T E 6 0 - 9 0 W AT T S E R I E S
Input
Electrical
Voltage
100-250 VAC -10%, +6%
Topology
Switching - Fixed frequency 100KHz
Line Frequency
47 - 63 Hz
Efficiency
Up to 89%
Current
2.0A max. at 90 VAC input
EMI
Complies with EMC Directives
Protection
Internal primary current fuse,
Inrush limiting
CE
CE Compliant
MTBF
100,000 Calculated Hours Minimum
Power Factor Correction
Complies with EN61000-3-2 and
EN61000-3-3 (active)
Environmental
Output
Combined Line and Load
Voltage Regulation
±1% excluding cord
Ripple
1% V p-p max
Transient Response
0.5 msec. for 50% load change typical
Holdup Time
16 msec min. over entire input range
Protection
Foldback overcurrent protection
Short circuit protection
Cord and Connector
5V and 6V: 6 ft, 6 conductor, 18 AWG,
Ault #51 connector. Pinout: Pins 1, 2, 3 =
+V; 4, 5 and 6 = common. 9V, 12V, 13.5V,
15V, 16V: 6 ft, 4 conductor, 18 AWG, Ault
#51 connector. Pinout: Pins 1,4=+V; 3,
6=common. All with overmolded Ferrite
core. 18V, 24V, 48V,: 6 ft, 2 conductor, 18
AWG with overmolded Ferrite core, Ault
#3 connector, center positive.
Operating Temperature
0º to 40º C with no derating
Storage Temperature
-30º to +85º C
Relative Humidity
5% to 95% non-condensing
Altitude
0-10,000 feet
Cooling
Convectional - non vented case
Mechanical
Case and Dimensions
LP7 - Desktop
5.08L x 3.05W x 1.67H (in)
129L x 77W x 40H (mm)
Case Material
94V0 polycarbonate; black is standard
color; other colors available - extra
charges may apply
Weight
13 ounces, 370 grams
(excluding cord)
Safety Approvals
Agency Listings
cULus60950, TUV/IEC EN60950,
Australian, Japanese certification
available - extra fees apply
Input Configuration
IEC320
w/ground
C14
(F)
Connectors
IEC320
w/o ground
C18
(Q)
In case IEC320 type: F=Class I C14 inlet Q=Class II C18 inlet
Specify the Input Configuration Code in your order.
A U LT I N C O R P O R AT E D
7105 Northland Terrace | Minneapolis, Minnesota 55428 | USATEL (1) 763-592-1900
FAX (1) 763-592-1911 | E-MAIL [email protected] | WEB www.aultinc.com
© Copyright 2005 Ault Inc.