AIMTEC AM5TW

Series AM5TW-RVZ
5 Watt | DC-DC Converter
FEATURES:
 Wide Input Range (4:1)
 24 Pin DIP Package
 Metal package
 High efficiency up to 82%
Models
Single output
Model
Operating temperature -40oC to + 85oC
Input / Output isolation 1500 VDC
Pin compatible with multiple manufacturers
Continuous short circuit protection




Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
Capacitive load,
max (μF)
Efficiency
(%)
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
3.3
5
12
15
3.3
5
12
15
1200
1000
416
333
1200
1000
416
333
2200
1000
470
330
2200
1000
470
330
70
73
74
74
68
73
74
76
Input Voltage
(V)
Output Voltage
(V)
9-36
9-36
9-36
18-72
18-72
18-72
±5
±12
±15
±5
±12
±15
AM5TW-2403S-RVZ
AM5TW-2405S-RVZ
AM5TW-2412S-RVZ
AM5TW-2415S-RVZ
AM5TW-4803S-RVZ
AM5TW-4805S-RVZ
AM5TW-4812S-RVZ
AM5TW-4815S-RVZ
Models
Dual output
Model
AM5TW-2405D-RVZ
AM5TW-2412D-RVZ
AM5TW-2415D-RVZ
AM5TW-4805D-RVZ
AM5TW-4812D-RVZ
AM5TW-4815D-RVZ
Output Current
max (mA)
±500
±208
±166
±500
±208
±166
Capacitive load,
max (μF)
Efficiency
(%)
±470
±100
±68
±470
±100
±68
77
82
82
72
75
75
Maximum
Units
Input Specifications
Parameters
Voltage Range
Filter
Start up time
Peak Input Voltage time
Absolute Max Rating
Nominal
Typical
24
48
9-36
18-72
24 Vin
20
15
-0.7-40
VDC
 (Pi) Network
Ms
Ms
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
Typical
3 sec
Rated
Units
1500
VDC
MOhm
pF
> 1000
60
Output Specifications
Parameters
Voltage Balance
Voltage accuracy
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
www.aimtec.com
F 051e R13.B
Conditions
Typical
Balanced Load
±1
±1
Maximum
Units
%
%
Continuous
Auto Recovery
At 20MHz Bandwidth
±0.5
±0.5
±0.02
60
Tel: +1 514 620 2722
1 of 3
%
%
%/oC
mV p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5TW-RVZ
5 Watt | DC-DC Converter
General Specifications
Parameters
Conditions
Typical
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions(L x W x H)
MTBF
100% load
Full Load (see derating chart)
100-400
Maximum
Units
100
KHz
o
C
o
C
o
C
-40 to +85
-40 to +125
Free air convection
95
%
Nickel coated copper
15
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.8 x 0.4 inches
31.75 x 20.32 x 10.16 mm
>2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Pin
2
3
9
11
14
16
22
23
1500 VDC
Single
Dual
-V Input
-V Input
No pin
N.C.
+V Output
-V Output
+V Input
+V Input
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM5TW-RVZ
5 Watt | DC-DC Converter
3.05
(0.12)
10.16
(0.40)
20.32
(0.80)
15.24
(0.60)
Dimensions
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only