± 0.33˚C Accurate, 12-Bit + Sign Temperature Sensor and
Thermal Window Comparator with Two-Wire Interface
General Description
The LM92 is a digital temperature sensor and thermal window comparator with an I2C™ Serial Bus interface and an
accuracy of ± 0.33˚C. The window-comparator architecture
of the LM92 eases the design of temperature control systems. The open-drain Interrupt (INT) output becomes active
whenever temperature goes outside a programmable window, while a separate Critical Temperature Alarm
(T_CRIT_A) output becomes active when the temperature
exceeds a programmable critical limit. The INT output can
operate in either a comparator or event mode, while the
T_CRIT_A output operates in comparator mode only.
The host can program both the upper and lower limits of the
window as well as the critical temperature limit. Programmable hysterisis as well as a fault queue are available to
minimize false tripping. Two pins (A0, A1) are available for
address selection. The sensor powers up with default thresholds of 2˚C THYST, 10˚C TLOW, 64˚C THIGH, and 80˚C
T_CRIT.
The LM92’s 2.7V to 5.5V supply voltage range, Serial Bus
interface, 12-bit + sign output, and full-scale range of over
128˚C make it ideal for a wide range of applications. These
include thermal management and protection applications in
personal computers, electronic test equipment, office electronics, automotive, medical and HVAC applications.
Features
n Window comparison simplifies design of ACPI
compatible temperature monitoring and control.
n Serial Bus interface
n Separate open-drain outputs for Interrupt and Critical
Temperature shutdown
n
n
n
n
Shutdown mode to minimize power consumption
Up to 4 LM92s can be connected to a single bus
12-bit + sign output
Operation up to 150˚C
Key Specifications
j Supply Voltage
j Supply Current
2.7V to 5.5V
operating
350 µA (typ)
625 µA (max)
shutdown
5 µA (typ)
30˚C ± 0.33˚C (max)
j Temperature
10˚C to 50˚C ± 0.50˚C (max)
Accuracy
−10˚C to 85˚C
± 1.0˚C (max)
125˚C ± 1.25˚C (max)
−25˚C to 150˚C
j Linearity
j Resolution
± 1.5˚C (max)
± 0.5˚C (max)
0.0625˚C
Applications
n
n
n
n
n
n
n
HVAC
Medical Electronics
Electronic Test Equipment
System Thermal Management
Personal Computers
Office Electronics
Automotive
Simplified Block Diagram
10105101
I2C ® is a registered trademark of Philips Corporation.
© 2005 National Semiconductor Corporation
DS101051
www.national.com
LM92 ± 0.33˚C Accurate, 12-Bit + Sign Temperature Sensor and Thermal Window Comparator with
Two-Wire Interface
March 2005
LM92
Connection Diagram
SO-8
10105102
LM92
See NS Package Number M08A
Ordering Information
Order Number
Supply Voltage
LM92CIM
2.7V to 5.5V
LM92CIMX
2.7V to 5.5V
Supplied As
2500 Units on Tape and Reel
Pin Descriptions
Label
SDA
Pin #
1
Function
Typical Connection
Serial Bi-Directional Data Line. Open Drain Output
From Controller
SCL
2
Serial Bus Clock Input
From Controller
T_CRIT_A
3
Critical Temperature Alarm Open Drain Output
Pull Up Resistor, Controller Interrupt Line
or System Hardware Shutdown
GND
4
Power Supply Ground
Ground
INT
5
Interrupt Open Drain Output
Pull Up Resistor, Controller Interrupt Line
8
Positive Supply Voltage Input
DC Voltage from 2.7V to 5.5V
User-Set Address Inputs
Ground (Low, “0”) or +VS (High, “1”)
+V S
A0–A1
7,6
Typical Application
10105103
FIGURE 1.
www.national.com
2
Supply Voltage
Human Body Model
Machine Model
−0.3 V to 6.5V
Voltage at any Pin
−0.3 V
to (+VS + 0.3V)
Input Current at any Pin
20 mA
T_CRIT_A and INT Output Sink
Current
10 mA
T_CRIT_A and INT Output
Voltage
Specified Temperature Range
(Note 6)
TMIN to TMAX
−55˚C to +150˚C
Supply Voltage Range (+VS)
+2.7V to +5.5V
Soldering process must comply with National Semiconductor’s Reflow Temperature Profile specifications. Refer to
www.national.com/packaging. (Note 3)
6.5V
Storage Temperature
250V
Operating Ratings(Notes 1, 5)
5 mA
Package Input Current (Note 2)
2500V
−65˚C to +125˚C
ESD Susceptibility (Note 4)
Electrical Characteristics
Temperature-to-Digital Converter Characteristics
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ
= TMIN to TMAX; all other limits TA= TJ= +25˚C, unless otherwise noted.
Typical
(Note 7)
Parameter
Conditions
Accuracy (This is a summary. For
more detailed information please see
(Note 9))
T A = 10˚C or +50˚C, +VS = 3.3V
to 4.0V
T
A
± 1.00
= +125˚C, +VS = 4.0V
± 1.25
± 1.50
A
T A = −25˚C to 150˚C, +VS =
4.0V
(Note 10)
13
0.0625
˚C (max)
Bits
˚C
± 0.5
Linearity (Note 11)
Offset Error of Transfer Function
(Note 12)
Units
(Limit)
± 0.33
± 0.50
= +30˚C, +VS = 3.3V to 4.0V
T A = −10 ˚C or +85˚C, +VS =
3.3V to 4.0V
T
Resolution
Limits
(Note 8)
+VS = 4.0V
˚C (max)
˚C (max)
Offset Error of Transfer Function
Supply Sensitivity
2.7V ≤ +VS < 3.6V
˚C/V (max)
3.6V ≤ +VS≤ 5.5V
˚C/V (max)
Temperature Conversion Time
(Note 13)
500
Quiescent Current
I2C Inactive
0.35
I2C Active
0.35
Shutdown Mode
5
1000
ms
mA
0.625
mA (max)
µA
T
HYST
(Notes 15, 16)
2
˚C
T
LOW
Default Temperature
(Note 16)
10
˚C
T
HIGH
Default Temperature
(Note 16)
64
˚C
T
C
(Note 16)
80
˚C
Default Temperature
Default Temperature
3
www.national.com
LM92
Absolute Maximum Ratings (Note 1)
LM92
Digital DC Characteristics
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ
= TMIN to TMAX; all other limits TA= TJ= +25 ˚C, unless otherwise noted.
Symbol
Parameter
V IN(1)
SDA and SCL Logical “1” Input
Voltage
V IN(0)
SDA and SCL Logical “0” Input
Voltage
VIN(HYST)
Conditions
SDA and SCL Digital Input
Hysteresis
Typical
(Note 7)
500
V IN(1)
A0 and A1 Logical “1” Input
Voltage
V IN(0)
A0 and A1 Logical “0” Input
Voltage
I IN(1)
Logical “1” Input Current
V
I IN(0)
Logical “0” Input Current
V
C IN
Capacitance of All Digital Inputs
I OH
High Level Output Current
V
V OL
Low Level Output Voltage
I
T_CRIT_A Output Saturation
Voltage
Limits
(Note 8)
Units
(Limit)
+VS x 0.7
V (min)
+VS+0.3
V (max)
−0.3
V (min)
+VS x 0.3
V (max)
250
mV (min)
2.0
V (min)
+VS+0.3
V (max)
−0.3
V (min)
0.7
V (max)
IN
= + VS
0.005
1.0
µA (max)
IN
=0V
−0.005
−1.0
µA (max)
= + VS
10
µA (max)
= 3 mA
0.4
V (max)
I OUT = 4.0 mA
(Note 14)
0.8
V (max)
20
OH
OL
pF
T_CRIT_A Delay
1
Output Fall Time
t OF
C
I
L
O
= 400 pF
Conversions
(max)
250
ns (max)
= 3 mA
Serial Bus Digital Switching Characteristics
Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ
= TMIN to TMAX; all other limits TA= TJ= +25 ˚C, unless otherwise noted. CL (load capacitance) on output lines = 80 pF unless
otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = +25 ˚C, unless otherwise noted.
The switching characteristics of the LM92 fully meet or exceed the published specifications of the I2C bus. The following parameters are the timing relationship between SCL and SDA signal related to the LM92. They are not the I2C bus specifications.
Symbol
t1
Parameter
Conditions
Typical
(Note 7)
Limits
(Note 8)
SCL (Clock) Period
2.5
1
t2
Data in Set-Up Time to SCL High
t3
Data Out Stable after SCL Low
t4
Units
(Limit)
µs(min)
ms(max)
100
ns(min)
0
ns(min)
SDA Low Set-Up Time to SCL Low (Start Condition)
100
ns(min)
t5
SDA High Hold Time after SCL High (Stop Condition)
100
ns(min)
tTIMEOUT
SDA and SCL Time Low for Reset of Serial Interface (Note
17)
75
300
ms (min)
ms (max)
www.national.com
4
LM92
Serial Bus Communication
10105104
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not apply when operating
the device beyond its rated operating conditions.
Note 2: When the input voltage (VI) at any pin exceeds the power supplies (VI < GND or VI > +VS) the current at that pin should be limited to 5 mA. The 20 mA
maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input current of 5 mA to four.
Note 3: Reflow temperature profiles are different for lead-free and non-lead-free packages.
Note 4: Human body model, 100 pF discharged through a 1.5 kΩ resistor. Machine model, 200 pF discharged directly into each pin.
Note 5: LM92 θJA (thermal resistance, junction-to-ambient) when attached to a printed circuit board with 2 oz. foil is 200 ˚C/W.
Note 6: While the LM92 has a full-scale-range in excess of 128 ˚C, prolonged operation at temperatures above 125 ˚C is not recommended.
Note 7: Typicals are at TA = 25 ˚C and represent most likely parametric norm.
Note 8: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level).
5
www.national.com
LM92
Note 9: The limits found in the following table supersede the limits shown in the Electrical Characteristics Table. The Accuracy specification includes errors due to
linearity, offset and gain. The accuracy specification includes effects of self heating with negligible digital output loading. Pull-up resistors should be maximized (10k
typical recommended), so that self heating due to digital output loading is negligible.
Temperature Accuracy Parameter Limits
Units
Conditions
+VS=2.7V
+VS=3.3V
+VS=4V
+VS=5V
+VS=5.5V
T A = −25˚C
−1.35/+1.50
−1.25/+1.50
−1.25/+1.50
−1.05/+1.70
−1.05/+1.80
T A = −10˚C
± 1.00
−0.90/+1.00
−0.90/+1.00
−0.70/+1.20
−0.70/+1.30
˚C (max)
T A = 0˚C
−0.80/+0.75
−0.70/+0.75
−0.70/+0.75
−0.50/+0.95
−0.50/+1.05
˚C (max)
T A = 10˚C
−0.60/+0.50
˚C (max)
−0.13/+0.53
−0.13/+0.63
˚C (max)
T A = 50˚C
−0.60/+0.50
± 0.50
± 0.33
± 0.50
−0.30/+0.80
−0.43/+0.33
± 0.50
± 0.33
± 0.50
−0.30/+0.70
T A = 30˚C
−0.30/+0.70
−0.30/+0.80
˚C (max)
T A = 85˚C
−1.10/+0.85
−1.00/+0.85
−1.00/+0.85
−0.80/+1.05
−0.80/+1.15
˚C (max)
T A = 125˚C
−1.60/+1.25
−1.50/+1.25
−1.05/+1.55
˚C (max)
± 1.90
−1.75/+1.50
± 1.25
± 1.50
−1.05/+1.45
T A = 150˚C
−1.30/+1.70
−1.30/+1.80
˚C (max)
˚C (max)
Limits at intermediate temperatures can be calculated using a straight line interpolation as shown in the following graphs:
Accuracy vs Temperature with +Vs = 5V
10105120
Accuracy vs Temperature with +Vs = 3.3V
10105121
Note 10: 12 bits + sign, two’s complement
Note 11: Linearity Error is defined as the worse case difference of an actual reading to that of a calculated reading derived from the straight line whose endpoints
are measured at 30˚C and 125˚C for the range of 30˚C to 125˚C or whose endpoints are measured at 30˚C and −25˚C for the range of 30˚C to −25˚.
Note 12: Offset Error calibration should be done at 30˚C. The residual error of the transfer function is then equivalent to the Accuracy Limit minus the Offset Limit.
This does not take into account the power supply sensitivity of the offset error. Nor, does it take into account the error introduced by the calibration system used.
www.national.com
6
Note 14: For best accuracy, minimize output loading. 10k pull-ups resistors should be sufficient. Higher sink currents can affect sensor accuracy with internal
heating. This can cause an error of 0.64 ˚C at full rated sink current and saturation voltage based on junction-to-ambient thermal resistance.
Note 15: Hysteresis value adds to the TLOW setpoint value (e.g.: if TLOW setpoint = 10 ˚C, and hysteresis = 2 ˚C, then actual hysteresis point is 10+2 = 12 ˚C); and
subtracts from the THIGH and T_CRIT setpoints (e.g.: if THIGH setpoint = 64 ˚C, and hysteresis = 2 ˚C, then actual hysteresis point is 64−2 = 62 ˚C). For a detailed
discussion of the function of hysteresis refer to Section 1.1, TEMPERATURE COMPARISON, and Figure 3.
Note 16: Default values set at power up.
Note 17: Holding the SDA and/or SCL lines Low for a time interval greater than tTIMEOUT will cause the LM92 to reset SCL and SDA to the IDLE state of the serial
bus communication (SDA and SCL set High).
10105105
FIGURE 2. Temperature-to-Digital Transfer Function (Non-linear scale for clarity)
7
www.national.com
LM92
Note 13: This specification is provided only to indicate how often temperature data is updated. The LM92 can be read at any time without regard to conversion state
(and will yield last conversion result). If a conversion is in process it will be interrupted and restarted after the end of the read.
LM92
However if the user read the part, the output would be reset.
Even if the condition is true, it will remain reset. The temperature must cross above TLOW + THYST to set the output
again.
1.0 Functional Description
The LM92 temperature sensor incorporates a band-gap type
temperature sensor, 13-bit ADC, and a digital comparator
with user-programmable upper and lower limit values. The
comparator activates either the INT line for temperatures
outside the TLOW and THIGH window, or the T_CRIT_A line
for temperatures which exceed T_CRIT. The lines are programmable for mode and polarity.
In either mode, reading any register in the LM92 restarts the
conversion. This allows a designer to know exactly when the
LM92 begins a comparison. This prevents unnecessary Interrupts just after reprogramming setpoints. Typically, system Interrupt inputs are masked prior to reprogramming trip
points. By doing a read just after resetting trip points, but
prior to unmasking, unexpected Interrupts are prevented.
Avoid programming setpoints so close that their hysteresis
values overlap. An example would be that with a THYST value
of 2 ˚C then setting THIGH and TLOW to within 4 ˚C of each
other will violate this restriction. To be more specific, with
THYST set to 2 ˚C assume THIGH set to 64 ˚C. If TLOW is set
equal to, or higher than 60 ˚C this restriction is violated.
1.1 TEMPERATURE COMPARISON
LM92 provides a window comparison against a lower (TLOW)
and upper (THIGH) trip point. A second upper trip point
(T_CRIT) functions as a critical alarm shutdown. Figure 3
depicts the comparison function as well as the modes of
operation.
1.1.1 Status Bits
The internal Status bits operate as follows:
“True”: Temperature above a THIGH or T_CRIT is “true” for
those respective bits. A “true” for TLOW is temperature below
TLOW.
“False”: Assuming temperature has previously crossed
above THIGH or T_CRIT, then the temperature must drop
below the points corresponding THYST (THIGH − THYST or
T_CRIT − THYST) in order for the condition to be false. For
TLOW, assuming temperature has previously crossed below
TLOW, a “false” occurs when temperature goes above TLOW
+ THYST.
The Status bits are not affected by reads or any other
actions, and always represent the state of temperature vs.
setpoints.
1.2 DEFAULT SETTINGS
The LM92 always powers up in a known state. LM92 power
up default conditions are:
1.
2.
Comparator Interrupt Mode
TLOW set to 10 ˚C
3. THIGH set to 64 ˚C
4. T_CRIT set to 80 ˚C
5. THYST set to 2 ˚C
6. INT and T_CRIT_A active low
7. Pointer set to “00”; Temperature Register
The LM92 registers will always reset to these default values
when the power supply voltage is brought up from zero volts
as the supply crosses the voltage level plotted in the following curve. The LM92 registers will reset again when the
power supply drops below the voltage plotted in this curve.
1.1.2 Hardwire Outputs
The T_CRIT_A hardwire output mirrors the T_CRIT_A flag,
when the flag is true, the T_CRIT_A output is asserted at all
times regardless of mode. Reading the LM92 has no effect
on the T_CRIT_A output, although the internal conversion is
restarted.
The behavior of the INT hardwire output is as follows:
Comparator Interrupt Mode (Default): User reading part
resets output until next measurement completes. If condition
is still true, output is set again at end of next conversion
cycle. For example, if a user never reads the part, and
temperature goes below TLOW then INT becomes active. It
would stay that way until temperature goes above TLOW +
THYST. However if the user reads the part, the output would
be reset. At the end of the next conversion cycle, if the
condition is true, it is set again. If not, it remains reset.
Event Interrupt Mode: User reading part resets output
until next condition "event" occurs (in other words, output is
only set once for a true condition, if reset by a read, it
remains reset until the next triggering threshold has been
crossed). Conversely, if a user never read the part, the
output would stay set indefinitely after the first event that set
the output. An “event” for Event Interrupt Mode is defined as:
1. Transitioning upward across a setpoint, or
2. Transitioning downward across a setpoint’s corresponding hysteresis (after having exceeded that setpoint).
For example, if a user never read the part, and temperature
went below TLOW then INT would become active. It would
stay that way forever if a user never read the part.
www.national.com
Average Power on Reset Voltage
vs Temperature
10105118
1.3 SERIAL BUS INTERFACE
The LM92 operates as a slave on the Serial Bus, so the SCL
line is an input (no clock is generated by the LM92) and the
SDA line is a bi-directional serial data line. According to
Serial Bus specifications, the LM92 has a 7-bit slave address. The five most significant bits of the slave address are
hard wired inside the LM92 and are “10010”. The two least
significant bits of the address are assigned to pins A1–A0,
and are set by connecting these pins to ground for a low, (0);
or to +VS for a high, (1).
8
(Continued)
MSB
LSB
Therefore, the complete slave address is:
1
0
0
1
0
A1
A0
10105106
Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn’t read, the outputs would go low and stay that way until the LM92 is read.
Comparator Interrupt Mode is drawn as if the user never reads the part. If the user does read, the outputs will go high once read instruction is executed and, if the
fault condition still exists, go low at the end of the next conversion.
FIGURE 3. Temperature Response Diagram
1.4 TEMPERATURE DATA FORMAT
Temperature data can be read from the Temperature and Set
Point registers; and written to the Set Point registers. Temperature data can be read at any time, although reading
faster than the conversion time of the LM92 will prevent data
from being updated. Temperature data is represented by a
13-bit, two’s complement word with an LSB (Least Significant Bit) equal to 0.0625 ˚C:
Temperature
−0.0625 ˚C
Binary
Hex
08 20h
+125 ˚C
0 0111 1101 0000
07 D0h
+80 ˚C
0 0101 0000 0000
05 00h
+64 ˚C
0 0100 0000 0000
04 00h
+25 ˚C
0 0001 1001 0000
01 90h
+10 ˚C
0 0000 1010 0000
00 A0h
+2 ˚C
0 0000 0010 0000
00 20h
+0.0625 ˚C
0 0000 0000 0001
00 01h
0 ˚C
00 0000 0000
00 00h
Digital Output
Binary
Hex
1 1111 1111 1111
1F FFh
−25 ˚C
1 1110 0111 0000
1E 70h
−55 ˚C
1 1100 1001 0000
1C 90h
1.5 SHUTDOWN MODE
Shutdown mode is enabled by setting the shutdown bit in the
Configuration register via the Serial Bus. Shutdown mode
reduces power supply current to 5 µA typical. T_CRIT_A is
reset if previously set. Since conversions are stoped during
shutdown, T_CRIT_A and INT will not be operational. The
Serial Bus interface remains active. Activity on the clock and
data lines of the Serial Bus may slightly increase shutdown
mode quiescent current. Registers can be read from and
written to in shutdown mode. The LM92 takes miliseconds to
respond to the shutdown command.
Digital Output
0 1000 0 010 0000
+130˚C
Temperature
1.6 INT AND T_CRIT_A OUTPUT
The INT and T_CRIT_A outputs are open-drain outputs and
do not have internal pull-ups. A "high" level will not be
9
www.national.com
LM92
1.0 Functional Description
LM92
1.0 Functional Description
1.7 FAULT QUEUE
A fault queue of 4 faults is provided to prevent false tripping
when the LM92 is used in noisy environments. The 4 faults
must occur consecutively to set flags as well as INT and
T_CRIT_A outputs. The fault queue is enabled by setting bit
4 of the Configuration Register high (see Section 1.11).
(Continued)
observed on these pins until pull-up current is provided from
some external source, typically a pull-up resistor. Choice of
resistor value depends on many system factors but, in general, the pull-up resistor should be as large as possible. This
will minimize any errors due to internal heating of the LM92.
The maximum resistance of the pull up, based on LM92
specification for High Level Output Current, to provide a 2
volt high level, is 30K ohms.
1.8 INTERNAL REGISTER STRUCTURE
10105107
There are four data registers in the LM92, selected by the
Pointer register. At power-up the Pointer is set to “00”; the
location for the Temperature Register. The Pointer register
latches the last location it was set to. In Interrupt Mode, a
read from the LM92 resets the INT output. Placing the device
in Shutdown mode resets the INT and T_CRIT_A outputs. All
registers are read and write, except the Temperature register
which is read only.
A write to the LM92 will always include the address byte and
the Pointer byte. A write to the Configuration register requires one data byte, while the TLOW, THIGH, and T_CRIT
registers require two data bytes.
Reading the LM92 can take place either of two ways: If the
location latched in the Pointer is correct (most of the time it is
expected that the Pointer will point to the Temperature register because it will be the data most frequently read from the
LM92), then the read can simply consist of an address byte,
followed by retrieving the corresponding number of data
bytes. If the Pointer needs to be set, then an address byte,
www.national.com
pointer byte, repeat start, and another address byte plus
required number of data bytes will accomplish a read.
The first data byte is the most significant byte with most
significant bit first, permitting only as much data as necessary to be read to determine the temperature condition. For
instance, if the first four bits of the temperature data indicates a critical condition, the host processor could immediately take action to remedy the excessive temperature. At
the end of a read, the LM92 can accept either Acknowledge
or No Acknowledge from the Master (No Acknowledge is
typically used as a signal for the slave that the Master has
read its last byte).
An inadvertent 8-bit read from a 16-bit register, with the D7
bit low, can cause the LM92 to stop in a state where the SDA
line is held low as shown in Figure 4. This can prevent any
further bus communication until at least 9 additional clock
cycles have occurred. Alternatively, the master can issue
clock cycles until SDA goes high, at which time issuing a
“Stop” condition will reset the LM92.
10
LM92
1.0 Functional Description
(Continued)
10105108
FIGURE 4. Inadvertent 8-Bit Read from 16-Bit Register where D7 is Zero (“0”)
1.9 POINTER REGISTER
(Selects which registers will be read from or written to):
P7
P6
P5
P4
P3
0
0
0
0
0
P2
P1
P0
Register Select
P0–P2: Register Select:
P2
P1
P0
0
0
0
Temperature (Read only) (Power-up
default)
0
0
1
Configuration (Read/Write)
0
1
0
THYST (Read/Write)
0
1
1
T_CRIT (Read/Write)
1
0
0
TLOW (Read/Write)
1
0
1
THIGH (Read/Write)
1
1
1
Register
Manufacturer’s ID
P3–P7: Must be kept zero.
1.10 TEMPERATURE REGISTER
(Read Only):
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
Sign
MSB
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
CRIT
D1
D0
HIGH
LOW
Status Bits
D0–D2: Status Bits
D3–D15: Temperature Data. One LSB = 0.0625˚C. Two’s complement format.
1.11 CONFIGURATION REGISTER
(Read/Write):
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
Fault Queue
INT Polarity
T_CRIT_A
Polarity
INT Mode
Shutdown
D0: Shutdown - When set to 1 the LM92 goes to low power shutdown mode. Power up default of “0”.
D1: Interrupt mode - 0 is Comparator Interrupt mode, 1 is Event Interrupt mode. Power up default of “0”.
D2, D3: T_CRIT_A and INT Polarity - 0 is active low, 1 is active high. Outputs are open-drain. Power up default of “0”
D4: Fault Queue - When set to 1 the Fault Queu is enabled, see Section 1.7. Power up default of “0”.
D5–D7: These bits are used for production testing and must be kept zero for normal operation.
1.12 THYST, TLOW, THIGH AND T_CRIT_A REGISTERS
(Read/Write):
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
Sign
MSB
Bit 10
Bit 9
Bit 8
Bit7
Bit6
Bit5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
X
X
X
D0–D2: Undefined
11
www.national.com
LM92
1.0 Functional Description
(Continued)
D3–D15: THYST, TLOW, THIGH or T_CRIT Trip Temperature Data. Power up default is TLOW = 10˚C, THIGH = 64˚C, T_CRIT = 80˚C,
THYST = 2˚C.
THYST is subtracted from THIGH, and T_CRIT, and added to TLOW.
Avoid programming setpoints so close that their hysteresis values overlap. See Section 1.1.
1.13 Manufacturer’s Identification Register
(Read only):
D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
D0–D15: Manufactures ID.
www.national.com
12
LM92
2.0 I2C Timing Diagrams
10105109
Typical 2-Byte Read From Preset Pointer Location Such as Temp or Comparison Registers
10105110
Typical Pointer Set Followed by Immediate Read for 2-Byte Register such as Temp or Comparison Registers
10105111
Typical 1-Byte Read from Configuration Register with Preset Pointer
FIGURE 5.
13
www.national.com
LM92
2.0 I2C Timing Diagrams
(Continued)
10105112
Typical Pointer Set Followed by Immediate Read from Configuration Register
10105113
Configuration Register Write
10105114
Comparison Register Write
FIGURE 6. Timing Diagrams
issue an interrupt, service the interrupt, and reprogram the
window according to the desired granularity of the temperature scale. The reprogrammed window will now have the
current temperature inside it, ready to issue an interrupt
whenever the temperature deviates from the current window.
To understand this graph, assume that at the left hand side
the system is at some nominal temperature. For the 1st
event temperature rises above the upper window limit,
THIGH, causing INT to go active. The system responds to the
interrupt by querying the LM92’s status bits and determines
that THIGH was exceeded, indicating that temperature is
rising. The system then reprograms the temperature limits to
a value higher by an amount equal to the desired granularity.
Note that in Event Interrupt Mode, reprogramming the limits
has caused a second, known, interrupt to be issued since
temperature has been returned within the window. In Comparator Interrupt Mode, the LM92 simply stops issuing interrupts.
The 2nd event is another identical rise in temperature. The
3rd event is typical of a drop in temperature. This is one of
the conditions that demonstrates the power of the LM92, as
the user receives notification that a lower limit is exceeded in
such a way that temperature is dropping.
The Critical Alarm Event activates the separate T_CRIT_A
output. Typically, this would feed circuitry separate from the
processor on the assumption that if the system reached this
temperature, the processor might not be responding.
3.0 Application Hints
The temperature response graph in Figure 7 depicts a typical application designed to meet ACPI requirements. In this
type of application, the temperature scale is given an arbitrary value of "granularity", or the window within which temperature notification events should occur. The LM92 can be
programmed to the window size chosen by the designer, and
will issue interrupts to the processor whenever the window
limits have been crossed. The internal flags permit quick
determination of whether the temperature is rising or falling.
The T_CRIT limit would typically use its separate output to
activate hardware shutdown circuitry separate from the processor. This is done because it is expected that if temperature has gotten this high that the processor may not be
responding. The separate circuitry can then shut down the
system, usually by shutting down the power supply.
Note that the INT and T_CRIT_A outputs are separate, but
can be wire-or’d together. Alternatively the T_CRIT_A can be
diode or’d to the INT line in such a way that a T_CRIT_A
event activates the INT line, but an INT event does not
activate the T_CRIT_A line. This may be useful in the event
that it is desirable to notify both the processor and separate
T_CRIT_A shutdown circuitry of a critical temperature alarm
at the same time (maybe the processor is still working and
can coordinate a graceful shutdown with the separate shutdown circuit).
To implement ACPI compatible sensing it is necessary to
sense whenever the temperature goes outside the window,
www.national.com
14
LM92
3.0 Application Hints
(Continued)
10105115
Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn’t read, the outputs would go low and stay that way until the LM92 is read.
FIGURE 7. Temperature Response Diagram for ACPI Implementation
4.0 Typical Applications
10105116
FIGURE 8. Typical Application
15
www.national.com
LM92
4.0 Typical Applications
(Continued)
10105117
FIGURE 9. Remote HVAC temperature sensor communicates via 3 wires, including thermostat signals.
10105119
FIGURE 10. ACPI Compatible Terminal Alarm Shutdown. By powering the LM92 from auxilary output of the power
supply, a non-functioning overheated computer can be powered down to preserve as much of the system as
possible.
www.national.com
16
inches (millimeters) unless otherwise noted
8-Lead (0.150" Wide) Molded Small Outline Package (SOP), JEDEC
Order Number LM92CIM or LM92CIMX
NS Package Number M08A
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves
the right at any time without notice to change said circuitry and specifications.
For the most current product information visit us at www.national.com.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body, or
(b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result
in a significant injury to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or
system, or to affect its safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor manufactures products and uses packing materials that meet the provisions of the Customer Products
Stewardship Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain
no ‘‘Banned Substances’’ as defined in CSP-9-111S2.
National Semiconductor
Americas Customer
Support Center
Email: [email protected]
Tel: 1-800-272-9959
www.national.com
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
Email: [email protected]
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
National Semiconductor
Asia Pacific Customer
Support Center
Email: [email protected]
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: [email protected]
Tel: 81-3-5639-7560
LM92 ± 0.33˚C Accurate, 12-Bit + Sign Temperature Sensor and Thermal Window Comparator with
Two-Wire Interface
Physical Dimensions