SAFT BA5600A

Li-SO2 primary battery system
BA 5600 A/U
Assembled from 3 LO 26 SX cells
connected in series.
Key features
• A non-replaceable fuse is
incorporated in the negative leg.
• A normally closed thermal fuse
(TCO) is incorporated in the
battery. It is non-replaceable
and non-resetable.
Electrical Characteristics
Typical OCV (V)
9.0
Nominal voltage (at 500mA) (V)
8.1
Cut-off (V)
4.0
Typical Capacity +21 °C / + 70 °F
7.5
• A diode is incorporated to
prevent charging or flow of
current into the battery.
(at 250 mA discharge current)
• A device consisting of a
manually activated switch and
resistor designed to discharge
the battery to 0 V is built into
the battery.
Storage
• Made in the USA
Typical applications
• AN/PSC-2
Communications
Terminal
Operating temperature
-40° C to 71° C
-40° F to 160° F
Recommended max
Possible
+35°C/ +95°F
-40° C to 71° C / -40° F to 160° F
Physical Characteristics
Typical Weight (g/oz)
360 / 12.7
Weight of Li metal content (g/oz)
7.2 / 0.25
Max. Width (mm/ in)
39 / 1.56
Max. Height (mm/ in)
186 / 7.34
Max. Depth (mm/ in)
Battery Case
Plastic
References
Reference specifications
NSN Reference
March 2006
MIL PRF 49471B (CR) or Saft Standard Specifications
6135-01-168-2944
BA 5600 A/U dimensions
Capacity vs rate at various temperatures
Capacity (Ah)
*All measurements in inches
Voltage (V)
2 A discharge typical curves at various temperatures
Typical discharge curves at various rates at +21ºC/+70ºF
Voltage (V)
Electrical schematic
Saft
Specialty Battery Group
12, rue Sadi Carnot
93170 Bagnolet - France
Tel: +33 (0)1 49 93 19 18
Fax: +33 (0)1 49 93 19 69
Doc N° 31070-2-0306
313 Crescent Street
Valdese NC 28690 - USA
Tel: +1 (828) 874 4111
Fax: +1 (828) 874 2431
www.saftbatteries.com
Data in this document is subject to change without notice and
becomes contractual only after written
confirmation.