cPCIS-6418U Series 4U 8-slot CompactPCI® System with Redundant Power Supplies Features 6U cPCI Platforms Standard 6U CompactPCI® and PICMG® 2.5 H.110 CT Bus PICMG® 2.1 Hot Swap compliant 64-bit 8-slot CompactPCI® backplane with P3 & P5 rear I/O Guarded power switch and reset button Dual AC power inlets (optional DC-in) LED indication for power status, fan status, temperature alarm Embedded chassis management tool to monitor fan, temperature & voltage via RS-232 port Specifications Enclosure CompactPCI® Standards Form Factor Backplane Power Supply Basic Alarm Module Cooling System 3-13 EIA RS-310C 19” 4U high rackmount enclosure Coated metal plate outer covering 2.0 R3.0, 2.1 R2.0, 2.5 R1.0 6U CompactPCI® cBP-6418U: 8-slot 64-bit 6U cPCI CT bus backplane Supports up to three in-rack 3U cPCI 8HP power modules Supports current sharing on 5 V, 3.3 V, and 12 V PICMG® 2.11 47-pin power interface Power module: cPS-H325/AC (250 W each x3 redundant) cPS-H325/48 (DC48V 250 W redundant each) Monitoring inner chassis temperature, fan status Abnormal status will generate alarm and LED warning Alarm reset LEDs indicate status of 5 V, 3.3 V, 12 V and 12 V Removable left exhaust fan • Tontal fans: One • Fan type: DC brushless motor • Rated voltage: 12 V • Dimensions: 120 x 120 x 25 (mm, W x H x D) • Maximum Air flow: 150 CFM • Rated speed for each fan: 4000 ±250 RPM • Rated power for each fan: 17.4 W Exhaust fan on rear panel: • Total fans: One • Fan type: DC brushless motor • Rated voltage: 12 V • Dimensions: 92 x 92 x 38 (mm,W x H x D) • Maximum Air flow: 110.18 CFM • Rated speed for each fan: 4800 ±250 RPM • Rated power for each fan: 12 W http://www.adlinktech.com/cPCI/ Cooling System (cont’d) Drive Bay Dimensions Weight Operating Temp. Storage Temp. Humidity Shock Vibration NEBS Hot-swappable right side intake fans: (2+2 fans) • Total fans: Four • Fan type: DC brushless motor • Rated voltage: 12 V • Dimensions: 80 x 80 x 15 (mm,W x H x D) • Maximum Air flow: 42.73 CFM • Rated speed for each fan: 4000 ±100 RPM • Rated power for each fan: 3.24 W One slim type optical drive 482.6 x 177 x 346.35 (mm, W x H x D, w/ handle) 14.5 kg/31.9 lbs (including 250 W redundant power supply and backplane) 0˚C to 50˚C -20˚C to 80˚C 5% to 95%, non-condensing 15 G peak-to-peak, 11 ms duration, non-operation Non-operation: 1.88 Grms, 5-500 Hz, each axis Operation: 0.5 Grms, 5-500 Hz, each axis, tested with 2.5” HDD Designed for NEBS Level 3 Recommended Configurations CPU Board (System slot) Rear I/O Board cPCI-6615, cPCI-6615D cPCI-R6002 cPCI-6510, cPCI-6510V cPCI-R6002, cPCI-R6100, cPCI-R6110, cPCI-R6210, cPCI-R6700 cPCI-6880, cPCI-6880P cPCI-R6002, cPCI-R6000P, cPCI-R6100, cPCI-R6110, cPCI-R6700 cPCI-6210, cPCI-6210D cPCI-R6002, cPCI-R6100, cPCI-R6110, cPCI-R6700 Ordering Information Model Number cPCI Bus PSU Type CMM PSU MAX AC/DC H.110 CD/DVD ROM 2.5 HDD Rack 3.5 HDD Rack 5.25 HDD Rack Alarm Board cPCIS-6418U/AC/ SDVD 64-bit/66MHz AT -- 3x 250W 2x AC Y 1x SATA DVD -- -- -- Basic Alarm Module cPCIS-6418U/ 2AC/SDVD 64-bit/66MHz AT -- 2x 250W 2x AC Y 1x SATA DVD -- -- -- Basic Alarm Module cPCIS-6418U/ AC3/VA(EA) 64-bit/66MHz AT -- 3x 250W 1x AC Y 1x SATA DVD -- -- -- Buzzer, RS-232 cPCIS-6418U/DC/ SDVD 64-bit/66MHz AT -- 3x 250W (DC 48V) 2x DC Y 1x SATA DVD -- -- -- Buzzer, RS-232 Mechanical Layout Rear View Replaceable Fan Tray for exhaust Slim Type optical drive 500 W + 250 W Hot-swappable Power Supply Hot-swappable Fan Tray for intake with filter Dual AC Power Inlets 3-14