January 2000 COP888EK 8-Bit CMOS ROM Based Microcontrollers with 8k Memory, Comparator, and Single-slope A/D Capability General Description The COP888EK ROM based microcontrollers are highly integrated COP8™ Feature core devices with 8k memory and advanced features including a Multi-Input Comparator and Single-slope A/D capability. These single-chip CMOS devices are suited for applications requiring a full featured, low EMI controller with an analog comparator, current source, and voltage reference. The COP87L88EK/RK Family devices are pin and software compatible (different VCC range) 16k or 32k OTP (One Time Programmable) versions for preproduction, and for use with a range of COP8 software and hardware development tools. Device Memory (bytes) RAM (bytes) I/O Pins Family features include an 8-bit memory mapped architecture, 10 MHz CKI with 1µs instruction cycle, three multifunction 16-bit timer/counters with PWM, MICROWIRE/ PLUS™ serial I/O, one analog comparator with seven input multiplexor, an analog current source and VCC reference, two power saving HALT/IDLE modes, idle timer, MIWU, high current outputs, software selectable I/O options, WATCHDOG™ timer and Clock Monitor, Low EMI 2.5V to 6.0V operation and 28/40/44 pin packages. Devices included in this datasheet are: Packages Temperature Comments COP684EK 8k ROM 256 24 28 DIP/SOIC -55 to +125˚C 4.5V - 5.5V COP884EK 8k ROM 256 24 28 DIP/SOIC -40 to +85˚C COP984EK 8k ROM 256 24 28 DIP/SOIC 0 to +70˚C COP688EK 8k ROM 256 36/40 40 DIP, 44 PLCC -55 to +125˚C 4.5V - 5.5V COP888EK 8k ROM 256 36/40 40 DIP, 44 PLCC -40 to +85˚C COP988EK 8k ROM 256 36/40 40 DIP, 44 PLCC 0 to +70˚C 2.5V - 4.0V, EKH=4.0V - 6.0V 2.5V - 4.0V, EKH=4.0V - 6.0V Key Features CPU/Instruction Set Feature n Analog function block with — Analog comparator with seven input multiplexor — Constant current source and VCC/2 reference n Three 16-bit timers, each with two 16-bit registers supporting: — Processor Independent PWM mode — External Event counter mode — Input Capture mode n 8 kbytes of on-chip ROM n 256 bytes of on-chip RAM n 1 µs instruction cycle time n Twelve multi-source vectored interrupts servicing — External Interrupt with selectable edge — Idle Timer T0 — Three Timers (Each with 2 interrupts) — MICROWIRE/PLUS — Multi-Input Wake Up — Software Trap — Default VIS (default interrupt) n Versatile and easy to use instruction set n 8-bit Stack Pointer (SP) — stack in RAM n Two 8-bit Register Indirect Data Memory Pointers (B, X) Additional Peripheral Features n n n n Idle Timer Multi-Input Wake Up (MIWU) with optional interrupts (8) WATCHDOG and Clock Monitor logic MICROWIRE/PLUS serial I/O I/O Features Fully Static CMOS n Single supply operation: 2.5V to 6.0V n Temperature ranges: 0˚C to +70˚C, −40˚C to +85˚C, and −55˚C to +125˚C n Software selectable I/O options (TRI-STATE™ Output, Push-Pull Output, Weak Pull-Up Input, High Impedance Input) n High current outputs n Schmitt trigger inputs on Port G and L n Packages: 44 PLCC with 40 I/O pins, 40 DIP with 36 I/O pins, and 28 DIP/SO with 24 I/O pins COP8™, MICROWIRE/PLUS™, and WATCHDOG™ are trademarks of National Semiconductor Corporation. TRI-STATE ® is a registered trademark of National Semiconductor Corporation. iceMASTER ® is a registered trademark of MetaLink Corporation. © 2000 National Semiconductor Corporation DS012094 www.national.com COP888EK 8-Bit CMOS ROM Based Microcontrollers with 8k Memory, Comparator, and Single-slope A/D Capability OBSOLETE COP888EK n Real time emulation and full program debug offered by MetaLink Development System Development Support n Emulation and OTP devices Block Diagram DS012094-1 FIGURE 1. Block Diagram www.national.com 2 COP888EK Connection Diagrams Plastic Chip Carrier Dual-In-Line Package DS012094-2 Top View Order Number COP688EK-XXX/V, COP888EK-XXX/V, COP988EK-XXX/V or COP988EKH-XXX/V See NS Plastic Chip Package Number V44A DS012094-3 Top View Order Number COP688EK-XXX/N, COP888EK-XXX/N, COP988EK-XXX/N or COP988EKH-XXX/N See NS Molded Package Number N40A Dual-In-Line Package DS012094-4 Top View Order Number COP684EK-XXX/N, COP884EK-XXX/N, COP984EK-XXX/N or COP984EKH-XXX/N See NS Molded Package Number N28B Order Number COP684EK-XXX/WM, COP884EK-XXX/WM, COP984EK-XXX/WM or COP984EKH-XXX/WM See NS Molded Package Number M28B FIGURE 2. Connection Diagrams 3 www.national.com COP888EK Connection Diagrams (Continued) Pinouts for 28-, 40- and 44-Pin Packages Port Type Alt. Fun Alt. Fun 28-Pin 40-Pin 44-Pin Pack. Pack. Pack. L0 I/O MIWU 11 17 17 L1 I/O MIWU 12 18 18 L2 I/O MIWU 13 19 19 L3 I/O MIWU 14 20 20 L4 I/O MIWU T2A 15 21 25 L5 I/O MIWU T2B 16 22 26 L6 I/O MIWU T3A 17 23 27 L7 I/O MIWU T3B 18 24 28 G0 I/O INT 25 35 39 G1 WDOUT 26 36 40 G2 I/O T1B 27 37 41 G3 I/O T1A 28 38 42 G4 I/O SO 1 3 3 G5 I/O SK 2 4 4 G6 I SI 3 5 5 G7 I/CKO HALT Restart 4 6 6 D0 O 19 25 29 D1 O 20 26 30 D2 O 21 27 31 D3 O 22 28 32 I0 I COMPIN1+ 7 9 9 I1 I COMPIN−/Current 8 10 10 I2 I COMPIN0+ 9 11 11 I3 I COMPOUT/COMPIN2+ 10 12 12 I4 I COMPIN3+ 13 13 I5 I COMPIN4+ 14 14 I6 I COMPIN5+ 15 15 I7 I COMPOUT 16 16 D4 O 29 33 D5 O 30 34 D6 O 31 35 D7 O 32 36 C0 I/O 39 43 C1 I/O 40 44 C2 I/O 1 1 C3 I/O 2 C4 I/O 21 C5 I/O 22 C6 I/O 23 C7 I/O Source Out 2 24 VCC 6 8 8 GND 23 33 37 CKI 5 7 7 RESET 24 34 38 www.national.com 4 Total Current into VCC Pin (Source) Total Current out of GND Pin (Sink) Storage Temperature Range If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. Supply Voltage (VCC) Voltage at Any Pin 100 mA 110 mA −65˚C to +140˚C Note 1: Absolute maximum ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications are not ensured when operating the device at absolute maximum ratings. 7V −0.3V to VCC + 0.3V DC Electrical Characteristics 98xEK: 0˚C ≤ TA ≤ + 70˚C unless otherwise specified Parameter Conditions Min Typ Max Units Operating Voltage COP98XEK 2.5 4.0 V COP98XEKH 4.0 6.0 V 0.1 VCC V 10.0 mA Power Supply Ripple (Note 3) Supply Current (Note 4) CKI = 10 MHz CKI = 4 MHz HALT Current (Note 5) IDLE Current (Note 4) CKI = 10 MHz CKI = 4 MHz Peak-to-Peak VCC = 6.0V, tc = 1 µs VCC = 2.5V, tc = 2.5 µs VCC = 6.0V, CKI = 0 MHz VCC = 4.0V, CKI = 0 MHz VCC = 6.0V, tc = 1 µs VCC = 2.5V, tc = 2.5 µs 1.7 mA <4 <3 8 µA 4 µA 0.4 1.7 mA 0.2 0.5 mA Input Levels (VIH, VIL) RESET Logic High 0.8 VCC Logic Low V 0.2 VCC V CKI, All Other Inputs Logic High 0.7 VCC Logic Low Hi-Z Input Leakage Input Pullup Current VCC = 6.0V VCC = 6.0V, VIN = 0V −1 −40 G and L Port Input Hysteresis (Note 8) V 0.2 VCC V +1 µA −250 µA 0.35 VCC V Output Current Levels D Outputs Source Sink VCC = 4.0V, VOH = 3.3V VCC = 2.5V, VOH = 1.8V VCC = 4.0V, VOL = 1V VCC = 2.5V, VOL = 0.4V −0.4 mA −0.2 mA 10 mA 2.0 mA VCC = 4.0V, VOH = 2.7V VCC = 2.5V, VOH = 1.8V VCC = 4.0V, VOH = 3.3V VCC = 2.5V, VOH = 1.8V −10 −110 −2.5 −33 All Others Source (Weak Pull-Up Mode) Source (Push-Pull Mode) Sink (Push-Pull Mode) VCC VCC TRI-STATE Leakage VCC = 4.0V, VOL = 0.4V = 2.5V, VOL = 0.4V = 6.0V µA µA −0.4 mA −0.2 mA 1.6 mA 0.7 −1 mA +1 µA Allowable Sink/Source Current per Pin (Note 8) D Outputs (Sink) 15 mA All others 3 mA ± 100 mA Maximum Input Current Room Temp without Latchup (Note 6) RAM Retention Voltage, Vr 500 ns Rise and Fall Time (Min) 5 2 V www.national.com COP888EK Absolute Maximum Ratings (Note 1) COP888EK DC Electrical Characteristics 98xEK: (Continued) 0˚C ≤ TA ≤ + 70˚C unless otherwise specified Parameter Conditions Min Typ Max Input Capacitance Load Capacitance on D2 Units 7 pF 1000 pF AC Electrical Characteristics 98xEK: 0˚C ≤ TA≤ + 70˚C unless otherwise specified Parameter Conditions Min Typ Max Units Instruction Cycle Time (tc) Crystal, Resonator, R/C Oscillator 4.0V ≤ VCC ≤ 6.0V 1.0 DC µs 2.5V ≤ VCC < 4.0V 2.5 DC µs 4.0V ≤ VCC ≤ 6.0V 3.0 DC µs 2.5V ≤ VCC < 4.0V 7.5 DC µs 4.0V ≤ VCC ≤ 6.0V 200 ns 2.5V ≤ VCC < 4.0V 500 ns 4.0V ≤ VCC ≤ 6.0V 60 ns 2.5V ≤ VCC < 4.0V RL = 2.2k, CL = 100 pF 150 ns Inputs tSETUP tHOLD Output Propagation Delay (Note 7) tPD1, tPD0 SO, SK All Others 4.0V ≤ VCC ≤ 6.0V 0.7 µs 2.5V ≤ VCC < 4.0V 1.75 µs 4.0V ≤ VCC ≤ 6.0V 1 µs 2.5V ≤ VCC < 4.0V 2.5 µs MICROWIRE™Setup Time (tUWS) (Note 7) VCC ≥ 4.0V 20 ns MICROWIRE Hold Time (tUWH) (Note 7) VCC ≥ 4.0V 56 ns MICROWIRE Output Propagation Delay (tUPD) VCC ≥ 4.0V 220 ns Input Pulse Width (Note 8) Interrupt Input High Time 1.0 tc Interrupt Input Low Time 1.0 tc Timer 1, 2, 3 Input High Time 1.0 tc Timer 1, 2, 3 Input Low Time 1.0 tc 1.0 µs Reset Pulse Width Note 2: tc = Instruction Cycle Time Note 3: Maximum rate of voltage change must be < 0.5 V/ms. Note 4: Supply and IDLE currents are measured with CKI driven with a square wave Oscillator, CKO driven 180˚ out of phase with CKI, inputs connected to VCC and outputs driven low but not connected to a load. Note 5: The HALT mode will stop CKI from oscillating in the RC and the Crystal configurations. Measurement of IDD HALT is done with device neither sourcing nor sinking current; with L, C, and G0–G5 programmed as low outputs and not driving a load; all outputs programmed low and not driving a load; all inputs tied to VCC; clock monitor and comparator disabled. Parameter refers to HALT mode entered via setting bit 7 of the G Port data register. Part will pull up CKI during HALT in crystal clock mode. Note 6: Pins G6 and RESET are designed with a high voltage input network. These pins allow input voltages > VCC and the pins will have sink current to VCC when biased at voltages > VCC(the pins do not have source current when biased at a voltage below VCC). The effective resistance to VCC is 750Ω (typical). These two pins will not latch up. The voltage at the pins must be limited to < 14V. WARNING: Voltages in excess of 14V will cause damage to the pins. This warning excludes ESD transients. Note 7: The output propagation delay is referenced to the end of the instruction cycle where the output change occurs. Note 8: Parameter characterized but not tested. www.national.com 6 Total Current into VCC Pin (Source) Total Current out of GND Pin (Sink) Storage Temperature Range If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. Supply Voltage (VCC) Voltage at Any Pin 100 mA 110 mA −65˚C to +140˚C Note 9: Absolute maximum ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications are not ensured when operating the device at absolute maximum ratings. 7V −0.3V to VCC + 0.3V DC Electrical Characteristics 88xEK: −40˚C ≤ TA ≤ +85˚C unless otherwise specified Parameter Conditions Operating Voltage Power Supply Ripple (Note 11) Supply Current (Note 12) CKI = 10 MHz CKI = 4 MHz HALT Current (Note 13) IDLE Current (Note 12) CKI = 10 MHz CKI = 4 MHz Min Typ Max Units 6.0 V 0.1 VCC V 10.0 mA 1.7 mA <4 10 µA 0.4 1.7 mA 0.2 0.5 mA 2.5 Peak-to-Peak VCC = 6.0V, tc = 1 µs VCC = 2.5V, tc = 2.5 µs VCC = 6.0V, CKI = 0 MHz VCC = 6.0V, tc = 1 µs VCC = 6.0V, tc = 2.5 µs Input Levels (VIH, VIL) RESET Logic High 0.8 VCC Logic Low V 0.2 VCC V CKI, All Other Inputs Logic High 0.7 VCC Logic Low Hi-Z Input Leakage Input Pullup Current VCC = 6.0V VCC = 6.0V, VIN = 0V −2 −40 G and L Port Input Hysteresis (Note 16) V 0.2 VCC V +2 µA −250 µA 0.35 VCC V Output Current Levels D Outputs Source Sink VCC = 4.0V, VOH = 3.3V VCC = 2.5V, VOH = 1.8V VCC = 4.0V, VOL = 1V −0.4 VCC = 2.5V, VOL = 0.4V mA −0.2 mA 10 mA 2.0 mA All Others Source (Weak Pull-Up Mode) Source (Push-Pull Mode) Sink (Push-Pull Mode) TRI-STATE Leakage VCC = 4.0V, VOH VCC = 2.5V, VOH VCC = 4.0V, VOH VCC = 2.5V, VOH = 2.7V = 1.8V −10 −100 −2.5 −33 µA µA = 3.3V = 1.8V −0.4 −0.2 mA VCC = 4.0V, VOL = 0.4V VCC = 2.5V, VOL = 0.4V VCC = 6.0V 1.6 mA 0.7 mA −2 mA +2 µA 15 mA 3 mA ± 100 mA Allowable Sink/Source Current per Pin (Note 16) D Outputs (Sink) All others Maximum Input Current Room Temp without Latchup (Note 14) RAM Retention Voltage, Vr 500 ns Rise 2 V and Fall Time (min) Input Capacitance 7 7 pF www.national.com COP888EK Absolute Maximum Ratings (Note 9) COP888EK DC Electrical Characteristics 88xEK: (Continued) −40˚C ≤ TA ≤ +85˚C unless otherwise specified Parameter Conditions Min Typ Load Capacitance on D2 Max Units 1000 pF Max Units AC Electrical Characteristics 88xEK: −40˚C ≤ TA ≤ +85˚C unless otherwise specified Parameter Conditions Min Typ Instruction Cycle Time (tc) Crystal, Resonator, R/C Oscillator 4.0V ≤ VCC ≤ 6.0V 1.0 DC µs 2.5V ≤ VCC < 4.0V 2.5 DC µs 4.0V ≤ VCC ≤ 6.0V 3.0 DC µs 2.5V ≤ VCC ≤ 4.0V 7.5 DC µs 4.0V ≤ VCC ≤ 6.0V 200 2.5V ≤ VCC < 4.0V 500 ns 4.0V ≤ VCC ≤ 6.0V 60 ns 2.5V ≤ VCC < 4.0V RL = 2.2k, CL = 100 pF 150 ns Inputs tSETUP tHOLD Output Propagation Delay (Note 15) ns tPD1, tPD0 SO, SK All Others 4.0V ≤ VCC ≤ 6.0V 0.7 µs 2.5V ≤ VCC < 4.0V 1.75 µs 4.0V ≤ VCC ≤ 6.0V 1.0 µs 2.5V ≤ VCC < 4.0V 2.5 µs MICROWIRE Setup Time (tUWS) (Note 15) 20 ns MICROWIRE Hold Time (tUWH) (Note 15) 56 ns MICROWIRE Output Propagation Delay (tUPD) 220 ns Input Pulse Width (Note 16) Interrupt Input High Time 1.0 tc Interrupt Input Low Time 1.0 tc Timer 1, 2, 3 Input High Time 1.0 tc Timer 1, 2, 3 Input Low Time 1.0 tc 1.0 µs Reset Pulse Width Note 10: tc = Instruction Cycle Time Note 11: Maximum rate of voltage change must be < 0.5 V/ms. Note 12: Supply and IDLE currents are measured with CKI driven with a square wave Oscillator, CKO driven 180˚ out of phase with CKI, inputs connected to VCC and outputs driven low but not connected to a load. Note 13: The HALT mode will stop CKI from oscillating in the RC and the Crystal configurations. Measurement of IDD HALT is done with device neither sourcing nor sinking current; with L, C, G0, and G2–G5 programmed as low outputs and not driving a load; all outputs programmed low and not driving a load; all inputs tied to VCC; clock monitor and comparator disabled. Parameter refers to HALT mode entered via setting bit 7 of the G Port data register. Part will pull up CKI during HALT in crystal clock mode. Note 14: Pins G6 and RESET are designed with a high voltage input network. These pins allow input voltages > VCC and the pins will have sink current to VCC when biased at voltages > VCC(the pins do not have source current when biased at a voltage below VCC). The effective resistance to VCC is 750Ω (typical). These two pins will not latch up. The voltage at the pins must be limited to < 14V. WARNING: Voltages in excess of 14V will cause damage to the pins. This warning excludes ESD transients. Note 15: The output propagation delay is referenced to the end of the instruction cycle where the output change occurs. Note 16: Parameter characterized but not tested. www.national.com 8 Total Current into VCC Pin (Source) Total Current out of GND Pin (Sink) Storage Temperature Range If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications. Supply Voltage (VCC) Voltage at Any Pin 100 mA 110 mA −65˚C to +140˚C Note 17: Absolute maximum ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications are not ensured when operating the device at absolute maximum ratings. 7V −0.3V to VCC + 0.3V DC Electrical Characteristics 68xEK: −55˚C ≤ TA ≤ +125˚C unless otherwise specified Parameter Conditions Operating Voltage Power Supply Ripple (Note 19) Supply Current (Note 22) CKI = 10 MHz Min Typ 4.5 Peak-to-Peak VCC = 5.5V, tc = 1 µs HALT Current (Note 21) VCC = 5.5V, CKI = 0 MHz IDLE Current (Note 22) CKI = 10 MHz VCC = 5.5V, tc = 1 µs < 10 Max Units 5.5 V 0.1 VCC V 12.5 mA 30 µA 1.7 mA Input Levels (VIH, VIL) RESET Logic High 0.8 VCC V Logic Low 0.2 VCC V CKI, All Other Inputs Logic High 0.7 VCC V Logic Low Hi-Z Input Leakage Input Pullup Current VCC = 5.5V VCC = 5.5V, VIN = 0V −5 −35 G and L Port Input Hysteresis (Note 24) 0.2 VCC V +5 µA −400 µA 0.35 VCC V Output Current Levels D Outputs Source Sink VCC = 4.5V, VOH = 3.3V VCC = 4.5V, VOL = 1.0V −0.4 mA 9.0 mA VCC = 4.5V, VOH = 2.7V VCC = 4.5V, VOH = 3.3V VCC = 4.5V, VOL = 0.4V −9.0 VCC = 5.5V −5.0 All Others Source (Weak Pull-Up Mode) Source (Push-Pull Mode) Sink (Push-Pull Mode) TRI-STATE Leakage −110 −0.4 µA mA 1.6 mA +5 µA D Outputs (Sink) 12 mA All others 2.5 mA ± 100 mA Allowable Sink/Source Current per Pin Maximum Input Current Room Temp without Latchup (Note 22) RAM Retention Voltage, Vr 500 ns Rise and 2 1.5 V and Fall Time (min) Input Capacitance Load Capacitance on D2 9 7 pF 1000 pF www.national.com COP888EK Absolute Maximum Ratings (Note 17) COP888EK AC Electrical Characteristics 68xEK: −55˚C ≤ TA ≤ +125˚C unless otherwise specified Parameter Conditions Min Typ Max Units Instruction Cycle Time (tc) Crystal, Resonator 4.5V ≤ VCC ≤ 5.5V 1.0 DC µs R/C Oscillator 4.5V ≤ VCC < 5.5V 3.0 DC µs tSETUP 4.5V ≤ VCC ≤ 5.5V 200 ns tHOLD 4.5V ≤ VCC ≤ 5.5V RL = 2.2k, CL = 100 pF 60 ns Inputs Output Propagation Delay (Note 23) tPD1, tPD0 4.5V ≤ VCC ≤ 5.5V SO, SK 4.5V ≤ VCC ≤ 5.5V All Others MICROWIRE Setup Time (tUWS) (Note 23) VCC ≥ 4.5V 20 MICROWIRE Hold Time (tUWH) (Note 23) VCC ≥ 4.5V 56 MICROWIRE Output Propagation Delay (tUPD) VCC ≥ 4.5V 0.7 µs 1.0 µs ns ns 220 ns Input Pulse Width (Note 24) Interrupt Input High Time 1.0 tc Interrupt Input Low Time 1.0 tc Timer 1, 2, 3 Input High Time 1.0 tc Timer 1, 2, 3 Input Low Time 1.0 tc 1.0 µs Reset Pulse Width Note 18: tc = Instruction Cycle Time Note 19: Maximum rate of voltage change must be < 0.5 V/ms. Note 20: Supply and IDLE currents are measured with CKI driven with a square wave Oscillator, CKO driven 180˚ out of phase with CKI, inputs connected to VCC and outputs driven low but not connected to a load. Note 21: The HALT mode will stop CKI from oscillating in the RC and the Crystal configurations. Measurement of IDD HALT is done with device neither sourcing nor sinking current; with L, C, G0, and G2–G5 programmed as low outputs and not driving a load; all outputs programmed low and not driving a load; all inputs tied to VCC; clock monitor and comparator disabled. Parameter refers to HALT mode entered via setting bit 7 of the G Port data register. Part will pull up CKI during HALT in crystal clock mode. Note 22: Pins G6 and RESET are designed with a high voltage input network. These pins allow input voltages > VCC and the pins will have sink current to VCC when biased at voltages > VCC(the pins do not have source current when biased at a voltage below VCC). The effective resistance to VCC is 750Ω (typical). These two pins will not latch up. The voltage at the pins must be limited to < 14V. WARNING: Voltages in excess of 14V will cause damage to the pins. This warning excludes ESD transients. Note 23: The output propagation delay is referenced to the end of the instruction cycle where the output change occurs. Note 24: Parameter characterized but not tested. Analog Function Block AC and DC Characteristics VCC = 5.0V, −40˚C ≤ TA ≤ +85˚C Parameter Input Offset Voltage Conditions Input Common Mode Voltage Range (Note 26) VCC/2 Reference DC Supply Current for Comparator (when enabled) DC Supply Current for VCC/2 Reference (when enabled) DC Supply Current for Constant Current Source (when enabled) 4.0V < VCC < 6.0V Max Units ± 10 ± 25 mV VCC − 1.5 V 0.5 VCC − 0.04 0.5 VCC VCC = 6.0V 50 VCC = 6.0V VCC = 6.0V 4.0V < VCC < 6.0V Current Source Variation over 4.0V < VCC < 6.0V Temp = Constant Current Source Enable Time www.national.com Typ 0.4 Constant Current Source Common Mode Range Min 0.4V < VIN < VCC − 1.5V 10 20 1.5 10 0.5 VCC + 0.04 V 250 µA 80 µA 200 µA 40 µA ±2 µA 2 µs (Continued) VCC = 5.0V, −40˚C ≤ TA ≤ +85˚C Parameter Comparator Response Time Conditions Min 100 mV Overdrive, Typ Max Units 1 µs 100 pF Load Note 25: While performance characteristics are given at VCC = 5.0V, the analog function block will operate over the entire 2.5V–6.0V VCC range. Accuracy of the VCC/2 reference and the constant current source is not guaranteed beyond the specified limits. Note 26: The device is capable of operating over a common mode voltage range of 0 to VCC − 1.5V, however increased offset voltage will be observed between 0V and 0.4V. DS012094-18 FIGURE 3. MICROWIRE/PLUS Timing Typical Performance Characteristics (−55˚C ≤ TA = +125˚C) DS012094-19 DS012094-20 DS012094-21 DS012094-22 11 www.national.com COP888EK Analog Function Block AC and DC Characteristics COP888EK Typical Performance Characteristics (−55˚C ≤ TA = +125˚C) (Continued) DS012094-23 DS012094-24 DS012094-25 DS012094-26 DS012094-27 www.national.com DS012094-28 12 (−55˚C ≤ TA = +125˚C) (Continued) DS012094-29 DS012094-30 The Port L has the following alternate features: L7 MIWU or T3B L6 MIWU or T3A L5 MIWU or T2B L4 MIWU or T2A L3 MIWU L2 MIWU L1 MIWU L0 MIWU Port G is an 8-bit port with 5 I/O pins (G0, G2–G5), an input pin (G6), and a dedicated output pin (G7). Pins G0 and G2–G6 all have Schmitt Triggers on their inputs. Pin G1 serves as the dedicated WDOUT WATCHDOG output, while pin G7 is either input or output depending on the oscillator mask option selected. With the crystal oscillator option selected, G7 serves as the dedicated output pin for the CKO clock output. With the single-pin R/C oscillator mask option selected, G7 serves as a general purpose input pin but is also used to bring the device out of HALT mode with a low to high transition on G7. There are two registers associated with the G Port, a data register and a configuration register. Therefore, each of the 5 I/O bits (G0, G2–G5) can be individually configured under software control. Since G6 is an input only pin and G7 is the dedicated CKO clock output pin (crystal clock option) or general purpose input (R/C clock option), the associated bits in the data and configuration registers for G6 and G7 are used for special purpose functions as outlined on the next page. Reading the G6 and G7 data bits will return zeros. Pin Descriptions VCC and GND are the power supply pins. All VCC and GND pins must be connected. CKI is the clock input. This can come from an R/C generated oscillator, or a crystal oscillator (in conjunction with CKO). See Oscillator Description section. RESET is the master reset input. See Reset Description section. The device contains three bidirectional 8-bit I/O ports (C, G and L), where each individual bit may be independently configured as an input (Schmitt Trigger inputs on ports L and G), output or TRI-STATE under program control. Three data memory address locations are allocated for each of these I/O ports. Each I/O port has two associated 8-bit memory mapped registers, the CONFIGURATION register and the output DATA register. A memory mapped address is also reserved for the input pins of each I/O port. (See the memory map for the various addresses associated with the I/O ports.) Figure 4 shows the I/O port configurations. The DATA and CONFIGURATION registers allow for each port bit to be individually configured under software control as shown below: CONFIGURATION DATA Register Register 0 0 Port Set-Up Hi-Z Input (TRI-STATE Output) 0 1 Input with Weak Pull-Up 1 0 Push-Pull Zero Output 1 1 Push-Pull One Output COP888EK Typical Performance Characteristics PORT L is an 8-bit I/O port. All L-pins have Schmitt triggers on the inputs. The Port L supports Multi-Input Wake Up on all eight pins. L4 and L5 are used for the timer input functions T2A and T2B. L6 and L7 are used for the timer input functions T3A and T3B. 13 www.national.com COP888EK Pin Descriptions (Continued) DS012094-5 FIGURE 4. I/O Port Configurations I5 I4 I3 COMPIN4+ (Comparator Positive Input 4) COMPIN3+ (Comparator Positive Input 3) COMPOUT/COMPIN2+ (Comparator Output/ Comparator Positive Input 2)) I2 COMPIN0+ (Comparator Positive Input 0) I1 COMPIN− (Comparator Negative Input/Current Source Out) I0 COMPIN1+ (Comparator Positive Input 1) Port D is an 8-bit output port that is preset high when RESET goes low. The user can tie two or more D port outputs (except D2) together in order to get a higher drive. Note that the chip will be placed in the HALT mode by writing a “1” to bit 7 of the Port G Data Register. Similarly the chip will be placed in the IDLE mode by writing a “1” to bit 6 of the Port G Data Register. Writing a “1” to bit 6 of the Port G Configuration Register enables the MICROWIRE/PLUS to operate with the alternate phase of the SK clock. The G7 configuration bit, if set high, enables the clock start up delay after HALT when the R/C clock configuration is used. Config Reg. Data Reg. G7 CLKDLY HALT G6 Alternate SK IDLE Note: Care must be exercised with the D2 pin operation. At RESET, the external loads on this pin must ensure that the output voltages stay above 0.8 VCC to prevent the chip from entering special modes. Also keep the external loading on D2 to < 1000 pF. Port G has the following alternate features: G6 SI (MICROWIRE Serial Data Input) G5 SK (MICROWIRE Serial Clock) G4 SO (MICROWIRE Serial Data Output) G3 T1A (Timer T1 I/O) G2 T1B (Timer T1 Capture Input) G0 INTR (External Interrupt Input) Port G has the following dedicated functions: G7 CKO Oscillator dedicated output or general purpose input G1 WDOUT WATCHDOG and/or Clock Monitor dedicated output Port C is an 8-bit I/O port. The 40-pin device does not have a full complement of Port C pins. The unavailable pins are not terminated. A read operation for these unterminated pins will return unpredicatable values. PORT I is an eight-bit Hi-Z input port. The 28-pin device does not have a full complement of Port I pins. The unavailable pins are not terminated i.e., they are floating. A read operation for these unterminated pins will return unpredictable values. The user must ensure that the software takes this into account by either masking or restricting the accesses to bit operations. The unterminated Port I pins will draw power only when addressed. Port I is an eight-bit Hi-Z input port. Port I0–I7 are used for the analog function block. The Port I has the following alternate features: I7 COMPOUT (Comparator Output) I6 COMPIN5+ (Comparator Positive Input 5) www.national.com Functional Description The architecture of the device is modified Harvard architecture. With the Harvard architecture, the control store program memory (ROM) is separated from the data store memory (RAM). Both ROM and RAM have their own separate addressing space with separate address buses. The architecture, though based on Harvard architecture, permits transfer of data from ROM to RAM. CPU REGISTERS The CPU can do an 8-bit addition, subtraction, logical or shift operation in one instruction (tc) cycle time. There are six CPU registers: A is the 8-bit Accumulator Register PC is the 15-bit Program Counter Register PU is the upper 7 bits of the program counter (PC) PL is the lower 8 bits of the program counter (PC) B is an 8-bit RAM address pointer, which can be optionally post auto incremented or decremented. X is an 8-bit alternate RAM address pointer, which can be optionally post auto incremented or decremented. SP is the 8-bit stack pointer, which points to the subroutine/ interrupt stack (in RAM). The SP is initialized to RAM address 06F with reset. 14 0200 to 027F for data segment 2, etc., up to FF00 to FF7F for data segment 255. The base address range from 0000 to 007F represents data segment 0. (Continued) S is the 8-bit Data Segment Address Register used to extend the lower half of the address range (00 to 7F) into 256 data segments of 128 bytes each. Figure 5 illustrates how the S register data memory extension is used in extending the lower half of the base address range (00 to 7F hex) into 256 data segments of 128 bytes each, with a total addressing range of 32 kbytes from XX00 to XX7F. This organization allows a total of 256 data segments of 128 bytes each with an additional upper base segment of 128 bytes. Furthermore, all addressing modes are available for all data segments. The S register must be changed under program control to move from one data segment (128 bytes) to another. However, the upper base segment (containing the 16 memory registers, I/O registers, control registers, etc.) is always available regardless of the contents of the S register, since the upper base segment (address range 0080 to 00FF) is independent of data segment extension. The instructions that utilize the stack pointer (SP) always reference the stack as part of the base segment (Segment 0), regardless of the contents of the S register. The S register is not changed by these instructions. Consequently, the stack (used with subroutine linkage and interrupts) is always located in the base segment. The stack pointer will be intitialized to point at data memory location 006F as a result of reset. The 128 bytes of RAM contained in the base segment are split between the lower and upper base segments. The first 112 bytes of RAM are resident from address 0000 to 006F in the lower base segment, while the remaining 16 bytes of RAM represent the 16 data memory registers located at addresses 00F0 to 00FF of the upper base segment. No RAM is located at the upper sixteen addresses (0070 to 007F) of the lower base segment. Additional RAM beyond these initial 128 bytes, however, will always be memory mapped in groups of 128 bytes (or less) at the data segment address extensions (XX00 to XX7F) of the lower base segment. The additional 128 bytes of RAM are memory mapped at address locations 0100 to 017F hex. All the CPU registers are memory mapped with the exception of the Accumulator (A) and the Program Counter (PC). PROGRAM MEMORY The program memory consists of 8192 bytes of ROM. These bytes may hold program instructions or constant data (data tables for the LAID instruction, jump vectors for the JID instruction, and interrupt vectors for the VIS instruction). The program memory is addressed by the 15-bit program counter (PC). All interrupts in the devices vector to program memory location 0FF Hex. DATA MEMORY The data memory address space includes the on-chip RAM and data registers, the I/O registers (Configuration, Data and Pin), the control registers, the MICROWIRE/PLUS SIO shift register, and the various registers, and counters associated with the timers (with the exception of the IDLE timer). Data memory is addressed directly by the instruction or indirectly by the B, X, SP pointers and S register. The data memory consists of 256 bytes of RAM. Sixteen bytes of RAM are mapped as “registers” at addresses 0F0 to 0FF Hex. These registers can be loaded immediately, and also decremented and tested with the DRSZ (decrement register and skip if zero) instruction. The memory pointer registers X, SP, B and S are memory mapped into this space at address locations 0FC to 0FF Hex respectively, with the other registers being available for general usage. The instruction set permits any bit in memory to be set, reset or tested. All I/O and registers (except A and PC) are memory mapped; therefore, I/O bits and register bits can be directly and individually set, reset and tested. The accumulator (A) bits can also be directly and individually tested. Note: RAM contents are undefined upon power-up. Data Memory Segment RAM Extension Data memory address 0FF is used as a memory mapped location for the Data Segment Address Register (S). The data store memory is either addressed directly by a single byte address within the instruction, or indirectly relative to the reference of the B, X, or SP pointers (each contains a single-byte address). This single-byte address allows an addressing range of 256 locations from 00 to FF hex. The upper bit of this single-byte address divides the data store memory into two separate sections as outlined previously. With the exception of the RAM register memory from address locations 00F0 to 00FF, all RAM memory is memory mapped with the upper bit of the single-byte address being equal to zero. This allows the upper bit of the single-byte address to determine whether or not the base address range (from 0000 to 00FF) is extended. If this upper bit equals one (representing address range 0080 to 00FF), then address extension does not take place. Alternatively, if this upper bit equals zero, then the data segment extension register S is used to extend the base address range (from 0000 to 007F) from XX00 to XX7F, where XX represents the 8 bits from the S register. Thus the 128-byte data segment extensions are located from addresses 0100 to 017F for data segment 1, DS012094-6 *Reads as all ones. FIGURE 5. RAM Organization 15 www.national.com COP888EK Functional Description COP888EK R/C OSCILLATOR Reset By selecting CKI as a single pin oscillator input, a single pin R/C oscillator circuit can be connected to it. CKO is available as a general purpose input, and/or HALT restart input. The RESET input when pulled low initializes the microcontroller. Initialization will occur whenever the RESET input is pulled low. Upon initialization, the data and configuration registers for ports L, G and C are cleared, resulting in these Ports being initialized to the TRI-STATE mode. Pin G1 of the G Port is an exception (as noted below) since pin G1 is dedicated as the WATCHDOG and/or Clock Monitor error output pin. Port D is set high. The PC, PSW, ICNTRL, CNTRL, T2CNTRL and T3CNTRL control registers are cleared. The Comparator Select Register is cleared. The S register is initialized to zero. The Multi-Input Wakeup registers WKEN and WKEDG are cleared. Wakeup register WKPND is unknown. The stack pointer, SP, is initialized to 6F hex. The device comes out of reset with both the WATCHDOG logic and the Clock Monitor detector armed, with the WATCHDOG service window bits set and the Clock Monitor bit set. The WATCHDOG and Clock Monitor circuits are inhibited during reset. The WATCHDOG service window bits being initialized high default to the maximum WATCHDOG service window of 64k tC clock cycles. The Clock Monitor bit being initialized high will cause a Clock Monitor error following reset if the clock has not reached the minimum specified frequency at the termination of reset. A Clock Monitor error will cause an active low error output on pin G1. This error output will continue until 16 tC–32 tC clock cycles following the clock frequency reaching the minimum specified value, at which time the G1 output will enter the TRI-STATE mode. The external RC network shown in Figure 6 should be used to ensure that the RESET pin is held low until the power supply to the chip stabilizes. Note: Use of the R/C oscillator option will result in higher electromagnetic emissions. Table 2 shows the variation in the oscillator frequencies as functions of the component (R and C) values. DS012094-8 DS012094-9 FIGURE 7. Crystal and R/C Oscillator Diagrams TABLE 1. Crystal Oscillator Configuration, TA = 25˚C R2 C1 C2 CKI Freq (kΩ) (MΩ) (pF) (pF) (MHz) 0 1 30 30–36 10 0 1 30 30–36 4 0 1 200 100–150 > 5 x Power Supply Rise Time FIGURE 6. Recommended Reset Circuit Oscillator Circuits The chip can be driven by a clock input on the CKI input pin which can be between DC and 10 MHz. The CKO output clock is on pin G7 (crystal configuration). The CKI input frequency is divided down by 10 to produce the instruction cycle clock (1/tc). VCC = 5V VCC = 5V VCC = 5V R C CKI Freq Instr. Cycle (kΩ) (pF) (MHz) (µs) 3.3 82 2.2 to 2.7 3.7 to 4.6 5.6 100 1.1 to 1.3 7.4 to 9.0 VCC = 5V VCC = 5V 6.8 100 0.9 to 1.1 8.8 to 10.8 VCC = 5V Conditions Note 27: 3k ≤ R ≤ 200k 50 pF ≤ C ≤ 200 pF Control Registers Note: External clocks with frequencies above about 4 MHz require the user to drive the CKO (G7) pin with a signal 180 degrees out of phase with CKI. CNTRL Register (Address X'00EE) T1C3 Figure 7 shows the Crystal and R/C oscillator diagrams. Bit 7 CRYSTAL OSCILLATOR CKI and CKO can be connected to make a closed loop crystal (or resonator) controlled oscillator. T1C2 T1C1 T1C0 MSEL IEDG SL1 SL0 Bit 0 The Timer1 (T1) and MICROWIRE/PLUS control register contains the following bits: T1C3 Timer T1 mode control bit T1C2 Timer T1 mode control bit T1C1 Timer T1 mode control bit T1C0 Timer T1 Start/Stop control in timer modes 1 and 2, T1 Underflow Interrupt Pending Flag in timer mode 3 Table 1 shows the component values required for various standard crystal values. www.national.com 0.455 Conditions TABLE 2. RC Oscillator Configuration, TA = 25˚C DS012094-7 RC R1 16 (Continued) MSEL Selects G5 and G4 as MICROWIRE/PLUS signals SK and SO respectively IEDG External interrupt edge polarity select SL1 & SL0 T2PNDA Timer T2 Interrupt Pending Flag (Autoreload RA in mode 1, T2 Underflow in mode 2, T2A capture edge in mode 3) T2ENA Timer T2 Interrupt Enable for Timer Underflow or T2A Input capture edge Timer T2 Interrupt Pending Flag for T2B capture edge Timer T2 Interrupt Enable for Timer Underflow or T2B Input capture edge (0 = Rising edge, 1 = Falling edge) T2PNDB Select the MICROWIRE/PLUS clock divide by (00 = 2, 01 = 4, 1x = 8) T2ENB PSW Register (Address X'00EF) HC C T1PNDA T1ENA EXPND BUSY EXEN Bit 7 T3CNTRL Register (Address X'00B6) GIE T3C3 Bit 0 The PSW register contains the following select bits: HC Half Carry Flag C Carry Flag T1PNDA Timer T1 Interrupt Pending Flag (Autoreload RA in mode 1, T1 Underflow in Mode 2, T1A capture edge in mode 3) T1ENA Timer T1 Interrupt Enable for Timer Underflow or T1A Input capture edge EXPND External interrupt pending BUSY MICROWIRE/PLUS busy shifting flag EXEN Enable external interrupt GIE Global interrupt enable (enables interrupts) The Half-Carry flag is also affected by all the instructions that affect the Carry flag. The SC (Set Carry) and R/C (Reset Carry) instructions will respectively set or clear both the carry flags. In addition to the SC and R/C instructions, ADC, SUBC, RRC and RLC instructions affect the Carry and Half Carry flags. LPEN T0PND T0EN µWPND µWEN T1PNDB Bit 7 Bit 0 T2C2 T2C1 T2C0 T2PNDA T2ENA T2PNDB T3PNDA T3ENA T3PNDB T3ENB Bit 0 The device contains a very versatile set of timers (T0, T1, T2, T3). All timers and associated autoreload/capture registers power up containing random data. T1ENB TIMER T0 (IDLE TIMER) The device supports applications that require maintaining real time and low power with the IDLE mode. This IDLE mode support is furnished by the IDLE timer T0, which is a 16-bit timer. The Timer T0 runs continuously at the fixed rate of the instruction cycle clock, tc. The user cannot read or write to the IDLE Timer T0, which is a count down timer. The Timer T0 supports the following functions: j Exit out of the Idle Mode (See Idle Mode description) j WATCHDOG logic (See WATCHDOG description) j Start up delay out of the HALT mode The IDLE Timer T0 can generate an interrupt when the thirteenth bit toggles. This toggle is latched into the T0PND pending flag, and will occur every 4 ms at the maximum clock frequency (tc = 1 µs). A control flag T0EN allows the interrupt from the thirteenth bit of Timer T0 to be enabled or disabled. Setting T0EN will enable the interrupt, while resetting it will disable the interrupt. T2CNTRL Register (Address X'00C6) Bit 7 T3C0 Timers The ICNTRL register contains the following bits: Rsvd This bit is reserved and must be zero LPEN L Port Interrupt Enable (Multi-Input Wakeup/ Interrupt) T0PND Timer T0 Interrupt pending T0EN Timer T0 Interrupt Enable (Bit 12 toggle) µWPND MICROWIRE/PLUS interrupt pending µWEN Enable MICROWIRE/PLUS interrupt T1PNDB Timer T1 Interrupt Pending Flag for T1B capture edge T1ENB Timer T1 Interrupt Enable for T1B Input capture edge T2C3 T3C1 The T3CNTRL control register contains the following bits: T3C3 Timer T3 mode control bit T3C2 Timer T3 mode control bit T3C1 Timer T3 mode control bit T3C0 Timer T3 Start/Stop control in timer modes 1 and 2, T3 Underflow Interrupt Pending Flag in timer mode 3 T3PNDA Timer T3 Interrupt Pending Flag (Autoreload RA in mode 1, T3 Underflow in mode 2, T3A capture edge in mode 3) T3ENA Timer T3 Interrupt Enable for Timer Underflow or T3A Input capture edge T3PNDB Timer T3 Interrupt Pending Flag for T3B capture edge T3ENB Timer T3 Interrupt Enable for Timer Underflow or T3B Input capture edge ICNTRL Register (Address X'00E8) Rsvd T3C2 Bit 7 T2ENB Bit 0 The T2CNTRL control register contains the following bits: T2C3 Timer T2 mode control bit T2C2 Timer T2 mode control bit T2C1 Timer T2 mode control bit T2C0 Timer T2 Start/Stop control in timer modes 1 and 2, T2 Underflow Interrupt Pending Flag in timer mode 3 TIMER T1, TIMER T2 AND TIMER T3 The device has a set of three powerful timer/counter blocks, T1, T2 and T3. The associated features and functioning of a timer block are described by referring to the timer block Tx. Since the three timer blocks, T1, T2 and T3 are identical, all comments are equally applicable to any of the three timer blocks. 17 www.national.com COP888EK Control Registers COP888EK Timers (Continued) Each timer block consists of a 16-bit timer, Tx, and two supporting 16-bit autoreload/capture registers, RxA and RxB. Each timer block has two pins associated with it, TxA and TxB. The pin TxA supports I/O required by the timer block, while the pin TxB is an input to the timer block. The powerful and flexible timer block allows the device to easily perform all timer functions with minimal software overhead. The timer block has three operating modes: Processor Independent PWM mode, External Event Counter mode, and Input Capture mode. The control bits TxC3, TxC2, and TxC1 allow selection of the different modes of operation. DS012094-10 Mode 1. Processor Independent PWM Mode As the name suggests, this mode allows the device to generate a PWM signal with very minimal user intervention. The user only has to define the parameters of the PWM signal (ON time and OFF time). Once begun, the timer block will continuously generate the PWM signal completely independent of the microcontroller. The user software services the timer block only when the PWM parameters require updating. In this mode the timer Tx counts down at a fixed rate of tc. Upon every underflow the timer is alternately reloaded with the contents of supporting registers, RxA and RxB. The very first underflow of the timer causes the timer to reload from the register RxA. Subsequent underflows cause the timer to be reloaded from the registers alternately beginning with the register RxB. The Tx Timer control bits, TxC3, TxC2 and TxC1 set up the timer for PWM mode operation. FIGURE 8. Timer in PWM Mode Mode 2. External Event Counter Mode This mode is quite similar to the processor independent PWM mode described above. The main difference is that the timer, Tx, is clocked by the input signal from the TxA pin. The Tx timer control bits, TxC3, TxC2 and TxC1 allow the timer to be clocked either on a positive or negative edge from the TxA pin. Underflows from the timer are latched into the TxPNDA pending flag. Setting the TxENA control flag will cause an interrupt when the timer underflows. In this mode the input pin TxB can be used as an independent positive edge sensitive interrupt input if the TxENB control flag is set. The occurrence of a positive edge on the TxB input pin is latched into the TxPNDB flag. Figure 9 shows a block diagram of the timer in External Event Counter mode. Figure 8 shows a block diagram of the timer in PWM mode. The underflows can be programmed to toggle the TxA output pin. The underflows can also be programmed to generate interrupts. Underflows from the timer are alternately latched into two pending flags, TxPNDA and TxPNDB. The user must reset these pending flags under software control. Two control enable flags, TxENA and TxENB, allow the interrupts from the timer underflow to be enabled or disabled. Setting the timer enable flag TxENA will cause an interrupt when a timer underflow causes the RxA register to be reloaded into the timer. Setting the timer enable flag TxENB will cause an interrupt when a timer underflow causes the RxB register to be reloaded into the timer. Resetting the timer enable flags will disable the associated interrupts. Either or both of the timer underflow interrupts may be enabled. This gives the user the flexibility of interrupting once per PWM period on either the rising or falling edge of the PWM output. Alternatively, the user may choose to interrupt on both edges of the PWM output. www.national.com Note: The PWM output is not available in this mode since the TxA pin is being used as the counter input clock. DS012094-11 FIGURE 9. Timer in External Event Counter Mode 18 COP888EK Timers (Continued) Mode 3. Input Capture Mode The device can precisely measure external frequencies or time external events by placing the timer block, Tx, in the input capture mode. In this mode, the timer Tx is constantly running at the fixed tc rate. The two registers, RxA and RxB, act as capture registers. Each register acts in conjunction with a pin. The register RxA acts in conjunction with the TxA pin and the register RxB acts in conjunction with the TxB pin. The timer value gets copied over into the register when a trigger event occurs on its corresponding pin. Control bits, TxC3, TxC2 and TxC1, allow the trigger events to be specified either as a positive or a negative edge. The trigger condition for each input pin can be specified independently. The trigger conditions can also be programmed to generate interrupts. The occurrence of the specified trigger condition on the TxA and TxB pins will be respectively latched into the pending flags, TxPNDA and TxPNDB. The control flag TxENA allows the interrupt on TxA to be either enabled or disabled. Setting the TxENA flag enables interrupts to be generated when the selected trigger condition occurs on the TxA pin. Similarly, the flag TxENB controls the interrupts from the TxB pin. T2 has additional flexibility because T2B can be internally connected to the comparator output of the Analog Function Block. This allows the user to capture the time of a comparator event without using external pins. Underflows from the timer can also be programmed to generate interrupts. Underflows are latched into the timer TxC0 pending flag (the TxC0 control bit serves as the timer underflow interrupt pending flag in the Input Capture mode). Consequently, the TxC0 control bit should be reset when entering the Input Capture mode. The timer underflow interrupt is enabled with the TxENA control flag. When a TxA interrupt occurs in the Input Capture mode, the user must check both the TxPNDA and TxC0 pending flags in order to determine whether a TxA input capture or a timer underflow (or both) caused the interrupt. DS012094-12 FIGURE 10. Timer in Input Capture Mode TIMER CONTROL FLAGS The control bits and their functions are summarized below. TxC3 Timer mode control TxC2 Timer mode control TxC1 Timer mode control TxC0 Timer Start/Stop control in Modes 1 and 2 (Processor Independent PWM and External Event Counter), where 1 = Start, 0 = Stop Timer Underflow Interrupt Pending Flag in Mode 3 (Input Capture) TxPNDA Timer Interrupt Pending Flag TxENA Timer Interrupt Enable Flag 1 = Timer Interrupt Enabled 0 = Timer Interrupt Disabled TxPNDB Timer Interrupt Pending Flag TxENB Timer Interrupt Enable Flag 1 = Timer Interrupt Enabled 0 = Timer Interrupt Disabled Figure 10 shows a block diagram of the timer in Input Capture mode. 19 www.national.com COP888EK Timers (Continued) The timer mode control bits (TxC3, TxC2 and TxC1) are detailed below: 1 0 1 PWM: TxA Toggle Autoreload RA Autoreload RB 1 0 0 PWM: No TxA Toggle Autoreload RA Autoreload RB 0 0 0 External Event Counter Timer Underflow Pos. TxB Edge Pos. TxA Edge 0 0 1 External Event Counter Timer Underflow Pos. TxB Edge Pos. TxA Edge 0 1 0 Captures: Pos. TxA Edge Pos. TxB Edge tC TxA Pos. Edge or Timer TxB Pos. Edge Underflow Captures: Pos. TxA Neg. TxB tC TxA Pos. Edge Edge or Timer Edge TxB Neg. Edge Underflow Captures: Neg. TxA Neg. TxB TxA Neg. Edge Edge or Timer Edge TxB Neg. Edge Underflow Captures: Neg. TxA Neg. TxB TxA Neg. Edge Edge or Timer Edge TxB Neg. Edge Underflow 3 0 1 1 1 1 0 1 1 Description Timer Counts On 1 1 TxC1 Interrupt B Source TxC3 2 TxC2 Interrupt A Source Mode tC tC tC resonators have a delayed start up time to reach full amplitude and frequency stability. The IDLE timer is used to generate a fixed delay to ensure that the oscillator has indeed stabilized before allowing instruction execution. In this case, upon detecting a valid Wakeup signal, only the oscillator circuitry is enabled. The IDLE timer is loaded with a value of 256 and is clocked with the tc instruction cycle clock. The tc clock is derived by dividing the oscillator clock down by a factor of 10. The Schmitt trigger following the CKI inverter on the chip ensures that the IDLE timer is clocked only when the oscillator has a sufficiently large amplitude to meet the Schmitt trigger specifications. This Schmitt trigger is not part of the oscillator closed loop. The startup timeout from the IDLE timer enables the clock signals to be routed to the rest of the chip. If an RC clock option is being used, the fixed delay is introduced optionally. A control bit, CLKDLY, mapped as configuration bit G7, controls whether the delay is to be introduced or not. The delay is included if CLKDLY is set, and excluded if CLKDLY is reset. The CLKDLY bit is cleared on reset. The device has two mask options associated with the HALT mode. The first mask option enables the HALT mode feature, while the second mask option disables the HALT mode. With the HALT mode enable mask option, the device will enter and exit the HALT mode as described above. With the HALT disable mask option, the device cannot be placed in the HALT mode (writing a “1” to the HALT flag will have no effect, the HALT flag will remain “0”). The WATCHDOG detector circuit is inhibited during the HALT mode. However, the clock monitor circuit if enabled remains active during HALT mode in order to ensure a clock monitor error if the device inadvertently enters the HALT mode as a result of a runaway program or power glitch. Power Save Modes The device offers the user two power save modes of operation: HALT and IDLE. In the HALT mode, all microcontroller activities are stopped. In the IDLE mode, the on-board oscillator circuitry the WATCHDOG logic, the Clock Monitor and timer T0 are active but all other microcontroller activities are stopped. In either mode, all on-board RAM, registers, I/O states, and timers (with the exception of T0) are unaltered. HALT MODE The device can be placed in the HALT mode by writing a “1” to the HALT flag (G7 data bit). All microcontroller activities, including the clock and timers, are stopped. The WATCHDOG logic is disabled during the HALT mode. However, the clock monitor circuitry if enabled remains active and will cause the WATCHDOG output pin (WDOUT) to go low. If the HALT mode is used and the user does not want to activate the WDOUT pin, the Clock Monitor should be disabled after the device comes out of reset (resetting the Clock Monitor control bit with the first write to the WDSVR register). In the HALT mode, the power requirements of the device are minimal and the applied voltage (VCC) may be decreased to Vr (Vr = 2.0V) without altering the state of the machine. The device supports three different ways of exiting the HALT mode. The first method of exiting the HALT mode is with the Multi-Input Wakeup feature on the L port. The second method is with a low to high transition on the CKO (G7) pin. This method precludes the use of the crystal clock configuration (since CKO becomes a dedicated output), and so may be used with an RC clock configuration. The third method of exiting the HALT mode is by pulling the RESET pin low. Since a crystal or ceramic resonator may be selected as the oscillator, the Wakeup signal is not allowed to start the chip running immediately since crystal oscillators and ceramic www.national.com tC 20 IDLE MODE device will first execute the Timer T0 interrupt service routine and then return to the instruction following the “Enter Idle Mode” instruction. The device is placed in the IDLE mode by writing a “1” to the IDLE flag (G6 data bit). In this mode, all activities, except the associated on-board oscillator circuitry, the WATCHDOG logic, the clock monitor and the IDLE Timer T0, are stopped. Alternatively, the user can enter the IDLE mode with the IDLE Timer T0 interrupt disabled. In this case, the device will resume normal operation with the instruction immediately following the “Enter IDLE Mode” instruction. As with the HALT mode, the device can be returned to normal operation with a reset, or with a Multi-Input Wakeup from the L Port. Alternately, the microcontroller resumes normal operation from the IDLE mode when the thirteenth bit (representing 4.096 ms at internal clock frequency of 1 MHz, tc = 1 µs) of the IDLE Timer toggles. This toggle condition of the thirteenth bit of the IDLE Timer T0 is latched into the T0PND pending flag. The user has the option of being interrupted with a transition on the thirteenth bit of the IDLE Timer T0. The interrupt can be enabled or disabled via the T0EN control bit. Setting the T0EN flag enables the interrupt and vice versa. The user can enter the IDLE mode with the Timer T0 interrupt enabled. In this case, when the T0PND bit gets set, the Note: It is necessary to program two NOP instructions following both the set HALT mode and set IDLE mode instructions. These NOP instructions are necessary to allow clock resynchronization following the HALT or IDLE modes. (Continued) Multi-Input Wakeup The Multi-Input Wakeup feature is ued to return (wakeup) the device from either the HALT or IDLE modes. Alternately Multi-Input Wakeup/Interrupt feature may also be used to generate up to 8 edge selectable external interrupts. Figure 11 shows the Multi-Input Wakeup logic. DS012094-13 FIGURE 11. Multi-Input Wake Up Logic an edge select entails several steps in order to avoid a pseudo Wakeup condition as a result of the edge change. First, the associated WKEN bit should be reset, followed by the edge select change in WKEDG. Next, the associated WKPND bit should be cleared, followed by the associated WKEN bit being re-enabled. An example may serve to clarify this procedure. Suppose we wish to change the edge select from positive (low going high) to negative (high going low) for L Port bit 5, where bit 5 has previously been enabled for an input interrupt. The program would be as follows: RBIT 5, WKEN ; Disable MIWU SBIT 5, WKEDG ; Change edge polarity RBIT 5, WKPND ; Reset pending flag SBIT 5, WKEN ; Enable MIWU The Multi-Input Wakeup feature utilizes the L Port. The user selects which particular L port bit (or combination of L Port bits) will cause the device to exit the HALT or IDLE modes. The selection is done through the Reg: WKEN. The Reg: WKEN is an 8-bit read/write register, which contains a control bit for every L port bit. Setting a particular WKEN bit enables a Wakeup from the associated L port pin. The user can select whether the trigger condition on the selected L Port pin is going to be either a positive edge (low to high transition) or a negative edge (high to low transition). This selection is made via the Reg: WKEDG, which is an 8-bit control register with a bit assigned to each L Port pin. Setting the control bit will select the trigger condition to be a negative edge on that particular L Port pin. Resetting the bit selects the trigger condition to be a positive edge. Changing 21 www.national.com COP888EK Power Save Modes COP888EK Multi-Input Wakeup PORT L INTERRUPTS Port L provides the user with an additional eight fully selectable, edge sensitive interrupts which are all vectored into the same service subroutine. The interrupt from Port L shares logic with the wake up circuitry. The register WKEN allows interrupts from Port L to be individually enabled or disabled. The register WKEDG specifies the trigger condition to be either a positive or a negative edge. Finally, the register WKPND latches in the pending trigger conditions. The GIE (Global Interrupt Enable) bit enables the interrupt function. A control flag, LPEN, functions as a global interrupt enable for Port L interrupts. Setting the LPEN flag will enable interrupts and vice versa. A separate global pending flag is not needed since the register WKPND is adequate. Since Port L is also used for waking the device out of the HALT or IDLE modes, the user can elect to exit the HALT or IDLE modes either with or without the interrupt enabled. If he elects to disable the interrupt, then the device will restart execution from the instruction immediately following the instruction that placed the microcontroller in the HALT or IDLE modes. In the other case, the device will first execute the interrupt service routine and then revert to normal operation. (See HALT MODE for clock option wakeup information.) (Continued) If the L port bits have been used as outputs and then changed to inputs with Multi-Input Wakeup/Interrupt, a safety procedure should also be followed to avoid inherited pseudo wakeup conditions. After the selected L port bits have been changed from output to input but before the associated WKEN bits are enabled, the associated edge select bits in WKEDG should be set or reset for the desired edge selects, followed by the associated WKPND bits being cleared. This same procedure should be used following reset, since the L port inputs are left floating as a result of reset. The occurrence of the selected trigger condition for Multi-Input Wakeup is latched into a pending register called WKPND. The respective bits of the WKPND register will be set on the occurrence of the selected trigger edge on the corresponding Port L pin. The user has the responsibility of clearing these pending flags. Since WKPND is a pending register for the occurrence of selected wakeup conditions, the device will not enter the HALT mode if any Wakeup bit is both enabled and pending. Consequently, the user has the responsibility of clearing the pending flags before attempting to enter the HALT mode. WKEN, WKPND and WKEDG are all read/write registers, and are cleared at reset. Analog Function Block DS012094-14 FIGURE 12. COP888EK Analog Function Block www.national.com 22 source. This current source provides a nominal 20 µA constant current at the I1 pin. This current can be used to ensure a linear charging rate on an external capacitor. This bit has no affect and the current source is disabled if the comparator is not enabled (CMPEN = 0). Enable the comparator (“1” = enable). (Continued) This device contains an analog function block with the intent to provide a function which allows for single slope, low cost, A/D conversion of up to 6 channels. See Application Note 983, Simple, Cost Effective A/D Conversion using COP888EK, for further information on this application. CMPEN CMPSL REGISTER (ADDRESS X’00B7) CMPNEG Will drive I1 to a low level. This bit can be used to discharge an external capacitor. This bit is disabled if the comparator is not enabled (CMPEN = 0). The Comparator Select Register is cleared on RESET (the comparator is disabled). To save power the program should also disable the comparator before the µC enters the HALT/ IDLE modes. Disabling the comparator will turn off the constant current source and the VCC/2 reference, disconnect the comparator output from the T2B input and pin I3 or I7 and remove the low on I1 caused by CMPNEG. It is often useful for the user’s program to read the result of a comparator operation. Since I1 is always selected to be COMPIN− when the comparator is enabled (CMPEN = 1), the comparator output can be read internally by reading bit 1 (CMPRD) of register PORTI (RAM address 0 x D7). The following table lists the comparator inputs and outputs vs. the value of the CMPISEL0/1/2 bits. The output will only be driven if the CMPOE bit is set to 1. CMPT2B CMPISEL2 CMPISEL1 CMPISEL0 CMPOE CSEN CMPEN CMPNEG Bit 7 Bit 0 The CMPSL register contains the following bits: CMPT2B Selects the timer T2B input to be driven directly by the comparator output. If the comparator is disabled (CMPEN = 0), this function is disabled, i.e., the T2B input is connected to Port L5. CMPISEL0/1/2 Will select one of seven possible sources (I0/I2/I3/I4/I5/I6/internal reference) as a positive input to the comparator (see Table 3 for more information.) Power savings can be realized by deselecting the internal reference when it is not in actual use. CMPOE Enables the comparator output to either pin I3 or pin I7 (“1” = enable) depending on the value of CMPISEL0/1/2. CSEN Enables the internal constant current TABLE 3. Comparator Input Selection Control Bit Comparator Input Source Neg. Input Comparator CMPISEL2 CMPISEL1 CMPISEL0 0 0 0 I1 I2 I3 0 0 1 I1 I2 I7 0 1 0 I1 I3 I7 0 1 1 I1 I0 I7 1 0 0 I1 I4 I7 1 0 1 I1 I5 I7 1 1 0 I1 I6 I7 1 1 1 I1 VCC/2 Ref. I7 RESET The state of the Comparator Block immediately after RESET is as follows: 1. The CMPSL Register is set to all zeros 2. The Comparator is disabled 3. The Constant Current Source is disabled 4. CMPNEG is turned off 5. The Port I inputs are electrically isolated from the comparator 6. The T2B input is as normally selected by the T2CNTRL Register 7. CMPISEL0–CMPISEL2 are set to zero 8. All Port I inputs are selected to the default digital input mode The comparator outputs have the same specification as Ports L and G except that the rise and fall times are symmetrical. Pos. Input Output Interrupts Each device supports eleven vectored interrupts. Interrupt sources include Timer 0, Timer 1, Timer 2, Timer 3, Port L Wakeup, Software Trap, MICROWIRE/PLUS, and External Input. All interrupts force a branch to location 00FF Hex in program memory. The VIS instruction may be used to vector to the appropriate service routine from location 00FF Hex. The Software trap has the highest priority while the default VIS has the lowest priority. Each of the 11 maskable inputs has a fixed arbitration ranking and vector. Figure 13 shows the Interrupt Block Diagram. 23 www.national.com COP888EK Analog Function Block COP888EK Interrupts (Continued) DS012094-15 FIGURE 13. Interrupt Block Diagram edged until the start of the next normally executed instruction is to be skipped, the skip is performed before the pending interrupt is acknowledged. At the start of interrupt acknowledgment, the following actions occur: 1. The GIE bit is automatically reset to zero, preventing any subsequent maskable interrupt from interrupting the current service routine. This feature prevents one maskable interrupt from interrupting another one being serviced. 2. The address of the instruction about to be executed is pushed onto the stack. 3. The program counter (PC) is loaded with 00FF Hex, causing a jump to that program memory location. The device requires seven instruction cycles to perform the actions listed above. If the user wishes to allow nested interrupts, the interrupts service routine may set the GIE bit to 1 by writing to the PSW register, and thus allow other maskable interrupts to interrupt the current service routine. If nested interrupts are allowed, caution must be exercised. The user must write the program in such a way as to prevent stack overflow, loss of saved context information, and other unwanted conditions. The interrupt service routine stored at location 00FF Hex should use the VIS instruction to determine the cause of the interrupt, and jump to the interrupt handling routine corresponding to the highest priority enabled and active interrupt. Alternately, the user may choose to poll all interrupt pending and enable bits to determine the source(s) of the interrupt. If more than one interrupt is active, the user’s program must decide which interrupt to service. Within a specific interrupt service routine, the associated pending bit should be cleared. This is typically done as early as possible in the service routine in order to avoid missing the next occurrence of the same type of interrupt event. Thus, if the same event occurs a second time, even while the first occurrence is still being serviced, the second occurrence will be serviced immediately upon return from the current interrupt routine. MASKABLE INTERRUPTS All interrupts other than the Software Trap are maskable. Each maskable interrupt has an associated enable bit and pending flag bit. The pending bit is set to 1 when the interrupt condition occurs. The state of the interrupt enable bit, combined with the GIE bit determines whether an active pending flag actually triggers an interrupt. All of the maskable interrupt pending and enable bits are contained in mapped control registers, and thus can be controlled by the software. A maskable interrupt condition triggers an interrupt under the following conditions: 1. The enable bit associated with that interrupt is set. 2. The GIE bit is set. 3. The device is not processing a non-maskable interrupt. (If a non-maskable interrupt is being serviced, a maskable interrupt must wait until that service routine is completed.) An interrupt is triggered only when all of these conditions are met at the beginning of an instruction. If different maskable interrupts meet these conditions simultaneously, the highest priority interrupt will be serviced first, and the other pending interrupts must wait. Upon Reset, all pending bits, individual enable bits, and the GIE bit are reset to zero. Thus, a maskable interrupt condition cannot trigger an interrupt until the program enables it by setting both the GIE bit and the individual enable bit. When enabling an interrupt, the user should consider whether or not a previously activated (set) pending bit should be acknowledged. If, at the time an interrupt is enabled, any previous occurrences of the interrupt should be ignored, the associated pending bit must be reset to zero prior to enabling the interrupt. Otherwise, the interrupt may be simply enabled; if the pending bit is already set, it will immediately trigger an interrupt. A maskable interrupt is active if its associated enable and pending bits are set. An interrupt is an asychronous event which may occur before, during, or after an instruction cycle. Any interrupt which occurs during the execution of an instruction is not acknowl- www.national.com 24 The vector table should be filled by the user with the memory locations of the specific interrupt service routines. For example, if the Software Trap routine is located at 0310 Hex, then the vector location 0yFE and -0yFF should contain the data 03 and 10 Hex, respectively. When a Software Trap interrupt occurs and the VIS instruction is executed, the program jumps to the address specified in the vector table. (Continued) An interrupt service routine typically ends with an RETI instruction. This instruction sets the GIE bit back to 1, pops the address stored on the stack, and restores that address to the program counter. Program execution then proceeds with the next instruction that would have been executed had there been no interrupt. If there are any valid interrupts pending, the highest-priority interrupt is serviced immediately upon return from the previous interrupt. The interrupt sources in the vector table are listed in order of rank, from highest to lowest priority. If two or more enabled and pending interrupts are detected at the same time, the one with the highest priority is serviced first. Upon return from the interrupt service routine, the next highest-level pending interrupt is serviced. If the VIS instruction is executed, but no interrupts are enabled and pending, the lowest-priority interrupt vector is used, and a jump is made to the corresponding address in the vector table. This is an unusual occurrence, and may be the result of an error. It can legitimately result from a change in the enable bits or pending flags prior to the execution of the VIS instruction, such as executing a single cycle instruction which clears an enable flag at the same time that the pending flag is set. It can also result, however, from inadvertent execution of the VIS command outside of the context of an interrupt. The default VIS interrupt vector can be useful for applications in which time critical interrupts can occur during the servicing of another interrupt. Rather than restoring the program context (A, B, X, etc.) and executing the RETI instruction, an interrupt service routine can be terminated by returning to the VIS instruction. In this case, interrupts will be serviced in turn until no further interrupts are pending and the default VIS routine is started. After testing the GIE bit to ensure that execution is not erroneous, the routine should restore the program context and execute the RETI to return to the interrupted program. This technique can save up to fifty instruction cycles (tc), or more, (50µs at 10 MHz oscillator) of latency for pending interrupts with a penalty of fewer than ten instruction cycles if no further interrupts are pending. To ensure reliable operation, the user should always use the VIS instruction to determine the source of an interrupt. Although it is possible to poll the pending bits to detect the source of an interrupt, this practice is not recommended. The use of polling allows the standard arbitration ranking to be altered, but the reliability of the interrupt system is compromised. The polling routine must individually test the enable and pending bits of each maskable interrupt. If a Software Trap interrupt should occur, it will be serviced last, even though it should have the highest priority. Under certain conditions, a Software Trap could be triggered but not serviced, resulting in an inadvertent “locking out” of all maskable interrupts by the Software Trap pending flag. Problems such as this can be avoided by using VIS instruction. VIS INSTRUCTION The general interrupt service routine, which starts at address 00FF Hex, must be capable of handling all types of interrupts. The VIS instruction, together with an interrupt vector table, directs the device to the specific interrupt handling routine based on the cause of the interrupt. VIS is a single-byte instruction, typically used at the very beginning of the general interrupt service routine at address 00FF Hex, or shortly after that point, just after the code used for context switching. The VIS instruction determines which enabled and pending interrupt has the highest priority, and causes an indirect jump to the address corresponding to that interrupt source. The jump addresses (vectors) for all possible interrupts sources are stored in a vector table. The vector table may be as long as 32 bytes (maximum of 16 vectors) and resides at the top of the 256-byte block containing the VIS instruction. However, if the VIS instruction is at the very top of a 256-byte block (such as at 00FF Hex), the vector table resides at the top of the next 256-byte block. Thus, if the VIS instruction is located somewhere between 00FF and 01DF Hex (the usual case), the vector table is located between addresses 01E0 and 01FF Hex. If the VIS instruction is located between 01FF and 02DF Hex, then the vector table is located between addresses 02E0 and 02FF Hex, and so on. Each vector is 15 bits long and points to the beginning of a specific interrupt service routine somewhere in the 32 kbyte memory space. Each vector occupies two bytes of the vector table, with the higher-order byte at the lower address. The vectors are arranged in order of interrupt priority. The vector of the maskable interrupt with the lowest rank is located to 0yE0 (higher-order byte) and 0yE1 (lower-order byte). The next priority interrupt is located at 0yE2 and 0yE3, and so forth in increasing rank. The Software Trap has the highest rank and its vector is always located at 0yFE and 0yFF. The number of interrupts which can become active defines the size of the table. Table 4 shows the types of interrupts, the interrupt arbitration ranking, and the locations of the corresponding vectors in the vector table. 25 www.national.com COP888EK Interrupts COP888EK Interrupts (Continued) TABLE 4. Interrupt Vector Table Arbitration Ranking Vector (Note 28) Source Description Address Hi-Low Byte (1) Highest Software INTR Instruction Reserved 0yFE–0yFF 0yFC–0yFD (2) External G0 0yFA–0yFB (3) Timer T0 Underflow 0yF8–0yF9 (4) Timer T1 T1A/Underflow 0yF6–0yF7 (5) Timer T1 T1B 0yF4–0yF5 (6) MICROWIRE/PLUS BUSY Low 0yF2–0yF3 Reserved 0yF0–0yF1 (7) Reserved 0yEE–0yEF (8) Reserved 0yEC–0yED (9) Timer T2 T2A/Underflow 0yEA–0yEB (10) Timer T2 T2B 0yE8–0yE9 (11) Timer T3 T3A/Underflow 0yE6–0yE7 (12) Timer T3 T3B 0yE4–0yE5 (13) Port L/Wakeup Port L Edge 0yE2–0yE3 (14) Lowest Default VIS Instr. Execution 0yE0–0yE1 without Any Interrupts Note 28: y is a variable which represents the VIS block. VIS and the vector table must be located in the same 256-byte block except if VIS is located at the last address of a block. In this case, the table must be in the next block. vector of the active interrupt with the highest arbitration ranking. This vector is read from program memory and placed into the PC which is now pointed to the 1st instruction of the service routine of the active interrupt with the highest arbitration ranking. VIS Execution When the VIS instruction is executed it activates the arbitration logic. The arbitration logic generates an even number between E0 and FE (E0, E2, E4, E6 etc...) depending on which active interrupt has the highest arbitration ranking at the time of the 1st cycle of VIS is executed. For example, if the software trap interrupt is active, FE is generated. If the external interrupt is active and the software trap interrupt is not, then FA is generated and so forth. If the only active interrupt is software trap, than E0 is generated. This number replaces the lower byte of the PC. The upper byte of the PC remains unchanged. The new PC is therefore pointing to the www.national.com Figure 14 illustrates the different steps performed by the VIS instruction. Figure 15 shows a flowchart for the VIS instruction. The non-maskable interrupt pending flag is cleared by the RPND (Reset Non-Maskable Pending Bit) instruction (under certain conditions) and upon RESET. 26 COP888EK Interrupts (Continued) DS012094-29 FIGURE 14. VIS Operation DS012094-30 FIGURE 15. VIS Flowchart 27 www.national.com COP888EK Interrupts (Continued) Programming Example: External Interrupt WAIT: PSW CNTRL RBIT RBIT SBIT SBIT SBIT JP . . . .=0FF VIS =00EF =00EE 0,PORTGC 0,PORTGD IEDG, CNTRL EXEN, PSW GIE, PSW WAIT ; ; ; ; ; G0 pin configured Hi-Z Ext interrupt polarity; falling edge Enable the external interrupt Set the GIE bit Wait for external interrupt ; The interrupt causes a ; branch to address 0FF ; The VIS causes a branch to ;interrupt vector table . . . .=01FA .ADDRW SERVICE ; Vector table (within 256 byte ; of VIS inst.) containing the ext ; interrupt service routine . . INT_EXIT: SERVICE: RETI . . RBIT . . . JP www.national.com EXPND, PSW INT_EXIT ; Interrupt Service Routine ; Reset ext interrupt pend. bit ; Return, set the GIE bit 28 flag; upon return to the first Software Trap routine, the STPND flag will have the wrong state. This will allow maskable interrupts to be acknowledged during the servicing of the first Software Trap. To avoid problems such as this, the user program should contain the Software Trap routine to perform a recovery procedure rather than a return to normal execution. (Continued) NON-MASKABLE INTERRUPT Pending Flag There is a pending flag bit associated with the non-maskable interrupt, called STPND. This pending flag is not memorymapped and cannot be accessed directly by the software. The pending flag is reset to zero when a device Reset occurs. When the non-maskable interrupt occurs, the associated pending bit is set to 1. The interrupt service routine should contain an RPND instruction to reset the pending flag to zero. The RPND instruction always resets the STPND flag. Under normal conditions, the STPND flag is reset by a RPND instruction in the Software Trap service routine. If a programming error or hardware condition (brownout, power supply glitch, etc.) sets the STPND flag without providing a way for it to be cleared, all other interrupts will be locked out. To alleviate this condition, the user can use extra RPND instructions in the main program and in the WATCHDOG service routine (if present). There is no harm in executing extra RPND instructions in these parts of the program. Software Trap The Software Trap is a special kind of non-maskable interrupt which occurs when the INTR instruction (used to acknowledge interrupts) is fetched from program memory and placed in the instruction register. This can happen in a variety of ways, usually because of an error condition. Some examples of causes are listed below. If the program counter incorrectly points to a memory location beyond the available program memory space, the nonexistent or unused memory location returns zeroes which is interpreted as the INTR instruction. If the stack is popped beyond the allowed limit (address 06F Hex), a 7FFF will be loaded into the PC, if this last location in program memory is unprogrammed or unavailable, a Software Trap will be triggered. A Software Trap can be triggered by a temporary hardware condition such as a brownout or power supply glitch. The Software Trap has the highest priority of all interrupts. When a Software Trap occurs, the STPND bit is set. The GIE bit is not affected and the pending bit (not accessible by the user) is used to inhibit other interrupts and to direct the program to the ST service routine with the VIS instruction. Nothing can interrupt a Software Trap service routine except for another Software Trap. The STPND can be reset only by the RPND instruction or a chip Reset. The Software Trap indicates an unusual or unknown error condition. Generally, returning to normal execution at the point where the Software Trap occurred cannot be done reliably. Therefore, the Software Trap service routine should reinitialize the stack pointer and perform a recovery procedure that restarts the software at some known point, similar to a device Reset, but not necessarily performing all the same functions as a device Reset. The routine must also execute the RPND instruction to reset the STPND flag. Otherwise, all other interrupts will be locked out. To the extent possible, the interrupt routine should record or indicate the context of the device so that the cause of the Software Trap can be determined. If the user wishes to return to normal execution from the point at which the Software Trap was triggered, the user must first execute RPND, followed by RETSK rather than RETI or RET. This is because the return address stored on the stack is the address of the INTR instruction that triggered the interrupt. The program must skip that instruction in order to proceed with the next one. Otherwise, an infinite loop of Software Traps and returns will occur. Programming a return to normal execution requires careful consideration. If the Software Trap routine is interrupted by another Software Trap, the RPND instruction in the service routine for the second Software Trap will reset the STPND PORT L INTERRUPTS Port L provides the user with an additional eight fully selectable, edge sensitive interrupts which are all vectored into the same service subroutine. The interrupt from Port L shares logic with the wake up circuitry. The register WKEN allows interrupts from Port L to be individually enabled or disabled. The register WKEDG specifies the trigger condition to be either a positive or a negative edge. Finally, the register WKPND latches in the pending trigger conditions. The GIE (Global Interrupt Enable) bit enables the interrupt function. A control flag, LPEN, functions as a global interrupt enable for Port L interrupts. Setting the LPEN flag will enable interrupts and vice versa. A separate global pending flag is not needed since the register WKPND is adequate. Since Port L is also used for waking the device out of the HALT or IDLE modes, the user can elect to exit the HALT or IDLE modes either with or without the interrupt enabled. If he elects to disable the interrupt, then the device will restart execution from the instruction immediately following the instruction that placed the microcontroller in the HALT or IDLE modes. In the other case, the device will first execute the interrupt service routine and then revert to normal operation. (See HALT MODE for clock option wakeup information.) INTERRUPT SUMMARY The device uses the following types of interrupts, listed below in order of priority: 1. The Software Trap non-maskable interrupt, triggered by the INTR (00 opcode) instruction. The Software Trap is acknowledged immediately. This interrupt service routine can be interrupted only by another Software Trap. The Software Trap should end with two RPND instructions followed by a restart procedure. 2. Maskable interrupts, triggered by an on-chip peripheral block or an external device connected to the device. Under ordinary conditions, a maskable interrupt will not interrupt any other interrupt routine in progress. A maskable interrupt routine in progress can be interrupted by the non-maskable interrupt request. A maskable interrupt routine should end with an RETI instruction or, prior to restoring context, should return to execute the VIS instruction. This is particularly useful when exiting long interrupt service routiness if the time between interrupts is short. In this case the RETI instruction would only be executed when the default VIS routine is reached. 29 www.national.com COP888EK Interrupts COP888EK occur after coming out of reset, if the instruction cycle clock frequency has not reached a minimum specified value, including the case where the oscillator fails to start. WATCHDOG The device contains a WATCHDOG and clock monitor. The WATCHDOG is designed to detect the user program getting stuck in infinite loops resulting in loss of program control or “runaway” programs. The Clock Monitor is used to detect the absence of a clock or a very slow clock below a specified rate on the CKI pin. The WATCHDOG consists of two independent logic blocks: WD UPPER and WD LOWER. WD UPPER establishes the upper limit on the service window and WD LOWER defines the lower limit of the service window. Servicing the WATCHDOG consists of writing a specific value to a WATCHDOG Service Register named WDSVR which is memory mapped in the RAM. This value is composed of three fields, consisting of a 2-bit Window Select, a 5-bit Key Data field, and the 1-bit Clock Monitor Select field. Table 5 shows the WDSVR register. The WDSVR register can be written to only once after reset and the key data (bits 5 through 1 of the WDSVR Register) must match to be a valid write. This write to the WDSVR register involves two irrevocable choices: (i) the selection of the WATCHDOG service window (ii) enabling or disabling of the Clock Monitor. Hence, the first write to WDSVR Register involves selecting or deselecting the Clock Monitor, select the WATCHDOG service window and match the WATCHDOG key data. Subsequent writes to the WDSVR register will compare the value being written by the user to the WATCHDOG service window value and the key data (bits 7 through 1) in the WDSVR Register. Table IV shows the sequence of events that can occur. The user must service the WATCHDOG at least once before the upper limit of the service window expires. The WATCHDOG may not be serviced more than once in every lower limit of the service window. The user may service the WATCHDOG as many times as wished in the time period between the lower and upper limits of the service window. The first write to the WDSVR Register is also counted as a WATCHDOG service. The WATCHDOG has an output pin associated with it. This is the WDOUT pin, on pin 1 of the port G. WDOUT is active low. The WDOUT pin is in the high impedance state in the inactive state. Upon triggering the WATCHDOG, the logic will pull the WDOUT (G1) pin low for an additional 16 tc–32 tc cycles after the signal level on WDOUT pin goes below the lower Schmitt trigger threshold. After this delay, the device will stop forcing the WDOUT output low. The WATCHDOG service window will restart when the WDOUT pin goes high. It is recommended that the user tie the WDOUT pin back to VCC through a resistor in order to pull WDOUT high. A WATCHDOG service while the WDOUT signal is active will be ignored. The state of the WDOUT pin is not guaranteed on reset, but if it powers up low then the WATCHDOG will time out and WDOUT will enter high impedance state. The Clock Monitor forces the G1 pin low upon detecting a clock frequency error. The Clock Monitor error will continue until the clock frequency has reached the minimum specified value, after which the G1 output will enter the high impedance TRI-STATE mode following 16 tc–32 tc clock cycles. The Clock Monitor generates a continual Clock Monitor error if the oscillator fails to start, or fails to reach the minimum specified frequency. The specification for the Clock Monitor is as follows: 1/tc > 10 kHz — No clock rejection. TABLE 5. WATCHDOG Service Register (WDSVR) Window Select Clock Monitor Key Data X X 0 1 1 0 0 Y 7 6 5 4 3 2 1 0 The lower limit of the service window is fixed at 2048 instruction cycles. Bits 7 and 6 of the WDSVR register allow the user to pick an upper limit of the service window. Table 6 shows the four possible combinations of lower and upper limits for the WATCHDOG service window. This flexibility in choosing the WATCHDOG service window prevents any undue burden on the user software. Bits 5, 4, 3, 2 and 1 of the WDSVR register represent the 5-bit Key Data field. The key data is fixed at 01100. Bit 0 of the WDSVR Register is the Clock Monitor Select bit. TABLE 6. WATCHDOG Service Window Select WDSVR WDSVR Clock Service Window Bit 7 Bit 6 Monitor (Lower-Upper Limits) 0 0 x 2048–8k tC Cycles 0 1 x 2048–16k tC Cycles 1 0 x 2048–32k tC Cycles 1 1 x 2048–64k tC Cycles x x 0 Clock Monitor Disabled x x 1 Clock Monitor Enabled Clock Monitor 1/tc < 10 Hz — Guaranteed clock rejection. The Clock Monitor aboard the device can be selected or deselected under program control. The Clock Monitor is guaranteed not to reject the clock if the instruction cycle clock (1/ tc) is greater or equal to 10 kHz. This equates to a clock input rate on CKI of greater or equal to 100 kHz. WATCHDOG AND CLOCK MONITOR SUMMARY The following salient points regarding the WATCHDOG and CLOCK MONITOR should be noted: WATCHDOG Operation The WATCHDOG and Clock Monitor are disabled during reset. The device comes out of reset with the WATCHDOG armed, the WATCHDOG Window Select bits (bits 6, 7 of the WDSVR Register) set, and the Clock Monitor bit (bit 0 of the WDSVR Register) enabled. Thus, a Clock Monitor error will www.national.com 30 • Both the WATCHDOG and CLOCK MONITOR detector circuits are inhibited during RESET. • Following RESET, the WATCHDOG and CLOCK MONITOR are both enabled, with the WATCHDOG having he maximum service window selected. • The WATCHDOG service window and CLOCK MONITOR enable/disable option can only be changed once, during the initial WATCHDOG service following RESET. The subroutine stack grows down for each call (jump to subroutine), interrupt, or PUSH, and grows up for each return or POP. The stack pointer is initialized to RAM location 06F Hex during reset. Consequently, if there are more returns than calls, the stack pointer will point to addresses 070 and 071 Hex (which are undefined RAM). Undefined RAM from addresses 070 to 07F (Segment 0), 140 to 17F (Segment 1), and all other segments (i.e., Segments 2 … etc.) is read as all 1’s, which in turn will cause the program to return to address 7FFF Hex. This is an undefined ROM location and the instruction fetched (all 0’s) from this location will generate a software interrupt signaling an illegal condition. Thus, the chip can detect the following illegal conditions: 1. Executing from undefined ROM 2. Over “POP”ing the stack by having more returns than calls. When the software interrupt occurs, the user can re-initialize the stack pointer and do a recovery procedure before restarting (this recovery program is probably similar to that following reset, but might not contain the same program initialization procedures). The recovery program should reset the software interrupt pending bit using the RPND instruction. (Continued) • The initial WATCHDOG service must match the key data value in the WATCHDOG Service register WDSVR in order to avoid a WATCHDOG error. • Subsequent WATCHDOG services must match all three data fields in WDSVR in order to avoid WATCHDOG errors. • The correct key data value cannot be read from the WATCHDOG Service register WDSVR. Any attempt to read this key data value of 01100 from WDSVR will read as key data value of all 0’s. • The WATCHDOG detector circuit is inhibited during both the HALT and IDLE modes. • The CLOCK MONITOR detector circuit is active during both the HALT and IDLE modes. Consequently, the device inadvertently entering the HALT mode will be detected as a CLOCK MONITOR error (provided that the CLOCK MONITOR enable option has been selected by the program). • With the single-pin R/C oscillator mask option selected and the CLKDLY bit reset, the WATCHDOG service window will resume following HALT mode from where it left off before entering the HALT mode. • With the crystal oscillator mask option selected, or with the single-pin R/C oscillator mask option selected and the CLKDLY bit set, the WATCHDOG service window will be set to its selected value from WDSVR following HALT. Consequently, the WATCHDOG should not be serviced for at least 2048 instruction cycles following HALT, but must be serviced within the selected window to avoid a WATCHDOG error. • • The IDLE timer T0 is not initialized with RESET. • A hardware WATCHDOG service occurs just as the device exits the IDLE mode. Consequently, the WATCHDOG should not be serviced for at least 2048 instruction cycles following IDLE, but must be serviced within the selected window to avoid a WATCHDOG error. • Following RESET, the initial WATCHDOG service (where the service window and the CLOCK MONITOR enable/ disable must be selected) may be programmed anywhere within the maximum service window (65,536 instruction cycles) initialized by RESET. Note that this initial WATCHDOG service may be programmed within the initial 2048 instruction cycles without causing a WATCHDOG error. MICROWIRE/PLUS MICROWIRE/PLUS is a serial synchronous communications interface. The MICROWIRE/PLUS capability enables the device to interface with any of National Semiconductor’s MICROWIRE peripherals (i.e. A/D converters, display drivers, E2PROMs etc.) and with other microcontrollers which support the MICROWIRE interface. It consists of an 8-bit serial shift register (SIO) with serial data input (SI), serial data output (SO) and serial shift clock (SK). Figure 16 shows a block diagram of the MICROWIRE/PLUS logic. The user can sync in to the IDLE counter cycle with an IDLE counter (T0) interrupt or by monitoring the T0PND flag. The T0PND flag is set whenever the thirteenth bit of the IDLE counter toggles (every 4096 instruction cycles). The user is responsible for resetting the T0PND flag. DS012094-16 FIGURE 16. MICROWIRE/PLUS Block Diagram The shift clock can be selected from either an internal source or an external source. Operating the MICROWIRE/PLUS arrangement with the internal clock source is called the Master mode of operation. Similarly, operating the MICROWIRE/ PLUS arrangement with an external shift clock is called the Slave mode of operation. The CNTRL register is used to configure and control the MICROWIRE/PLUS mode. To use the MICROWIRE/PLUS, the MSEL bit in the CNTRL register is set to one. In the master mode, the SK clock rate is selected by the two bits, SL0 and SL1, in the CNTRL register. details the different clock rates that may be selected. Detection of Illegal Conditions The device can detect various illegal conditions resulting from coding errors, transient noise, power supply voltage drops, runaway programs, etc. Reading of undefined ROM gets zeros. The opcode for software interrupt is zero. If the program fetches instructions from undefined ROM, this will force a software interrupt, thus signaling that an illegal condition has occurred. 31 www.national.com COP888EK WATCHDOG Operation COP888EK MICROWIRE/PLUS (Continued) TABLE 7. WATCHDOG Service Actions Key Window Clock Data Data Monitor Action Match Match Match Don’t Care Mismatch Don’t Care Error: Generate WATCHDOG Output Mismatch Don’t Care Don’t Care Error: Generate WATCHDOG Output Don’t Care Don’t Care Mismatch Error: Generate WATCHDOG Output Valid Service: Restart Service Window onto the G Port. The SK pin must be selected as an input and the SO pin is selected as an output pin by setting and resetting the appropriate bits in the Port G configuration register. Table 9 summarizes the settings required to enter the Slave mode of operation. The user must set the BUSY flag immediately upon entering the Slave mode. This will ensure that all data bits sent by the Master will be shifted properly. After eight clock pulses the BUSY flag will be cleared and the sequence may be repeated. TABLE 8. MICROWIRE/PLUS Master Mode Clock Select SL1 SL0 0 0 2 x tc SK 0 1 4 x tc 1 x 8 x tc Where tc is the instruction cycle clock MICROWIRE/PLUS OPERATION Setting the BUSY bit in the PSW register causes the MICROWIRE/PLUS to start shifting the data. It gets reset when eight data bits have been shifted. The user may reset the BUSY bit by software to allow less than 8 bits to shift. If enabled, an interrupt is generated when eight data bits have been shifted. The device may enter the MICROWIRE/PLUS mode either as a Master or as a Slave. Figure 17 shows how two microcontroller devices and several peripherals may be interconnected using the MICROWIRE/PLUS arrangements. TABLE 9. MICROWIRE/PLUS Mode Settings This table assumes that the control flag MSEL is set. Warning: The SIO register should only be loaded when the SK clock is low. Loading the SIO register while the SK clock is high will result in undefined data in the SIO register. SK clock is normally low when not shifting. Setting the BUSY flag when the input SK clock is high in the MICROWIRE/PLUS slave mode may cause the current SK clock for the SIO shift register to be narrow. For safety, the BUSY flag should only be set when the input SK clock is low. G5 (SK) G4 G5 Config. Bit Fun. Fun. 1 1 SO Int. TRI- Operation MICROWIRE/PLUS SK Master Int. MICROWIRE/PLUS 0 1 STATE SK Master 1 0 SO Ext. MICROWIRE/PLUS SK Slave 0 0 TRI- Ext. MICROWIRE/PLUS STATE SK Slave Alternate SK Phase Operation The device allows either the normal SK clock or an alternate phase SK clock to shift data in and out of the SIO register. In both the modes the SK is normally low. In the normal mode data is shifted in on the rising edge of the SK clock and the data is shifted out on the falling edge of the SK clock. The SIO register is shifted on each falling edge of the SK clock. In the alternate SK phase operation, data is shifted in on the falling edge of the SK clock and shifted out on the rising edge of the SK clock. A control flag, SKSEL, allows either the normal SK clock or the alternate SK clock to be selected. Resetting SKSEL causes the MICROWIRE/PLUS logic to be clocked from the normal SK signal. Setting the SKSEL flag selects the alternate SK clock. The SKSEL is mapped into the G6 configuration bit. The SKSEL flag will power up in the reset condition, selecting the normal SK signal. MICROWIRE/PLUS Master Mode Operation In the MICROWIRE/PLUS Master mode of operation the shift clock (SK) is generated internally by the device. The MICROWIRE Master always initiates all data exchanges. The MSEL bit in the CNTRL register must be set to enable the SO and SK functions onto the G Port. The SO and SK pins must also be selected as outputs by setting appropriate bits in the Port G configuration register. Table 9 summarizes the bit settings required for Master mode of operation. MICROWIRE/PLUS Slave Mode Operation In the MICROWIRE/PLUS Slave mode of operation the SK clock is generated by an external source. Setting the MSEL bit in the CNTRL register enables the SO and SK functions www.national.com G4 (SO) Config. Bit 32 COP888EK MICROWIRE/PLUS (Continued) DS012094-17 FIGURE 17. MICROWIRE/PLUS Application 33 www.national.com COP888EK Memory Map Address All RAM, ports and registers (except A and PC) are mapped into data memory address space. Contents S/ADD REG xxD0 Port L Data Register xxD1 Port L Configuration Register xxD2 Port L Input Pins (Read Only) xxD3 Reserved for Port L xxD4 Port G Data Register Unused RAM Address Space (Reads Undefined Data) xxD5 Port G Configuration Register xxD6 Port G Input Pins (Read Only) Timer T3 Lower Byte xxD7 Port I Input Pins (Read Only) Timer T3 Upper Byte xxD8 Port C Data Register xxB2 Timer T3 Autoload Register T3RA Lower Byte xxD9 Port C Configuration Register xxDA Port C Input Pins (Read Only) xxB3 Timer T3 Autoload Register T3RA Upper Byte xxDB Reserved for Port C xxDC Port D Timer T3 Autoload Register T3RB Lower Byte xxDD to xxDF Reserved xxE0 to xxE5 Reserved xxB5 Timer T3 Autoload Register T3RB Upper Byte xxE6 Timer T1 Autoload Register T1RB Lower Byte xxB6 Timer T3 Control Register xxE7 xxB7 Comparator Select Register (CMPSL) Timer T1 Autoload Register T1RB Upper Byte Address Contents S/ADD REG 0000 to 006F On-Chip RAM bytes (112 bytes) 0070 to 007F Unused RAM Address Space (Reads As All Ones) xx80 to xxAF xxB0 xxB1 xxB4 xxB8 to xxBF Reserved xxE8 ICNTRL Register xxC0 Timer T2 Lower Byte xxE9 MICROWIRE/PLUS Shift Register xxC1 Timer T2 Upper Byte xxEA Timer T1 Lower Byte xxC2 Timer T2 Autoload Register T2RA Lower Byte xxEB Timer T1 Upper Byte xxEC Timer T1 Autoload Register T1RA Lower Byte xxED Timer T1 Autoload Register T1RA Upper Byte xxEE CNTRL Control Register xxEF PSW Register xxC3 Timer T2 Autoload Register T2RA Upper Byte xxC4 Timer T2 Autoload Register T2RB Lower Byte xxC5 Timer T2 Autoload Register T2RB Upper Byte xxC6 Timer T2 Control Register xxC7 WATCHDOG Service Register (Reg:WDSVR) xxC8 xxC9 MIWU Edge Select Register (Reg:WKEDG) MIWU Enable Register (Reg:WKEN) xxCA MIWU Pending Register (Reg:WKPND) xxCB Reserved xxCC Reserved xxCD to xxCF Reserved www.national.com xxF0 to xxFB On-Chip RAM Mapped as Registers xxFC X Register xxFD SP Register xxFE B Register xxFF S Register 0100 to 017F On-Chip 128 RAM Bytes Reading memory locations 0070H–007FH (Segment 0) will return all ones. Reading unused memory locations 0080H–00AFH (Segment 0) will return undefined data. Reading memory locations from other unused Segments (i.e., Segment 2, Segment 3, … etc.) will return undefined data. 34 Indirect There are ten addressing modes, six for operand addressing and four for transfer of control. This mode is used with the JID instruction. The contents of the accumulator are used as a partial address (lower 8 bits of PC) for accessing a location in the program memory. The contents of this program memory location serve as a partial address (lower 8 bits of PC) for the jump to the next instruction. OPERAND ADDRESSING MODES Register Indirect This is the “normal” addressing mode. The operand is the data memory addressed by the B pointer or X pointer. Register Indirect (with auto post increment or decrement of pointer) This addressing mode is used with the LD and X instructions. The operand is the data memory addressed by the B pointer or X pointer. This is a register indirect mode that automatically post increments or decrements the B or X register after executing the instruction. Direct The instruction contains an 8-bit address field that directly points to the data memory for the operand. Immediate The instruction contains an 8-bit immediate field as the operand. Short Immediate This addressing mode is used with the Load B Immediate instruction. The instruction contains a 4-bit immediate field as the operand. Indirect This addressing mode is used with the LAID instruction. The contents of the accumulator are used as a partial address (lower 8 bits of PC) for accessing a data operand from the program memory. Note: The VIS is a special case of the Indirect Transfer of Control addressing mode, where the double byte vector associated with the interrupt is transferred from adjacent addresses in the program memory into the program counter (PC) in order to jump to the associated interrupt service routine. Instruction Set Register and Symbol Definition Registers A 8-Bit Accumulator Register B 8-Bit Address Register X 8-Bit Address Register S 8-Bit Segment Register SP 8-Bit Stack Pointer Register PC 15-Bit Program Counter Register PU Upper 7 Bits of PC PL Lower 8 Bits of PC C 1 Bit of PSW Register for Carry HC 1 Bit of PSW Register for Half Carry GIE 1 Bit of PSW Register for Global Interrupt Enable TRANSFER OF CONTROL ADDRESSING MODES VU Interrupt Vector Upper Byte Relative This mode is used for the JP instruction, with the instruction field being added to the program counter to get the new program location. JP has a range from −31 to +32 to allow a 1-byte relative jump (JP + 1 is implemented by a NOP instruction). There are no “pages” when using JP, since all 15 bits of PC are used. VL Interrupt Vector Lower Byte [B] Memory Indirectly Addressed by B Register [X] Memory Indirectly Addressed by X Register MD Direct Addressed Memory Mem Direct Addressed Memory or [B] Absolute This mode is used with the JMP and JSR instructions, with the instruction field of 12 bits replacing the lower 12 bits of the program counter (PC). This allows jumping to any location in the current 4k program memory segment. Meml Direct Addressed Memory or [B] or Immediate Data Symbols Absolute Long This mode is used with the JMPL and JSRL instructions, with the instruction field of 15 bits replacing the entire 15 bits of the program counter (PC). This allows jumping to any location in the current 4k program memory space. 35 Imm 8-Bit Immediate Data Reg Register Memory: Addresses F0 to FF (Includes B, X and SP) Bit ← Bit Number (0 to 7) ↔ Exchanged with Loaded with www.national.com COP888EK Addressing Modes COP888EK Instruction Set (Continued) INSTRUCTION SET A← A + Meml A← A + Meml + C, C← Carry HC← Half Carry ADD A,Meml ADD ADC A,Meml ADD with Carry SUBC A,Meml Subtract with Carry A← A − MemI + C, C← Carry HC← Half Carry AND A,Meml Logical AND A← A and Meml ANDSZ A,Imm Logical AND Immed., Skip if Zero OR A,Meml Logical OR Skip next if (A and Imm) = 0 A← A or Meml XOR A,Meml Logical EXclusive OR A← A xor Meml IFEQ MD,Imm IF EQual Compare MD and Imm, Do next if MD = Imm Compare A and Meml, Do next if A = Meml IFEQ A,Meml IF EQual IFNE A,Meml IF Not Equal Compare A and Meml, Do next if A ≠ Meml IFGT A,Meml IF Greater Than If B Not Equal Compare A and Meml, Do next if A > Meml Do next if lower 4 bits of B ≠ Imm IFBNE # DRSZ Reg Decrement Reg., Skip if Zero SBIT #,Mem Set BIT Reg←Reg − 1, Skip if Reg = 0 1 to bit, Mem (bit = 0 to 7 immediate) RBIT #,Mem Reset BIT 0 to bit, Mem IFBIT #,Mem IF BIT If bit in A or Mem is true do next instruction Reset PeNDing Flag Reset Software Interrupt Pending Flag RPND X A,Mem EXchange A with Memory A↔Mem X A,[X] EXchange A with Memory [X] LD A,Meml LoaD A with Memory A↔[X] A←Meml LD A,[X] LoaD A with Memory [X] LD B,Imm LoaD B with Immed. LD Mem,Imm LoaD Memory Immed LD Reg,Imm LoaD Register Memory Immed. X A, [B ± ] EXchange A with Memory [B] X A, [X ± ] EXchange A with Memory [X] LD A, [B ± ] LoaD A with Memory [B] LD A, [X ± ] LoaD A with Memory [X] LD [B ± ],Imm LoaD Memory [B] Immed. CLR A CLeaR A INC A INCrement A DEC A DECrement A LAID A←[X] B← Imm Mem← Imm Reg← Imm A↔[B], (B← B ± 1) A↔[X], (X← ± 1) A← [B], (B← B ± 1) A← [X], (X← X ± 1) [B]← Imm, (B←B ± 1) A←0 A←A + 1 A←A − 1 A← ROM (PU,A) Load A InDirect from ROM DCOR A Decimal CORrect A RRC A Rotate A Right thru C A← BCD correction of A (follows ADC, SUBC) C→ A7 →… → A0 → C RLC A Rotate A Left thru C C←A7 ← …← A0 ←C SWAP A SWAP nibbles of A SC Set C RC Reset C A7…A4↔A3…A0 C← 1, HC← 1 C←0, HC← 0 IFC IF C IF C is true, do next instruction IFNC IF Not C If C is not true, do next instruction SP← SP + 1, A← [SP] POP A POP the stack into A PUSH A PUSH A onto the stack VIS [SP]← A, SP← SP − 1 PU← [VU], PL← [VL] Vector to Interrupt Service Routine JMPL Addr. Jump absolute Long JMP Addr. Jump absolute PC← ii (ii = 15 bits, 0 to 32k) PC9…0← i (i = 12 bits) JP Disp. Jump relative short PC← PC + r (r is −31 to +32, except 1) www.national.com 36 COP888EK Instruction Set (Continued) JSRL Addr. Jump SubRoutine Long JSR Addr Jump SubRoutine JID Jump InDirect RET RETurn from subroutine RETSK RETurn and SKip RETI RETurn from Interrupt INTR Generate an Interrupt NOP No OPeration [SP]← PL, [SP−1]← PU,SP−2, PC← ii [SP]← PL, [SP−1]← PU,SP−2, PC9…0← i PL← ROM (PU,A) SP + 2, PL← [SP], PU← [SP−1] SP + 2, PL← [SP],PU← [SP−1] SP + 2, PL ← [SP],PU← [SP−1],GIE← 1 [SP]← PL, [SP−1]← PU, SP−2, PC← 0FF PC← PC + 1 37 www.national.com COP888EK Instruction Set Instructions Using A & C (Continued) Instruction Execution Time CLRA 1/1 Most instructions are single byte (with immediate addressing mode instructions taking two bytes). INCA 1/1 DECA 1/1 Most single byte instructions take one cycle time to execute. LAID 1/3 • DCOR 1/1 RRCA 1/1 RLCA 1/1 SWAPA 1/1 SC 1/1 RC 1/1 IFC 1/1 IFNC 1/1 PUSHA 1/3 POPA 1/3 ANDSZ 2/2 Skipped instructions require x number of cycles to be skipped, where x equals the number of bytes in the skipped instruction opcode. See the BYTES and CYCLES per INSTRUCTION table for details. Bytes and Cycles per Instruction The following table shows the number of bytes and cycles for each instruction in the format of byte/cycle. Arithmetic and Logic Instructions [B] Direct Immed. ADD 1/1 3/4 2/2 ADC 1/1 3/4 2/2 SUBC 1/1 3/4 2/2 AND 1/1 3/4 2/2 JMPL 3/4 OR 1/1 3/4 2/2 JMP 2/3 XOR 1/1 3/4 2/2 JP 1/3 IFEQ 1/1 3/4 2/2 JSRL 3/5 IFNE 1/1 3/4 2/2 JSR 2/5 IFGT 1/1 3/4 2/2 JID 1/3 IFBNE 1/1 VIS 1/5 1/3 RET 1/5 DRSZ Transfer of Control Instructions SBIT 1/1 3/4 RETSK 1/5 RBIT 1/1 3/4 RETI 1/5 IFBIT 1/1 3/4 INTR 1/7 NOP 1/1 RPND 1/1 Memory Transfer Instructions Register Direct Immed. Indirect [B] [X] X A, (Note 29) 1/1 1/3 2/3 LD A, (Note 29) 1/1 1/3 2/3 [B+, B−] LD B, Imm 2/2 3/3 1/3 (IF B < 16) (IF B > 15) LD Reg, Imm 2/3 IFEQ MD, Imm 3/3 2/2 Note 29: Memory location addressed by B or X or directly. www.national.com 1/3 1/2 2/2 2/2 38 [X+, X−] 1/2 1/1 LD B, Imm LD Mem, Imm Register Indirect Auto Incr. & Decr. JP−19 JP−18 JP−17 JP−16 JP−3 JP−2 JP−1 JP−0 C DRSZ 0F0 DRSZ 0F1 DRSZ 0F2 DRSZ 0F3 DRSZ 0F4 DRSZ 0F5 DRSZ 0F6 DRSZ 0F7 DRSZ 0F8 DRSZ 0F9 DRSZ 0FA DRSZ 0FB DRSZ 0FC DRSZ 0FD DRSZ 0FE DRSZ 0FF D LD 0F0, #i LD 0F1,#i LD 0F2,#i LD 0F3,#i LD 0F4,#i LD 0F5,#i LD 0F6,#i LD 0F7,#i LD 0F8,#i LD 0F9,#i LD 0FA,#i LD 0FB,#i LD 0FC,#i LD 0FD,#i LD 0FE,#i LD 0FF,#i where, i is the immediate data Md is a directly addressed memory location * is an unused opcode (see following table) JP−20 JP−24 JP−8 JP−4 JP−25 JP−9 JP−21 JP−26 JP−10 JP−5 JP−27 JP−11 JP−22 JP−28 JP−12 JP−6 JP−29 JP−13 JP−23 JP−30 JP−14 JP−7 E JP−31 F JP−15 Opcode Table B * LD A,[X] DIR LD Md,#i LD A,[X−] LD A,[X+] * NOP * X A,[X] * * X A,[X−] X A,[X+] * RRCA A 9 * LD A,#i OR A,#i XOR A,#i AND A,#i ADD A,#i IFGT A,#i IFEQ A,#i SUBC A,#i ADC A,#i * LD A,[B] JSRL * LD [B],#i LD A,Md JMPL X A,Md LD LD A,[B−] [B−],#i LD LD A,[B+] [B+],#i * * * X A,[B] JID LAID X A,[B−] X A,[B+] SC RC 8 RETI RET RETSK * DECA INCA IFNC IFC OR A,[B] XOR A,[B] AND A,[B] ADD A,[B] IFGT A,[B] IFEQ A,[B] SUBC A,[B] ADC A,[B] CLRA * * * * 6 5 LD B,0A LD B,0B LD B,0C LD B,0D LD B,0E LD B,0F SBIT 7,[B] SBIT 6,[B] SBIT 5,[B] SBIT 4,[B] SBIT 3,[B] SBIT 2,[B] SBIT 1,[B] SBIT 0,[B] IFBIT 7,[B] RBIT 7,[B] RBIT 6,[B] RBIT 5,[B] RBIT 4,[B] RBIT 3,[B] RBIT 2,[B] RBIT 1,[B] RBIT 0,[B] * LD B,0 LD B,1 LD B,2 LD B,3 LD B,4 LD B,5 LD B,6 LD B,7 LD B,8 IFBIT DCORA LD B,9 6,[B] IFBIT SWAPA 5,[B] IFBIT 4,[B] IFBIT 3,[B] IFBIT 2,[B] IFBIT 1,[B] IFBIT 0,[B] 7 Bits 7–4 4 IFBNE 0F IFBNE 0E IFBNE 0D IFBNE 0C IFBNE 0B IFBNE 0A IFBNE 9 IFBNE 8 IFBNE 7 IFBNE 6 IFBNE 5 IFBNE 4 IFBNE 3 IFBNE 2 IFBNE 1 IFBNE 0 3 2 1 JP+26 JP+25 JP+24 JP+23 JP+22 JP+21 JP+20 JP+19 JP+18 JP+17 JSR JMP JP+32 0F00–0FFF 0F00–0FFF JSR JMP JP+31 0E00–0EFF 0E00–0EFF JSR JMP JP+30 0D00–0DFF 0D00–0DFF JSR JMP JP+29 0C00–0CFF 0C00–0CFF JSR JMP JP+28 0B00–0BFF 0B00–0BFF JSR JMP JP+27 0A00–0AFF 0A00–0AFF JSR JMP 0900–09FF 0900–09FF JSR JMP 0800–08FF 0800–08FF JSR JMP 0700–07FF 0700–07FF JSR JMP 0600–06FF 0600–06FF JSR JMP 0500–05FF 0500–05FF JSR JMP 0400–04FF 0400–04FF JSR JMP 0300–03FF 0300–03FF JSR JMP 0200–02FF 0200–02FF JSR JMP 0100–01FF 0100–01FF JSR JMP 0000–00FF 0000–00FF 0 B A 9 8 7 6 5 4 3 2 1 0 JP+16 JP+15 F E JP+14 D JP+13 C JP+12 JP+11 JP+10 JP+9 JP+8 JP+7 JP+6 JP+5 JP+4 JP+3 JP+2 INTR Bits 3–0 COP888EK 39 www.national.com COP888EK Mask Options • The mask programmable options are shown below. The options are programmed at the same time as the ROM pattern submission. COP8 Integrated Software/Hardware Design Development Kits • OPTION 1: CLOCK CONFIGURATION = 1 Crystal Oscillator (CKI/10) G7 (CKO) is clock generator output to crystal/resonator CKI is the clock input = 2 Single-pin RC controlled oscillator (CKI/10) G7 is available as a HALT restart and/or general purpose input OPTION 2: HALT = 1 Enable HALT mode = 2 Disable HALT mode OPTION 3: BONDING OPTIONS = 1 44-Pin PLCC = 2 40-Pin DIP = 3 N/A = 4 28-Pin DIP = 5 28-Pin SO COP8-DM: Moderate cost Debug Module from MetaLink. A Windows based, real-time in-circuit emulation tool with COP8 device programmer. Includes COP8-NSDEV, DriveWay COP8 Demo, MetaLink Debugger, power supply, emulation cables and adapters. COP8 Development Languages and Environments OVERVIEW National is engaged with an international community of independent 3rd party vendors who provide hardware and software development tool support. Through National’s interaction and guidance, these tools cooperate to form a choice of tools that fits each developer’s needs. This section provides a summary of the tool and development kits currently available. Up-to-date information, selection guides, free tools, demos, updates, and purchase information can be obtained at our web site at: www.national.com/cop8. SUMMARY OF TOOLS COP8 Evaluation Tools COP8–NSEVAL: Free Software Evaluation package for Windows. A fully integrated evaluation environment for COP8, including versions of WCOP8 IDE (Integrated Development Environment), COP8-NSASM, COP8-MLSIM, COP8C, DriveWay™ COP8, Manuals, and other COP8 information. • COP8 — NSASM: Free COP8 Assembler v5 for Win32. Macro assembler, linker, and librarian for COP8 software development. Supports all COP8 devices. (DOS/Win16 v4.10.2 available with limited support). • COP8–MLSIM: Free Instruction Level Simulator tool for Windows. For testing and debugging software instructions only (No I/O or interrupt support). • COP8–EPU: Very Low cost COP8 Evaluation & Programming Unit. Windows based evaluation and hardware-simulation tool, with COP8 device programmer and erasable samples. Includes COP8-NSDEV, Driveway COP8 Demo, MetaLink Debugger, I/O cables and power supply. • COP8–EVAL-ICUxx: Very Low cost evaluation and design test board for COP8ACC and COP8SGx Families, from ICU. Real-time environment with add-on A/D, D/A, and EEPROM. Includes software routines and reference designs. www.national.com COP8-EPU: Very Low cost Evaluation & Programming Unit. Windows based development and hardwaresimulation tool for COPSx/xG families, with COP8 device programmer and samples. Includes COP8-NSDEV, Driveway COP8 Demo, MetaLink Debugger, cables and power supply. • • COP8-NSASM: Free COP8 Assembler v5 for Win32. Macro assembler, linker, and librarian for COP8 software development. Supports all COP8 devices. (DOS/Win16 v4.10.2 available with limited support). (Compatible with WCOP8 IDE, COP8C, and DriveWay COP8). • COP8-NSDEV: Very low cost Software Development Package for Windows. An integrated development environment for COP8, including WCOP8 IDE, COP8NSASM, COP8-MLSIM. • COP8C: Moderately priced C Cross-Compiler and Code Development System from Byte Craft (no code limit). Includes BCLIDE (Byte Craft Limited Integrated Development Environment) for Win32, editor, optimizing C CrossCompiler, macro cross assembler, BC-Linker, and MetaLink tools support. (DOS/SUN versions available; Compiler is installable under WCOP8 IDE; Compatible with DriveWay COP8). • EWCOP8-KS: Very Low cost ANSI C-Compiler and Embedded Workbench from IAR (Kickstart version: COP8Sx/Fx only with 2k code limit; No FP). A fully integrated Win32 IDE, ANSI C-Compiler, macro assembler, editor, linker, Liberian, C-Spy simulator/debugger, PLUS MetaLink EPU/DM emulator support. • EWCOP8-AS: Moderately priced COP8 Assembler and Embedded Workbench from IAR (no code limit). A fully integrated Win32 IDE, macro assembler, editor, linker, librarian, and C-Spy high-level simulator/debugger with I/O and interrupts support. (Upgradeable with optional C-Compiler and/or MetaLink Debugger/Emulator support). • EWCOP8-BL: Moderately priced ANSI C-Compiler and Embedded Workbench from IAR (Baseline version: All COP8 devices; 4k code limit; no FP). A fully integrated Win32 IDE, ANSI C-Compiler, macro assembler, editor, linker, librarian, and C-Spy high-level simulator/debugger. (Upgradeable; CWCOP8-M MetaLink tools interface support optional). • EWCOP8: Full featured ANSI C-Compiler and Embedded Workbench for Windows from IAR (no code limit). A fully integrated Win32 IDE, ANSI C-Compiler, macro assembler, editor, linker, librarian, and C-Spy high-level simulator/debugger. (CWCOP8-M MetaLink tools interface support optional). Development Support • Manuals, Applications Notes, Literature: Available free from our web site at: www.national.com/cop8. 40 COP888EK Development Support (Continued) • EWCOP8-M: Full featured ANSI C-Compiler and Embedded Workbench for Windows from IAR (no code limit). A fully integrated Win32 IDE, ANSI C-Compiler, macro assembler, editor, linker, librarian, C-Spy high-level simulator/debugger, PLUS MetaLink debugger/hardware interface (CWCOP8-M). COP8 Productivity Enhancement Tools • WCOP8 IDE: Very Low cost IDE (Integrated Development Environment) from KKD. Supports COP8C, COP8NSASM, COP8-MLSIM, DriveWay COP8, and MetaLink debugger under a common Windows Project Management environment. Code development, debug, and emulation tools can be launched from the project window framework. • DriveWay-COP8: Low cost COP8 Peripherals Code Generation tool from Aisys Corporation. Automatically generates tested and documented C or Assembly source code modules containing I/O drivers and interrupt handlers for each on-chip peripheral. Application specific code can be inserted for customization using the integrated editor. (Compatible with COP8-NSASM, COP8C, and WCOP8 IDE.) • COP8-UTILS: Free set of COP8 assembly code examples, device drivers, and utilities to speed up code development. • COP8-MLSIM: Free Instruction Level Simulator tool for Windows. For testing and debugging software instructions only (No I/O or interrupt support). COP8 Real-Time Emulation Tools • COP8-DM: MetaLink Debug Module. A moderately priced real-time in-circuit emulation tool, with COP8 device programmer. Includes COP8-NSDEV, DriveWay COP8 Demo, MetaLink Debugger, power supply, emulation cables and adapters. • IM-COP8: MetaLink iceMASTER ® . A full featured, realtime in-circuit emulator for COP8 devices. Includes COP8-NSDEV, Driveway COP8 Demo, MetaLink Windows Debugger, and power supply. Package-specific probes and surface mount adaptors are ordered separately. COP8 Device Programmer Support • MetaLink’s EPU and Debug Module include development device programming capability for COP8 devices. • Third-party programmers and automatic handling equipment cover needs from engineering prototype and pilot production, to full production environments. • Factory programming available for high-volume requirements. 41 www.national.com COP888EK Development Support (Continued) TOOLS ORDERING NUMBERS FOR THE COP888EK FAMILY DEVICES Vendor National Tools Order Number Cost Notes COP8-NSEVAL COP8-NSEVAL Free Web site download COP8-NSASM COP8-NSASM Free Included in EPU and DM. Web site download COP8-MLSIM COP8-MLSIM Free Included in EPU and DM. Web site download COP8-NSDEV COP8-NSDEV VL Included in EPU and DM. Order CD from website COP8-EPU Not available for this device COP8-DM Contact MetaLink Development Devices COP87L84EK COP87L88EK VL 16k OTP devices. IM-COP8 Contact MetaLink MetaLink COP8-EPU Not available for this device COP8-DM DM4-COP8-888EK (10 MHz), plus PS-10, plus DM-COP8/xxx (ie. 28D) M Included p/s (PS-10), target cable of choice (DIP or PLCC; i.e. DM-COP8/28D), 16/20/28/40 DIP/SO and 44 PLCC programming sockets. Add target adapter (if needed) DM Target Adapters MHW-CNV39 L DM target converters for 28SO IM-COP8 IM-COP8-AD-464 (-220) (10 MHz maximum) H Base unit 10 MHz; -220 = 220V; add probe card (required) and target adapter (if needed); included software and manuals IM Probe Card IM Probe Target Adapter PC-884EK28DW-AD-10 M 10 MHz 28 DIP probe card; 2.5V to 6.0V PC-888EK40DW-AD-10 M 10 MHz 40 DIP probe card; 2.5V to 6.0V PC-888EK44PW-AD-10 M 10 MHz 44 PLCC probe card; 2.5V to 6.0V MHW-SOIC28 L 28 pin SOIC adapter for probe card VL Included in EPU and DM ICU COP8-EVAL Not available for this device KKD WCOP8-IDE WCOP8-IDE IAR EWCOP8-xx See summary above L-H Included all software and manuals Byte Craft COP8C COP8C M Included all software and manuals Aisys DriveWay COP8 DriveWay COP8 L Included all software and manuals Contact vendors L-H For approved programmer listings and vendor information, go to our OTP support page at: www.national.com/cop8 OTP Programmers Cost: Free; VL = < $100; L = $100 - $300; M = $300 - $1k; H = $1k - $3k; VH = $3k - $5k www.national.com 42 (Continued) WHERE TO GET TOOLS Tools are ordered directly from the following vendors. Please go to the vendor’s web site for current listings of distributors. Vendor Aisys Home Office Electronic Sites U.S.A.: Santa Clara, CA www.aisysinc.com 1-408-327-8820 [email protected] Other Main Offices Distributors fax: 1-408-327-8830 Byte Craft U.S.A. www.bytecraft.com 1-519-888-6911 [email protected] Distributors fax: 1-519-746-6751 Hilton U.S.A.: Milford, PA www.erols.com/sjg1/hilton.htm [email protected] IAR Sweden: Uppsala www.iar.se U.S.A.: San Francisco +46 18 16 78 00 [email protected] 1-415-765-5500 fax: +46 18 16 78 38 [email protected] fax: 1-415-765-5503 [email protected] U.K.: London [email protected] +44 171 924 33 34 fax: +44 171 924 53 41 Germany: Munich +49 89 470 6022 fax: +49 89 470 956 ICU Sweden: Polygonvaegen www.icu.se Switzeland: Hoehe +46 8 630 11 20 [email protected] +41 34 497 28 21 fax: +46 8 630 11 70 [email protected] KKD Denmark: www.kkd.dk MetaLink U.S.A.: Chandler, AZ www.metaice.com National Germany: Kirchseeon 1-800-638-2423 [email protected] 80-91-5696-0 fax: 1-602-926-1198 [email protected] fax: 80-91-2386 bbs: 1-602-962-0013 [email protected] www.metalink.de Distributors Worldwide U.S.A.: Santa Clara, CA www.national.com/cop8 Europe: +49 (0) 180 530 8585 1-800-272-9959 [email protected] fax: +49 (0) 180 530 8586 fax: 1-800-737-7018 [email protected] Distributors Worldwide Customer Support Complete product information and technical support is available from National’s customer responses centers, and from our on-line COP8 customer support sites. The following companies have approved COP8 programmers in a variety of configurations. Contact your local office or distributor. You can link to their web sites and get the latest listing of approved programmers from National’s COP8 OTP Support page at: www.national.com/cop8. Advantech; Advin; BP Microsystems; Data I/O; Hi-Lo Systems; ICE Technology; Lloyd Research; Logical Devices; MQP; Needhams; Phyton; SMS; Stag Programmers; System General; Tribal Microsystems; Xeltek. 43 www.national.com COP888EK Development Support COP888EK Physical Dimensions inches (millimeters) unless otherwise noted Molded SO Wide Body Package (WM) Order Number COP684EK-XXX/WM, COP884EK-XXX/WM, COP984EK-XXX/WM or COP984EKH-XXX/WM NS Package Number M28B Molded Dual-In-Line Package (N) Order Number COP684EK-XXX/N, COP884EK-XXX/N, COP984EK-XXX/N or COP984EKH-XXX/N NS Package Number N28B www.national.com 44 COP888EK Physical Dimensions inches (millimeters) unless otherwise noted (Continued) Molded Dual-In-Line Package (N) Order Number COP688EK-XXX/N, COP888EK-XXX/N, COP988EK-XXX/N or COP988EKH-XXX/N NS Package Number N40A Plastic Leaded Chip Carrier (V) Order Number COP688EK-XXX/V, COP888EK-XXX/V, COP988EK-XXX/V or COP988EKH-XXX/V NS Package Number V44A 45 www.national.com COP888EK 8-Bit CMOS ROM Based Microcontrollers with 8k Memory, Comparator, and Single-slope A/D Capability Notes LIFE SUPPORT POLICY NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. National Semiconductor Corporation Americas Tel: 1-800-272-9959 Fax: 1-800-737-7018 Email: [email protected] www.national.com National Semiconductor Europe Fax: +49 (0) 1 80-530 85 86 Email: [email protected] Deutsch Tel: +49 (0) 1 80-530 85 85 English Tel: +49 (0) 1 80-532 78 32 Français Tel: +49 (0) 1 80-532 93 58 Italiano Tel: +49 (0) 1 80-534 16 80 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. National Semiconductor Asia Pacific Customer Response Group Tel: 65-2544466 Fax: 65-2504466 Email: [email protected] National Semiconductor Japan Ltd. Tel: 81-3-5639-7560 Fax: 81-3-5639-7507 National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.