TELTRON LAD8N20

Characteristics
TeSys contactors
Model d
Type of contactor
LC1LC1LC1D09…D18
D25…D38
D40
DT20 & DT25 DT32…DT60
LC1D50…D95
LC1-D115 &
LC1-D150
Environment
Rated insulation voltage (Ui)
Rated impulse withstand voltage
(Uimp)
2
Conforming to EN 60947-4-1,
overvoltage category III,
degree of pollution: 3
V
690
Conforming to UL, CSA
V
600
Conforming to EN 60947
kV
6
1000
8
Conforming to standards
IEC 947-1, 947-4-1, NFC 63-110, VDE 0660, BS 5424, JEM 1038,
EN 60947-1, EN 60947-4-1.
GL, DNV, PTB, RINA pending
Product certifications
UL, CSA
Complies with SNCF, Sichere Trennung recommendations
Separation insulation
Conforming to VDE 0106 parts 101
and A1 (project 2/89)
Degree of protection (1)
(front face only)
Conforming to VDE 0106
V
400
Power connection
Protection against direct finger contact IP 2X
Coil connection
Protection against direct finger contact IP 2X (except LC1-D40…D80)
Protective treatment
Conforming to IEC 68
Ambient air temperature
around the device
Storage
°C
- 60…+ 80
Operation
°C
- 5…+ 60
Permissible
°C
- 40…+ 70, for operation at Uc
Maximum operating altitude
Without derating
m
3000
Operating position
Without derating
± 30° possible, in relation to normal vertical mounting plane
Flame resistance
Conforming to UL 94
V1
Shock resistance (2)
1/2 sine wave = 11ms
Vibration resistance (2)
5…300 Hz
“TH”
Conforming to IEC 695-2-1
°C
960
Contactor open
gn
10
8
8
8
6
Contactor closed
gn
15
15
10
10
15
Contactor open
gn
2
Contactor closed
gn
4
4
4
3
4
(1) Protection ensured for the connection cross-sections shown on the next page and for connection via cable.
(2) In the least favourable direction, without change of contact state (coil supplied at Ue).
Selection:
pages 1/6 to 1/35
2/32
References:
pages 2/6 to 2/9
Dimensions:
pages 2/44 to 2/47
Schemes:
pages 2/48 and 2/49
Schneider Electric
Characteristics
TeSys contactors
Model d
Connections for power and control circuits
Type of contactor
LC1-
D09 & D12 D18
DT20 &
(3P)
DT25
D25
D32 D38 D18 (4P)
DT32…DT60
D40
D50 &
D65
D80 &
D95
D115 & D150
Power circuit connections
Connection via cable
Tightening
Screw clamps
2-input connector
Screw
clamps
1-input connector 2-input connector
Flexible cable
1 conductor
without cable end 2 conductors
mm2
mm2
1…4
1…4
1.5…6 1.5…10 2.5…10
1.5…6 1.5…6 2.5…10
2.5…16
2.5…16
2.5…25
2.5…16
2.5…25 4…50
2.5…16 4…25
10…120
10…120 + 10…50
Flexible cable
with cable end
1 conductor
2 conductors
mm2
mm2
1…4
1…2.5
1…6
1…4
2.5…10
2.5…10
2.5…25
2.5…10
2.5…25 4…50
2.5…10 4…16
10…120
10…120 + 10…50
Solid cable
1 conductor
without cable end 2 conductors
mm2
mm2
1…4
1…4
1.5…6 1.5…6 1.5…10
1.5…6 1.5…6 2.5…10
2.5…16
2.5…16
2.5…25
2.5…16
2.5…25 4…50
2.5…16 4…25
10…120
10…120 + 10…50
N° 2
Ø6
N° 2
Ø6
N° 2
Ø6
N° 2
Ø6
N° 2
Ø6
–
–
–
–
Ø 6…Ø 8 Ø 6…Ø 8 Ø 6…Ø 8 –
–
1.7
–
1.7
–
2.5
–
2.5
–
2.5
–
5
–
5
4
9
4
12
2.5
(4: DT25)
2.5
(4: DT25)
4
4
4
–
–
–
–
–
4
4
4
–
–
(10: DT32…DT60)
–
–
–
–
–
–
–
–
–
–
–
–
3 x 16
5 x 25
Screwdriver
Phillips head
Ø flat screwdriver
6 sided key
Tightening torque
N.m
Connection via spring terminals
1 conductor
Flexible cable
without cable end
2 conductors
mm2
mm2
1…6
1…4
1…10
1.5…6
2
Connection via bars or lugs
Bar cross-section
Lug external Ø
mm
8
8
10
10
12
13
16
17
25
Ø of screw
mm
M3.5
M3.5
M4
M4
M5
M5
M6
M6
M8
N° 2
Ø6
N° 2
Ø6
N° 2
Ø6
N° 2
Ø6
N° 2
Ø6
N° 2
Ø8
N° 3
Ø8
–
Ø8
–
–
–
1.7
–
1.7
–
2.5
–
2.5
–
2.5
–
6
–
6
10
8
13
14
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…2.5
1…2.5
Screwdriver
Phillips head
Ø flat screwdriver
Key for hexagonal headed screw
Tightening torque
N.m
Control circuit connections
Connection via cable (tightening via screw clamps)
Flexible cable
1 conductor
without cable end 2 conductors
mm2
mm2
1…4
1…4
1…4
1…4
Flexible cable
with cable end
1 conductor
2 conductors
mm2
mm2
1…4
1…2.5
1…4
1…4
1…4
1…2.5 1…2.5 1…2.5
1…4
1…2.5
1…2.5
1…2.5
1…2.5
1…2.5
1…2.5
1…2.5
1…2.5
1…2.5
Solid cable
1 conductor
without cable end 2 conductors
mm2
mm2
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…4
1…2.5
1…2.5
N.m
N° 2
Ø6
1.7
N° 2
Ø6
1.7
N° 2
Ø6
1.7
N° 2
Ø6
1.7
N° 2
Ø6
1.7
N° 2
Ø6
1.2
N° 2
Ø6
1.2
N° 2
Ø6
1.2
N° 2
Ø6
1.2
mm2
mm2
2.5
2.5
2.5
2.5
2.5
2.5
2.5 –
2.5 –
–
–
–
–
–
–
–
–
–
–
mm
mm
(1)
(1)
–
–
8
M3.5
8
M3.5
8
M3.5
8
M3.5
–
–
–
–
–
N° 2
–
–
–
–
–
Ø6
N.m
–
–
–
–
–
1.2
(1) Spade connector or cable lug, see connection via cable above.
N° 2
Ø6
1.2
N° 2
Ø6
1.2
N° 2
N°6
1.2
Screwdriver
Phillips head
Ø flat screwdriver
Tightening torque
Connection via spring terminals
Flexible cable
1 conductor
without cable end 2 conductors
Connection via bars or lugs
Lug external Ø
Ø of screw
Screwdriver
Phillips head
Ø flat screwdriver
Tightening torque
Selection:
pages 1/6 to 1/35
Schneider Electric
References:
pages 2/6 to 2/9
Dimensions:
pages 2/44 to 2/47
Schemes:
pages 2/48 and 2/49
2/33
Characteristics
TeSys contactors
Model d
Type of contactor
LC1-
D09
DT20
D12
DT25
D18
DT32
D25
20
12
25
18
32
25
40
DT40
Pole characteristics
2
Rated operational current (Ie)
(Ue ≤ 440 V)
In AC-3, θ ≤ 60 °C
In AC-1, θ ≤ 60 °C
A
A
9
25
Rated operational voltage (Ue)
Up to
V
690
690
690
690
Frequency limits
Of the operating current
Hz
25…400
25…400
25…400
25…400
Conventional thermal current (Ith)
θ ≤ 60 °C
A
25
Rated making capacity (440 V)
Conforming to IEC 947
250
250
300
450
Rated breaking capacity (440 V)
Conforming to IEC 947
250
250
300
450
Permissible short-time rating
No current flowing for preceding
15 minutes at θ ≤ 40 °C
For 1 s
For 10 s
For 1 min
For 10 min
A
A
A
A
210
105
61
30
210
105
61
30
240
145
84
40
380
240
120
50
Protection by fuse
against short-circuits (U ≤ 690 V)
Without thermal overload relay,
fuse gG
type 1
A
25
40
50
63
type 2
A
20
25
35
40
With thermal overload relay
A
See pages 2/52 and 2/53, for aM or gG fuse ratings
corresponding to the associated thermal overload relay
Average impedance per pole
At Ith and 50 Hz
mΩ
2.5
2.5
2.5
2
Power dissipation per pole
for the above operating currents
AC-3
AC-1
W
W
0.20
1.56
0.36
1.56
0.8
2.5
1.25
3.2
V
12…690
20
25
25
32
32
40
40
a.c. control circuit characteristics
Rated control circuit voltage (Uc)
Control voltage limits
50 or 60 Hz coils
50/60 Hz coils
50/60 Hz
Operational
Drop-out
Operational
–
–
0.8…1.1 Uc on 50 Hz and
0.85…1.1 Uc on 60 Hz at 60 °C
0.3…0.6 Uc at 60 °C
Drop-out
Average consumption
at 20 °C and at Uc
" 50 Hz Inrush
Sealed
" 60 Hz Inrush
Sealed
Heat dissipation
50 Hz coil
Cos ϕ
50/60 Hz coil
VA
50 Hz coil
Cos ϕ
50/60 Hz coil
VA
60 Hz coil
Cos ϕ
50/60 Hz coil
VA
60 Hz coil
Cos ϕ
50/60 Hz coil
VA
50/60 Hz
Operating time (3)
Closing “C”
Opening “O”
Mechanical life
in millions of operating cycles
50 or 60 Hz coil
50/60 Hz coil on 50 Hz
VA
VA
VA
–
0.75
70
–
0.3
7
–
0.75
70
VA
–
0.3
7.5
W
2…3
ms
ms
12…22
4…19
–
15
Maximum operating rate
In operating cycles per hour
3600
at ambient temperature ≤ 60 °C
(1) Protection ensured for the connection cross-sections shown on page 2/33 and for connection via cable.
(2) In the least favourable direction, without change of contact state (coil supplied at Ue).
(3) The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time “O” is measured from
the moment the coil supply is switched off to the moment the main poles separate.
Selection:
pages 1/6 to 1/35
2/34
References:
pages 2/6 to 2/9
Dimensions:
pages 2/44 to 2/47
Schemes:
pages 2/48 and 2/49
Schneider Electric
D32
DT60
D38
D40
D50
D65
D80
D95
D115
D150
32
50
32
60
38
50
40
60
50
80
65
80
80
125
95
125
115
200
150
200
690
690
690
1000
1000
1000
1000
1000
1000
1000
25…400
25…400
25…400
25…400
25…400
25…400
25…400
25…400
25…400
25…400
50
60
50
60
80
80
125
125
200
200
550
500
550
800
900
1000
1100
1100
1260
1660
550
500
550
800
900
1000
1100
1100
1100
1400
430
260
138
60
430
260
138
60
430
310
150
60
720
320
165
72
810
400
208
84
900
520
260
110
990
640
320
135
1100
800
400
135
1100
950
550
250
1400
1200
580
250
63
63
63
80
100
160
200
200
250
315
63
63
63
80
100
125
160
160
200
250
2
See pages 2/52 and 2/53, for aM or gG fuse ratings corresponding to the associated thermal overload relay
2
2
2
1.5
1.5
1
0.8
0.8
0.6
0.6
2
5
2
5
3
5
2.4
5.4
3.7
9.6
4.2
6.4
5.1
12.5
7.2
12.5
7.9
24
13.5
24
12…690
24…660
24…500
–
–
0.8…1.1 Uc on 50 Hz and
0.85…1.1 Uc on 60 Hz at 60 °C
0.3…0.6 Uc at 60 °C
0.85…1.1 Uc at 55 °C
0.3…0.6 Uc at 55 °C
0.8…1.1 Uc on 50 Hz and
0.85…1.1 Uc on 60 Hz at 55 °C
0.3…0.6 Uc at 55 °C
0.85…1.1 Uc at 55 °C
0.3…0.5 Uc at 55 °C
–
0.75
70
200
0.75
245
300
0.8
280…350
–
0.9
280…350
–
0.3
7
20
0.3
26
22
0.3
2…18
–
0.9
2…18
–
0.75
70
220
0.75
245
300
0.8
280…350
–
0.9
280…350
–
0.3
7.5
22
0.3
26
22
0.3
2…18
–
0.9
2…18
2…3
6…10
3…8
3…4.5
12…22
4…19
20…26
8…12
20…26
8…12
20…26
8…12
20…35
6…20
20…35
6…20
20…50
6…20
20…35
40…75
–
15
16
6
16
6
16
6
10
4
10
4
8
8
–
8
3600
3600
3600
3600
3600
3600
2400
1200
Schneider Electric
0.8…1.15 Uc on 50/60 Hz at 55 °C
0.3…0.5 Uc at 55 °C
2/35
Characteristics (continued)
TeSys contactors
Model d
d.c. control circuit characteristics
Type of contactor
LC1- or LP1D40…D65
12…440
24…440
Rated control circuit voltage (Uc)
$
V
12…440
Rated insulation voltage
Conforming to IEC 947-1
V
690
Conforming to UL, CSA
V
600
Control voltage limits
Operational
$
Average consumption
at 20 °C and at Uc
Average operating time (1)
at Uc
Closing
LC1 or
LP1-D80
LC1-D115 &
LC1-D150
Standard coil
0.7…1.25 Uc
at 60 °C
0.85…1.1 Uc at 55 °C
0.75…1.2 Uc
at 55 °C
Wide range coil
–
0.75…1.2 Uc at 55 °C
–
0.1…0.25 Uc
at 60 °C
0.1…0.3 Uc at 55 °C
0.15…0.4 Uc
at 55 °C
Drop-out
2
LC1D09…D38
DT20…DT60
Inrush
W
5.4
22
22
270 to 365
Sealed
W
5.4
22
22
2.4…5.1
“C”
ms
55
85…110
95…130
20…35
Opening
“O”
ms
20
20…35
20…35
40…75
Note: The arcing time depends on the circuit switched by the poles. For normal 3-phase applications, the arcing time
is usually less than 10 ms. The load is isolated from the supply after a time equal to the sum of the opening time and
the arcing time.
Time constant (L/R)
ms
28
65
75
25
Mechanical life at Uc
In millions of operating cycles
30
20
20
8
Maximum operating rate
at ambient temperature ≤ 60 °C
In operating cycles per hour
3600
3600
3600
1200
Low consumption control circuit characteristics
Rated insulation voltage
Conforming to EN 60947-1
V
690
Conforming to UL, CSA
V
600
Maximum voltage
Of the control circuit on $
Average consumption
d.c.
at 20 °C and at Uc
Wide range coil
(0.7…1.25 Uc)
Operating time (1)
at Uc and at 20 °C
Voltage limits (θ ≤ 60 °C)
of the control circuit
Inrush
W
2.4
Sealed
W
2.4
Closing
“C”
ms
70
Opening
“O”
ms
25
Operational
0.7 to 1.25 Uc
Drop-out
0.1…0.3 Uc
Time constant (L/R)
Mechanical life
250
ms
In millions of operating cycles
40
30
Maximum operating rate
At ambient temperature ≤ 60 °C
ops/h 3600
(1) Operating times depend on the type of contactor electromagnet and its control mode.
The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time “O” is measured from the
moment the coil supply is switched off to the moment the main poles separate.
(2) In the least favourable direction, without change of contact state.
Selection:
pages 1/6 to 1/35
2/36
References:
pages 2/6 to 2/9
Dimensions:
pages 2/44 to 2/47
Schemes:
pages 2/48 and 2/49
Schneider Electric
Characteristics (continued)
TeSys contactors
Model d
Contactor integral auxiliary contact characteristics
Linked contacts conforming to
draft standard IEC 947-4-5
Each contactor has 2 N/O and N/C contacts mechanically linked on the same movable contact holder
Mirror contact
The N/C contact on each contactor represents the state of the power contacts and can be connected to a
PREVENTA safety module
Rated operational voltage (Ue)
Up to
V
690
Rated insulation voltage (Ui)
Conforming to IEC 947-1
V
690
Conforming to UL, CSA
V
600
For ambient temperature ≤ 60 °C
A
10
Hz
25…400
U min.
V
17
I min.
mA
5
Conventional thermal current (Ith)
Operating current frequency
Minimum switching capacity
λ = 10–8
2
Short-circuit protection
Conforming to EN 60947-5-1
gG fuse: 10 A
Rated making capacity
Conforming to EN 60947-5-1, I rms
A
": 140, $: 250
Short-time rating
Permissible for
A
A
A
100
120
140
MΩ
> 10
ms
1.5 on energisation and on de-energisation
1s
500 ms
100 ms
Insulation resistance
Non-overlap time
Guaranteed between N/C and N/O contacts
Contact operating power
conforming to EN 60947-5-1
1 million operating cycles
3 million operating cycles
10 million operating cycles
a.c. supply categories AC-14 and AC-15
Electrical life (valid for up to 3600 operating cycles/hour)
on an inductive load such as the coil of an electromagnet:
making power (cos ϕ 0.7) = 10 times the power broken
(cos ϕ 0.4).
d.c. supply category DC-13
Electrical life (valid for up to 1200 operating cycles/hour)
on an inductive load such as the coil of an electromagnet,
without economy resistor, the time constant increasing
with the load.
V
VA
VA
VA
V
W
W
W
24
60
16
4
48
120
32
8
115
280
80
20
230
560
160
40
440
1050
300
80
600
1440
420
100
24
96
48
14
48
76
38
12
125
76
38
12
250
76
32
–
440
44
–
–
DC-13
Millions of operating cycles
Millions of operating cycles
AC-15
400
960
280
70
1
8
7
6
5
4
3
2
1
8
7
6
5
4
125 V
3
250 V
2
1
0,8
0,7
0,6
0,5
1
0,8
0,7
0,6
0,5
0,4
0,4
0,3
0,3
0,2
0,2
0,1
24 V
48 V
440 V
0,1
0,1
0,2
0,3
0,4
0,5
Selection:
pages 1/6 to 1/35
Schneider Electric
0,6 0,8 1
0,7 0,9
2
References:
pages 2/6 to 2/9
3
4
6
8 10
5
7
9
Current broken in A
0,1
Dimensions:
pages 2/44 to 2/47
0,2
0,3
0,4
0,5
0,6 0,8 1
0,7 0,9
2
3
4
6
8 10
5
7
9
Current broken in A
Schemes:
pages 2/48 and 2/49
2/37
Characteristics
TeSys contactors
Auxiliary contact blocks without
dust and damp protected contacts
for model d contactors
Contact block type
LAD-N or C LAD-T & S
LAD-R
LAD-8
Environment
2
Conforming to standards
IEC 947-5-1, NF C 63-140, VDE 0660, EN 60947-5-1
Product certifications
UL, CSA
Protective treatment
Conforming to IEC 68
“TH”
Degree of protection
Conforming to VDE 0106
Protection against direct finger contact IP 2X
Ambient air temperature
around the device
Storage
°C
- 60…+ 80
Operation
°C
- 5…+ 60
Permissible for operation at Uc
°C
- 40…+ 70
Maximum operating altitude
Without derating
m
3000
Cabling
Phillips N° 2 and Ø 6 mm
Flexible or solid cable with or without cable end
mm2
Min.: 1 x 1; max.: 2 x 2.5
Connection by spring terminals
Flexible or solid cable without cable end
mm2
Max.: 2 x 2.5
Instantaneous and time delay contact characteristics
Number of contacts
1, 2 or 4
Rated operational voltage (Ue)
Up to
V
690
Rated insulation voltage (Ui)
Conforming to EN 60947-5-1
V
690
Conforming to UL, CSA
V
600
For ambient temperature ≤ 60 °C
A
10
Hz
25…400
U min.
V
17
I min.
mA
5
Conventional thermal current (Ith)
Frequency of operational current
Minimum switching capacity
2
Short-circuit protection
Conforming to EN 60947-5-1 and VDE 0660. gG fuse A
10
Rated making capacity
Conforming to EN 60947-5-1, I rms
A
": 140; $: 250
Short-time rating
Permissible for:
1s
A
100
500 ms
A
120
100 ms
A
140
MΩ
> 10
Insulation resistance
2
2
Non-overlap time
Guaranteed between N/C and N/O contacts
ms
1.5 (on energisation and on de-energisation)
Overlap time
Guaranteed between N/C and N/O on LAD-C22
ms
1.5
–
–
–
Time delay
(LAD-T, R and S contact blocks)
Accuracy only valid for setting range
indicated on the front face
Ambient air temperature for operation
°C
–
- 40…+ 70
- 40…+ 70
–
Repeat accuracy
–
± 2%
± 2%
–
Drift up to 0.5 million operating cycles
–
+ 15 %
+ 15 %
–
Drift depending on ambient air temperature
–
0.25 % per °C 0.25 % per °C –
In millions of operating cycles
30
5
Mechanical durability
Operational power of contacts
References:
pages 2/17 and 2/18
2/38
Dimensions:
pages 2/44 and 2/45
5
30
See page 2/40
Schemes:
pages 2/48 and 2/49
Schneider Electric
Characteristics
TeSys contactors
Auxiliary contact blocks with
dust and damp protected contacts
for model d contactors
Contact block type
LA1-DX
LA1-DX
protected
LA1-DY
non protected
Environment
Conforming to standards
IEC 947-5-1, VDE 0660
Product certifications
UL, CSA
Protective treatment
Conforming to IEC 68
“TH”
Degree of protection
Conforming to VDE 0106
Protection against direct finger contact IP 2X
Ambient air temperature
Storage and operation
°C
- 25…+ 70
Cabling
Phillips N° 2 and Ø 6 mm
Flexible or solid cable
with or without cable end
mm2
Min.: 1 x 1
Max.: 2 x 2.5
Number of contacts
2
2
2
2
2
Contact characteristics
Rated operational voltage (Ue)
Up to
V
50
50
690
24
Rated insulation voltage (Ui)
Conforming to IEC 947-5-1
V
250
250
690
250
Conforming to UL, CSA
V
–
–
600
–
For ambient temperature ≤ 40 °C
A
–
–
10
–
Maximum operational current (Ie)
mA
50
50
10
50
Frequency of operational current
Hz
–
–
25…400
–
U min.
V
3
3
17
3
I min.
mA
0.3
0.3
5
0.3
Conventional thermal current (Ith)
Minimum switching capacity
Short-circuit protection
Conforming to EN 60947-5-1. gG fuse A
–
–
10
–
Rated making capacity
Conforming to EN 60947-5-1, I rms
A
–
–
": 140; $: 250
–
Short-time rating
Permissible for:
1s
A
–
–
100
–
500 ms
A
–
–
120
–
100 ms
A
–
–
140
–
MΩ
> 10
> 10
> 10
> 10
5
5
30
5
Gold - Single
break with
crossed bars
Gold - Single
break with
crossed bars
–
Gold - Single
break with
crossed bars
Insulation resistance
Mechanical durability
In millions of operating cycles
Materials and technology
used for dust and damp
protected contacts
References:
page 2/17
Schneider Electric
Dimensions:
pages 2/44 and 2/45
Schemes:
pages 2/48 and 2/49
2/39
Characteristics
TeSys contactors
Auxiliary contact blocks with
dust and damp protected contacts
for model d contactors
Operational power of contacts (conforming to EN 60947-5-1)
a.c. supply, categories AC-14 and AC-15
Electrical durability (valid up to 3600 operating cycles/hour) on an inductive load such as the coil of an electromagnet:
making power (cos ϕ 0.7) = 10 times the power broken (cos ϕ 0.4).
V
VA
VA
VA
Millions of operating cycles
1 million operating cycles
3 million operating cycles
10 million operating cycles
2
24
60
16
4
48
120
32
8
115
280
80
20
230
560
160
40
400
960
280
70
440
1050
300
80
600
1440
420
100
1
8
7
6
5
4
3
2
1
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
0,1
0,2
0,3
0,4
0,5
0,6 0,8 1
0,7 0,9
2
3
4
6
8 10
5
7
9
Current broken in A
d.c. supply, category DC-13
Electrical durability (valid up to 1200 operating cycles/hour) on an inductive load such as the coil of an electromagnet,
without economy resistor, the time constant increasing with the power.
Millions of operating cycles
1 million operating cycles
3 million operating cycles
10 million operating cycles
1
8
7
6
5
4
V
W
W
W
24
120
70
25
3
4
6
8 10
5
7
9
Current broken in A
48
90
50
18
125
75
38
14
250
68
33
12
440
61
28
10
24 V
48 V
125 V
3
250 V
2
1
0,8
0,7
0,6
0,5
440 V
0,4
0,3
0,2
0,1
0,1
0,2
0,3
0,4
0,5
References:
pages 2/17 and 2/18
2/40
Dimensions:
pages 2/44 and 2/45
0,6 0,8 1
0,7 0,9
2
Schemes:
pages 2/48 and 2/49
Schneider Electric
Characteristics
TeSys contactors
Control modules, coil suppressor modules
and mechanical latch blocks
for model d contactors
Environment
Conforming to standards
IEC 947-5-1
Product certifications
UL, CSA
Protective treatment
Conforming to IEC 68
“TH”
Degree of protection
Conforming to VDE 0106
Protection against direct finger contact IP 2X
Ambient air temperature
around the device
Storage
Operation
Permissible for operation at Uc
°C
°C
°C
- 40…+ 80
- 25…+ 55
- 25…+ 70
“Auto - Man - Stop” control modules
Recommendation
The Auto - Man selector switch must only be operated with the Start - Stop (“O” “I”) switch in position “O”
Rated insulation voltage
Conforming to EN 60947-5-1
V
250
Rated operational voltage
Conforming to EN 60947-5-1
V
250
Protection
Against electric shocks
kV
2
Built-in protection
Contactor coil suppression
By varistor
Indication
By integral LED
Illuminates when the contactor coil is energised
Electrical durability
In operating cycles
20,000
2
Coil suppressor modules
Module type
LA4-DA
LAD-4RC
LA4-DB
LAD-4T
LA4-DC
LA4-DE
LAD-4V
Type of protection
RC circuit
Bidirectional
peak limiting
diode
Diode
Varistor
"
24…415
" or $
24…72
$
12…250
" or $
24…250
3 Uc
2 Uc
Uc
2 Uc
400
200
100
150
–
–
–
–
–
–
–
–
–
Rated control circuit voltage (Uc)
V
Maximum peak voltage
Natural RC frequency
24/48 V
50/127 V
110/240 V
380/415 V
Hz
Hz
Hz
Hz
Mechanical latch blocks
Mechanical latch block type
For mounting on contactor
LA6-DK10
LC1D40…D65,
LP1-D65
LAD-6K10
LC1-D09…D38,
DT20…DT60
LA6-DK20
LC1-D80…D150
LP1-D80
and LC1-D115
Certification
UL, CSA
UL, CSA
Rated insulation voltage
Conforming to IEC 947-5-1
V
690
690
Rated control circuit voltage
" 50/60 Hz and $
V
24…415
24…415
Power required
For unlatching
VA
W
25
30
25
30
Maximum operating rate
On-load factor
Mechanical durability at Uc
In operating cycles/hour
References:
pages 2/18 to 2/21
Schneider Electric
"
$
1200
1200
10 %
10 %
In millions of operating cycles
0.5
0.5
Unlatching can be manually operated locally or electrically controlled for remote operation.
The LA6-DK or LAD-6K latch coil and the LC1-D operating coil must not be energised simultaneously. The duration of
the LA6-DK or LAD-6K and LC1-D control signals must be ≥ 100 ms.
Dimensions:
pages 2/44 and 2/45
Schemes:
pages 2/48 and 2/49
2/41
Characteristics
TeSys contactors
Electronic serial timer modules
for model d contactors
Module type
LA4-DT (On-delay)
LA4-DR (Off-delay) for LC1-D
Environment
Conforming to standards
Product certifications
Protective treatment
Degree of protection
2
IEC 255-5
UL, CSA
“TH”
Protection against direct finger contact IP 2X
Conforming to IEC 68
Conforming to VDE 0106
Ambient air temperature
around the device
Storage
Operation
For operation at Uc
°C
°C
°C
- 40…+ 80
- 25…+ 55
- 25…+ 70
Rated insulation voltage (Ui)
Conforming to EN 60947-5-1
V
250
Cabling
Phillips N° 2 and Ø 6 mm
Flexible or solid cable
with or without cable end
mm2 Min.: 1 x 1
Max.: 2 x 2.5
Control circuit characteristics
Built-in protection
On input
Suppression of contactor
By varistor
By varistor
By varistor
By bidirectional peak limiting diode
" or $ 24…250
" 24…250
Permissible variation
0.8…1.1 Uc
0.8…1.1 Uc
Type of control
By mechanical contact only
By mechanical contact only,
connecting cable < 10 m
0.1…2; 1.5…30; 25…500
0.1…2; 1.5…30; 25…500
± 3 % (10 ms minimum)
± 3 % (10 ms minimum)
Rated control circuit voltage (Uc)
V
Time delay characteristics
Timing ranges
s
Repeat accuracy
0…40 °C
Reset time
During the time delay period
After the time delay period
ms
ms
150
50
225
–
Immunity to micro-breaks
During the time delay period
After the time delay period
ms
ms
10
2
20
–
ms
–
40
Illuminates during time delay period
Illuminates during time delay period
Minimum control pulse duration
Indication of time delay
By LED
Switching characteristics (solid state type)
Maximum power dissipated
W
2
3.5
Leakage current
mA
<5
<5
Residual voltage
V
3.3
3.3
3 kV; 0.5 joule
3 kV; 0.5 joule
30
30
Overvoltage protection
Electrical durability
In millions of operating cycles
Operating diagrams
LA4-DT “On-delay” electronic timers
LA4-DR “Off-delay” electronic timers
U supply
(A1-A2)
U supply
(A1-A2)
1
0
Time delay output
Contactor coil
1
0
Control
(A2-B2)
t
Time delay output
Contactor coil
1
0
40 ms
1
0
1
0
t
Red LED
Red LED
References:
page 2/21
2/42
Dimensions:
pages 2/44 and 2/45
Schemes:
pages 2/48 and 2/49
Schneider Electric
Characteristics
TeSys contactors
Interface modules
for model d contactors
Environment
Conforming to standards
IEC 255-5
Product certifications
UL, CSA
Protective treatment
Conforming to IEC 68
“TH”
Degree of protection
Conforming to VDE 0106
Protection against direct finger contact IP 2X
Ambient air temperature
around the device
Storage
Operation
Permissible for operation at Uc
°C
°C
°C
- 40…+ 80
- 25…+ 55
- 25…+ 70
Other characteristics
Module type
LA4DFBQ
With
relay
LA4DFB
With
relay
LA4DFE
With
relay
LA4LA4DLB
DLE
With relay
+ override
LA4DWB
Solid
state
$ 48
$ 24
$ 24
Rated insulation voltage
Conforming to EN 60947-5-1
V
5
250
Rated operational voltage
Conforming to EN 60947-5-1
V
415
250
Indication of input state
By integral LED which illuminates when the contactor coil is energised
Input signals
Control voltage (E1-E2)
V
$ 24
$ 24
Permissible variation
V
17…30
17…30 33…60 17…30 33…60 5…30
Current consumption at 20 °C
mA
25
25
15
25
15
8.5 for 5 V
15 for 24 V
State “0” guaranteed for
U
V
< 2.4
< 2.4
< 4.8
< 2.4
< 4.8
< 2.4
I
mA
<2
<2
< 1.3
<2
< 1.3
<2
U
V
17
17
33
17
33
5
State “1” guaranteed for
$ 48
2
Built-in protection
Against reverse polarity
Of the input
By diode
By diode
Electrical durability at 220/240 V
In millions of operating cycles
3
10
10
3
3
20
ms
4
4
4
4
4
1
W
0.6
0.6
0.6
0.6
0.6
0.4
" 24…250 V
–
LC1-D40…D150
–
" 100…250 V
–
–
LC1-D40…D115
" 380…415 V
LC1-D40…D150 –
–
" 24…250 V
–
" 380…415 V
LC1-D09…D38,
DT20…DT60
LC1-D09…D38,
DT20…DT60
–
Maximum immunity time
to micro-breaks
Power dissipated
At 20 °C
Direct mounting without contactor
With coil:
Mounting with cabling adaptor
LAD-4BB
Total operating time
at Uc (of the contactor)
With coil:
Operating times depend on the type of contactor electromagnet and its control mode.
The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles.
The opening time “O” is measured from the moment the coil supply is switched off to the moment the main poles
separate.
With LA4-DF, DL
Cabling
References:
page 2/21
Schneider Electric
LC1-D09…D38,
DT20…DT60
–
Phillips N° 2 and Ø 6 mm
Flexible or solid cable
with or without cable end
Dimensions:
pages 2/44 and 2/45
N/O ms
N/C ms
LC1-D09…D38,
DT20…DT60
20…30
16…24
mm2
Min.: 1 x 1
mm2
Min.: 2 x 2.5
LC1-D40…D65
LC1-D80 and D95
28…34
20…24
28…43
18…32
Schemes:
pages 2/48 and 2/49
2/43