ACDC 50100 Watts VCS Series xppower.com • Chassis Mount Industrial Supplies • 25 °C to +70 °C Convection Cooled • Class B Conducted & Radiated Emissions • Output Voltages from 5 V to 48 V • <0.5 W No Load Input Power • Low Cost • 2 Year Warranty Specification Input • 85-264 VAC (127-370 VDC), see derating curve Input Frequency • 47-63 Hz Input Current • VCS50: 1.1 A, VCS70: 1.4 A, VCS100: 2.0 A typical at 90 VAC Inrush Current • 60 A max at 230 VAC, cold start at 25 °C Power Factor • EN61000-3-2 Class A Earth Leakage Current • 1.0 mA maximum Input Protection • 50 & 70 W: T3.15 A/250 V 100 W: T4.0A/250 V, fuse fitted in live line No Load Input Power • <0.5 W Input Voltage Output • See model table • ±10.0% (5 V & 12 V versions are -5% to +10%) Initial Set Tolerance • ±1.0% Minimum Load • None required Start Up Delay • 1 s maximum Hold Up Time • 10 ms min at 115 VAC and full load Line Regulation • ±0.5%, 90 VAC to 264 VAC input Load Regulation • 5 V & 12 V versions: ±1%, Others: ±0.5% 0% to 100% load Transient Response • Less than 4% deviation with a 50% to 75% load change at 1 A/µs. Output returns to within 1% in less than 500 µs Ripple & Noise • 1% maximum pk-pk, 20 MHz bandwidth Overvoltage Protection • 120-140% of nominal output, auto recovery Overload Protection • 110-150% of nominal, trip and restart Short Circuit Protection • Continuous trip and restart Temperature • ±0.03%/°C after 20 min warm up Coefficient Output Voltage Output Adjust General Efficiency Isolation Switching Frequency MTBF • See tables • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground • 65 kHz typical • >500 kHrs to MIL-STD-217F at 25 °C, GB Environmental Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Shock Vibration • • • • • • -25 °C to +70 °C, see derating curve Convection cooled 0-95% R.H, non-condensing -40 °C to +80 °C 3000 m ±3 x 30 g shocks in each plane, 30 g: 11 ms (±0.5 ms), half sine, compliant to EN60068-2-27 & EN60068-2-47 • 10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6 EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals • • • • • • EN55022 Class B conducted & radiated EN61000-3-2 class A EN61000-3-3 EN61000-4-2, level 3 Perf Criteria A EN61000-4-3, level 3 Perf Criteria A EN61000-4-4, level 3 Perf Criteria A (note 3) • EN61000-4-5, installation Class 3, Perf Criteria A • EN61000-4-6, level 3 Perf Criteria A • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B • IEC60950-1, CSA C22.2 No.60950-1-03, UL60950-1, TUV EN60950-1 Output Power Output Voltage Output Current 40 W 5.0 V 8.00 A 50 mV 79% VCS50US05†^ 12.0 V 4.20 A 120 mV 85% VCS50US12†^ 15.0 V 3.30 A 150 mV 86% VCS50US15†^ 24.0 V 2.10 A 240 mV 88% VCS50US24†^ 48.0 V 1.05 A 480 mV 88% VCS50US48†^ 50 W Ripple & Noise(2) Efficiency(1) Model Number Notes 1. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. 2. Ripple & Noise may exceed specified values below -10 °C. 3. Level 3 performance criteria A is met for loads >2%. At no load, result is performance criteria A Level 2 or less than 4% output deviation at Level 3. † Available from Farnell & element14. See pages 284-290. ^ Available from Newark. See pages 291-296. Mechanical Details 1 3.07 (78.0) M3 4 locations 2 3 0.75 (19.0) 4 5 1.14 (29.0) 1.18 (30.0) 0.59 (15.0) 1.69 (43.0) 4.35 (110.5) Pin 1 2 3 4 5 3.82 (97.0) 0.157 (4.0) 0.43 (11.0) Notes 0.14 (3.5) 0.47 (12.0) 1.38 (35.0) 1. All dimensions in inches (mm) 2. Weight: 0.55 lbs (250 g) approx 3. Tolerance ±0.02 (±0.5) 4. Maximum mounting screw penetration 0.157 (4.0) from outer surface 0.41 (10.5) M3 3 locations 0.70 (17.7) Function AC Live AC Neutral Ground -Vout +Vout 0.98 (25.0) 100 100 80 80 Output Power (%) Output Power (%) Derating Curves 60 40 20 -25 -10 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 60 40 20 85 90 100 110 120 230 Input Voltage (VAC) 240 250 264 ACDC VCS50 Model and Ratings Output Power Output Voltage 50 W 70 W Output Current Ripple & Noise(2) Efficiency(1) Model Number 5.0 V 10.0 A 50 mV 80% VCS70US05†^ 12.0 V 5.83 A 120 mV 87% VCS70US12†^ 15.0 V 4.67 A 150 mV 87% VCS70US15†^ 24.0 V 2.92 A 240 mV 87% VCS70US24†^ 48.0 V 1.46 A 480 mV 87% VCS70US48†^ Notes 1. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. 2. Ripple & Noise may exceed specified values below -10 ˚C. 3. For all loads. † Available from Farnell & element14. See pages 284-290. ^ Available from Newark. See pages 291-296. Mechanical Details 0.14 (3.5) 0.2 (5.1) 1 2 3 3.88 (98.5) 4 1.26 (32.0) 3.55 (90.1) 5 M3 2 locations 1.36 (34.5) 3.08 (78.3) 0.22 (5.5) 0.20 (5.0) Ø 0.13 (3.3) 0.75 (19.0) 1.61 (41.0) 0.80 (20.3) 0.14 (3.5) 1.21 (30.8) 1.18 (30.0) 3.07 (78.0) 0.20 (5.2) Function AC Live AC Neutral Ground -Vout +Vout Notes 0.43 (11.0) 1.28 (32.4) Pin 1 2 3 4 5 0.22 (5.5) Ø 0.13 (3.3) 5.12 (130.0) 1. All dimensions in inches (mm) 2. Weight: 0.88 lbs (400 g) approx 3. Tolerance ±0.02 (±0.5) 4. Maximum mounting screw penetration 0.157 (4.0) from outer surface M3 3 locations Derating Curves 100 100 80 80 Output Power (%) Output Power (%) ACDC VCS70 Model and Ratings 60 40 20 -25 -10 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 60 40 20 85 90 100 110 120 230 Input Voltage (VAC) 240 250 264 Output Power Output Voltage Output Current 70 W 5.0 V 14.0 A 12.0 V 100 W ACDC VCS100 Model and Ratings Ripple & Noise(2) Efficiency(1) Model Number 50 mV 78.0% VCS100US05†^ 8.33 A 120 mV 85.0% VCS100US12†^ 15.0 V 6.67 A 150 mV 86.0% VCS100US15†^ 24.0 V 4.17 A 240 mV 86.5% VCS100US24†^ 48.0 V 2.08 A 480 mV 88.0% VCS100US48†^ Notes 1. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load. 2. Ripple & Noise may exceed specified values below -10 ˚C. 3. Level 3 performance criteria A is met for loads >10%. At no load, result is performance criteria A at Level 2 or less than 5% output deviation at Level 3. † Available from Farnell & element14. See pages 284-290. ^ Available from Newark. See pages 291-296. Mechanical Details 0.20 (5.0) 0.16 (4.0) 1 M3 4 locations 2 3 3.87 (98.2) 1.26 (32.0) 3.52 (89.5) 4 5 6 7 1.30 (33.0) 0.90 (24.0) 3.07 (78.0) 0.2 (5.0) 6.26 (159.0) 0.24 (6.0) Pin 1 2 3 4 5 6 7 0.19 (4.8) 0.16 (4.0) Ø0.13 (3.3) 1.65 (42.0) 0.87 (22.2) 0.71 (18.0) Notes 100 100 80 80 Output Power (%) Output Power (%) Derating Curves 60 40 20 -10 0 Function AC Live AC Neutral Ground -Vout -Vout +Vout +Vout 1. All dimensions in inches (mm) 2. Weight: 1.1 lbs (500 g) approx 3. Tolerance ±0.02 (±0.5) 4. Maximum mounting screw penetration 0.157 (4.0) from outer surface 0.37 (9.3) 5.49 (139.5) 1.08 (27.5) -25 0.16 (4.0) 1.02 (26.0) M3 3 locations 0.74 (18.8) 0.24 (6.0) 10 20 30 40 50 Ambient Temperature (°C) 60 70 60 40 20 85 90 100 110 120 230 240 250 264 Input Voltage (VAC) 19-July-12