cPCIS-6400U Series 4U 5-slot CompactPCI® Chassis with Redundant Power Supplies Features 6U cPCI Platforms Standard 6U CompactPCI® and PICMG® 2.5 H.110 CT Bus PICMG® 2.1 Hot Swap compliant 32-bit or 64-bit 5-slot CompactPCI® backplane with P3 & P5 rear I/O PICMG® 2.11 Standard CompactPCI® 47-Pin Power Interface 2 + 1 hot swappable 500 W + 250 W redundant power supplies with universal AC input Built-in slim type optical drive Dual removable SATA HDD racks Guarded power switch and reset button Redundant cooling architecture Specifications Enclosure CompactPCI® Standards Form Factor Backplane Power Supply Basic Alarm Module Cooling System 3-9 EIA RS-310C 19” 4U high rackmount enclosure Coated metal plate outer covering 2.0 R3.0, 2.1 R2.0, 2.5 R1.0 6U CompactPCI® cBP-6415U: 5-slot 64-bit/66 MHz 6U CT Bus Backplane cBP-6105R: 5-slot 32-bit/33 MHz CT Bus Backplane Supports up to 3 in-rack 3U cPCI 8HP power modules Supports current sharing on 5 V, 3.3 V, and 12 V PICMG® 2.11 47-pin power interface Power module: cPS-H325/AC (250W each x3 redundant) Monitors inner chassis temperature and fan status Abnormal status will generate alarm and LED warning Alarm reset LED indicates status of 5 V, 3.3 V, 12 V, and -12 V Front-access hot-swappable fan tray for intake: • 12 V DC brush-less, precise dual-ball bearing • One 150 CFM fan for in-take • Rated speed for each fan: 4000 ±250 RPM • Rated power for each fan: 17.4 W Removable fan module for ventilation: • 12 V DC brush-less, VAPO bearing • Four 9.46 CFM fans for ventilation • Rated speed for each fan: 8000 ±1000 RPM • Rated power for each fan: 1.8 W http://www.adlinktech.com/cPCI/ Cooling System (cont’d) Drive Bay Dimensions Weight Operating Temp. Storage Temp. Humidity Shock Vibration NEBS Rear-access hot-swappable fan modules for drive bays: • 12 V DC brush-less, VAPO bearing • Two 10.8 CFM fan modules for ventilation • Rated speed for each fan: 8200 ±1000 RPM • Rated power for each fan: 1.6 W Rear-access hot-swappable fan modules for ventilation: • 12 V DC brush-less, VAPO bearing • One 110 CFM fan for ventilation • Rated speed for each fan: 4800 ±250 RPM • Rated power for each fan: 12 W Built-in one slim type optical drive Dual removable 3.5” SATA HDD racks 482.6 x 177.0 x 350.6 (mm, W x H x D, w/ handle) 14.5 kg/32 lbs (including 280 W ATX power supply and backplane) 0˚C to 55˚C (dependent on system configuration) -20˚C to 80˚C 5% to 95%, non-condensing 15 G peak-to-peak, 11 ms duration, non-operation Non-operation: 1.88 Grms, 5-500 Hz, each axis Operation: 0.5 Grms, 5-500 Hz, each axis, tested with 2.5” HDD Designed for NEBS Level 3 Recommended Configurations CPU Board (System slot) Rear I/O Board cPCIS-6400UA cPCI-6510, cPCI-6510V cPCI-R6002D*, cPCI-R6110*, cPCI-R6200*, cPCI-R6700(D) cPCI-6880, cPCI-6880P cPCI-R6002D*, cPCI-R6110*, cPCI-R6200*, cPCI-R6700(D) cPCI-6210, cPCI-6210D cPCI-R6002D*, cPCI-R6110*, cPCI-R6200*, cPCI-R6700(D) cPCIS-6400USS cPCI-6510, cPCI-6510V cPCI-R6200 cPCI-6880, cPCI-6880P cPCI-R6200 cPCI-6210, cPCI-6210D cPCI-R6200 *A 22-pin to 7-pin SATA cable is required for connecting the 3rd SATA interface Ordering Information Model Number cPCI Bus PSU Type CMM PSU MAX AC-INPUT H.110 CD/DVD ROM 2.5 HDD Rack 3.5 HDD Rack 5.25 HDD Rack Alarm Board cPCIS-6400UA/ AC/SDVD 64-bit/66MHz AT -- 3x 250W 1 Y 1x SATA DVD -- 2x SATA -- Basic Alarm Module cPCIS-6400UA/ AC/SDVD/WM 64-bit/66MHz AT -- 3x 250W 1 Y 1x SATA DVD -- 2x SATA -- Buzzer, Web UI, SNMPV2 cPCIS-6400USS/ SDVD 64-bit/66MHz AT -- 3x 250W 1 Y 1x SATA DVD -- 2x SAS -- Basic Alarm Module Mechanical Layout Rear View Slim Type Optical Drive Two HDD racks Replaceable Fan Tray for exhaust AC-Inlet Replaceable Fan Tray for exhaust 500 W + 250 W Hot-swappable Power Supply Hot-swappable Fan Tray for intake with filter 3-10