INTEL BXSTS100P

Product Brief
Intel® Server Board S5500WB
Intel® Server System SR1690WB
Intel® Server System SR1695WB
Intel® Server Board S5500WB
Intel® Server System SR1690WB
Intel® Server System SR1695WB
Rack-optimized server products, purpose-built for high energy efficiency
and lowest total cost of ownership in dense computing applications.
Key Features
l
l
l
l
l
l
Supports up to two Intel® Xeon® Processor
5500 or 5600 series
Highly scalable DDR3 memory (8 DIMMs)
One PCI Express* 2.0 x16 (x8 electrical) slot plus
one Intel® I/O Expansion Module (PCI Express 2.0 x8)
Flexible storage controller options
Designed with state-of-the-art power and cooling optimizations for demanding data-center performance and reduced energy consumption
Optimized for low TCO with policy-based power management through Intel® Intelligent Power Node Manager and integrated DCMI / IPMI 2.0 manageability
Target Applications: High-density computing environments where energy costs
and total cost of ownership are paramount such as Internet portal data centers, cloud
computing and High Performance Computing (HPC).
Board Features and Benefits
• Support for one or two Intel® Xeon® Processor 5500 or 5600 series Increase server performance with no increase in
power consumption
• Power efficient board architecture with optimized voltage regulator designs and a specialized layout for efficient cooling
Voltage-regulator optimization reduces the excess heat produced by inefficient and wasteful power conversion and a spread-core
lay-out allows lower fan speeds, reducing the power used to move air across the board. Together these optimizations reduce
power consumption
• Fast, scalable and energy-efficient DDR3 memory Eight, registered or unbuffered DIMMs at up to 1333 MHz, and 6 memory
channels ensure energy-efficient performance for any application
• Expandable I/O architecture One PCIe 2.0 slot plus an optional Intel® I/O Expansion Module provide maximum flexibility in 1U rack
mount applications
• Multiple storage controller options Six integrated 3 Gbps SATA ports or optional SAS via Intel® I/O Expansion Modules with either
SAS or SAS RAID support maximize storage flexibility without consuming the PCI Express slot
System Features and Benefits
• Purpose built, 1U rack server chassis Energy efficient design optimized for integration with Intel® Server Board S5500WB
• High efficiency power-supply options Systems with either a 650-watt high efficiency (80 Plus) power supply or 450-watt high
efficiency AC or DC (1+0) or redundant (1+1) power supply configurations, all PMBus capable supporting Intel® Intelligent Power
Node Manager for policy-based power capping to enable increased rack densities and improved data center utilization
• Optimized fan speed control & thermal solutions BIOS optimizations include custom fan speed control that enables slower fan
speeds, reducing system power requirements, saving energy and reducing TCO
• Flexible storage configuration Four hot swap SAS/SATA drive bays supporting either 3.5” or 2.5” HDD in the same drive carrier,
providing the flexible storage configurations you need
Technology that Defines Innovation
Intel server technologies provide powerful capabilities designed
to make Intel® Server Products more reliable, more efficient,
more available, and easier to service. These innovative technologies are seamlessly integrated into Intel® Server Products
to complement the capabilities of the latest generation Intel®
Xeon® processor and chipset technologies.
Intel SpeedStep® Technology Dynamically adjusts processor
core frequency and voltages which can in turn reduce power
consumption and reduce operating costs for data centers
Intel® Active Airflow Control Operates chassis fans at the
minimum speed required to cool the system, reserving additional
speed for those times when ambient conditions or high workloads require it
Intel® Server Management Allows increased IT efficiency
with a combination of hardware and software products that
streamline the deployment and management of servers
According to the Climate Savers Computing Initiative, the typical server wastes 30-40% of its input
power. This wasted power is given off as heat in the data center which adds significantly to the air
conditioning load of the data center and makes the true cost of ownership of inefficient servers much
higher than just the power it consumes. In a traditional data center, each Watt of power dissipated
requires an additional Watt of electricity in air handling and chilling, so the impact can be doubled.
http://www.climatesaverscomputing.org/about/faq/
0% (Active Idle)
74
32W Savings
106
L O A D
%
UP TO 30% WALL POWER SAVINGS1
248
100%
42W Savings
0
290
50
100
150
200
250
300
350
Wall Power ( Wat t s)
Intel® Server Board S5500WB
Intel® Server Board S5520UR
An optimized system built around the Intel® Server Board S5500WB saves 32W at the wall over a typical 1U server such as the
Intel® Server System SR1600UR. This equates to total data center power savings of 64W (in a typical data center with PUE of
2.0)2 Over a four year life, with electricity cost of $0.10 per KWh, that would amount to over $224 in power costs saving for
each server deployed.3
Intel® ESAA Makes it Easy
Getting components from different vendors to work seamlessly in a single, reliable solution can be a challenge. The Intel® Enabled
Server Acceleration Alliance (Intel® ESAA) gives system builders access to pre-verified solution configuration guides (“recipes”) for
Intel® Server Products that are jointly developed with ISVs around the globe. Applications include HPC, virtualization, storage, backup
and recovery, database, and more.
Available exclusively for Intel® Server Products, Intel® ESAA recipes provide detailed hardware and software requirements and comprehensive configuration and deployment instructions to help meet complex customer requirements rapidly.
For added customer confidence, resellers can request a certificate stating that Intel and the application vendor stand behind their
branded Intel Server Product-based solution. VMware, Red Hat, Citrix, and EMC solutions may also qualify for free pass-through
branded system certification and listing on the vendor’s Hardware Compatibility List (HCL).
Intel® Cluster Ready (ICR) Certification is also available for the Intel® Server Board S5500WB family of products. The ICR program
defines a common basis for clusters in collaboration with OEMs, channel members, and ISVs. Intel ESAA offers recipes that detail the
configuration of HPC clusters on Intel® Server Products for validation with ICR tools.
Available recipes for the Intel® Server Board S5500WB, Intel Server System SR1690WB and Intel Server System SR1695WB include:
High-Performance Computing (HPC) Deployments:
• Platform Cluster Manager* 1.2 and Intel® Cluster Ready Configuration on Red Hat Enterprise Linux* 5.3
• QLogic TrueScale InfiniBand* HPC Cluster on Linux*
• Voltaire InfiniBand* Interconnect for Linux* HPC Cluster:
OS Certifications:
• Oracle Enterprise Linux* 5.3
• Red Hat Enterprise Linux* 5.3
• Red Hat Enterprise Linux* 5.3 with Integrated Virtualization
Pass Through System Certifications:
• VMware Infrastructure 3 for ESX* 3.5
• VMware vSphere 4 for ESX* 4.0/ ESXi 4.0 Installable*
• EMC* Storage
• Citrix XenServer* 5.5
With help from the Intel ESAA program, you can get to market early with leading-edge solutions based on
the Intel® Server Board S5500WB family of products— and stay ahead of the competitive curve.
For more information go to: www.intel.com/go/esaa
Intel® Server Board S5500WB Technical Specifications
Form Factor
SSI EEB (12” x 13”)
Processor
Supports one or two Intel® Xeon® Processor 5500 or 5600 series 4
Chipset
Intel® 5500 chipset with Intel® ICH10R
Intel® Quick Path Technology
4.8GT/s, 5.86GT/s and 6.4GT/s
Memory Capacity
Eight DDR3 DIMM sockets (Registered or Unbuffered)
l Six channel native (800/1066/1333MHz)
Storage
l
l
Intel® RAID Support
Six SATA ports (3 Gbps) via ICH10R with Intel® Embedded Server RAID Technology
Modular four-port SAS and SAS RAID options via Intel® I/O Expansion Module
Integrated SATA
l Intel® Embedded Server RAID Technology with host-based SW RAID levels 0/1/10
Optional SW RAID 5 with activation key
Optional internal SAS modules do not consume a valuable PCI slot like a traditional add-in card:
l Intel® SAS Module AXX4SASMOD with RAID 0, 1, 1E, 10, and optional host-based SW RAID 5
l Intel® RAID Controller SROMBSASMR with RAID 0, 1, 5, 6, 10, 50 and 60 and optional Intel® RAID Smart Battery
Validated with Intel® RAID Controllers5
Expansion Slots
Up to two expansion slots in a 2U chassis:
l 1 PCI Express* 2.0 x8 slot (x16 mechanical)
l 1 PCI Express 2.0 x4 slot (x8 mechanical)
One expansion slot in a 1U chassis:
l 1 PCI Express 2.0 x8 slot (x16 mechanical)
Either 1U or 2U chassis can also accommodate one Intel I/O Expansion Module (PCI Express 2.0 x8)
Optional Intel® I/O Expansion Modules include:
l 4 port external or internal SAS (based on LSI* 1064e)
l 4 port internal SAS RAID (see Intel® RAID Support above)
l Dual-port 10 Gigabit Ethernet
l Dual and Quad-port Gigabit Ethernet
l InfiniBand* (Mellanox*)
Integrated LAN
Embedded Intel® Dual Gigabit Controller 82576EB with support for Intel® Virtualization Technology6
Integrated Graphics
Server Engine* LLC Pilot II* Controller with 64 MB DDR2 memory, 8MB allocated to graphics
Management Hardware
Integrated IPMI 2.0 Baseboard Management Controller
l Fan speed control
l Diagnostic LEDs
l Temperature monitoring and recovery
l SMASH CLP (command line interface)
l Email alerting
l Power management with Intel® Intelligent Power Node Manager
l Support for the Data Center Manageability Interface (DCMI 1.0)
Optional Intel® Remote Management Module
l KVM & Virtual Media redirection
l Dedicated 3rd NIC
l Remote Power on/off
l Embedded Web UI
l Event log and configuration
Management Software
Intel® Deployment Assistant
l Wizard based UI to deploy, configure and update server
l BIOS, BMC and RAID array configuration
l Unattended OS install
l Online patch updates
Intel® Server Management Software
l View critical or warning events
l Power on/off/reset
l View sensor (fan speeds, temperature, power)
l Full IPMI 2.0 interface
l Chassis Intrusion detection
l Serial Over LAN (Text Console Redirection)
Chassis
Intel® Server System SR1690WB or SR1695WB
See support.intel.com for 3rd party chassis option
Purpose-built Energy Efficiency in Dense Computing Applications
SR1690WB
Intel® Server System SR1690WB Technical Specifications
Order Code
SR1690WB
SR1690WBNA
Form Factor
1U Rack
Server Board
S5500WB
Drive Bays
Four hot-swap SAS/SATA drive bays supporting either 3.5” or 2.5” HDDs in the same drive carrier
System Cooling
Four non-redundant fans
Power Supply
650-watt non-redundant high efficiency (80 Plus) PMBus capable
Add-in Card Support
One PCI Express* 2.0 x8 through riser card
I/O Expansion Module Support
Yes7
Dimensions
(H x W x D)
1.7” x 17” x 26”
(43mm x 432mm x 659mm)
Components Included
l
Intel® Server Board S5500WB
Intel® Server Chassis SR1690
l 650-watt non-redundant power supply
l One PCI Express* riser card
l Four 3.5” hard drive carriers
l Pre-routed cables
l Hot-swap SATA/SAS backplane
l Four high-speed fans
l
Management Hardware
Integrated IPMI 2.0 baseboard management controller
Optional Intel® Remote Management Module
Management Software
Intel® Deployment Assistant
Intel® Server Management Software
Redundant AC or DC Power Supply Options in High Efficiency 1U Chassis
SR1695WB
Intel® Server System SR1695WB Technical Specifications
Order Code
SR1695WB
SR1695WBNA
Form Factor
1U Rack
Server Board
S5500WB
Drive Bays
Four hot-swap SAS/SATA drive bays supporting either 3.5” or 2.5” HDDs in the same drive carrier
System Cooling
Four non-redundant fans
Power Supply
AC or DC 450-watt non-redundant (1+0) or redundant (1+1) high efficiency (80 Plus) PMBus capable
Add-in Card Support
One PCI Express* 2.0 x8 through riser card
I/O Expansion Module Support
Yes7
Dimensions
(H x W x D)
1.7” x 17.75” x 26.5”
(43mm x 451mm x 673mm)
Components Included
l
Intel® Server Board S5500WB
Intel® Server Chassis SR1695
l 450-watt AC or DC power supply options
l One PCI Express* riser card
l Four 3.5” hard drive carriers
l Pre-routed cables
l Hot-swap SATA/SAS backplane
l Four high-speed fans
l
Management Hardware
Integrated IPMI 2.0 baseboard management controller
Optional Intel® Remote Management Module
Management Software
Intel® Deployment Assistant
Intel® Server Management Software
Safety and EMC Regulatory Compliance
Regulatory compliance for an Intel host system is based on the use of an Intel server base board that was tested in the host chassis and found compliant. Intel
server base boards and host chassis are tested to Class A EMC requirements. Intel server products comply with RoHS (Restriction of Hazardous Substances).
Region (Compliance Obtained)
Board Markings
Argentina (IRAM)
Host Chassis Markings
Regulation N/A
Australia (ACA) / New Zealand (MED)
Belarus
Regulation N/A
Canada
ICES-003
Europe (EU Directives) - LVD & EMC require CE
mark; No mark required for RoHS; WEEE marking
added voluntarily for end integrator convenience
Germany GS for Chassis Only; German Green Dot (Duales System
Deutschland) for Board Packaging Only
International Compliance (CB Report &
CISPR Emission & Immunity)
Marking Not Required
Japan (VCCI for chassis only) & Japan Recycling Marks on Board Retail
Packaging Only
Regulation N/A
Marking Not Required
Korea (KCC)
Russia (GOSSTANDART)
Regulation N/A
Taiwan (BSMI)
Ukraine (UKRTEST)
United States NRTL & FCC (For Board Products FCC Notation May Be in
Documentation)
Regulation N/A
Marking Not Required
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation
Select compatible components for a complete server system: www.intel.com/go/serverconfigurator
Why choose Intel® Server Products? Quality, flexibility, support. Learn more: www.intel.com/go/serverproducts
1
Power benchmark data from SPECpower_ssj2008. http://www.spec.org/specpower/ Measurements were taken on pre-production systems (January 2009) that were configured with identical memory, processors and hard disk drive, operating system and JVM. Variables were fan configuration, cooling duct design, fan speed control and power supply wattage and efficiency rating.
2
PUE = Power Usage Effectiveness. A PUE of 2.0 means that for every 2 watts in at the utility meter, only one watt is delivered out to the IT load (the server in this case). PUE ratio of 2.0 is the average value across all U.S. data centers. Source: http://www.energystar.gov/ia/partners/prod_development/downloads/EPA_Datacenter_Report_Congress_Final1.pdf
3
Calculation backup: 32W x 4 years x 365 days x 24 hours/1000 = 1,121 Kilo Watt Hours (KWh). At a PUE of 2.0, that becomes 2,241 KWh x $0.10/ KWh = $224.
4
When installing two processors, both processors must be from the same processor series; either two Intel® Xeon® processor 5500 series or two Intel® Xeon® processor 5600 series. Out of the box support for the Intel Xeon 5600 series processors will be indicated by the addition of the letter “R” at the end of the Product Order Code. For boards and systems currently supporting the Intel Xeon 5500 series, a BIOS update is required before installing the 5600 series processor(s). Refer to http://support.intel.com for more information.
5
For tested Intel® RAID Controller options go to http://support.intel.com/support/motherboards/server/compat_matrix.htm
6
Intel® Virtualization Technology requires a computer system with an enabled Intel® processor, BIOS, virtual machine monitor (VMM) and, for some uses, certain computer system software enabled for it. Functionality, performance or other benefits will vary depending on hardware and software configurations and may require a BIOS update. Software applications may not be compatible with all operating systems. Please check with your application vendor.
7
For optional Intel® I/O Modules go to http://www.intel.com/products/server/io/index.htm
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR
OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL’S TERMS AND CONDITIONS
OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING
TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
UNLESS OTHERWISE AGREED IN WRITING BY INTEL, THE INTEL PRODUCTS ARE NOT DESIGNED NOR INTENDED FOR ANY APPLICATION IN WHICH THE
FAILURE OF THE INTEL PRODUCT COULD CREATE A SITUATION WHERE PERSONAL INJURY OR DEATH MAY OCCUR.
Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or
instructions marked “reserved” or “undefined.” Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising
from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information.
The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications.
Current characterized errata are available on request.
Intel, the Intel logo, Xeon, Xeon Inside, and Intel SpeedStep are trademarks of Intel Corporation in the U.S. and other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 2010 Intel Corporation. All rights reserved. 1210/JH/MD/PDF 322342-004US