Typical Environmental Tests*
TEMPERATURE TESTS COMMERCIAL GRADE EXTENDED GRADE
High temperature storage
+70oC/3 days
+85oC/4 day
(IEC 68-2-2)
Low temperature storage
-25oC/3 days
(IEC 68-2-1)
-40oC/4 days
Temperature, cyclic
(IEC 68-2-14)
-25oC/30 min
+25oC/30 min
+70oC/30 min
+25oC/30 min
10 cycles
-40oC/30 min
+25oC/30 min
+85oC/30 min
+25oC/30 min
10 cycles
Damp heat, cyclic
(IEC 68-2-30)
25oC/95% RH/24h
40oC/93% RH/24h
6 cycles
25oC/95% RH/24h
40oC/93% RH/24h
21 cycles
Damp heat, steady state
(IEC 68-2-3)
40oC/93% RH
every 4 days
40oC/93% RH
every 21 days
* Expected lifetime under normal operating conditions
-- 50,000 hours (commercial) /100,000 hours (extended temperature).
These are minimum test. For other specifications, please consult VARITRONIX.
Mechanical Tests
Low air pressure
(IEC 68-2-13)
¡@
Vibration
(IEC 68-2-6)
frequency
cells must be mounted
ampitude
on a suitable connector
duration
Shock
(IEC 68-2-27)
Half-sine pulse shape
Bump
(IEC 68-2-29)
pulse duration
peak acceleration
number of shocks
pulse duration
peak acceleration
number of shocks
25oC/86 to 106Pa
10 to 55 Hz
0.75 mm
20 cycles in each
direction
11 ms
2
981 m/s = 100g
3 shocks in 3 mutually
perpendicular axes
6 ms
392 m/s2
1000±10