AVAGO AFCT

AFCT-701ASDZ
10Gb Ethernet, 1310 nm, 10GBASE-LR,
SFP+ Transceiver for SMF 10km links
Case temperature 0-85 qC
Data Sheet
Description
The Avago AFCT-701ASDZ transceiver is part of a family of SFP+ products. This transceiver utilizes Avago’s
1310nm DFB and PIN Detector technology to provide an
IEEE 10Gb Ethernet design compliant with the 10GBASELR standard. The AFCT-701ASDZ transceiver is designed
with an extended case temperature to 0-85 qC to enable 10Gb Ethernet equipment designs with very high
port density based on the new electrical and mechanical specification enhancements to the well known SFP
specifications developed by the SFF Committee. These
specifications are referred to as SFP+ to recognize these
enhancements to previous SFP specifications used for
lower speed products. Avago Technologies is an active
participant in the SFF Committee specification development activities.
Related Products
x AFCT-701SDZ SFP+ 10 Gigabit Ethernet 10GBASE-LR
transceiver with case temperature operated at 0-70
qC for operation in SMF link applications to 10 km
x AFBR-707SDZ SFP+ 10 Gigabit Ethernet 10GBASELRM transceiver for 220 meter operation in all MMF
link applications including OM1 and OM2 legacy fiber
cables and new high bandwidth OM3 fiber cables.
x The AFBR-703SDZ (AFBR-703ASDZ) with case
temperature 0-70 (0-85) °C is an SFP+ 10 Gigabit
Ethernet 10GBASE-SR transceiver for use on
multimode fiber cables. It is best suited for OM3 high
bandwidth MMF link applications with link lengths up
to 300 meters.
x AFCT-5016Z SFP+ Evaluation Board The purpose of
this SFP+ evaluation board is to provide the designer
with a convenient means for evaluating SFP+ fiber
optic transceivers.
Features
x Avago 1310nm DFB source and Transmitter Optical
Subassembly technology
x Avago PIN detector and Receiver Optical Subassembly
technology
x Typical power dissipation 850mW
x Extended case temperature 0-85 qC
x Full digital diagnostic management interface
x Avago SFP+ package design enables equipment EMI
performance in high port density applications with
margin to Class B limits
Specifications
x Optical interface specifications per IEEE 802.3ae
10GBASE-LR
x Electrical interface specifications per SFF Committee
SFF 8431 Specifications for Enhanced 8.5 and 10
Gigabit Small Form Factor Pluggable Module “SFP+”
x Management interface specifications per SFF
Committee SFF 8431 and SFF 8472 Diagnostic
Monitoring Interface for Optical Transceivers
x Mechanical specifications per SFF Committee SFF
8432 Improved Pluggable Formfactor “IPF”
x LC Duplex optical connector interface confirming to
ANSI TIA/EA 604-10 (FOCIS 10A)
x Compliant to Restriction on Hazardous Substances
(RoHS) per EU and China requirements
x Class 1 Eye safe per requirements of IEC 60825-1 /
CDRH
Description, continued
Installation
Compliance Prediction
The AFCT-701ASDZ transceiver package is compliant
with the SFF 8432 Improved Pluggable Formfactor housing specification for the SFP+. It can be installed in any
INF-8074 or SFF-8431/2 compliant Small Form Pluggable
(SFP) port regardless of host equipment operating status
The AFCT-701ASDZ is hot-pluggable, allowing the module to be installed while the host system is operating and
on-line. Upon insertion, the transceiver housing makes
initial contact with the host board SFP cage, mitigating
potential damage due to Electro-Static Discharge (ESD).
Compliance prediction is the ability to determine if an
optical transceiver is operating within its operating and
environmental requirements. AFCT-701ASDZ devices
provide real-time access to transceiver internal supply
voltage and temperature, allowing a host to identify potential component compliance issues. Received optical
power is also available to assess compliance of a cable
plant and remote transmitter. When operating out of requirements, the link cannot guarantee error free transmission.
Digital Diagnostic Interface and Serial Identification
Fault Isolation
The two-wire interface protocol and signaling detail
are based on SFF-8431. Conventional EEPROM memory, bytes 0-255 at memory address 0xA0, is organized
in compliance with SFF-8431. New digital diagnostic
information, bytes 0-255 at memory address 0xA2, is
compliant to SFF-8472. The new diagnostic information
provides the opportunity for Predictive Failure Identification, Compliance Prediction, Fault Isolation and Component Monitoring.
The fault isolation feature allows a host to quickly pinpoint the location of a link failure, minimizing downtime.
For optical links, the ability to identify a fault at a local
device, remote device or cable plant is crucial to speeding service of an installation. AFCT-701ASDZ real-time
monitors of Tx_Bias, Tx_Power, Vcc, Temperature and
Rx_Power can be used to assess local transceiver current
operating conditions. In addition, status flags TX_DISABLE and Rx Loss of Signal (LOS) are mirrored in memory
and available via the two-wire serial interface.
Predictive Failure Identification
The AFCT-701ASDZ predictive failure feature allows a
host to identify potential link problems before system
performance is impacted. Prior identification of link
problems enables a host to service an application via
“fail over” to a redundant link or replace a suspect device,
maintaining system uptime in the process. For applications where ultra-high system uptime is required, a digital SFP provides a means to monitor two real-time laser
metrics associated with observing laser degradation and
predicting failure: average laser bias current (Tx_Bias)
and average laser optical power (Tx_Power).
2
Component Monitoring
Component evaluation is a more casual use of the AFCT701ASDZ real-time monitors of Tx_Bias, Tx_Power, Vcc,
Temperature and Rx_Power. Potential uses are as debugging aids for system installation and design, and transceiver parametric evaluation for factory or field qualification. For example, temperature per module can be
observed in high density applications to facilitate thermal evaluation of blades, PCI cards and systems.
OPTICAL INTERFACE
ELECTRICAL INTERFACE
RECEIVER
LIGHT FROM FIBER
RD+ (RECEIVE DATA)
AMPLIFICATION
& QUANTIZATION
PHOTO-DETECTOR
RD– (RECEIVE DATA)
RX_LOS
RS0
RS1
CONTROLLER & MEMORY
SDA
SCL
MOD-ABS
TRANSMITTER
LIGHT TO FIBER
TX_DISABLE
DFB
LASER
DRIVER &
SAFETY
CIRCUITRY
TD+ (TRANSMIT DATA)
TD– (TRANSMIT DATA)
TX_FAULT
Figure 1. Transceiver functional diagram
Transmitter Section
Transmit Fault (TX_FAULT)
The transmitter section includes the Transmitter Optical Sub-Assembly (TOSA) and laser driver circuitry. The
TOSA, containing an Avago designed and manufactured
1310 nm DFB light source, is located at the optical interface and mates with the LC optical connector. The TOSA
is driven by an IC which uses the incoming differential
high speed logic signal to modulate the laser diode driver current. This Tx laser driver circuit regulates the optical
power at a level within the specified range.
A catastrophic laser fault will activate the transmitter
signal, TX_FAULT, and disable the laser. This signal is
an open collector output (pull-up required on the host
board). A low signal indicates normal laser operation and
a high signal indicates a fault. A fault is defined as laser
power below or above the specified IEEE 802.3ae specified min/max range. The TX_FAULT will be latched high
when a laser fault occurs and is cleared by toggling the
TX_DISABLE input or power cycling the transceiver. The
transmitter fault condition can also be monitored via the
two-wire serial interface (address A2, byte 110, bit 2).
Transmit Disable (TX_DISABLE)
The AFCT-701ASDZ accepts an LVTTL compatible transmit disable control signal input which shuts down the
transmitter optical output. A high signal implements this
function while a low signal allows normal transceiver operation. In the event of a fault (e.g. eye safety circuit activated), cycling this control signal resets the module as
depicted in Figure 5. An internal pull up resistor disables
the transceiver transmitter until the host pulls the input
low. TX_DISABLE can also be asserted via the two-wire
interface (address A2h, byte 110, bit 6) and monitored
(address A2h, byte 110, bit 7).
The contents of A2h, byte 110, bit 6 are logic OR’d with
hardware TX_DISABLE (contact 3) to control transmitter
operation. The normal behavior of this feature is to reset
a TX disabled transceiver to TX enabled when it is power
cycled or hot-plugged.
3
Receiver Section
Caution
The receiver section includes the Receiver Optical SubAssembly (ROSA) and the amplification/quantization circuitry. The ROSA, containing a PIN photodiode and custom transimpedance amplifier, is located at the optical
interface and mates with the LC optical connector. The
ROSA output is fed to a custom IC that provides postamplification and quantization.
The post-amp IC also includes transition detection circuitry which monitors the AC level of incoming optical
signals and provides a LVTTL/CMOS compatible status
signal to the host. A high status signal indicates loss of
modulated signal, indicating link failures such as broken
fiber or failed transmitter. Rx_LOS can also be monitored
via the two-wire serial interface (address A2h, byte 110,
bit 1).
There are no user serviceable parts nor maintenance
requirements for the AFCT-701ASDZ. All mechanical
adjustments are made at the factory prior to shipment.
Tampering with, modifying, misusing or improperly handling the AFCT-701ASDZ will void the product warranty.
It may also result in improper operation and possibly
overstress the laser source. Performance degradation or
device failure may result. Connection of the AFCT-701ASDZ to a light source not compliant with IEEE Std. 802.3ae
Clause 52 and SFF-8341 specifications, operating above
maximum operating conditions or in a manner inconsistent with it’s design and function may result in exposure
to hazardous light radiation and may constitute an act
of modifying or manufacturing a laser product. Persons
performing such an act are required by law to recertify
and re-identify the laser product under the provisions of
U.S. 21 CFR (Subchapter J) and TUV.
Functional Data I/O
Customer Manufacturing Processes
The AFCT-701ASDZ interfaces with the host circuit board
through the twenty contact SFP+ electrical connector.
See Table 2 for contact descriptions. The module edge
connector is shown in Figure 3. The host board layout for
this interface is depicted in Figure 6.
This module is pluggable and is not designed for aqueous wash, IR reflow, or wave soldering processes.
Receiver Loss of Signal (Rx_LOS)
The AFCT-701ASDZ high speed transmit and receive interfaces require SFF-8431 compliant signal lines on the
host board. To simplify board requirements, biasing resistors and AC coupling capacitors are incorporated into
the SFP+ transceiver module (per SFF-8431) and hence
are not required on the host board. The TX_DISABLE, TX_
FAULT and RX_LOS signals require LVTTL signals on the
host board (per SFF-8431) if used. If an application does
not take advantage of these functions, care must be taken to ground TX_DISABLE to enable normal operation.
Figure 2 depicts the recommended interface circuit to
link the AFCT-701ASDZ to supporting physical layer ICs.
Timing for the dedicated SFP+ control signals implemented in the transceiver are listed in Figure 5.
Application Support
An Evaluation Kit and Reference Designs are available to
assist in evaluation of the AFCT-701ASDZ. Please contact
your local Field Sales representative for availability and
ordering details.
4
Ordering Information
Please contact your local field sales engineer or one of
Avago Technologies franchised distributors for ordering
information. For technical information, please visit Avago Technologies’ WEB page at www.avagotech.com. For
information related to SFF Committee documentation
visit www.sffcommittee.org.
Regulatory Compliance
Electromagnetic Interference (EMI)
The AFCT-701ASDZ complies with all applicable laws
and regulations as detailed in Table 1. Certification level
is dependent on the overall configuration of the host
equipment. The transceiver performance is offered as a
figure of merit to assist the designer.
Equipment incorporating 10 gigabit transceivers is
typically subject to regulation by the FCC in the United
States, CENELEC EN55022 (CISPR 22) in Europe and VCCI
in Japan. The AFCT-701ASDZ enables equipment compliance to these standards detailed in Table 1. The metal
housing and shielded design of the AFCT-701ASDZ minimizes the EMI challenge facing the equipment designer.
For superior EMI performance it is recommended that
equipment designs utilize SFP+ cages per SFF 8432.
Electrostatic Discharge (ESD)
The AFCT-701ASDZ is compatible with ESD levels found
in typical manufacturing and operating environments
as described in Table 1. In the normal handling and operation of optical transceivers, ESD is of concern in two
circumstances.
The first case is during handling of the transceiver prior
to insertion into an SFP compliant cage. To protect the
device, it’s important to use normal ESD handling precautions. These include use of grounded wrist straps,
work-benches and floor wherever a transceiver is handled.
The second case to consider is static discharges to the
exterior of the host equipment chassis after installation.
If the optical interface is exposed to the exterior of host
equipment cabinet, the transceiver may be subject to
system level ESD requirements.
RF Immunity (Susceptibility)
Due to its shielded design, the EMI immunity of the AFCT-701ASDZ exceeds typical industry standards.
Eye Safety
The AFCT-701ASDZ provides Class 1 (single fault tolerant) eye safety by design and has been tested for compliance with the requirements listed in Table 1. The eye
safety circuit continuously monitors the optical output
power level and will disable the transmitter upon detecting a condition beyond the scope of Class 1 certification Such conditions can be due to inputs from the
host board (Vcc fluctuation, unbalanced code) or a fault
within the transceiver. US CDRH and EU TUV certificates
are listed in table 1.
Flammability
The AFCT-701ASDZ optical transceiver is made of metal
and high strength, heat resistant, chemical resistant and
UL 94V-0 flame retardant plastic.
5
Table 1. Regulatory Compliance
Feature
Test Method
Performance
Electrostatic Discharge (ESD)
to the Electrical Contacts
MIL-STD883C Method 3015.4
JEDEC DESD22-A11-4-B
Class 1 (> 1KV) for high speed I/O pins
Class 1 (> 2KV) for all other pins
Electrostatic Discharge (ESD)
to the Duplex LC Receptacle
IEC 61000-4-2
Typically, no damage occurs with 25 kV when
the duplex LC connector receptacle is
contacted by a Human Body Model probe.
Life Traffic ESD Immunity
IEC 61000-4-2
10 contacts of 8 kV on the electrical faceplate
with device inserted into a panel.
Life Traffic ESD Immunity
IEC 61000-4-2
Air discharge of 15 kV (min.) contact to
connector without damage.
Electromagnetic
Interference (EMI)
FCC Class B
CENELEC EN55022 Class B
(CISPR 22A)
VCCI Class 1
System margins are dependent on customer
board and chassis design.
RF Immunity
IEC 61000-4-3
Typically shows no measurable effect from a 10
V/m field swept from 80MHz to 1 GHz
Laser Eye Safety and
Equipment Type Testing
US FDA CDRH AEL Class 1
US21 CFR, Subchapter J per
Paragraphs 1002.10 and 1002.12
CDRH Accession No. 9521220-158
Pending Completion
BAUART
¨
GEPRUFT
¨
TUV
Rheinland
Product Safety
TYPE
APPROVED
(IEC) EN60825-1: 1994 + A11 + A2
(IEC) EN60825-2: 1994 + A1
(IEC) EN60950: 1992 + A1 + A2 + A3
+ A4 + A11
Component Recognition
Underwriters Laboratories and Canadian
Standards Association Joint Component
Recognition for Information Technology
Equipment including Electrical Business
Equipment
UL file E173874
RoHS Compliance
RoHS Directive 2002/95/EC and
it’s amendment directives 6/6
SGS Test Report No. LPC1/00895/08
CTS ref. CTS/08-0238/Avago
6
VccT
VeeT
10 kΩ
TX_DISABLE
TX_DISABLE
TX_FAULT
TX_FAULT
TD+
0.1 μF
100 Ω
TD–
0.1 μF
4.7 k to 10 kΩ
4.7uH
Host
Vcc
0 .1μF
DCR=0.15
22μF
LASER DRIVER
VccT
0 .1μF
0.5Ω
PROTOCOL IC
SERDES IC
VccR
4.7uH
.
0 .1μF
4.7 k to
10 kΩ
DCR=0.15
22μF
VccR
VccR
0 .1μF
.
50 Ω
0.5Ω
50 Ω
0.1 μF
RD+
100 Ω
RD–
0.1 μF
RX_LOS
LOSS OF SIGNAL
RS0
RS1
VccHost
VccHTWI
VeeR
4.7 k to 10 kΩ
MODULE DETECT
SCL
SDA
Figure 2. Typical application configuration
7
1.1 k to 8 kΩ
POST AMPLIFIER
1.1 k to 8 kΩ
MOD_ABS
SCL
SDA
Table 2. Contact Description
Contact Symbol
Function/Description
Notes
1
VeeT
Transmitter Signal Ground
Note 1
2
TX_FAULT
Transmitter Fault (LVTTL-O) – High indicates a fault condition
Note 2
3
TX_DISABLE
Transmitter Disable (LVTTL-I) – High or open disables the transmitter
Note 3
4
SDA
Two Wire Serial Interface Data Line (LVCMOS – I/O)
(same as MOD-DEF2 in INF-8074)
Note 4
5
SCL
Two Wire Serial Interface Clock Line (LVCMOS – I/O)
(same as MOD-DEF1 in INF-8074)
Note 4
6
MOD_ABS
Module Absent (Output), connected to VeeT or VeeR in the module
Note 5
7
RS0
Rate Select 0 - Not used, Presents high input impedance.
8
RX_LOS
Receiver Loss of Signal (LVTTL-O)
9
RS1
Rate Select 1 - Not used, Presents high input impedance.
10
VeeR
Receiver Signal Ground
Note 1
11
VeeR
Receiver Signal Ground
Note 1
12
RD-
Receiver Data Out Inverted (CML-O)
13
RD+
Receiver Data Out (CML-O)
14
VeeR
Receiver Signal Ground
15
VccR
Receiver Power + 3.3 V
16
VccT
Transmitter Power + 3.3 V
17
VeeT
Transmitter Signal Ground
18
TD+
Transmitter Data In (CML-I)
19
TD-
Transmitter Data In Inverted (CML-I)
20
VeeT
Transmitter Signal Ground
Notes:
1.
2.
3.
4.
5.
The module signal grounds are isolated from the module case.
This is an open collector/drain output that on the host board requires a 4.7 kΩ to 10 kΩ pullup resistor to VccHost. See Figure 2.
This input is internally biased high with a 4.7 kΩ to 10 kΩ pullup resistor to VccT.
Two-Wire Serial interface clock and data lines require an external pullup resistor dependent on the capacitance load.
This is a ground return that on the host board requires a 4.7 kΩ to 10 kΩ pullup resistor to VccHost.
10
11
BOTTOM OF
BOARD AS
VIEWED FROM
TOP THROUGH
BOARD
TOWARD
HOST
1
Figure 3. Module edge connector contacts
8
TOP VIEW
OF BOARD
20
Note 2
Note 1
Note 1
Table 3. Absolute Maximum Ratings
Stress in excess of any of the individual Absolute Maximum Ratings can cause immediate catastrophic damage to
the module even if all other parameters are within Recommended Operating Conditions. It should not be assumed
that limiting values of more than one parameter can be applied concurrently. Exposure to any of the Absolute Maximum Ratings for extended periods can adversely affect reliability.
Parameter
Symbol
Minimum
Maximum
Unit
Storage Temperature
TS
-40
100
C
Case Operating Temperature
TC
-40
100
C
Relative Humidity
RH
5
95
%
Supply Voltage
VccT, VccR
-0.3
3.8
V
Low Speed Input Voltage
-0.5
Vcc+0.5
V
Two-Wire Interface Input Voltage
-0.5
Vcc+0.5
V
High Speed Input Voltage, Single Ended
-0.3
Vcc+0.5
V
2.5
V
20
mA
1.5
dBm
High Speed Input Voltage, Differential
Low Speed Output Current
-20
Optical Receiver Input Average Power
Note;
Notes
Note 1
1. The module supply voltages, VccT and VccR must not differ by more than 0.5 V or damage to the device may occur.
Table 4. Recommended Operating Conditions
Recommended Operating Conditions specify parameters for which the electrical and optical characteristics hold
unless otherwise noted. Optical and electrical charactristics are not defined for operation outside the Recommended Operating Conditions, reliability is not implied and damage to the module may occur for such operation over an
extended period of time. The SFP+ Module Power Supply Requirements are specified in the latest revision of SFF
8431 MSA.
Parameter
Symbol
Minimum
Maximum
Unit
Notes
Case Operating Temperature
TC
0
85
°C
Note 1
Module Supply Voltage
VccT, VccR
3.135
3.465
V
10.311
10.313
GBd
66
mVp-p
Signal Rate
Power Supply Noise Tolerance
including Ripple
Tx Input Single Ended DC
Voltage Tolerance (Ref VeeT)
V
-0.3
4.0
V
Rx Output Single Ended Voltage Tolerance
V
-0.3
4.0
V
Note 2
Notes:
1. Ambient operating temperature limits are based on the Case Operating Temperature limits and are subject to the host system thermal design.
See Figure 6 for the module Tc reference point.
2. The Power Supply Filter (PSF) and resulting Power Supply Noise Tolerance (PSNT) are specified in the SFF 8431 MSA. The PSNT value applies over
the range from 10Hz to 10MHz.
9
Table 5. Low Speed Signal Electrical Characteristics
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Typical values are for Tc = 40°C. VccT and VccR = 3.3 V.
Parameter
Symbol
Module Supply Current
ICC
Minimum
Typical
Maximum
Unit
258
361
mA
850
Power Dissipation
PDISS
1250
mW
TX_FAULT, RX_LOS
IOH
- 50
+ 37.5
PA
VOL
- 0.3
0.4
V
VIH
2.0
VccT + 0.3
V
VIL
-0.3
0.8
V
TX_DISABLE
Notes
Note 1
Note 2
Note 3
Notes:
1. Supply current includes both VccT and VccR connections.
2. Measured with a 4.7 k Ω load to VccHost.
3. TX_DISABLE has an internal 4.7 kΩ to 10 kΩ pull-up to VccT
Table 6. High Speed Signal Electrical Characteristics
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Parameter
Symbol
Minimum
Tx Input Differential Voltage, |(TD +) - (TD-)|
VI
180
Tx Input AC Common Mode Voltage Tolerance
Typical
Maximum
Unit
Notes
700
mV
Note 1
15
mV(RMS)
Tx Input Differential S-parameter (100 Ω Ref.)
SDD11
-12
Note 3
dB
dB
0.01-1.0 GHz
1.0-11.1 GHz
Tx Input Reflected Differential to
Common Mode Conversion (25 Ω Ref.)
SCD11
-10
dB
0.01-11.1 GHz
Rx Output Differential Voltage, |(RD +) - (RD-)|
Vo
850
mV
Note 2
Rx Output Termination Mismatch @ 1MHz
'Zm
5
%
7.5
mV(RMS)
300
Rx Output AC Common Mode Voltage
Rx Output Output Rise and Fall Time
(20% to 80%)
tr, tf
Rx Output Total Jitter
TJ
0.70
Ulp-p
Rx Output Deterministic Jitter
DJ
0.42
Ulp-p
Rx Output Differential S-parameter
(100 Ω Ref.)
SDD22
-12
Note 4
dB
dB
0.01-1.0 GHz
1.0-11.1 GHz
Rx Output Common Mode Reflection
Coefficient (25 Ω Ref.)
SCC22
-6
-3
dB
dB
0.01-2.5 GHz
2.5-11.1 GHz
Receiver Output Eye Mask
28
Note 5
ps
See Figure 4a
Notes:
1.
2.
3.
4.
5.
10
Internally AC coupled and terminated (100 Ohm differential).
Internally AC coupled but requires an external load termination (100 Ohm differential).
Reflection Coefficient given by equation SDD11(dB)=Max(-12 + 2*SQRT(f ) -6.3+13Log10(f/5.5)), with f in GHz.
Differential Output S-parameter given by equation SDD22(dB)= Max(-12 + 2*SQRT(f ) -6.3+13Log10(f/5.5)), with f in GHz.
The RMS value is measured by calculating the standard deviation of the histogram for one UI of the common mode signal.
1.40
1.0
NORMALIZED AMPLITUDE
ABSOLUTE AMPLITUDE - mV
425
150
0
-150
0.75
0.73
0.5
0.28
0.25
0
-425
-0.40
0.35
0
0
1.0
0.65
NORMALIZED TIME (UNIT INTERVAL)
Figure 4a. Receiver Electrical Optical Eye Mask Definition
0.25 0.40 0.45 0.55 0.60 0.75
1
NORMALIZED TIME (UNIT INTERVAL)
Figure 4b. Transmitter Optical Eye Mask Definition
Table 7. Two-Wire Interface Electrical Characteristics
Parameter
Symbol
Min.
Max.
Unit
Host Vcc Range
VccHTWI
3.135
3.465
V
SCL and SDA
VOL
0.0
0.40
V
VOH
VccHTWI - 0.5
VccHTWI + 0.3
V
VIL
-0.3
VccT*0.3
V
SCL and SDA
Conditions
Rp[1] pulled to VccHTWI,
measured at host side of
connector
VIH
VccT*0.7
VccT + 0.5
V
Input Current on the
SCL and SDA Contacts
Il
-10
10
μA
Capacitance on SCL
and SDA Contacts
Ci[2]
14
pF
Total bus capacitance
for SCL and for SDA
Cb[3]
100
pF
At 400 kHz, 3.0 kΩ Rp, max
At 100 kHz, 8.0 kΩ Rp, max
290
pF
At 400 kHz, 1.1 kΩRp, max
At 100 kHz, 2.75 kΩ Rp, max
Notes:
1. Rp is the pull up resistor. Active bus termination may be used by the host in place of a pullup resistor. Pull ups can be connected to various
power supplies, however the host board design shall ensure that no module contact has voltage exceeding VccT or VccR by 0.5 V nor requires
the module to sink more than 3.0 mA current.
2. Ci is the capacitance looking into the module SCL and SDA contacts
3. Cb is the total bus capacitance on the SCL or SDA bus.
11
Table 8. Optical Specifications
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Parameter
Minimum
Typical
Maximum
Units
Notes
dBm
1
0.5
dBm
1
-30
dBm
1
dB
1
3.2
dB
1
1355
nm
Transmitter
Laser OMA output power
-5.2
Laser mean output power
-8.2
Laser off power
Extinction ratio
3.5
Transmitter and dispersion penalty (TDP)
Center Wavelength
1260
Side Mode Suppression Ratio - SMSR
30
dB
RIN12OMA
-128
dB/Hz
1
Optical Return Loss Tolerance
12
dB
1
Transmitter Output Eye Mask
1, See Figure 4b
Receiver
Stressed sensitivity (OMA)
-10.3
dBm
Receive sensitivity (OMA)
-12.6
dBm
Receive Power (Pave) Overload
0.5
Reflectance
Center Wavelength
1260
RX_LOS (OMA) De-Assert
1
dBm
1
-12
dB
1
1355
nm
1
-17
dBm
3
3
RX_LOS (OMA) Assert
-30
dBm
RX_LOS (OMA) Hysteresis
0.5
dB
Vertical eye closure penalty
2.2
dB
2
Stressed eye jitter
0.3
UI p-p
2
General Specification Considerations (Notes):
1. IEEE 802.3ae Clause 52 compliant.
2. Vertical eye closure and stressed eye jitter are test conditions for stressed sensitivity (OMA) measurements.
3. Loss of Signal (LOS) detection responds only to OMA and the indicator will respond unpredictably with the application of unmodulated optical
power.
12
Table 9. Control Functions: Low Speed Signals Timing Characteristics
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Parameter
Symbol
Maximum
Unit
Notes
TX_DISABLE Assert Time
t_off
Minimum
100
μs
Note 1 , Fig. 5
TX_DISABLE Negate Time
t_on
2
ms
Note 2 , Fig. 5
Time to initialize, including reset of TX_FAULT
t_init
300
ms
Note 3 , Fig. 5
TX_FAULT Assert Time
t_fault
1000
μs
Note 4 , Fig. 5
TX_DISABLE to Reset
t_reset
μs
Note 5 , Fig. 5
RX_LOS Assert Time
t_los_on
100
μs
Note 6 , Fig. 5
RX_LOS Deassert Time
t_los_off
100
μs
Note 7 , Fig. 5
10
Notes:
1. Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal. A 10 ms interval between assertions of TX_
DISABLE is required.
2. Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal.
3. Time from power on or falling edge of TX_DISABLE to when the modulated optical output rises above 90% of nominal and the Two-Wire
interface is available.
4. From power on or negation of TX_FAULT using TX_DISABLE.
5. Time TX_DISABLE must be held high to reset the laser fault shutdown circuitry.
6. Time from loss of optical signal to Rx_LOS Assertion.
7. Time from valid optical signal to Rx_LOS De-Assertion.
Table 10. Control Functions: Two-Wire Interface Timing Characteristics
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Parameter
Symbol
Maximum
Unit
Notes
TX_DISABLE Assert Time
t_off_twi
Minimum
100
ms
Note 1
TX_DISABLE Negate Time
t_on_twi
100
ms
Note 2
TX_FAULT Assert Time
t_fault_twi
100
ms
Note 3
Rx_LOS Assert Time
t_loss_on_twi
100
ms
Note 4
Rx_LOS Deassert Time
t_loss_off_twi
100
ms
Note 5
Analog parameter data ready
t_data
1000
ms
Note 6
Two-Wire Interface Ready
t_serial
300
ms
Note 7
Complete Single or Sequential Write up to 4 Byte
t_write
40
ms
Note 8
Complete Sequential Write of 5-8 Byte
t_write
80
ms
Note 8
400
kHz
Note 8
Ps
Note 9
Two-Wire Interface Clock Rate
f_serial_clock
Time bus free before new
transmission can start
t_BUF
20
Notes:
1. Time from two-wire interface assertion of TX_DISABLE (A2h, byte 110, bit 6) to when the optical output falls below 10% of nominal. Measured
from falling clock edge after stop bit of write transaction.
2. Time from two-wire interface de-assertion of TX_DISABLE (A2h, byte 110, bit 6) to when the modulated optical output rises above 90% of
nominal.
3. Time from fault to two-wire interface TX_FAULT (A2h, byte 110, bit 2) asserted.
4. Time for two-wire interface assertion of Rx_LOS (A2h, byte 110, bit 1) from loss of optical signal.
5. Time for two-wire interface de-assertion of Rx_LOS (A2h, byte 110, bit 1) from presence of valid optical signal.
6. From power on to data ready bit asserted (A2h, byte 110, bit 0). Data ready indicates analog monitoring circuitry is functional.
7. Time from power on until module is ready for data transmission over the two-wire interface (reads or writes over A0h and A2h).
8. Operation of the Two Wire Serial Interface at rtes beyond 100kHz requires the use of clock stretching techniques.
9. Between STOP and START. See SFF 8431 Section 4.3
13
Table 11. Transceiver Digital Diagnostic Monitor (Real Time Sense) Characteristics
The following characteristics are defined over the Recommended Operating Conditions unless otherwise noted.
Parameter
Symbol
Min.
Units
Notes
Transceiver Internal Temperature
TINT
±3.0
°C
Temperature is measured internal to the transceiver.
Valid from = -10°C to 85°C case temperature.
Transceiver Internal Supply
Voltage
VINT
±0.1
V
Supply voltage is measured internal to the transceiver
and can, with less accuracy, be correlated to
voltage at the VccT contact. Valid over 3.3 V ± 10%.
Transmitter Laser DC Bias Current
IINT
±10
%
IINT accuracy is better than ±10% of the nominal value.
Transmitted Average Optical
Output Power
PT
±3.0
dB
Average Power coupled into 9/125 μm single-mode
fiber. Valid from151 μW to 1120 μW.
Received Average Optical Input
Power
PR
±3.0
dB
Average Power coupled from 9/125 μm single-mode
fiber. Valid from 25 μW to 1120 μW.
VCCT, VCCR > 2.97 V
VCCT, VCCR > 2.97 V
TX_FAULT
TX_FAULT
TX_DISABLE
TX_DISABLE
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
t_init
t_init
t-init: TX DISABLE NEGATED
t-init: TX DISABLE ASSERTED
VCCT, VCCR > 2.97 V
TX_FAULT
TX_FAULT
TX_DISABLE
TX_DISABLE
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
INSERTION
t_off
t_init
t-init: TX DISABLE NEGATED, MODULE HOT PLUGGED
t_on
t-off & t-on: TX DISABLE ASSERTED THEN NEGATED
OCCURANCE OF FAULT
OCCURANCE OF FAULT
TX_FAULT
TX_FAULT
TX_DISABLE
TX_DISABLE
TRANSMITTED SIGNAL
TRANSMITTED SIGNAL
t_fault
* SFP SHALL CLEAR TX_FAULT IN
< t_init IF THE FAILURE IS TRANSIENT
t-fault: TX FAULT OCCURED
t_reset
t_init*
t-reset: TX DISABLE ASSERTED THEN NEGATED, TX SIGNAL RECOVERED
OCCURANCE OF FAULT
TX_FAULT
LOS
TRANSMITTED SIGNAL
* SFP SHALL CLEAR TX_FAULT IN
< t_init IF THE FAILURE IS TRANSIENT
t_reset
t_fault
t_loss_on
t_init*
t-fault: TX DISABLE ASSERTED THEN NEGATED, TX SIGNAL NOT RECOVERED
t-los-on & t-los-off
Figure 5. Transceiver timing diagrams (module installed and power applied except where noted)
14
OCCURANCE
OF LOSS
OPTICAL SIGNAL
TX_DISABLE
t_loss_off
Table 12. EEPROM Serial ID Memory Contents – Conventional SFP Memory (Address A0h)
Byte #
Decimal
Data
Hex
Notes
Byte #
Decimal
Data
Hex
Notes
0
03
SFP physical device
37
00
Hex Byte of Vendor OUI[1]
1
04
SFP function defined by serial ID only
38
17
Hex Byte of Vendor OUI[1]
2
07
LC optical connector
39
6A
Hex Byte of Vendor OUI[1]
3
20
10G Base-LR
40
41
“A” - Vendor Part Number ASCII character
4
00
41
46
“F” - Vendor Part Number ASCII character
5
00
42
43
“C” - Vendor Part Number ASCII character
6
00
43
54
“T” - Vendor Part Number ASCII character
7
00
44
2D
“-” - Vendor Part Number ASCII character
8
00
45
37
“7” - Vendor Part Number ASCII character
9
00
46
30
“0” - Vendor Part Number ASCII character
10
00
47
31
“1” - Vendor Part Number ASCII character
11
06
64B/66B
48
41
“A” - Vendor Part Number ASCII character
12
67
10312.5 Mbit/sec nominal bit rate (10.3125
Gbit/s)
49
53
“S” - Vendor Part Number ASCII character
13
00
Unspecified
50
44
“D” - Vendor Part Number ASCII character
14
0A
10GBASE-LR 10km
51
5A
“Z” - Vendor Part Number ASCII character
15
64
10GBASE-LR 10km
52
20
“ ” - Vendor Part Number ASCII character
16
00
53
20
“ ” - Vendor Part Number ASCII character
17
00
54
20
“ ” - Vendor Part Number ASCII character
18
00
55
20
“ ” - Vendor Part Number ASCII character
19
00
56
20
“ ” - Vendor Part Number ASCII character
20
41
“A” - Vendor Name ASCII character
57
20
“ ” - Vendor Part Number ASCII character
21
56
“V” - Vendor Name ASCII character
58
20
“ ” - Vendor Part Number ASCII character
22
41
“A” - Vendor Name ASCII character
59
20
“ ” - Vendor Part Number ASCII character
23
47
“G” - Vendor Name ASCII character
60
05
Hex Byte of Laser Wavelength[2]
24
4F
“0” - Vendor Name ASCII character
61
1E
Hex Byte of Laser Wavelength[2]
25
20
“ ” - Vendor Name ASCII character
62
00
26
20
“ ” - Vendor Name ASCII character
63
27
20
“ ” - Vendor Name ASCII character
64
00
Receiver limiting output. 1 Watt power
class.
28
20
“ ” - Vendor Name ASCII character
65
1A
Hardware SFP TX_DISABLE, TX_FAULT,
& RX_LOS
29
20
“ ” - Vendor Name ASCII character
66
00
30
20
“ ” - Vendor Name ASCII character
67
00
31
20
“ ” - Vendor Name ASCII character
68-83
Vendor Serial Number ASCII characters[4]
32
20
“ ” - Vendor Name ASCII character
84-91
Vendor Date Code ASCII characters[5]
33
20
“ ” - Vendor Name ASCII character
92
68
Digital Diagnostics, Internal Cal, Rx Pwr Avg
34
20
“ ” - Vendor Name ASCII character
93
F0
A/W, Soft SFP TX_DISABLE, TX_FAULT,
& RX_LOS
35
20
“ ” - Vendor Name ASCII character
94
03
36
00
Checksum for Bytes 0-62[3]
96 - 255
SFF-8472 Compliance to revision 10.2
Checksum for Bytes 64-94[3]
95
00
Notes:
1. The IEEE Organizationally Unique Identifier (OUI) assigned to Avago Technologies is 00-17-6A (3 bytes of hex).
2. Laser wavelength is represented in 16 unsigned bits.
3. Addresses 63 and 95 are checksums calculated (per SFF-8472) and stored prior to product shipment.
4. Addresses 68-83 specify the AFCT-701ASDZ ASCII serial number and will vary on a per unit basis.
5. Addresses 84-91 specify the AFCT-701ASDZ ASCII date code and will vary on a per date code basis.
15
Table 13. EEPROM Serial ID Memory Contents – Enhanced Feature Set Memory (Address A2h)
Byte #
Decimal
Notes
Byte #
Decimal
Notes
Byte #
Decimal
Notes
0
Temp H Alarm MSB[1]
26
Tx Pwr L Alarm MSB[4]
104
Real Time Rx Pwr MSB[5]
1
Temp H Alarm LSB[1]
27
Tx Pwr L Alarm LSB[4]
105
Real Time Rx Pwr LSB[5]
2
Temp L Alarm MSB[1]
28
Tx Pwr H Warning MSB[4]
106
Reserved
3
Temp L Alarm LSB[1]
29
Tx Pwr H Warning LSB[4]
107
Reserved
4
Temp H Warning MSB[1]
30
Tx Pwr L Warning MSB[4]
108
Reserved
5
Temp H Warning LSB[1]
31
Tx Pwr L Warning LSB[4]
109
Reserved
6
Temp L Warning MSB[1]
32
Rx Pwr H Alarm MSB[5]
110
Status/Control
- See Table 15
7
Temp L Warning LSB[1]
33
Rx Pwr H Alarm LSB[5]
111
Reserved
8
Vcc H Alarm MSB[2]
34
Rx Pwr L Alarm MSB[5]
112
Flag Bits - See Table 16
9
Vcc H Alarm LSB[2]
35
Rx Pwr L Alarm LSB[5]
113
Flag Bits - See Table 16
10
Vcc L Alarm MSB[2]
36
Rx Pwr H Warning MSB[5]
114
Reserved
11
Vcc L Alarm LSB[2]
37
Rx Pwr H Warning LSB[5]
115
Reserved
12
Vcc H Warning MSB[2]
38
Rx Pwr L Warning MSB[5]
116
Flag Bits - See Table 16
13
Vcc H Warning LSB[2]
39
Rx Pwr L Warning LSB[5]
117
Flag Bits - See Table 16
14
Vcc L Warning MSB[2]
40-55
Reserved
118-127
Reserved
15
Vcc L Warning LSB[2]
56-94
External Calibration Constants[6]
128-247
Customer Writeable
16
Tx Bias H Alarm MSB[3]
95
Checksum for Bytes 0-94[7]
248-255
Vendor Specific
17
Tx Bias H Alarm LSB[3]
96
Real Time Temperature MSB[1]
18
Tx Bias L Alarm MSB[3]
97
Real Time Temperature LSB[1]
19
Tx Bias L Alarm LSB[3]
98
Real Time Vcc MSB[2]
20
Tx Bias H Warning MSB[3]
99
Real Time Vcc LS[2]
21
Tx Bias H Warning LSB[3]
100
Real Time Tx Bias MSB[3]
22
Tx Bias L Warning MSB[3]
101
Real Time Tx Bias LSB[3]
23
Tx Bias L Warning LSB[3]
102
Real Time Tx Power MSB[4]
24
Tx Pwr H Alarm MSB[4]
103
Real Time Tx Power LSB[4]
25
Tx Pwr H Alarm LSB[4]
Notes:
1. Temperature (Temp) is decoded as a 16 bit signed twos compliment integer in increments of 1/256°C.
2. Supply Voltage (Vcc) is decoded as a 16 bit unsigned integer in increments of 100 μV.
3. Laser bias current (Tx Bias) is decoded as a 16 bit unsigned integer in increments of 2 μA.
4. Transmitted average optical power (Tx Pwr) is decoded as a 16 bit unsigned integer in increments of 0.1 μW.
5. Received average optical power (Rx Pwr) is decoded as a 16 bit unsigned integer in increments of 0.1 μW.
6. Bytes 56-94 are not intended for use with AFCT-701ASDZ, but have been set to default values per SFF-8472.
7. Byte 95 is a checksum calculated (per SFF-8472) and stored prior to product shipment.
16
Table 14. EEPROM Serial ID Memory Contents – Soft Commands (Address A2h, Byte 110)
Bit #
Status/
Control Name
Description
Notes
7
TX_ DISABLE State
Digital state of SFP TX_ DISABLE Input (1 = TX_DISABLE asserted)
Note 1
6
Soft TX_ DISABLE
Read/write bit for changing digital state of TX_DISABLE function
Note 1, 2
5
Reserved
4
Reserved
3
Reserved
2
TX_FAULT State
Digital state of the SFP TX_FAULT Output (1 = TX_FAULT asserted)
Note 1
1
RX_LOS State
Digital state of the SFP RX_LOS Output (1 = RX_LOS asserted)
Note 1
0
Data Ready (Bar)
Indicates transceiver is powered and real time sense data is ready. (0 = Ready)
Notes:
1. The response time for soft commands of the AFCT-701ASDZ is 100 msec as specified by SFF-8472.
2. Bit 6 is logic OR’d with the SFP TX_DISABLE input on contact 3; either asserted will disable the SFP+ transmitter.
Table 15. EEPROM Serial ID Memory Contents – Alarms and Warnings (Address A2h, Bytes 112, 113, 116, 117)
Byte
Bit
Flag Bit Name Description
112
7
Temp High Alarm
Set when transceiver internal temperature exceeds high alarm threshold
6
Temp Low Alarm
Set when transceiver internal temperature exceeds low alarm threshold
5
Vcc High Alarm
Set when transceiver internal supply voltage exceeds high alarm threshold
4
Vcc Low Alarm
Set when transceiver internal supply voltage exceeds low alarm threshold
3
Tx Bias High Alarm
Set when transceiver laser bias current exceeds high alarm threshold
2
Tx Bias Low Alarm
Set when transceiver laser bias current exceeds low alarm threshold
1
Tx Power High Alarm
Set when transmitted average optical power exceeds high alarm threshold
0
Tx Power Low Alarm
Set when transmitted average optical power exceeds low alarm threshold
7
Rx Power High Alarm
Set when received average optical power exceeds high alarm threshold
6
Rx Power Low Alarm
Set when received average optical power exceeds low alarm threshold
0-5
Reserved
7
Temp High Warning
Set when transceiver internal temperature exceeds high warning threshold
6
Temp Low Warning
Set when transceiver internal temperature exceeds low warning threshold
5
Vcc High Warning
Set when transceiver internal supply voltage exceeds high warning threshold
4
Vcc Low Warning
Set when transceiver internal supply voltage exceeds low warning threshold
3
Tx Bias High Warning
Set when transceiver laser bias current exceeds high warning threshold
2
Tx Bias Low Warning
Set when transceiver laser bias current exceeds low warning threshold
1
Tx Power High Warning
Set when transmitted average optical power exceeds high warning threshold
0
Tx Power Low Warning
Set when transmitted average optical power exceeds low warning threshold
7
Rx Power High Warning
Set when received average optical power exceeds high warning threshold
6
Rx Power Low Warning
Set when received average optical power exceeds low warning threshold
0-5
Reserved
113
116
117
17
7&$6(5()(5(1&(32,17
“
81&2035(66('
“
/$7&+&2/25
%/8(*%$6(/5
81&2035(66('
81&2035(66('
7;
5;
Figure 6. Module drawing
Label format
Figure 7. Module label
For product information and a complete list of distributors, please go to our website:
www.avagotech.com
Avago, Avago Technologies, and the A logo are trademarks of Avago Technologies in the United States and other countries.
Data subject to change. Copyright © 2005-2011 Avago Technologies. All rights reserved.
AV02-1534EN - January 18, 2011