Series AM1DR-RZ 1 Watt | DC-DC Converter FEATURES: Regulated Single Output Continuous Short Circuit Protection RoHS Compliant MTBF>1,500,000 hours 1000VDC Isolation Operating temperature: -40°C to +85°C Industry Standard Pinout SIP7 Package Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Max Capacitive Load (uF) Isolation (VDC) Efficiency (%) AM1DR-0503S-RZ 4.5-5.5 3.3 303 1000 220 55 AM1DR-0505S-RZ 4.5-5.5 5 200 1000 220 64 AM1DR-0507S-RZ 4.5-5.5 7.2 139 1000 220 64 AM1DR-0509S-RZ 4.5-5.5 9 111 1000 220 65 AM1DR-0512S-RZ 4.5-5.5 12 83 1000 220 66 AM1DR-0515S-RZ 4.5-5.5 15 67 1000 220 66 AM1DR-1203S-RZ 10.8-13.2 3.3 303 1000 220 56 AM1DR-1205S-RZ 10.8-13.2 5 200 1000 220 64 AM1DR-1207S-RZ 10.8-13.2 7.2 139 1000 220 65 AM1DR-1209S-RZ 10.8-13.2 9 111 1000 220 66 AM1DR-1212S-RZ 10.8-13.2 12 83 1000 220 66 AM1DR-1215S-RZ 10.8-13.2 15 67 1000 220 68 AM1DR-2403S-RZ 21.6- 26.4 3.3 303 1000 220 56 AM1DR-2405S-RZ 21.6- 26.4 5 200 1000 220 63 AM1DR-2407S-RZ 21.6- 26.4 7.2 139 1000 220 65 AM1DR-2409S-RZ 21.6- 26.4 9 111 1000 220 66 AM1DR-2412S-RZ 21.6- 26.4 12 83 1000 220 67 AM1DR-2415S-RZ 21.6- 26.4 15 67 1000 220 67 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal 5 12 24 Filter Absolute Maximum Rating (100 ms) Typical Maximum Units 4.5- 5.5 10.8-13.2 21.6- 26.4 Capacitor VDC 5 12 24 7 15 28 45 No load input current Input reflected ripple current VDC mA mA p-p 20 Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Conditions Typical 3 sec At 500VDC Rated Units 1000 VDC MOhm pF >1000 60 Output Specifications Parameters Voltage accuracy Short Circuit protection Short circuit restart Line voltage regulation www.aimtec.com F 051e R9.E Conditions Typical ±2 Continuous Auto-Recovery ±0.5 LL ~ HL Tel: +1 514 620 2722 1 of 3 Maximum Units % % of Vin Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1DR-RZ 1 Watt | DC-DC Converter Output Specifications (continued) Parameters Conditions Load voltage regulation Load voltage regulation (3.3V output) Temperature coefficient Ripple & Noise Typical From 0% to 100% Load From 0% to 100% Load Maximum ±0.5 ±1 ±0.02 50 20MHz Bandwidth Units % % %/oC mV p-p General Specifications Parameters Conditions Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Typical Maximum Units 50 (variable) Full load KHz o C o C o C -40 to +85 -40 to +125 100 Free Air Convection 95 Non-Conductive Plastic (UL94V-0) 2.7 19.50 x 7.20 x 9.50 mm (0.77 x 0.28 x 0.37 inches) >1,500,000 hrs dual (MIL-HDBK -217F, Ground Benign, t=+25oC) 1.5mm from case for 10 sec 260 % RH g o C Safety Specifications Parameters Agency Approvals Safety Standards CE EN 55022, Class B IEC61000-4-2 IEC61000-4-3 IEC61000-4-4 IEC61000-4-6 IEC61000-4-8 Also designed to meet IEC 60950-1 Pin Out Specifications Pin 1 2 4 5 6 7 Single + V input - V input - V output No Pin + V output No Pin Dimensions 19.50 (0.78) 7.20 (0.28) PRINTED FACE 9.50 (0.37) 9.50 (0.37) 0.50 (0.02) 3.05 (0.12) 2.54 (0.10) 0.50 (0.02) 7.20 (0.28) 0.25 (0.01) 0.50 (0.02) 1.25 (0.05) www.aimtec.com F 051e R9.E Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM1DR-RZ 1 Watt | DC-DC Converter Radiated and Conducted Emissions Application circuit: C1 L1 470µF/100V 12 µH NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R9.E Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only