Li-SO2 primary battery system BA 5590 A/U With state of charge indicator (SOCI) 10 LO 26 SX cells connected in 2 groups of 5 cells in series providing 2 nominal 12 V sections at connector. These sections can be connected in series (for 24 V) in parallel (for 12 V) or used as two separate 12 V units. Key features • A non-replaceable fuse is incorporated in the negative leg of each series group of cells. • A normally closed high temperature switch or thermal fuse is incorporated into each series group of cells to protect against overheating. • A diode is incorporated into each series group of cells to prevent charging or flow of current into the battery. • A device consisting of a manually activated pull tab and resistors designed to discharge the battery to 0 V is built into the battery. Electrical characteristics Typical OCV (V) 15.0 or 30.0 Nominal voltage (at 500 mA) (V) 13.5 or 27.0 Cut-off (V) 10.0 or 20.0 Typical capacity +21°C/+70°F 15 Ah at 12 V (at 250 mA discharge current) 7.5 Ah at 24 V Operating temperature Storage • A microprocessor based state of charge indicator shows the remaining capacity. The SOCI includes a LED display and push button activation. The SOCI is discharge rate and temperature compensated. Typical applications • AN/PRC-104 Radio Recommended max Possible –40°C to +71°C –40°F to +160°F +35°C / +95°F –40°C to +71°C / – 40°F to +160°F Physical characteristics Typical Weight (g/oz) Weight of Li metal content (g/oz) 1000 / 35.3 24 / 0.85 Width (mm/in) 62.2 / 2.45 Height (mm/in) 111.8 / 4.40 Depth (mm/in) 127.0 / 5.00 Battery Case Plastic • AN/PRC-113 Radio • AN/PRC-117 Radio References • AN/PRC-119 Singcars Radio Mating connector • KY-57, KY-65 Encryption Set Reference specifications • REMBASS Remotely Monitored Battlefield Surveillance System NSN reference • PLRS Position Locator and Reporting System • RT-991 Buoy Radio • RT-1175 Buoy Radio • AN/TAS-4A TOW Night Sight September 2006 ITT Cannon CA 110821- 6 MIL PRF 49471B or Saft Standard Specification 6135– 01–523–3037 BA 5590 A/U dimensions Capacity vs rate at various temperatures 9 Capacity (Ah) 8 +21°C 7 +54°C 0°C 6 –30°C 5 –40°C 4 3 0 1 2 3 Discharge rate (A) 2 A discharge typical curves at various temperatures (24 V mode) 30 29 28 Voltage (V) 27 26 +54°C 25 +21°C 24 23 0°C 22 –30°C 21 –40°C 20 0 1 2 3 4 5 6 7 8 Discharge capacity (Ah) Electrical schematic Typical discharge curves at various rates at +21°C/+70°F 30 29 28 Voltage (V) 27 26 0.25A 25 0.5A 24 1A 2A 23 22 21 20 0 1 2 3 4 5 6 Discharge capacity (Ah) Saft Specialty Battery Group 12, rue Sadi Carnot 93170 Bagnolet - France Tel: +33 (0) 1 49 93 19 18 Fax: +33 (0) 1 49 93 19 69 Doc N° 31076-2-0906 313 Crescent Street Valdese, NC 28690 - USA Tel: +1 (828) 874 4111 Fax: +1 (828) 874 3981 www.saftbatteries.com Data in this document is subject to change without notice and becomes contractual only after written confirmation. Société anonyme au capital de 31 944 000 € RCS Bobigny B 383 703 873 Pragma - Printed in France 7 8 9