ESTEK ET-79LXXND

ET-79Lxxnd
Negative-Voltage Regulators
Series 79LХХnd
· 3-Terminal Regulators
· Output Current Up to 100mA
· No External Components
· Internal Thermal Overload Protection
· Internal Short-Circuit Limiting
· Direct Replacement for Мotorola MC79L00
Series
Nominal
output
voltage
-5V
-6V
-8V
-9V
-12V
-15V
-18V
-24V
DESCRIPTION
This series of fixed-voltage monolithic integrated circuit
voltage regulators is designed for a wide range of
applications. These applications include on-card
regulation for elimination of noise and distribution
problems associated with single-point regulation. In
addition, they can be used with power-pass elements to
make high-current voltage regulators. Each of these
regulators can deliver up to 100mA of output current. The
internal limiting and termal shutdown features of these
regulators make them essentially immune to overload.
When used as a replacement for a Zener diode-resistor
combination , an effective improvement in output
impedance can be obtained together with lower-bias
current.
Regulator
79L05nd
79L06nd
79L08nd
79L09nd
79L12nd
79L15nd
79L18nd
79L24nd
КБ5009ЕН5-4/МВ
КБ5009ЕН6-4/МВ
КБ5009ЕН8-4/МВ
КБ5009ЕН9-4/МВ
КБ5009ЕН12-4/МВ
КБ5009ЕН15-4/МВ
КБ5009ЕН18-4/МВ
КБ5009ЕН24-4/МВ
Absolute maximum ratings over operating temperature range (unless otherwise noted)
79L05nd
thru
79L09nd
-30
0 to 150
-65 to 150
260
Input voltage
Operating free-air, case, or virtual junction temperature range
Storage temperature range
Lead temperature 1.6 mm (1/16 inch) from case for 10 seconds
79L12nd
thru
79L18nd
-35
0 to 150
-65 to 150
260
79L24nd
UNIT
-40
0 to 150
-65 to 150
260
V
0
C
Recommended operating conditions
Parameter
Input voltage, VI
MIN
-7
-8
-10.5
-12
-14.5
-17.5
-20.5
-27
79L05 nd
79L06 nd
79L08 nd
79L09 nd
79L12 nd
79L15 nd
79L18 nd
79L24 nd
Output current, Io
Operating virtual junction temperature, TJ
0
1
MAX
-20
-20
-23
-24
-27
-30
-33
-38
100
125
UNIT
V
mA
0
C
BEIJING ESTEK ELECTRONICS CO.,LTD
ET-79Lxxnd
Negative-Voltage Regulators
Series 79LХХnd
79L05nd electrical characteristics at specified virtual junction temperature, VI=-10V, IO=40mA
(unless otherwise noted)
PARAMETER
TEST CONDITIONS*
UNIT
79L05nd
Output voltage**
Input regulation
Ripple rejection
Output regulation
Output noise voltage
Dropout voltage
Bias current
Bias current change
IO=1mA to 40mA
VI=-7V to -20V
IO=1mA to 70mA
VI=-7V to -20V
VI=-8V to -20V
VI=-8V to -18V,
f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
f=10Hz-100Hz
VI=-8V to -20V
IO=1mA to 40mA
25oC
0 to 125 oC
25oC
25oC
MIN
-4.8
-4.75
-4.75
41
25oC
25oC
25oC
25oC
125oC
0 to 125 oC
TYP
MAX
-5.2
-5.25
V
-5
15
12
49
-5.25
150
100
mV
20
10
40
1.7
3.8
60
30
-5
-5
dB
6
5.5
1.5
0.1
mV
µV
V
mA
79L06nd electrical characteristics at specified virtual junction temperature, VI=-11V, IO=40mA
(unless otherwise noted)
PARAMETER
TEST CONDITIONS*
UNIT
79L06nd
o
Output voltage**
Input regulation
Ripple rejection
Output regulation
Output noise voltage
Dropout voltage
Bias current
Bias current change
IO=1mA to 40mA
VI=-8V to -20V
IO=1mA to 70mA
VI=-8V to -20V
VI=-9V to -20V
VI=-9V to -19V,
f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
f=10Hz-100Hz
VI=-9V to -20V
IO=1mA to 40mA
25 C
0 to 125 oC
25oC
25oC
25oC
25oC
25oC
25oC
125oC
0 to 125 oC
MIN
-5.75
-5.7
-5.7
40
TYP
MAX
-6.25
-6.3
V
-6
20
15
48
-6.3
175
125
mV
21
11
44
1.7
80
40
-6
-6
dB
6
5.5
1.5
0.1
mV
µV
V
mA
*Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible.
Thermal effects must be taken into account separately. All characteristics are measured with a 0.33µF capacitor across the
input and a 0.1µF capacitor across the output.
**This specification applies only for dc power dissipation permitted by absolute maximum ratings.
2
BEIJING ESTEK ELECTRONICS CO.,LTD
ET-79Lxxnd
Negative-Voltage Regulators
Series 79LХХnd
79L08nd electrical characteristics at specified virtual junction temperature, VI=-14V, IO=40mA
(unless otherwise noted)
PARAMETER
TEST CONDITIONS*
UNIT
79L08nd
o
Output voltage**
Input regulation
Ripple rejection
Output regulation
Output noise voltage
Dropout voltage
Bias current
Bias current change
IO=1mA to 40mA
VI=-10.5V to -23V
IO=1mA to 70mA
VI=-10.5V to -23V
VI=-11V to -23V
VI=-13V to -23V,
f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
f=10Hz-100Hz
VI=-11V to -23V
IO=1mA to 40mA
25 C
0 to 125 oC
25oC
25oC
MIN
-7.7
-7.6
-7.6
37
25oC
25oC
25oC
25oC
125oC
0 to 125 oC
TYP
MAX
-8.3
-8.4
V
-8
42
36
46
-8.4
200
150
mV
30
15
54
1.7
100
50
-8
-8
dB
6
5.5
1.5
0.1
mV
µV
V
mA
79L09nd electrical characteristics at specified virtual junction temperature, VI=-16V, IO=40mA
(unless otherwise noted)
PARAMETER
TEST CONDITIONS*
UNIT
79L09nd
Output voltage**
Input regulation
Ripple rejection
Output regulation
Output noise voltage
Dropout voltage
Bias current
Bias current change
IO=1mA to 40mA
VI=-12V to -24V
IO=1mA to 70mA
VI=-12V to -24V
VI=-13V to -24V
VI=-15V to -24V,
f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
f=10Hz-100Hz
VI=-13V to -24V
IO=1mA to 40mA
25oC
0 to 125 oC
25oC
25oC
25oC
25oC
25oC
25oC
125oC
0 to 125 oC
MIN
-8.6
-8.55
-8.55
40
TYP
MAX
-9.4
-9.45
V
-9
45
40
45
-9.45
175
125
mV
30
15
62
1.7
100
50
-9
-9
dB
6.2
5.7
1.5
0.1
mV
µV
V
mA
*Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible.
Thermal effects must be taken into account separately. All characteristics are measured with a 0.33µF capacitor across the
input and a 0.1µF capacitor across the output.
**This specification applies only for dc power dissipation permitted by absolute maximum ratings.
3
BEIJING ESTEK ELECTRONICS CO.,LTD
ET-79Lxxnd
Negative-Voltage Regulators
Series 79LХХnd
79L12 electrical characterist ics at specified virtual junction temperature, VI=-19V, IO=40mA
(unless otherw ise noted)
PARAMETER
TEST CONDITIONS*
UNIT
79L12
Output voltage**
Input regulation
Ripple rejection
Output regulation
Output noise voltage
Dropout voltage
Bias current
Bias current change
IO=1mA to 40mA
VI=-14V to -27V
IO=1mA to 70mA
VI=-14V to -27V
VI=-16V to -27V
VI=-15V to -25V,
f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
f=10Hz-100Hz
VI=-16V to -27V
IO=1mA to 40mA
25oC
0 to 125 oC
25oC
25oC
MIN
-11.5
-11.4
TYP
-12
-12
MAX
-12.5
-12.6
V
-11.4
-12
50
40
42
-12.6
250
200
mV
24
15
80
1.7
100
50
37
25oC
25oC
25oC
25oC
125oC
0 to 125 oC
dB
6.5
6
1.5
0.1
mV
µV
V
mA
79L15 electrical characteristic s at specified virtual junction temperature, VI=-23V, IO=40mA
(unless otherw ise noted)
PARAMETER
TEST CONDITIONS*
UNIT
79L15
o
Output voltage**
Input regulation
Ripple rejection
Output regulation
Output noise voltage
Dropout voltage
Bias current
Bias current change
IO=1mA to 40mA
VI=-17.5V to -30V
IO=1mA to 70mA
VI=-17.5V to -30V
VI=-19V to -30V
VI=-18.5V to -28.5V,
f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
f=10Hz-100Hz
VI=-19V to -30V
IO=1mA to 40mA
25 C
0 to 125 oC
25oC
25oC
25oC
25oC
25oC
25oC
125oC
0 to 125 oC
MIN
-14.4
-14.25
TYP
-15
-15
MAX
-15.6
-15.75
V
-14.25
-15
65
50
39
-15.75
300
250
mV
25
15
90
1.7
150
75
34
dB
6.5
6
1.5
0.1
mV
µV
V
mA
*Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible.
Thermal effects must be taken into account separately. All characteristics are measured with a 0.33µF capacitor across the
input and a 0.1µF capacitor across the output.
**This specification applies only for dc power dissipation permitted by absolute maximum ratings.
4
BEIJING ESTEK ELECTRONICS CO.,LTD
ET-79Lxxnd
Negative-Voltage Regulators
Series 79LХХnd
79L18 electrical characterist ics at specified virtual junction temperature, VI=-26V, IO=40mA
(unless otherw ise noted)
UNIT
PARAMETER
TEST CONDITIONS*
79L18
o
Output voltage**
Input regulation
Ripple rejection
Output regulation
Output noise voltage
Dropout voltage
Bias current
Bias current change
25 C
0 to 125 oC
IO=1mA to 40mA
VI=-20.5V to -33V
IO=1mA to 70mA
VI=-20.5V to -33V
VI=-22V to -33V
VI=-21.5V to -31.5V,
f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
f=10Hz-100Hz
25oC
25oC
MIN
-17.3
-17.1
TYP
-18
-18
MAX
-18.7
-18.9
V
-17.1
-18
70
60
48
-18.9
325
275
mV
27
19
150
1.7
170
85
33
25oC
25oC
25oC
25oC
125oC
0 to 125 oC
VI=-22V to -33V
IO=1mA to 40mA
dB
6.5
6
1.5
0.1
mV
µV
V
mA
*Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible.
Thermal effects must be taken into account separately. All characteristics are measured with a 0.33µF capacitor across the
input and a 0.1µF capacitor across the output.
**This specification applies only for dc power dissipation permitted by absolute maximum ratings.
79L24 electrical characteristic s at specified virtual junction temperature, VI=-33V, IO=40mA
(unless otherw ise noted)
UNIT
PARAMETER
TEST CONDITIONS*
79L24
o
Output voltage**
Input regulation
Ripple rejection
Output regulation
Output noise voltage
Dropout voltage
Bias current
Bias current change
25 C
0 to 125 oC
IO=1mA to 40mA
VI=-27V to -38V
IO=1mA to 70mA
VI=-27 V to -38V
VI=-28V to -38V
VI=-29V to -35V,
f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
f=10Hz-100Hz
25oC
25oC
25oC
25oC
25oC
25oC
125oC
0 to 125 oC
VI=-28V to -38V
IO=1mA to 40mA
MIN
-23
-22.8
TYP
-24
-24
MAX
-25
-25.2
V
-22.8
-24
90
75
47
-25.2
350
300
mV
40
25
200
1.7
200
100
31
dB
6.5
6
1.5
0.1
mV
µV
V
mA
*Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as possible.
Thermal effects must be taken into account separately. All characteristics are measured with a 0.33µF capacitor across the
input and a 0.1µF capacitor across the output.
**This specification applies only for dc power dissipation permitted by absolute maximum ratings.
5
BEIJING ESTEK ELECTRONICS CO.,LTD