SAFT BA5360

Primary lithium battery system
BA 5360
9 V Primary lithium manganese dioxide (Li-MnO2) battery
The battery consists of 3 LM 33550 cells
connected in series
Key Features
■■ A non-replaceable fuse is
incorporated in the battery
■■ A normally closed thermal fuse (TCO)
is incorporated in the battery. It is
non-replaceable and non-resettable
■■ A blocking diode is incorporated in the
battery to prevent charging
■■ A non-replaceable fuse is connected
between two of the cells for added
safety
■■ A complete discharge device (CDD)
with LED activation indicator is built
into the battery. The CDD consists of a
manually activated switch to connect a
resistor for discharging to 0V.
■■ Made in the USA
Typical applications
■■ AN/PSC-2 Communications Terminal
■■ AN/MLQ36 Mobile Support System
■■ MU/848/PSC-2
Electrical charachteristics
Typical OCV
Nominal voltage (at 500 mA)
Cut-off voltage (V)
Typical capacity at 21°C/70°F
(at 250mA discharge current)
Operating temperature
Storage temperature
Recommended max
Possible
Physical characteristics
Maximum weight
Weight of Li metal content
Max OD
Max length
Battery case
References
Reference specifications
Nato stock number
9V
8V
6V
13 Ah
-40°C to 71°C/-40°F to +160°F
35°C/95°F
-40°C to 71°C/-40°F to +160°F
Metric
Imperial
540 g
1.2 lb
11.1 g
0.4 oz
39.62 mm 1.56 in
186.31 mm 7.335 in
plastic
MIL PRF 32271
Saft Standard Specification
6135-01-517-4955
BA 5360
BA 5360 dimensions
0.178± .10 mm
(0.007±0.004 in)
TYP 2PL
Volts
3.68± .25 mm
(0.145±0.010 in)
185.93± .38 mm
(7.320±0.015 in)
19.05± .25 mm
(0.750±0.010 in)
9.53± .13 mm
(0.375±0.005 in)
8.76± .25 mm
(0.345±0.010 in)
39.37± .25 mm
(1.550±0.010 in)
17.53± .51 mm
(0.69±0.02 in)
10.41± .13 mm
(0.410±0.005 DIA in)
13.21± .51R mm
(0.52±0.020R in)
5A
Fuse
LED
CDD
Switch
Constant
Discharge
Device
3A
Thermal
Fuse Fuse
Voltage
+9V
-20C
100
0C
21 C
54 C
71C
1000
10000
Current Discharge in mA
Schottky
Diode
Typical discharge curves at 21°C at various discharge currents
9.2
9.0
8.8
8.6
8.4
8.2
8.0
7.8
7.6
7.4
7.2
7.0
6.8
6.6
6.4
6.2
6.0
2A
1A
500mA
250mA
100mA
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Capacity(Ah)
14
Capacity in Amp-Hrs
+9V
-30 C
10
Electrical schematic
R1
Voltage plateau vs. current and temperature
9.0
8.8
8.6
8.4
8.2
8.0
7.8
7.6
7.4
7.2
7.0
6.8
6.6
6.4
6.2
6.0
Capacity vs. discharge and temperature
13
-30 C
12
-20C
11
0C
10
9
21 C
8
54 C
7
71 C
6
5
4
3
2
1
10
100
1000
Current Discharge in mA
Saft
12, rue Sadi Carnot
93170 Bagnolet France
Tel.: +33 (0)1 49 93 19 18
Fax: +33 (0)1 49 93 19 69
www.saftbatteries.com
Saft America, Inc.
313 Crescent St.
Valdese, NC 28690 - USA
Tel.: +1 (828) 874 4111
Fax: +1 (828) 874 3981
www.saftbatteries.com
Doc N°32041-2-0313
Edition: March 2013
Information in this document is subject to change
without notice and becomes contractual only after
written confirmation by Saft.
Published by the Communications Department
Photo credit: Saft
10000