Li-SO2 primary battery system BA 5599 A/U Assembled from 3 LO 26 SX cells connected in series. Key features • A non-replaceable fuse is incorporated in the negative leg. • A normally closed thermal fuse (TCO) is incorporated in the battery. It is non-replaceable and non-resetable. • A diode is incorporated to prevent charging or flow of current into the battery. Electrical Characteristics Typical OCV (V) 9.0 Nominal voltage (at 500mA) (V) 8.1 Cut-off (V) 6.0 Typical Capacity (Ah) +21 °C / + 70 °F 7.5 (at 250 mA discharge current) Operating temperature -40° C to 71° C -40° F to 160° F • A device consisting of a manually activated switch and resistor designed to discharge the battery to 0 V is built into the battery. Storage Typical Weight (g/oz) 450 / 15.9 • Made in the USA Weight of Li metal content (g/oz) 7.2 / 0.25 Typical applications • AN/PAS-9 • AN/PAS-6 Mine Detector Metascope Recommended max Possible +35°C/ +95°F -40° C to 71° C / -40° F to 160° F Physical Characteristics Max. Width (mm/ in) 152 / 6.0 Max. Height (mm/ in) 64 / 2.5 Max. Depth (mm/ in) 38 / 1.5 Battery Case Plastic References Mating Connector Reference specifications NSN Reference March 2006 ITT Cannon CA110821-6 MIL PRF 49471B (CR) or Saft Standard Specifications 6135-01-069-8575 BA 5599 A/U dimensions Capacity vs rate at various temperatures Voltage (V) *All measurements in inches Voltage (V) 2 A discharge typical curves at various temperatures Typical discharge curves at various rates at +21ºC/+70ºF Voltage (V) Electrical schematic Saft Specialty Battery Group 12, rue Sadi Carnot 93170 Bagnolet - France Tel: +33 (0)1 49 93 19 18 Fax: +33 (0)1 49 93 19 69 Doc N° 31068-2-0306 313 Crescent Street Valdese NC 28690 - USA Tel: +1 (828) 874 4111 Fax: +1 (828) 874 2431 www.saftbatteries.com Data in this document is subject to change without notice and becomes contractual only after written confirmation.