Series AM5E-FZ 5 Watt | DC-DC Converter FEATURES: • • • • Models Single output Model AM5E-1203S-FZ AM5E-1205S-FZ AM5E-1212S-FZ AM5E-1215S-FZ AM5E-2403S-FZ AM5E-2405S-FZ AM5E-2412S-FZ AM5E-2415S-FZ AM5E-4803S-FZ AM5E-4805S-FZ AM5E-4812S-FZ AM5E-4815S-FZ Input Voltage (V) 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 36-72 36-72 36-72 36-72 Models Dual output Model Input Voltage (V) Over Load, Over Voltage Protection Wide 2:1 input range High efficiency up to 87% Pin compatible with multiple manufacturers • Operating temperature -55oC to + 85oC • Input / Output Isolation 1500 VDC • Continuous short circuit protection Output Voltage (V) Minimum Load Current (mA) Output Current max (A) Capacitance load, max (μF) Efficiency (%) 20 0 0 0 20 0 0 0 20 0 0 0 1.5 1.0 0.416 0.333 1.5 1.0 0.416 0.333 1.5 1.0 0.416 0.333 4700 2200 330 220 4700 2200 330 220 4700 2200 330 220 78 80 85 85 79 82 86 87 77 82 85 86 Output Voltage (V) Minimum Load Current (mA) Output Current max (A) Capacitance load, max (μF) Efficiency (%) 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 AM5E-1205D-FZ 9-18 ±5 57 ±0.5 1100 82 AM5E-1212D-FZ 9-18 ±12 0 ±0.208 100 84 AM5E-1215D-FZ 9-18 ±15 0 ±0.167 69 85 AM5E-2405D-FZ 18-36 ±5 57 ±0.5 990 83 AM5E-2412D-FZ 18-36 ±12 0 ±0.208 122 86 AM5E-2415D-FZ 18-36 ±15 0 ±0.167 147 87 AM5E-4805D-FZ 36-72 ±5 57 ±0.5 1000 82 AM5E-4812D-FZ 36-72 ±12 0 ±0.208 220 86 AM5E-4815D-FZ 36-72 ±15 0 ±0.167 13 86 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. www.aimtec.com F 051e R12 Tel: +1 514 620 2722 1 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM5E-FZ Input Specifications Parameters Voltage range Filter Start up time Absolute Maximum Rating Peak Input Voltage time No Load Input Current Input reflected current Transient recovery deviation Transient response time Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance Output Specifications Parameters Voltage accuracy Short Circuit protection Short circuit restart Over load protection Over Voltage Protection Line voltage regulation Load voltage regulation (Single) Load voltage regulation (Dual) Temperature coefficient Ripple & Noise General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature www.aimtec.com F 051e R12 5 Watt | DC-DC Converter Nominal Typical 12 24 48 Maximum 9-18 18-36 36-72 VDC π(PI ) 400 -0.7-25 -0.7-50 -0.7-100 12 Vin 24 Vin 48 Vin ms VDC 100 <3 250 ±5 300 50% load step change Conditions Typical 3 sec Rated > 1000 580 24 Vin Conditions Typical ±1 20MHz Bandwidth Conditions 300 -55 to +125 Units VDC MOhm pF Maximum Units 150 Zener Diode Clamp ±0.5 ±0.5 ±0.5 ±5 ±0.02 75 Typical ms mA mAp-p %of Vout µs 1500 Continuous Auto Recovery LL-HL 25-100% 10-100% Balanced 25-100% Unbalanced Units % % % % % % oC mVp-p Maximum -55 to +85 100 Units KHz o C o C o C Free air convection 95 % Nickel coated copper 30 g Tolerance ±0.5mm 2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.20 mm >1,960,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) o 1.5mm from case max 10 sec 260 C Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM5E-FZ 5 Watt | DC-DC Converter Pin Out Specifications Pin Single 1 2 3 4 5 +V Input -V Input +V Output No Pin. -V Output Dual +V Input -V Input +V Output Common. -V Output 2.54 (0.10) Dimensions 50.80 (2.00) 20.32 (0.80) 15.24 (0.60) 10.16 (0.40) Notes: All dimensions are typical in millimeters (inches). Tolerance ±0.25 (±0.01) 5.08 (0.20) Min 10.20 (0.40) DIA 1.00 (0.04) 5 15.24 (0.60) Built-in Stand-offs to ease PCB cleaning 4 10.16 (0.40) 10.16 (0.40) 2 Bottom View 2.54 (0.10) 1 5.08 (0.20) 25.40 (1.00) 10.16 (0.40) 3 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12 Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only