AIMTEC AM12T-Z_13

Series AM12T-Z
12 Watt | DC-DC Converter
FEATURES:





Wide Input Range 2:1
1600 Vdc Isolation
Efficiency up to 91%
Soft Start
Remote On/Off Function





No Minimum Load Required
-40ºC to +85ºC Operating Temperature Range
Short Circuit & Over Voltage Protection
DIP 24 Package
Low No Load Input Current
Models
Single output
Model
Input
Voltage
(V)
AM12T-1202SZ
AM12T-1203SZ
AM12T-1205SZ
AM12T-1212SZ
AM12T-1215SZ
AM12T-2402SZ
AM12T-2403SZ
AM12T-2405SZ
AM12T-2412SZ
AM12T-2415SZ
AM12T-4802SZ
AM12T-4803SZ
AM12T-4805SZ
AM12T-4812SZ
AM12T-4815SZ
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
Output
Voltage
(V)
Output
Current max
(mA)
Isolation
(VDC)
Maximum
Capacitive load
(µF)
Efficiency
(%)
3500
3500
2400
1000
800
3500
3500
2400
1000
800
3500
3500
2400
1000
800
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
2000
2000
2000
430
300
2000
2000
2000
430
300
2000
2000
2000
430
300
85
87
89
90
90
85
87
89
90
90
84
88
89
88
89
2.5
3.3
5
12
15
2.5
3.3
5
12
15
2.5
3.3
5
12
15
Models
Dual output
Model
Input
Voltage
(V)
Output
Voltage
(V)
Output
Current max
(mA)
Isolation
(VDC)
Maximum
Capacitive load
(µF)
Efficiency
(%)
AM12T-1212DZ
AM12T-1215DZ
AM12T-2412DZ
AM12T-2415DZ
AM12T-4812DZ
AM12T-4815DZ
9-18
9-18
18-36
18-36
36-75
36-75
±12
±15
±12
±15
±12
±15
±500
±400
±500
±400
±500
±400
1600
1600
1600
1600
1600
1600
±200
±120
±200
±120
±200
±120
90
91
90
91
88
89
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load unless otherwise specified
Input Specifications
Parameters
Voltage range
Filter
Turn on Transient process time
Transient response deviation
Start up time
Absolute Maximum Rating
www.aimtec.com
F 051e R12.F
Nominal
Typical
12
24
48
Maximum
9-18
18-36
36-48
π (Pi) Network
250
VDC
±3
Nominal Vin and constant resistive load
12 Vin models
24 Vin models
48 Vin models
Tel: +1 514 620 2722
1 of 3
20
-0.7-36
-0.7-50
-0.7-100
Units
µs
%
ms
VDC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM12T-Z
12 Watt | DC-DC Converter
Input Specifications (continued)
Parameters
Nominal
Peak Input Voltage time
Input reflected ripple current
Quiescent Current
Typical
Maximum
Units
1000
20
ms
mA p-p
mA
15
ON – High (3.0 ... 12Vdc) or open circuit;
OFF – Low (0 ... 1.2Vdc) or Short circuit pin1 and pin 2/3
OFF idle current: 5.0 mA typ
On/Off Control
Isolation Specifications
Parameters
Tested I/O voltage
Tested Case/Input and Output
Resistance
Capacitance
Conditions
Typical
3 sec
Rated
Units
1600
VDC
VDC
MOhm
pF
Maximum
Units
1600
>1000
1200
Output Specifications
Parameters
Voltage accuracy
Voltage balance
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Ripple & Noise
Conditions
Typical
±1.2
±5
±0.5
±0.5
±1.0
Zener diode clamp
150
Continuous
Auto recovery
85
Dual output
HL-LL
0% Load to Full Load
0% Load to Full Load
Full Load
%
%
%
%
%
%
m Vp-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Temperature coefficient
Derating
Cooling
Humidity
Case material
Potting material
Weight
Dimensions (L x W x H)
MTBF
Conditions
Typical
100% load
Full Load with Derating above 60ºC
330
Maximum
-40 to +85
-40 to +125
100
±0.02
2.5 % per 1ºC
Free air convection
Above 60ºC
Units
KHz
o
C
o
C
o
C
%/oC
95
% RH
Nickel-coated Copper
UL94V-0 rated
18.0
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm
>1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Agency Approval
Standards
www.aimtec.com
F 051e R12.F
CE
nd
IEC 60950-1:2005 (2 Edition); EN 60950-1: 2006
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM12T-Z
12 Watt | DC-DC Converter
Pin Out Specifications
Derating
Pin
Single
Dual
1
2
3
9
11
14
16
22
23
Remote On/Off
-V Input
-V Input
No Pin
N.C.
+V Output
-V Output
+V Input
+V Input
Remote On/Off
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
Dimensions
Test Circuits
Conducted Emmisions :
Surge:
+Vout
+Vout
L
12uH
+Vin
+Vin
DC/DC
Converter
C1
100uF, 100V
-Vin
Load
DC/DC
Converter
C1
330uF, 100V
-Vin
-Vout
Load
-Vout
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.F
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only