SAFT BA5590A

Li-SO2 primary battery system
BA 5590 A/U
With state of charge indicator (SOCI)
10 LO 26 SX cells connected in
2 groups of 5 cells in series providing
2 nominal 12 V sections at connector.
These sections can be connected in
series (for 24 V) in parallel (for 12 V)
or used as two separate 12 V units.
Key features
• A non-replaceable fuse is
incorporated in the negative leg of
each series group of cells.
• A normally closed high temperature
switch or thermal fuse is incorporated
into each series group of cells to
protect against overheating.
• A diode is incorporated into each
series group of cells to prevent
charging or flow of current into
the battery.
• A device consisting of a manually
activated pull tab and resistors
designed to discharge the battery
to 0 V is built into the battery.
Electrical characteristics
Typical OCV (V)
15.0 or 30.0
Nominal voltage (at 500 mA) (V)
13.5 or 27.0
Cut-off (V)
10.0 or 20.0
Typical capacity +21°C/+70°F
15 Ah at 12 V
(at 250 mA discharge current)
7.5 Ah at 24 V
Operating temperature
Storage
• A microprocessor based state of
charge indicator shows the
remaining capacity. The SOCI includes
a LED display and push button
activation. The SOCI is discharge rate
and temperature compensated.
Typical applications
• AN/PRC-104 Radio
Recommended max
Possible
–40°C to +71°C
–40°F to +160°F
+35°C / +95°F
–40°C to +71°C / – 40°F to +160°F
Physical characteristics
Typical Weight (g/oz)
Weight of Li metal content (g/oz)
1000 / 35.3
24 / 0.85
Width (mm/in)
62.2 / 2.45
Height (mm/in)
111.8 / 4.40
Depth (mm/in)
127.0 / 5.00
Battery Case
Plastic
• AN/PRC-113 Radio
• AN/PRC-117 Radio
References
• AN/PRC-119 Singcars Radio
Mating connector
• KY-57, KY-65 Encryption Set
Reference specifications
• REMBASS Remotely Monitored
Battlefield Surveillance System
NSN reference
• PLRS Position Locator and
Reporting System
• RT-991 Buoy Radio
• RT-1175 Buoy Radio
• AN/TAS-4A TOW Night Sight
September 2006
ITT Cannon CA 110821- 6
MIL PRF 49471B or Saft Standard Specification
6135– 01–523–3037
BA 5590 A/U dimensions
Capacity vs rate at various temperatures
9
Capacity (Ah)
8
+21°C
7
+54°C
0°C
6
–30°C
5
–40°C
4
3
0
1
2
3
Discharge rate (A)
2 A discharge typical curves at various temperatures (24 V mode)
30
29
28
Voltage (V)
27
26
+54°C
25
+21°C
24
23
0°C
22
–30°C
21
–40°C
20
0
1
2
3
4
5
6
7
8
Discharge capacity (Ah)
Electrical schematic
Typical discharge curves at various rates at +21°C/+70°F
30
29
28
Voltage (V)
27
26
0.25A
25
0.5A
24
1A
2A
23
22
21
20
0
1
2
3
4
5
6
Discharge capacity (Ah)
Saft
Specialty Battery Group
12, rue Sadi Carnot
93170 Bagnolet - France
Tel: +33 (0) 1 49 93 19 18
Fax: +33 (0) 1 49 93 19 69
Doc N° 31076-2-0906
313 Crescent Street
Valdese, NC 28690 - USA
Tel: +1 (828) 874 4111
Fax: +1 (828) 874 3981
www.saftbatteries.com
Data in this document is subject to change without
notice and becomes contractual only after written
confirmation.
Société anonyme au capital de 31 944 000 €
RCS Bobigny B 383 703 873
Pragma - Printed in France
7
8
9