AIMTEC AM8TW

Series AM8TW-Z
8Watt | DC-DC Converter
FEATURES:
•
•
•
•
Models
Single output
Model
Input Voltage
(V)
AM8TW-2403SZ
AM8TW-2405SZ
AM8TW-2412SZ
AM8TW-2415SZ
AM8TW-4803SZ
AM8TW-4805SZ
AM8TW-4812SZ
AM8TW-4815SZ
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
Models
Dual output
Model
Input Voltage
(V)
AM8TW-2405DZ
AM8TW-2412DZ
AM8TW-2415DZ
AM8TW-4805DZ
AM8TW-4812DZ
AM8TW-4815DZ
9-36
9-36
9-36
18-75
18-75
18-75
Wide 4:1 input range
24 Pin DIP Package
High efficiency up to 87%
Over Voltage/Overload Protection
•
•
•
•
Operating temperature -40oC to + 85oC
Input / Output Isolation 1600 VDC
Continuous short circuit protection
RoHS compliant
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
3.3
5
12
15
3.3
5
12
15
2000
1500
665
535
2000
1500
665
535
1600
1600
1600
1600
1600
1600
1600
1600
Output
Voltage
(V)
Output Current
max (mA)
Isolation
(VDC)
±5
±12
±15
±5
±12
±15
±800
±335
±265
±800
±335
±265
1600
1600
1600
1600
1600
1600
Max
Capacitive
Load(uF)
Efficiency
(%)
1330
1330
288
200
1330
1330
288
200
83
86
87
87
82
86
87
87
Max
Capacitive
Load(uF)
Efficiency
(%)
±900
±133
±90
±900
±133
±90
84
86
87
84
87
87
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Filter
Start up time
Absolute Maximum Rating
Peak Input Voltage time
Nominal
24
48
24
48
On/Off control
No Load Input Current
Input reflected current
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R12.E
Conditions
3 sec
Typical
9-36
18-75
π (Pi) Network
20
Maximum
Units
VDC
-0.7-50
-0.7-100
100
ON – 3.0 ~ 12VDC (or open)
OFF -0~1.2VDC (or short between pin 1 and 2/3)
15
20
Typical
>1000
1500
Tel: +1 514 620 2722
1 of 4
Rated
1600
ms
VDC
ms
mA
mAp-p
Units
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM8TW-Z
8Watt | DC-DC Converter
Output Specifications
Parameters
Voltage accuracy
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
Ripple & Noise
Minimum Load Current
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Transient recovery time
Transient recovery deviation
Conditions
Typical
Zener Diode Clamp
150
Continuous
Auto-Recovery
±0.2
±0.5
±1
±0.02
75
0
HL-LL
0 – 100% load
0 – 100% load
20MHz Bandwidth
Conditions
100% load
Derating above +70
Maximum
±1
Typical
270
-40 to +125
%
%
%
% of Vin
%
%
%/oC
mV p-p
% of Max
Maximum
Units
KHz
o
C
o
C
o
C
-40 to +85
Free air convection
Units
105
95
Nickel plated Cooper
18
1.25 x 0.80 x 0.12 inches
31.80 x 20.30 x 10.20 mm
> 1,000,100 hours(MIL-HDBK-217F , Ground Benign, t=+25oC)
1.5mm from case for 10sec
260
250
±3
% RH
g
o
C
uS
%
Safety Specifications
Parameters
Agency Approval
Standards
www.aimtec.com
F 051e R12.E
CE
EN55022 Class A, EN55024
IEC61000-4-2, Perf. Criteria B
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
Tel: +1 514 620 2722
2 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM8TW-Z
8Watt | DC-DC Converter
Pin Out Specifications
Pin
1
2
3
9
11
14
16
22
23
Single
Remote On/Off
-V Input
-V Input
No Pin
N.C.
+V Output
-V Output
+V Input
+V Input
N.C.: Not Connected
Dimensions
Dual
Remote On/Off
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
Derating
70 ºC
Output Power (%)
100
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
40
60
80
85
100
Ambient Temperature º C
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM8TW-Z
8Watt | DC-DC Converter
Recommended Circuits
Conducted Emissions
+Vout
L
C1
+Vin
DC/DC
Converter
C2
-Vin
C1
2.2uF, 100V
L
12uH
Load
-Vout
C2
2.2uF, 100V
Surge/EFT
+Vin
+Vout
DC/DC
Converter
C1
Load
-Vin
-Vout
C1
330uF, 100V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R12.E
Tel: +1 514 620 2722
4 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only