ETC CPCIS

cPCIS-6418U Series
4U 8-slot CompactPCI® System with
Redundant Power Supplies
Features
6U cPCI Platforms
Standard 6U CompactPCI® and PICMG® 2.5
H.110 CT Bus
PICMG® 2.1 Hot Swap compliant 64-bit 8-slot
CompactPCI® backplane with P3 & P5 rear I/O
Guarded power switch and reset button
Dual AC power inlets (optional DC-in)
LED indication for power status, fan status,
temperature alarm
Embedded chassis management tool to monitor
fan, temperature & voltage via RS-232 port
Specifications
Enclosure CompactPCI® Standards
Form Factor
Backplane
Power Supply Basic Alarm Module
Cooling System
3-13
EIA RS-310C 19” 4U high rackmount enclosure
Coated metal plate outer covering
2.0 R3.0, 2.1 R2.0, 2.5 R1.0
6U CompactPCI®
cBP-6418U: 8-slot 64-bit 6U cPCI CT bus backplane
Supports up to three in-rack 3U cPCI 8HP power modules
Supports current sharing on 5 V, 3.3 V, and 12 V
PICMG® 2.11 47-pin power interface
Power module: cPS-H325/AC (250 W each x3 redundant)
cPS-H325/48 (DC48V 250 W redundant each)
Monitoring inner chassis temperature, fan status
Abnormal status will generate alarm and LED warning
Alarm reset
LEDs indicate status of 5 V, 3.3 V, 12 V and 12 V
Removable left exhaust fan
• Tontal fans: One
• Fan type: DC brushless motor
• Rated voltage: 12 V
• Dimensions: 120 x 120 x 25 (mm, W x H x D)
• Maximum Air flow: 150 CFM
• Rated speed for each fan: 4000 ±250 RPM
• Rated power for each fan: 17.4 W
Exhaust fan on rear panel:
• Total fans: One
• Fan type: DC brushless motor
• Rated voltage: 12 V
• Dimensions: 92 x 92 x 38 (mm,W x H x D)
• Maximum Air flow: 110.18 CFM
• Rated speed for each fan: 4800 ±250 RPM
• Rated power for each fan: 12 W
http://www.adlinktech.com/cPCI/
Cooling System
(cont’d)
Drive Bay Dimensions
Weight
Operating Temp.
Storage Temp.
Humidity Shock
Vibration
NEBS
Hot-swappable right side intake fans: (2+2 fans)
• Total fans: Four
• Fan type: DC brushless motor
• Rated voltage: 12 V
• Dimensions: 80 x 80 x 15 (mm,W x H x D)
• Maximum Air flow: 42.73 CFM
• Rated speed for each fan: 4000 ±100 RPM
• Rated power for each fan: 3.24 W One slim type optical drive
482.6 x 177 x 346.35 (mm, W x H x D, w/ handle)
14.5 kg/31.9 lbs (including 250 W redundant power supply
and backplane)
0˚C to 50˚C
-20˚C to 80˚C
5% to 95%, non-condensing
15 G peak-to-peak, 11 ms duration, non-operation
Non-operation: 1.88 Grms, 5-500 Hz, each axis
Operation: 0.5 Grms, 5-500 Hz, each axis, tested with
2.5” HDD
Designed for NEBS Level 3
Recommended Configurations
CPU Board
(System slot)
Rear I/O Board
cPCI-6615, cPCI-6615D
cPCI-R6002
cPCI-6510, cPCI-6510V
cPCI-R6002, cPCI-R6100, cPCI-R6110, cPCI-R6210,
cPCI-R6700
cPCI-6880, cPCI-6880P
cPCI-R6002, cPCI-R6000P, cPCI-R6100, cPCI-R6110,
cPCI-R6700
cPCI-6210, cPCI-6210D
cPCI-R6002, cPCI-R6100, cPCI-R6110, cPCI-R6700
Ordering Information
Model Number
cPCI Bus
PSU Type
CMM
PSU MAX
AC/DC
H.110
CD/DVD
ROM
2.5 HDD
Rack
3.5 HDD
Rack
5.25 HDD
Rack
Alarm Board
cPCIS-6418U/AC/
SDVD
64-bit/66MHz
AT
--
3x 250W
2x AC
Y
1x SATA
DVD
--
--
--
Basic Alarm
Module
cPCIS-6418U/
2AC/SDVD
64-bit/66MHz
AT
--
2x 250W
2x AC
Y
1x SATA
DVD
--
--
--
Basic Alarm
Module
cPCIS-6418U/
AC3/VA(EA)
64-bit/66MHz
AT
--
3x 250W
1x AC
Y
1x SATA
DVD
--
--
--
Buzzer, RS-232
cPCIS-6418U/DC/
SDVD
64-bit/66MHz
AT
--
3x 250W
(DC 48V)
2x DC
Y
1x SATA
DVD
--
--
--
Buzzer, RS-232
Mechanical Layout
Rear View
Replaceable Fan Tray for
exhaust
Slim Type optical drive
500 W + 250 W Hot-swappable
Power Supply
Hot-swappable Fan Tray for
intake with filter
Dual AC Power Inlets
3-14